101 BAG electronics | Product Catalogue 2014 Electronic control units for T5 fluorescent lamps MLS EVO T5 and TC-L | Multi-Lamp-Technology | linear ............... 112 MLD EVO DIM DALI T5 and TC-L | Multi-Lamp-Technology | linear ............... 116 BCS PRIMUS T5 and TC-L/F | linear ........................................................... 120 BCD 1-10 V T5 | linear .................................................................................. 124 Electronic control units for T8 fluorescent lamps BCS PRIMUS T8 | linear ..................................................................................128 BCD 1-10 V T8 and TC-L/F | linear........................................................... 130 Electronic control units for compact fluorescent lamps BCS TC CFL, T5 and T8 | compact ...................................................... 134 BCS TCTWINGLE CFL, T5 and T8 | compact ......................................................136 BCS TCTWINGLE CFL, T5 and T8 | independent .............................................. 140 BCS TC CFL, T5 and T8 | linear ............................................................ 144 EBS MINIPOWER CFL, T5 and T8 | compact ......................................................148 BCD TC DALI CFL, T5 and T8 | Twingle-Technology |compact................ 152 BCD TC 1-10 V CFL, T5 and T8 | Twingle-Technology |compact................ 154 BCD CFL 1-10 V CFL and T5 | compact .............................................................156 Components for fluorescent lamps Components for fluorescent lamps
57
Embed
Komponenten für Leuchtstofflampen Components for … electronics... · Komponenten für Leuchtstofflampen 100 Product Catalogue 2014 | BAG electronics BAG electronics | Product
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Elektronische Vorschaltgeräte für
T5- Leuchtstofflampen MLS EVO T5 und TC-L | Multi-Lamp-Technologie | linear .............. 102
MLD EVO DIM DALI T5 und TC-L | Multi-Lamp-Technologie | linear .............. 106
BCS PRIMUS T5 und TC-L/F | linear ............................................................ 110
BCD 1-10 V T5 | linear ...................................................................................114
Elektronische Vorschaltgeräte für
T8- LeuchtstofflampenBCS PRIMUS T8 | linear .................................................................................. 118
BCD 1-10 V T8 und TC-L/F | linear .......................................................... 120
Elektronische Vorschaltgeräte für
KompaktleuchtstofflampenBCS TC CFL, T5 und T8 | kompakt ...................................................... 124
BCS TCTWINGLE CFL, T5 und T8 | kompakt ......................................................126
BCS TCTWINGLE CFL, T5 und T8 | unabhängig ............................................... 130
Komponenten für Leuchtstofflampen
Kom
pone
nten
für L
euch
tsto
fflam
pen
100 101 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Electronic control units for
T5 fluorescent lamps MLS EVO T5 and TC-L | Multi-Lamp-Technology | linear ............... 112
MLD EVO DIM DALI T5 and TC-L | Multi-Lamp-Technology | linear ............... 116
BCS PRIMUS T5 and TC-L/F | linear ........................................................... 120
BCD 1-10 V T5 | linear .................................................................................. 124
Electronic control units for
T8 fluorescent lampsBCS PRIMUS T8 | linear ..................................................................................128
BCD 1-10 V T8 and TC-L/F | linear ........................................................... 130
Electronic control units for compact
fluorescent lampsBCS TC CFL, T5 and T8 | compact ......................................................134
BCS TCTWINGLE CFL, T5 and T8 | compact ......................................................136
BCS TCTWINGLE CFL, T5 and T8 | independent .............................................. 140
BCS TC CFL, T5 and T8 | linear ............................................................ 144
EBS MINIPOWER CFL, T5 and T8 | compact ......................................................148
BCD TC DALI CFL, T5 and T8 | Twingle-Technology |compact ................152
BCD TC 1-10 V CFL, T5 and T8 | Twingle-Technology |compact ................154
BCD CFL 1-10 V CFL and T5 | compact .............................................................156
110 111 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Productfinder - Selection table
Power Lamp Numberof Lamps
Description Order No. LenghtX
WidthY
HeightZ
Interface Page
[W] [mm] [mm] [mm]
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
112 113 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
MLS EVONon-dimmable electronic control gear for T5 and TC-L lamps with Multi-Lamp-Technology
Control gear for FLElectronic control gears (non-dim
mable) | M
LS EVO
