Ivan Rech Politecnico di Milano MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003 MICROELECTRONIC PHOTOSENSORS MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 I. Rech ; S. Cova; F. Zappa; M. Ghioni Politecnico di Milano - DEI, piazza. Leonardo da Vinci 32, 20133 Milano, Italy M. Chiari; M. Cretich CNR - ICRM, via M. Bianco, 20133 Milano
24
Embed
Ivan Rech Politecnico di Milano MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003, June 13, 2003 MICROELECTRONIC PHOTOSENSORS FOR.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
• Well defined high-field region
• No edge effects
• No microplasmas
• Low generation rate
• Minimum afterpulsing effect
• Low series resistance
• Low cost process
• Low Power dissipation
n
p++p
p
hv
+n
anode cathode
Planar SPAD structure
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
High QE (Quantum detection Efficiency)
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
0
5
10
15
20
25
30
35
40
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Sovratensione (V)
Cont
eggi
di B
uio
(cou
nts/
sec.
)
100
150
200
250
300
350
400
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Sovratensione (V)Co
nteg
gi d
i Bui
o (c
ount
s/se
c.)
Active area diameter : 10 Active area diameter : 10 mm Active area diameter : 20 Active area diameter : 20 mm
Low internal noise : Dark Counts
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Dark Counts Vs Temperature
0
50
100
150
200
250
300
350
-30 -20 -10 0 10 20
Temperature [C°]
Da
rk C
ou
nts
[c
/s]
+5V
+10V
0
50
100
150
200
250
300
350
-30 -20 -10 0 10 20
Temperature [C°]
Da
rk C
ou
nts
[c
/s]
+5V
+10V
Experimental set-up
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Fragment separation
Electropherogram
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Counting Module
• Single power supply +5V• Software controlled settings• RS-232 data transmission• Fmax 6.5 MHz• Waveform storage
Politecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
SeparationInjection
Sample
Buffer
Waste
Chip Electrophoresis
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
First Experimental Setup
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Current Apparatus : SV3
• Compact and low-cost
• Full automated
• Laser diode for fluorescence excitation
• Controlled chip temperature
• Dual wavelength electropherogram
• Dual HV power supply (0-5kV)
• Confocal optical scheme
• Remote control and problem debug
(via internet)
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Results
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
121416181101121141161181
0
10000
20000
30000
40000
50000
60000
70000
80000
Static measure5ng/ul
0,5ng/ul
0,05ng/ul
100pM oligonucleotide labelled with CY 5
300
400
500
600
700
800
900
1000
1100
1200
1300
0 50 100 150 200Time [Sec.]
Co
un
ts [
c/s]
S/N=35
• Glass microchips purchased from Micralyne Inc. (Edmonton, Canada).• Electrosmotic flow in the separation channels suppressed by EPDMA • dynamic coating . • Separation run buffer: TAPS-TRIS 100mM pH 8.5.• Sample :23 mer oligonucleotide labelled with CY 5
• Detection limitDetection limit ( with S/N=3) :( with S/N=3) : 3pM3pM (with injection volume 50pL)
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
SPTM- Single Photon Timing Module
• Single power supply +15V• High Time-resolution (60ps) • Low dark Counts (down to 5 c/sec)• Controlled Temperature
• Software controlled settings• RS-232 data transmission
Politecnico di Milano
Single Molecole Detection Collaboration with S.XieHarvard Univ. Dept. Chemistry and Chemical Biology
FWHM=60ps
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Prospect
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
• Improved optics sensitivity enhancement to 100fM
• Wider-area SPAD simpler set-up
• monolithic SPAD&AQC micro-miniaturized detection head
• SPAD arrays elaborate detection head
Prospect
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003
Acknowledgments
Politecnico di Milano, Italy
Alessandro Restelli Electronics & Optics
Ivan Labanca
Dario Vagni
Giuseppe Liaci
Fabrizio Mingozzi ICRM-CNR, Milano, Italy:
Marcella CHIARI Polymers & Electrophoresis
Marina CRETICH
CEQSE-CNR, Milano, Italy:
Luciano PALLARO Mechanics & Optics
Ivan RechPolitecnico di Milano
MICROELECTRONIC PHOTOSENSORS FOR GENETIC DIAGNOSTIC MICROSYSTEMS GE 2003 , June 13, 2003