1. STORE AND HANDLE ROOFING SHEETS IN A DRY, WELL-VENTILATED, WEATHER-TITE PLACE.STORE ROLLS OF FELT AND OTHER SHEET MATERIALS ON RAISED SURFACE. STAND ALL ROLLMATERIALS ON END. COVER ROLL GOODS WITH A CANVAS TARPAULIN OR OTHERBREATHABLE MATERIAL (NOT POLYETHYLENE).
2. DO NOT LEAVE UNUSED MATERIALS ON THE ROOF WHEN ROOFING WORK IS NOT INPROGRESS UNLESS PROTECTED FROM WEATHER AND OTHER MOISTURE SOURCES.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIAL AND EQUIPMENTON THE JOB SITE. IF ANY MATERIAL OR EQUIPMENT IS STORED ON THE ROOF, THECONTRACTOR MUST MAKE SURE THAT THE INTEGRITY OF THE DECK IS NOT COMPROMISEDAT ANY TIME.
4. DO NOT APPLY ROOFING INSULATION OR MEMBRANE TO DAMP DECK SURFACE.
5. FULLY COMPLETE ALL. MODIFIED BITUMINOUS MEMBRANE ROOFING FIELD ASSEMBLY WORKEACH DAY. PHASED CONSTRUCTION WILL NOT BE ACCEPTED.
CUSTOMER NOTE:
1. ALL OF GARLAND'S SHOP FABRICATED MATERIAL WILL BE MANUFACTURED TO THEDIMENSIONS SHOWN, UNLESS OTHERWISE NOTED.
2. IT IS ESSENTIAL THAT ANY NECESSARY CHANGES, NOTATIONS OR REQUESTEDINFORMATION BE CLEARLY NOTED ON THE SHOP DRAWINGS.
3. NO MATERIAL WILL BE CONSIDERED RELEASED FOR FABRICATION UNTIL ALL PERTINENTINFORMATION (i.e. COLOR, DIMENSIONS, MATERIAL CONFIGURATION) HAS BEEN RECEIVED.
SCOPE OF WORK NOTESTYPICAL ROOF CROSS SECTION DETAIL DESIGN CRITERIA
WIND UPLIFT REQUIREMENTSGENERAL NOTES:
1. IT IS THE ROOFING CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE THEMSELVES WITH ALL DETAILSINVOLVED IN THE ROOFING CONTRACT.
2. ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF EXISTING AND NEWMATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS PRIOR TOCOMMENCEMENT OF WORK.
3. THE ROOFING CONTRACTOR TO PROTECT ALL ADJACENT SURFACES NOT SCHEDULED FOR WORK AND TOREPAIR ANY DAMAGED AREAS AS A RESULT OF CONTRACTOR WORK AT NO ADDITIONAL COST TO THE OWNER.
4. THE ROOFING CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN WATER TIGHTNESS AND PROVIDEPROTECTION AT ANY/ALL OPENINGS IN THE ROOF LEFT AT THE END OF EACH CONSTRUCTION DAY.
5. ALL WOOD BLOCKING SHALL BE PRESSURE TREATED.
6. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONDITIONS, AND QUANTITIES.
SCOPE OF WORK:
1. PROVIDE ALL LABOR, EQUIPMENT AND NON-DISTRICT SUPPLIED MATERIALS TO COMPLETE THE INSTALL OF
A NEW ROOFING SYSTEM.
