J u n c t i o n B o x e s I n s t a l l a t i o n M a n u a l Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com Perimeter Intruder Detection System Sensing Junction Box and Terminal Junction Box Installation Manual
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Jun
ction
Bo
xes Installatio
n M
anu
al
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
Sensing Junction Box and Terminal Junction Box Installation Manual
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
2
Jun
ction
Bo
xes Installatio
n M
anu
al
INTRODUCTION
All Nxtar’s Junction Boxes are made of ABS + Polycarbonate material to withstand the harshest outdoor conditions and to meet the customer’s requirements. Using our plug and play design, there is no need for expensive splicer and fusing during installation which saves installation cost and time.
In this manual we illustrate the connections from the Leading Fiber to the Sensing Junction Box, and from the Sensing Fiber to their respective Terminal Junction Boxes. From the step-by-step instructions, the SI or Authorized Installer should be able to perform all the installation for the outfield components.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
4
Step1. Insert a fiber into the port labeled “SF1”. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels.
SENSING JUNCTION BOX INSTALLATION
Jun
ction
Bo
xes Installatio
n M
anu
al
Sensing Fiber
1 Core
Branch head is located at red point
Step2. Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
5
SENSING JUNCTION BOX INSTALLATION
Jun
ction
Bo
xes Installatio
n M
anu
al
Step3. Remove the cap of the “SF1” adaptor and prepare for connections.
Step 4. Remove the cap of connector (see the picture below).
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
6
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Step6. The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 loops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise.
Step5. Connect the connectors “SF1” as follows. The fiber must be tucked gently into the box, no fragments of the fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
7
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Step7. No fragment of fiber should be protruding out of the box.
Fiber in the right position
Step8. Insert a fiber into the port labeled “SF2”. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels.
Sensing Fiber
1 Core
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
8
Step10. Remove the cap of the “SF2” adaptor and prepare for connections.
Step9. Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling.
Brach head is located at green point
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
9
Step11. Remove the cap of connector (see the pictures below).
Step12. Connect the connectors “SF2” as follows. Both fibers must be tucked gently into the box, no fragment of any fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
10
Step14. No fragment of any fiber should be protruding out of the box.
Fiber is in the right position
Step13. The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 l oops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
11
Step16. Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling.
Branch head is located at yellow point
Step15. Insert a fiber into the port labeled “LF”. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels.
Leading Fiber
2 Core
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
12
Step18. Remove the caps of the connectors (see picture below).
Step17. Remove the cap of the “LF” adaptor and prepare for connections.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
12
Step20. The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 loops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise.
Step19. Connect the connectors “LF” as follows. The fiber must be tucked gently into the box, no fragment of fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
13
Step22. Clean o-ring of the box and seal of upper cover. Cover it finally.
Step21. No fragment of fibers should be protruding out of the box.
Fiber is in the right position
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
14
Step24. Take out water resistant tape for next step.
Step23. Tightened the cover with a screw driver or electric screwdriver in
the sequence as shown.
1
2
6
5
7
8
3
4
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
15
Step26. Entwine the cap and fiber with tape. Overlapping entwine is needed at 2/3 width of the tape. (See pictures below)
Step25. Wrap from bottom of cap and it stretches 2/3 width as original.
Original WidthWidth after Stretching
Original Width
2/3 of widthOverlapped.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
16
Step27. Keep tape and fiber clean. Notice whether dust is on the fiber or not .
Step28. After entwining, the tail of tape must be tightened with the fiber. Make sure the joint is complete tight. Extra care needs to be taken when pressing the fiber. Never bend the fibers at sharp angels.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alSENSING JUNCTION BOX INSTALLATION
Perimeter Intruder Detection System
17
Step29. Tape other caps in the similar manner
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Jun
ction
Bo
xes Installatio
n M
anu
alPerimeter Intruder Detection System
18
TEMINAL JUNCTION BOX
Step1. Insert a fiber into the port. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels.
Step2. Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling.
Branch head location
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
19
Jun
ction
Bo
xes Installatio
n M
anu
alTEMINAL JUNCTION BOX
Step4. Remove the cap of connector (see the picture below).
Step3. Remove the cap of Adaptor
Enlarged
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
20
TEMINAL JUNCTION BOX
Jun
ction
Bo
xes Installatio
n M
anu
al
Step6. The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 loops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise.
Step5. Connect the connectors as follows. The fiber must be tucked gently into the box, no fragment of fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
21
TEMINAL JUNCTION BOX
Jun
ction
Bo
xes Installatio
n M
anu
al
Step8. Clean o-ring of the box and joint of upper cover. Cover it finally.
Step7. No fibers should be protruding out of the box.
Fiber is in the right position
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
22
TEMINAL JUNCTION BOX
Jun
ction
Bo
xes Installatio
n M
anu
al
Step10. Take out water resistant tape for next step.
Step9. Tightened the cover with a screw driver or electric screwdriver in the sequence as shown. Check whether the box is seamless.
1
2
3
4
5
6
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
23
TEMINAL JUNCTION BOX
Jun
ction
Bo
xes Installatio
n M
anu
al2/3 of width Overlapped.
Original Width
Step11. Wrap from bottom of cap and it stretches 2/3 width as original.
Original Width
Width after Stretching
Step12. Entwine the cap and fiber with tape. Overlapping entwine is needed at 2/3 width of the tape. (See pictures below)
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
24
TEMINAL JUNCTION BOX
Jun
ction
Bo
xes Installatio
n M
anu
al
Step14. After entwining, the tail of tape must be tightened with the fiber. Make sure the joint is complete tight. Extra care needs to be taken when pressing the fiber. Never bend the fibers at sharp angels.
Step13. Keep tape and fiber clean. Notice whether dust is on the fiber or not .
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
25
TEMINAL JUNCTION BOX
Jun
ction
Bo
xes Installatio
n M
anu
al
Step15. Completed the assembly.
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
Website: www.nxtar.com
Perimeter Intruder Detection System
Junction Box Installation
Cleaning Of Connectors
Use only Kimtech Science KIMWIPES (or similar)And 99% Alcohol to clean all Connectors.
Apply the alcohol onto the Kimwipes and clean the SC/ APC connectors thoroughly.Take note as not to touch the wet part of the Kimwipes with your hand
Jun
ction
Bo
xes Installatio
n M
anu
al
26
Perimeter Intruder Detection System
DIMENSION
Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan