This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MASONRY BUILDINGS MASONRY BUILDINGS OF FOR IN MASONRY BUILDINGS Submitted by ADL BARAN ÇOBANOLU in partial fulfillment of the requirements for the degree of Master of Science in Civil Engineering Department, Middle EastTechnical University by, Prof. Dr. Canan Özgen Prof. Dr. Ahmet Cevdet Yalçner Head of Department, Civil Engineering Prof. Dr. Bar Binici Examining Committee Members Civil Engineering Dept., METU Civil Engineering Dept., METU Date: 29.08.2014 iv I hereby declare that all information in this document has been obtained and presented in accordance with academic rules and ethical conduct. I also declare that, as required by these rules and conduct, I have fully cited and referenced all material and results that are not original to this work. Name, Last name: Adil Baran, Çobanolu Signature : v ABSTRACT MASONRY BUILDINGS August 2014, 100 pages Unreinforced masonry construction is still widespread among many urban and rural areas, in developing countries such as Turkey. In order to prevent any loss of lives during an earthquake, ensuring the safety of these buildings is crucial. The buildings which are located in earthquake prone regions should be investigated and assessed so that necessary precautions can be taken. Therefore, several questions and concerns regarding the application of the assessment procedure, the assumptions and risk decision for the current methods of masonry building assessment are raised. This thesis addresses these concerns and investigates the material characteristics of masonry buildings in Turkey and its effect on assessment methods. In this regard, ten buildings were selected for the study and detailed information were collected on the field regarding the selected buildings. After that, preliminary assessments were conducted on the selected buildings according to the method described in RBTEIE (2013) and the results were evaluated. Then, axial compression, diagonal tension and sliding shear tests were conducted in the laboratory, on the wall specimens obtained from the selected buildings. The test results were discussed along with the comparison vi with the strength values given in TEC (2007) and new material characteristics for masonry buildings were recommended accordingly. Finally, assessment methods described in TEC (2007) and RBTEIE (2013) were conducted to the selected buildings with different material characteristics for all the earthquake zones. The assessment results showed that, the assessments conducted with the allowable stress values provided by TEC (2007) might lead to inaccurate and unsafe results. Keywords: Masonry, Material Properties, Assessment vii ÖZ NCELENMES Tez Yöneticisi : Prof. Dr. Bar Binici Austos 2014, 100 sayfa Donatsz yma yaplar, Türkiye gibi gelien ülkerlerin kentsel ve krsal alanlarnda hala yaygn olarak kullanlmaktadr. Olas bir deprem durumunda can kaybn önlemek adna bu gibi binalarn güvenliini salamak çok önemlidir. Bu yüzden, ileri deprem bölgelerindeki binalarn incelenip deerlendirilmesi ve gerekli önlemlerin alnmas arttr. Bu balamda binalarn deerlendirilmesi ve deerlendirme srasnda yaplan varsaymlar hakknda çeitli sorular ve endieler ortaya çkmaktadr. Bu tez, belirtilen endieleri ele alarak Türkiye’deki yma yaplarn malzeme özelliklerini inceleyip bu özelliklerin risk deerlendirme methodlar üzerindeki etkisini aratrmaktadr. Bu kapsamda, çalma için on bina seçilmi ve binalar hakknda detayl bilgi saha çalmalaryla toplanmtr. Öncelikle bütün binalar için RBTEIE’de belirtilen yöntemle (2013) ön deerlendirme yaplmtr ve sonuçlar irdelenmitir. Daha sonra, laboratuar ortamnda sahadan alnan numuneler üstünde eksenel basnç, diyagonal çekme ve kayma deneyleri yaplmtr. Deney sonuçlar, DBYBHY’de (2007) verilen dayanm deerleriyle karlatrlarak incelenmi ve yeni viii malzeme özellikleri önerilmitir. Son olarak, seçilen binalarn farkl malzeme özellikleri ve farkl deprem bölgeleri için DBYBHY (2007) ve RBTEIE’de (2013) belirtilen yöntemle detayl deerlendirmeleri yaplmtr. Deerlendirme sonuçlar, DBYBHY’de (2007) verilen malzeme özellikleri kullanldnda hatal ve güvenli olmayan sonuçlarn ortaya çkabilieceini göstermektedir. Anahtar Kelimeler: Yma Bina, Malzeme Özellikleri, Risk Deerlendirmesi ix x ACKNOWLEDGEMENTS This study was carried out under the supervision of Prof. Dr. Bar Binici and I would like to express my deepest gratitude to him for his support, guidance, criticism, patience, encouragement throughout this study and above all, for not giving up on me. This thesis benefited from the invaluable suggestions of Assoc. Prof. Dr. Erdem Canbay and I would like to thank him for sharing his insight and experiences. I am grateful to all M.S. examination committee members Prof. Dr. Ahmet Yakut, Prof. smail Özgür Yaman and Asst. Prof. Dr. Ramazan Özçelik for their positive feedback. I would like to thank the Ministry of Environment and Urbanization for their support. I would like to express my gratitude to Hasan Metin, who taught everything I know in the structural mechanics laboratory. I am also grateful to our technicians in structural mechanics laboratory for their help throughout this study. I would like to thank my roommates Alper Aldemir, smail Ozan Demirel and Erhan Budak for their help and friendship. I felt lucky working with such great colleagues. I would like to thank specially to ‘Ankara Crew’: Miran Dzabic, Pnar Berberolu, Ylgün Gürcan, Onur Can Sert, Su Ertürkmen, Cihan imek, Murat Ayhan, Sinem Laçin and Selçuk Öksüz for their great moral support and friendship through this challenging process. I have been very fortunate to have such amazing friends. I would also like to thank my dear friends Egemen Çam, Ece Boyacolu, Çaatay Hanedan, Bar Hackerimolu, Kayra Ergen, Erturul Gören, lke Gören, Ufuk Çalkan, Tuçe Güney, Nilay Doulu and Ava Bagherpoor for their invaluable friendship throughout the years. I owe a special thanks to Oya Memlük, who was there for me when I needed the most. Thank you so much for everything. Last but upmost, I would like to thank my whole family and especially my parents Aye and Sezai Çobanolu to whom this thesis is dedicated to. It would not be possible to finish this thesis without their love and endless support. xi 2 BUILDING INFORMATION ....................................................................... 11 2.3 Preliminary Assesment of the Buildings ................................................. 33 3 MATERIAL TESTING ................................................................................. 