2. REMOVE AND PROPERLY DISPOSE OF EXISTING ROOF SYSTEM (S) DOWN TO WOOD DECK.
3. REPLACE ALL DRY ROT WOOD DECKING
4. REMOVE AND REPLACE COPING CAP WITH KYNAR 500 COATED METAL.
5. INSTALL RED ROSIN SHEET.
6. INSTALL 2 LAYERS OF POLYISO INSULATION A TOTAL OF R-30
7. INSTALL CRICKETS TO PROVIDE PROPER FLOW TO ALL INTERNAL DRAINS.
9. INSTALL ONE (1) PLY OF STRESSBASE 80 IN GREEN LOCK PLUS MEMBRANE ADHESIVE.
10. INSTALL STRESSPLY PLUS FR MINERAL CAP SHEET IN GREEN LOCK PLUS MEMBRANE ADHESIVE.
11. INSTALL GREEN WELD FLASHING AT ALL PIPE PENETRATIONS
12. APPLY TITLE 24 COMPLIANT COATING PYRAMIC PLUS LO
4 X 8 BOARD PATTERN
RED ROSIN PAPER
STRESSPLY PLUS FRMINERAL CAP SHEET INGREENLOCK PLUSMEMBRANE ADHESIVE
STRESSBASE 80 INGREENLOCK PLUSMEMBRANE ADHESIVE
EXISTING WOODDECK
2 LAYERS POLYISOCYANURATEINSULATION MECHANICALLYFASTENED TO DECKACCORDING TOSPECIFICATIONS.
1/2" COVERBOARDMECHANICALLY FASTENED THRUINSULATION ACCORDING TOWIND UPLIFT CALCS
1. WIND SPEED: 110 MPH
2. EXPOSURE CATEGORY: B
3. IMPORTANCE FACTOR: III
4. DESIGN ROOF HEIGHT: 15.0'
5. ROOF SLOPE: 1/2 UNITS PER 12
RESULTING WIND UPLIFT PRESSURES:
ZONE 1: 20.8 PSFZONE 2: 27.4 PSFZONE 3: 37.4 PSF
ZONES 1, 2, & 3 INSULATION BOARD FASTENER PATTERN: 12 FASTENERS PER BOARD (1:2.67 sqft)
3 SPACES @ 24"
6"
24"
12"
4'
OFSH
EET:
REVI
SION
:
GAR
LAN
D
PHO
NE (8
00) 3
21-9
336
/ FAX
(216
) 641
-063
338
00 E
AST
91st
STR
EET
- CLE
VELA
ND, O
HIO
441
05-2
197
A S
ubsi
diar
y of
Gar
land
Indu
strie
s
Des
ign-
Bui
ld S
olut
ions
, Inc
.ÒG
AR
LAN
D /
DB
S IN
C.
DATE
:CH
K BY
:DW
G BY
:GA
RLAN
D RE
P:
PROJ
ECT
NO:
KING
S BE
ACH
ELEM
ENTA
RY S
CHOO
L ROO
F RE
PLAC
EMEN
T81
25 S
TEEL
HEAD
AVE
, KIN
GS B
EACH
, CA
9614
330
-ES-
2001
3811
.12.20
20TO
SCM
72
TYPICAL ROOF CROSS SECTIONADHESIVE INSTRUCTIONS
GENERAL NOTES
NOTES
1. STORE AND HANDLE ROOFING SHEETS IN A DRY, WELL-VENTILATED, WEATHER-TITE PLACE.STORE ROLLS OF FELT AND OTHER SHEET MATERIALS ON RAISED SURFACE. STAND ALL ROLLMATERIALS ON END. COVER ROLL GOODS WITH A CANVAS TARPAULIN OR OTHERBREATHABLE MATERIAL (NOT POLYETHYLENE).
2. DO NOT LEAVE UNUSED MATERIALS ON THE ROOF WHEN ROOFING WORK IS NOT INPROGRESS UNLESS PROTECTED FROM WEATHER AND OTHER MOISTURE SOURCES.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SECURE ALL MATERIAL AND EQUIPMENTON THE JOB SITE. IF ANY MATERIAL OR EQUIPMENT IS STORED ON THE ROOF, THECONTRACTOR MUST MAKE SURE THAT THE INTEGRITY OF THE DECK IS NOT COMPROMISEDAT ANY TIME.
4. DO NOT APPLY ROOFING INSULATION OR MEMBRANE TO DAMP DECK SURFACE.
5. FULLY COMPLETE ALL. MODIFIED BITUMINOUS MEMBRANE ROOFING FIELD ASSEMBLY WORKEACH DAY. PHASED CONSTRUCTION WILL NOT BE ACCEPTED.
CUSTOMER NOTE:
1. ALL OF GARLAND'S SHOP FABRICATED MATERIAL WILL BE MANUFACTURED TO THEDIMENSIONS SHOWN, UNLESS OTHERWISE NOTED.
2. IT IS ESSENTIAL THAT ANY NECESSARY CHANGES, NOTATIONS OR REQUESTEDINFORMATION BE CLEARLY NOTED ON THE SHOP DRAWINGS.
3. NO MATERIAL WILL BE CONSIDERED RELEASED FOR FABRICATION UNTIL ALL PERTINENTINFORMATION (i.e. COLOR, DIMENSIONS, MATERIAL CONFIGURATION) HAS BEEN RECEIVED.