• Multi-Lamp technology for automatic lamp recognition and optimum operation of T5 and TC-L/F lamps
• Luminaire can be fitted with different lamps (e.g. T5: 35W, 49W, 80W)
• Compact housing in slim design for space-saving application in luminaires
• Energy-controlled electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI = A2BAT
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350V / 2 h
Max. leakage current 0.5 mA
Technical dataProduct information Conformity
Designations
112 113 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material- number
Lamp designation System rating Input current Operation frequency
114 115 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
MLS
EVO
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 62386-102
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
push
Industry
Office & Commercial
Outdoor
Shop
116 117 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
MLD EVO DALIDALI dimmable electronic control gear for T5 and TC-L lamps with Multi-Lamp-Technology
Control gear for FLElectronic control gears (dim
mable) | M
LD EVO DIM DALI
• Multi-Lamp technology for automatic lamp recognition and optimum operation of T5 and TC-L/F lamps
• Twingle operation with 1 or 2 lamps*
• Luminaire can be fitted with different lamps (e.g. T5: 35W, 49W, 80W)
• Compact housing in slim design for space-saving application in luminaires
• Energy-controlled electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI = A2/A2BAT
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350V / 2 h
Overvoltage protection DALI interface 264 V / permanent
Max. leakage current 0.5 mA
Technical dataProduct information Conformity
Designations
116 117 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material- number
Lamp designation System rating Input current Operation frequency
118 119 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Control gear for FLElectronic control gears (dim
mable) | M
LD EVO DIM DALI
Wiring diagrams
Case drawing
118 119 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(dim
mab
le) |
MLD
EVO
DIM
DAL
I
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
120 121 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCS PRIMUS T5Non-dimmable electronic control gear for T5 and TC-L/F lamps
• Short housing in flat design for space-saving application in luminaires
• Multipower - Technology for operation with different lamps on the same control gear
• Energy controlled, electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1,5 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Flimmer free light through high frequency lamp operation, no stroboscope effect
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI= A2BAT
• Extended nominal service life*: 75.000 h at tc=tc,max with failure rate of ≤ 10% 100.000 h operation at tc=tc,max -10 K with failure rate ≤ 10 %
122 123 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Case drawing
Wiring diagrams
Control gear for FLElectronic control gears (non-dim
mable) | BCS PRIM
US T5
122 123 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
BCS
PRI
MUS
T5
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
124 125 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCD T5 1-10VDimmable electronic control gear for T5 lamps
• Dimming interface: 1–10 V
• Dimming range 1...100% luminous flux
• Energy controlled, electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1,5 s
• Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Energy efficiency index EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 ... 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350V / 2 h
Max. leakage current 0.5 mA
Max. control current (1-10V) 0.2 mA
Technical dataProduct information Conformity
Designations
Control gear for FLElectronic control gears (dim
mable) | BCD T5 1-10V
X M
YZ
X
ZM
M
124 125 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material- number
Lamp designation System rating Input current Operation frequency
Short designation Length X Width Y Height Z Hole spacing XM (length direction)
Hole spacing ZM (height direction)
Diagram Weight Ambienttemperatureta
Housingtemperature tc,max
mm mm mm mm mm kg °C °C
BCD35.1F-01 360 30 21 350 9 M 0.250 5 ... 55 75
BCD39.1F-01 360 30 21 350 9 M 0.246 5 ... 55 70
BCD49.1F-01 360 30 21 350 9 M 0.252 5 ... 55 70
BCD54.1F-01 360 30 21 350 9 M 0.262 5 ... 55 70
BCD80.1F-01 360 30 21 350 9 M 0.262 5 ... 55 70
BCD14.3F-01 360 39 21 350 9 M 0.325 5 ... 60 75
BCD14.4F-01 360 39 21 350 9 M 0.317 5 ... 60 75
BCD35.2F-01 420 30 20 415 9 M 0.328 5 ... 55 75
BCD39.2F-01 425 30 21 415 9 M 0.328 5 ... 55 70
BCD49.2F-01 425 30 21 415 9 M 0.356 5 ... 55 70
BCD54.2F-01 425 30 21 415 9 M 0.330 5 ... 55 75
BCD80.2F-01 425 30 21 415 9 M 0.386 5 ... 55 75
Dimensions | weights | temperatures
Case drawing
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(dim
mab
le) |
BCD
T5
1-10
V
64
1234
1−10 V
74
12345671−10 V
75
123456
17161514n.c.
–
7
+ 1-10V
76
123456
17161514n.c.