35 3.2 Laboratory Tests ...................................................................................... 36 3.2.1 Compression Tests ........................................................................... 38 3.3 Discussion of Results and Recommendations ......................................... 80 xii EXAMINED BUILDINGS .................................................................................... 85 4.1 General ..................................................................................................... 85 4.2 Assessment Method of Masonry Buildings described in RBTEIE (2013) and TEC (2007) .................................................................................................. 86 5 CONCLUSION .............................................................................................. 95 5.1 Summary .................................................................................................. 95 5.2 Conclusions .............................................................................................. 96 Table 2.2 Detailed information about Building 1 ...................................................... 14 Table 2.3 Detailed information about Building 2 ...................................................... 16 Table 2.4 Detailed information about Building 3 ...................................................... 18 Table 2.5 Detailed information about Building 4 ...................................................... 20 Table 2.6 Detailed information about Building 5 ...................................................... 22 Table 2.7 Detailed information about Building 6 ...................................................... 24 Table 2.8 Detailed information about Building 7 ...................................................... 26 Table 2.9 Detailed information about Building 8 ...................................................... 28 Table 2.10 Detailed information about Building 9 .................................................... 30 Table 2.11 Detailed information about Building 10 .................................................. 32 Table 2.12 Preliminary assessment results................................................................. 34 Table 3.1 Test results ................................................................................................. 59 Table 3.2 Allowable compressive stress values of walls (TEC, 2007) ...................... 80 Table 3.3 Allowable shear stress values of walls (TEC, 2007) ................................. 80 Table 3.4 Comparison of test results with the values given in TEC (2007) .............. 81 Table 3.5 Recommended strength values based on masonry unit types .................... 82 Table 4.1 Material strengths used for the assessment ................................................ 88 Table 4.2 Assessment results consdering the buildings’ actual earthquake zone ...... 89 Table 4.3 Assessment results using the material strengths from the laboratory tests 90 Table 4.4 Assessment results using the material strengths provided by TEC (2007) 90 Table 4.5 Assessment results using the recommended material strengths................. 90 Figure 3.1 Examples from specimen removal process ............................................... 36 Figure 3.2 Displacement based test machine ............................................................. 37 Figure 3.3 Axial compression test setup .................................................................... 39 Figure 3.4 Building 1 compression test results along the axis parallel to the load bearing direction of the wall ....................................................................................... 41 Figure 3.5 Building 1 compression test results along the axis parallel to the load bearing direction of the wall ....................................................................................... 42 Figure 3.6 Building 1 compression test results along the axis perpendicular to the load bearing direction of the wall ....................................................................................... 43 Figure 3.7 Building 2 compression test results along the axis parallel to the load bearing direction of the wall ....................................................................................... 44 Figure 3.8 Building 2 compression test results along the axis perpendicular to the load bearing direction of the wall ....................................................................................... 45 Figure 3.9 Building 3 compression test results along the axis parallel to the load bearing direction of the wall ....................................................................................... 46 xv Figure 3.10 Building 3 compression test results along the axis perpendicular to the load bearing direction of the wall ...................................................................................... 47 Figure 3.11 Building 4 compression test results along the axis parallel to the load bearing direction of the wall ...................................................................................... 48 Figure 3.12 Building 4 compression test results along the axis perpendicular to the load bearing direction of the wall ...................................................................................... 49 Figure 3.13 Building 5 compression test results along the axis parallel to the load bearing direction of the wall (Cellular concrete block) ............................................. 50 Figure 3.14 Building 5 compression test results along the axis parallel to the load bearing direction of the wall (Adobe) ........................................................................ 51 Figure 3.15 Building 6 compression test results along the axis parallel to the load bearing direction of the wall ...................................................................................... 52 Figure 3.16 Building 6 compression test results along the axis perpendicular to the load bearing direction of the wall ...................................................................................... 53 Figure 3.17 Building 7 compression test result along the axis parallel to the load bearing direction of the wall ...................................................................................... 54 Figure 3.18 Building 8 compression test results along the axis parallel to the load bearing direction of the wall ...................................................................................... 