SCOPE OF WORK NOTESTYPICAL ROOF CROSS SECTION DETAIL DESIGN CRITERIA
WIND UPLIFT REQUIREMENTSGENERAL NOTES:
1. IT IS THE ROOFING CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE THEMSELVES WITH ALL DETAILSINVOLVED IN THE ROOFING CONTRACT.
2. ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF APPROXIMATE LOCATION OF EXISTING AND NEWMATERIALS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS PRIOR TOCOMMENCEMENT OF WORK.
3. THE ROOFING CONTRACTOR TO PROTECT ALL ADJACENT SURFACES NOT SCHEDULED FOR WORK AND TOREPAIR ANY DAMAGED AREAS AS A RESULT OF CONTRACTOR WORK AT NO ADDITIONAL COST TO THE OWNER.
4. THE ROOFING CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN WATER TIGHTNESS AND PROVIDEPROTECTION AT ANY/ALL OPENINGS IN THE ROOF LEFT AT THE END OF EACH CONSTRUCTION DAY.
5. ALL WOOD BLOCKING SHALL BE PRESSURE TREATED.
6. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, CONDITIONS, AND QUANTITIES.
SCOPE OF WORK:
1. TEAR OFF EXISTING ROOF TO DECK
2. CONTRACTOR SHALL IDENTIFY AREAS OF DECK WHICH NEED REPAIR OR REPLACEMENT DURING TEAROFF
3. PROPERLY CLEAN DECK
4. INSTALL (2) LAYERS OF 1” POLYISOCYANURATE INSULATION IN INSUL-LOCK HR INSULATION ADHESIVE
ACCORDING TO WIND UPLIFT CALCULATIONS. STAGGER JOINTS 4'X4' BOARDS
5. INSTALL ½” SIX-SIDED ASPHALT SATURATED COVER BOARD IN INSUL-LOCK HR ACCORDING TO WIND UPLIFT
CALCULATIONS
6. INSTALL STRESSBASE 80 BASE SHEET IN GREEN-LOCK MEMBRANE ADHESIVE
7. INSTALL STRESSPLY PLUS FR MINERAL CAP SHEET IN GREEN-LOCK PLUS MEMBRANE ADHESIVE
8. INSTALL STRESSBASE 80 BASE AND STRESSPLY MINERAL CAP FLASHING IN GREEN-LOCK PLUS FLASHING
ADHESIVE
9. INSTALL GREEN WELD FLASHING AT ALL PIPE PENETRATIONS
10. APPLY TITLE 24 COMPLIANT COATING PYRAMIC PLUS LO.
4 X 4 BOARD PATTERN
STRESSPLY PLUS FRMINERAL CAP SHEET INGREENLOCK PLUSMEMBRANE ADHESIVE
STRESSBASE 80 INGREENLOCK PLUSMEMBRANE ADHESIVE
EXISTING DECK
2 LAYERS POLYISOCYANURATEINSULATION IN INSUL-LOCK HRADHESIVE ACCORDING TOSPECIFICATIONS.
1/2" COVERBOARD ININSUL-LOCK HRACCORDING TO WINDUPLIFT CALCS
1. WIND SPEED: 110 MPH
2. EXPOSURE CATEGORY: B
3. IMPORTANCE FACTOR: III
4. DESIGN ROOF HEIGHT: 15.0'
5. ROOF SLOPE: 1/2 UNITS PER 12
RESULTING WIND UPLIFT PRESSURES:
ZONE 1: 20.8 PSFZONE 2: 27.4 PSFZONE 3: 37.4 PSF
INSULATION BOARD ADHESIVE PATTERN
TYPICAL ASCE 7 WIND PRESSURE ZONES 1, 2, & 3 INSULATION BOARDADHESIVE PATTERN: 12" OC BEADS PER BOARD
NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.
NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.
NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD.
CAP TORCH FLASHING PLY 9" MIN. [228MM] ON FIELD
BASE FLASHING PLY 6" MIN. [152MM] ON FIELD
CANT
SA HIGH TEMP UNDERLAYMENT
2" MIN
V.I.F.
NOTE:REFERENCE SPECIFICATION FOR SURFACING,MEMBRANE ADHESIVE TYPE, AND INSULATION/COVERBOARD TYPE AND ATTACHMENT METHOD. 6" CONCEALED SPLICE PLATE @ EACH