–
7
+ 1-10V
126 127 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Wiring diagrams
Control gear for FLElectronic control gears (dim
mable) | BCD T5 1-10V
126 127 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(dim
mab
le) |
BCD
T5
1-10
V
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
128 129 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCS PRIMUS T8Non-dimmable electronic control gear for T8 lamps
Control gear for FLElectronic control gears (non-dim
mable) | BCS PRIM
US T8
• Short housing in flat design for space-saving applica-tion in luminaires
• Energy controlled, electrode preserving lamp warm start for maximum lamp life irrespective of switching frequency; starting time < 1,5 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Flimmer free light through high frequency lamp operation, no stroboscope effect
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Constant light output irrespective of mains power fluctuation
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable lumi-naires with safety classification II
• Energy efficiency EEI= A2BAT
• Extended nominal service life*: 75.000 h at tc=tc,max with failure rate of ≤ 10% 100.000 h operation at tc=tc,max -10 K with failure rate ≤ 10 %
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350V /2 h
Max. leakage current 0.5 mA
Technical dataProduct information Conformity
Designations
3
1234
23
123456
X M
YZ
X
ZM
50
123456
5678910
51
123456
5678910
B
128 129 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency
130 131 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCD T8 1-10VDimmable electronic control gear for T8- and TC-L/F lamps
• Dimming interface: 1–10 V
• Dimming range 1...100% luminous flux
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Automatic restart after lamp replacement
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Energie efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350 V / 2 h
Max. leakage current 0.5 mA
Max. control current (1-10V) 0.2 mA
Technical dataProduct information Conformity
Designations
Control gear for FLElectronic control gears (dim
mable) | BCD T8 1-10V
Xm
Z
X
Zm
Y
M
130 131 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency
Short designation Length X Width Y Height Z Hole spacing XM (length direction)
Hole spacing ZM (height direction)
Diagram Weight Ambienttemperature ta
Housingtemperature tc,max
mm mm mm mm mm kg °C °C
BCD55.1F-01 360 30 21 350 9 M 0.250 5 ... 55 70
BCD55.2F-01 425 30 21 415 9 M 0.355 5 ... 55 70
BCD18.1F-01 360 30 21 350 9 M 0.246 5 ... 55 70
BCD36.1F-01 360 30 21 350 9 M 0.250 5 ... 55 70
BCD58.1F-01 360 30 21 350 9 M 0.260 5 ... 55 70
BCD18.3-4F-01 360 39 21 350 9 M 0.310 5 ... 60 75
BCD18.2F-01 425 30 21 415 9 M 0.325 5 ... 55 70
BCD36.2F-01 425 30 21 415 9 M 0.328 5 ... 55 75
BCD58.2F-01 425 30 21 415 9 M 0.330 5 ... 55 75
Dimensions | weights | temperatures
Case drawingCo
ntro
l gea
r for
FL
Elec
troni
c co
ntro
l gea
rs (d
imm
able
) | B
CD T
8 1-
10V
64
1234
1−10 V
74
12345671−10 V
76
123456
17161514n.c.
–
7
+ 1-10V
77
123456
17161514n.c.
–
7
+ 1-10V
132 133 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Wiring diagrams
Control gear for FLElectronic control gears (dim
mable) | BCD T8 1-10V
132 133 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(dim
mab
le) |
BCD
T8
1-10
V
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
134 135 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCS TCNon-dimmable electronic control gear for CFL, T5 and T8 lamps
Control gear for FLElectronic control gears (non-dim
mable) | BCS TC
• All models in compact housing for space-saving application in luminaires
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350 V / 2 h
Max. leakage current 0.5 mA
Technical dataProduct information Conformity
Designations
11
1234
X1
Y M YZZ M
X M
X
G
134 135 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
BCS
TC
Designation Material number
Lamp designation System rating Input current Operation frequency
136 137 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
• All models in compact housing for space-saving application in luminaires
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350 V / 2 h
Max. leakage current 0.5 mA
Technical dataProduct information
Control gear for FLElectronic control gears (non-dim
mable) | BCS TC Tw
ingle
BCS TC TwingleNon-dimmable electronic control gear for CFL, T5 and T8 lamps with Twingle- Technology
Conformity
Designations
136 137 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency
138 139 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
BCS
TC Tw
ingl
e
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
140 141 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCS TC Twingle IndependentNon-dimmable electronic control gear for CFL, T5 and T8 lamps with Twingle- Technology in independent housing
Control gear for FLElectronic control gears (non-dim
mable) | BCS TC Tw
ingle Independent
• Housing with integrated strain relief and terminal cover, separate for mains power supply and lamp connection
• Plug-in positions for standard terminal blocks designed for easy feed through
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350 V / 2 h
Max. leakage current 0.5 mA
Technical dataProduct information Conformity
Designations
140 141 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
BCS
TC Tw
ingl
e In
depe
nden
t
Designation Material number
Lamp designation System rating Input current Operation frequency
142 143 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Wiring diagrams
Case drawing
31
Control gear for FLElectronic control gears (non-dim
mable) | BCS TC Tw
ingle Independent
142 143 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
BCS
TC Tw
ingl
e In
depe
nden
t
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
Industry
Office & Commercial
Outdoor
Shop
144 145 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350 V / 2 h
Max. leakage current 0.5 mA
Technical dataProduct information
Control gear for FLElectronic control gears (non-dim
mable) | BCS TC Linear
BCS TC LinearNon-dimmable electronic control gear for CFL, T5 and T8 lamps
Conformity
Designations
• Alternative housing to conventional control gear
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology: minimised heat current through electrodes during operation, for optimum light output and reduced power loss.
