Page 1: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Kinetic Temperature Retrievals from MGS TES Bolometer Measurements:

Current Status and Future Plans

A.A. Kutepov, A.G. Feofilov, L.Rezac

July 28, 2009, NASA GSFC

Page 2: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Outline

• Theoretical approach, algorithm

• Application to real retrievals: problems.

• Methods of solution: separating detectors, re-calibration, etc

• Other possible methods

• Conclusions and future plans

Page 3: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Thermal Emission Spectrometer on MGS Satellite

Spectrometer• Michelson interferometer; spectral range: 1700 – 200 cm-1 (6 – 50 m); spectral sampling: ~5 or ~10 cm-1

Bolometer• Bolometric thermal radiance channel (5.1 – 150 m)• Solar reflectance channel (0.3 – 2.9 m)• Spectral range: 5.1 – 150 m• Tangent heights range: 0~100 km• Single detector FOV: 13 km, however:• 3x2 array of detectors scanned in overlapping steps provide 1-5 km vertical resolution

Array ofdetectors

Page 4: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Bolometric instrumental functionand contributions to signal

Page 5: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Non-LTE in CO2: vibrational temperatures

Page 6: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Forward Radiative Transfer

modelFeedback scheme:

T’(z) = F{Imeas(z), Isimul(z)}

Corrected T(z)

P0 from TES SpectrometerInitial guess for T(z)

Iterations

Non-LTE model

Measured radiance I(z)

Imeas(z) ~ Isimul(z) ?Retrieved T(z)

CO2 populations

I simul(z

)

Imeas(z)

Forward fitting algorithm

Page 7: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Numerical simulation of retrieval process

Page 8: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Real life

• Daytime signal has an unknown pedestal. Moreover, 10m radiance is non-thermal. Considering only nighttime retrievals.

• Straightforward interpretation of nighttime bolometric data produces unrealistic data.

• Calibration of TES bolometer using integrated TES spectrometer.

• Even re-calibrated TES bolometer radiances do not lead to temperature retrievals that would qualitatively agree with the current understanding of Martian atmosphere’s physics.

• Illustrations of these issues will follow.

Page 9: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Examples of day- and nighttime bolometric signals

Page 10: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Day- and nighttime simulations

Page 11: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Very first nighttime temperature retrievals. Ls=0.

Page 12: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Possible reasons?

• Non-LTE issues: not important below ~80km altitude.• Atomic oxygen or KV-T(CO2-O) rate: can not change the signal at 50-60km to be 2-3 times larger while the radiance from 100km remains negligible.• Insufficient number of levels and transitions: tested.• Line parameters uncertainties: this is very unlikely for the fundamental bands.• Offsets in P0 leading to changes in P(z): varied by ~30%, didn’t help.• Possible signal issues: - twilight/night: only “pure night” cases selected - sporadic spikes: filtered out - differences between detectors (gain, latitudinal coverage): checked. Even if we take the “best” detector, it doesn’t help. - absolute values verification: need extra source of information.

Page 13: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Spectral TES as a reference dataset for calibration

Average of the above

Average of the above

Page 14: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Bolometer Spectrometer conversion (by M.Smith)

We are interested in this part

Page 15: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Bolometer Spectrometer conversion tables

Page 16: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Bolometer Spectrometer conversion tables

Page 17: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

“Best achievement”: temperature distribution for Ls=0

Page 18: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Comparing with other measurements

TES Spectrometer

Ls=0

MCS Ls=330

Page 19: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Even less realistic: temperature distribution for Ls=90

Page 20: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Reasons for retrieving increased T

Page 21: Kinetic Temperature Retrievals from MGS TES Bolometer Measurements: Current Status and Future Plans A.A. Kutepov, A.G. Feofilov, L.Rezac July 28, 2009,

Possible ways of solving the problem

• Continue further attempts of re-calibrating bolometer.

• Switch to spectrometer and work with integrated signal.

Questions:

• What do we call an “integrated spectrometer”?

• Will the integrated spectrometer go above 60km?

• How good are MGS TES limb retrievals compared to retrievals from nadir observations?