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Flimmer free light through high frequency lamp operation, no stroboscope effect
• Constant lamp output independent of mains voltage fluctuations
• Optimum ignition safety even at low temperatures: automatic second start if necessary
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Connecting earth can be disregarded in suitable luminaires with safety classification II
• Energy efficiency EEI=A2
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
144 145 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency
150 151 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Control gear for FLElectronic control gears (non-dim
mable) | EBS M
INIPOWER
Short designation Length X Width Y Height Z Hole spacing XM (length direction)
Diagram Weight Ambient tempera-ture ta
Housing tempera-ture tc,max
mm mm mm mm kg °C °C
EBS16.1C-01 80 42 20 70 P 0.053 -20 ... 55 75
EBS21.1C-01 80 42 20 70 P 0.053 -20 ... 55 80
EBS26.1C-01 80 42 20 70 P 0.053 -20 ... 55 80
EBS16.1M-01 150 22 19 140 F 0.050 -20 ... 55 75
EBS21.1M-01 150 22 19 140 F 0.050 -20 ... 55 75
EBS26.1M-01 150 22 19 - F 0.050 -20 ... 55 80
Dimensions | weights | temperatures
Wiring diagramsCase drawing
150 151 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Cont
rol g
ear f
or F
LEl
ectro
nic
cont
rol g
ears
(non
-dim
mab
le) |
EBS
MIN
IPOW
ER
EN 61347-1
EN 61347-2-3
EN 61347-2-3/C
EN 60929
EN 62386-102
EN 61 00-3-2
EN 6100-3-3
EN 61547
EN 55015
push
Industry
Office & Commercial
Outdoor
Shop
152 153 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCD TC DALIDALI dimmable electronic control gear for CFL, T5 and T8 lamps with Twingle-Technology
Control gear for FLElectronic control gears (dim
mable) | BCD TC DALI
• Dim interface: DALI/Push-Dim
• Dim range 3...100% luminous flux
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Suitable for dimming amalgam lamps
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Energy efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350V / 2 h
Overvoltage protection DALI interface 264 V / permanent
Max. leakage current 0.5 mA
Technical dataProduct information Conformity
Designations
88
DADA
123456
Push-DIML N
G
Y
Y
XXm
Ym
152 153 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency
154 155 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCD TC 1-10VDimmable electronic control gear for CFL, T5 and T8 lamps with Twingle-Technology
Control gear for FLElectronic control gears (dim
mable) | BCD TC 1-10V
• Dim interface: 1–10 V
• Dim range 3...100% luminous flux
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Twingle function: operation with 1 or 2 lamps
• Suitable for dimming amalgam lamps
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Energy efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350 V / 2 h
Max. leakage current 0.5 mA
Max. control current (1-10V) 0.2 mA
Technical dataProduct information Conformity
Designations
78
1−10 V
123456
Y
Y
XXm
Ym
G
154 155 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency
156 157 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
BCD CFL and T5-C 1-10VDimmable electronic control gear for CFL and T5-C lamps
Control gear for FLElectronic control gears (dim
mable) | BCD CFL and T5-C 1-10V
• Dim interface: 1–10 V
• Dim range 3...100% luminous flux
• Multi-Power technology for operation of different lamps and wattages on the same ECG
• Suitable for dimming amalgam lamps
• Electrode preserving warm start for maximum lamp life, even at increased switching frequency; starting time < 1.5 s
• Cut-Off technology at 100% luminous flux: minimised heat current through electrodes during operation, for optimum light output and reduced power
• Safety switch-off in case of abnormal lamp operation, e. g. defective electrode and end of lamp life; tested acc. to EN 61347-2-3 + Test 2
• Constant lamp output independent of mains voltage fluctuations
• Automatic restart after lamp replacement
• Suitable for direct current operation and emergency lighting installations; complies with requirements for emergency lighting according to EN 61347- 2-3/J
• Quick restart of lamps after short power disruptions
• Energy efficiency EEI=A1
• Nominal service life: 50.000 h with failure rate of ≤ 10% and operation at tc=tc,max
Mains voltage supply
Rated voltage range 220 ... 240 [V]
Rated frequency 0 / 50 ... 60 [Hz]
Admissible continuous voltage range (AC)
198 - 264 [V]
Battery operation
Voltage range continuous DC 198 VDC - 278 VDC
Voltage short time DC min. 176 VDC
Overvoltage protection (time) 350V / 2 h
Max. leakage current 0.5 mA
Max. control current (1-10V) 0.2 mA
Technical dataProduct information Conformity
Designations
63
1−10 V
1234
73
LN
1−10 V
12345678
78
1−10 V
123456
Y
Z
XXm
Zm
G
156 157 BAG electronics | Product Catalogue 2014Product Catalogue 2014 | BAG electronics
Designation Material number
Lamp designation System rating Input current Operation frequency