55 Figure 3.19 Building 9 compression test results along the axis parallel to the load bearing direction of the wall ...................................................................................... 56 Figure 3.20 Building 9 compression test results along the axis perpendicular to the load bearing direction of the wall ...................................................................................... 57 Figure 3.21 Building 10 compression test results along the axis parallel to the load bearing direction of the wall ...................................................................................... 58 Figure 3.22 Steel loading shoe ................................................................................... 60 Figure 3.23 Diagonal tension test setup ..................................................................... 61 Figure 3.24 Building 1 diagonal tension test results .................................................. 63 Figure 3.25 Building 2 diagonal tension test results .................................................. 64 Figure 3.26 Building 3 diagonal tension test results .................................................. 65 Figure 3.27 Building 4 diagonal tension test result ................................................... 66 Figure 3.28 Building 5 diagonal tension test results .................................................. 67 Figure 3.29 Building 6 diagonal tension test results .................................................. 68 xvi Figure 3.30 Building 7 diagonal tension test result .................................................... 69 Figure 3.31 Building 8 diagonal tension test result .................................................... 70 Figure 3.32 Building 9 diagonal tension test results .................................................. 71 Figure 3.33 Building 10 diagonal tension test result .................................................. 72 Figure 3.34 The cutting of the cap to eliminate its contribution to shear strength ..... 73 Figure 3.35 Sliding shear test setup ........................................................................... 74 Figure 3.36 Building 1 triplet test results ................................................................... 75 Figure 3.37 Building 2 triplet test results ................................................................... 75 Figure 3.38 Building 3 triplet test results ................................................................... 76 Figure 3.39 Building 4 triplet test results ................................................................... 76 Figure 3.40 Building 6 triplet test results ................................................................... 77 Figure 3.41 Building 7 triplet test results ................................................................... 77 Figure 3.42 Building 8 triplet test results ................................................................... 78 Figure 3.43 Building 9 triplet test results ................................................................... 78 Figure 3.44 Building 10 triplet test results ................................................................. 79 Figure 3.45 Relationship between shear strength and compressive strength ............. 83 Figure 3.46 Relationship between diagonal tension strength and compressive strength .................................................................................................................................... 83 Figure 3.47 Relationship between the modulus of elasticity and compressive strength .................................................................................................................................... 84 1 CHAPTER 1 1 INTRODUCTION 1.1 Introduction From the beginning of the civilized human life, one of the most basic needs had been sheltering. It had been essential for people in terms of protection from both the wild life and the nature. Being the only construction alternative at the time, masonry construction had been the easiest way to fulfill the need. From simple cottages to complex structures, the use of unreinforced masonry governed the construction industry through centuries. Contemporarily, unreinforced masonry (URM) construction is still widespread among urban and rural areas. Due to the reasons such as the availability and durability of materials, low cost and maintenance, reasonable insulation performance and most importantly, constructing with little engineering knowledge enabled masonry construction to maintain its popularity, especially for residential buildings (Hendry, 2001). Most of the residential building stock is composed of masonry structures all over the world. In developing countries such as Turkey, the amount of masonry construction was quite high in the midst of 20th century and started decreasing towards the end of the century. A report prepared by the Housing Development Administration of Turkey states that in urban areas, 48% of all buildings are brick masonry or timber framed, while 30% of them are reinforced concrete frame type, and 22% are made from adobe or rubble masonry. In rural areas the rate of any kind of masonry buildings for housing increases to 82% (Erdik and Aydnolu, 2002). 2 Although masonry construction is widespread among many areas, it comes with several drawbacks. According to Arya et.al, (1986) most of the masonry construction is conducted without any engineering knowledge and guidance. Since more than 90% of the population in the Middle East is still living and working on such buildings that are in the moderate or severe seismic zones as exhibited by the past experience most of the live losses occurred due to the collapse of such buildings during earthquakes such as Elaz (Turkey, 2010), Bam (Iran, 2003) and Kashmir (Pakistan, 2005) earthquakes. The rising population in the developing countries along with deficiency of traditional building materials and construction techniques, lack of awareness and necessary skills, are the main causes of the risk to the human life especially in developing countries. In this retrospect, ensuring the safety of these buildings during an earthquake is crucial in order to prevent any loss of lives. The buildings that are located in earthquake prone regions, should be investigated and assessed so that necessary precautions can be taken beforehand. Depending on the assessment results, the buildings that are under high earthquake risk should either be strengthened to resist expected earthquakes in that region or renewed completely. After the devastating earthquakes that resulted with the loss of thousands of lives in Turkey, the importance given to the assessment and renewal of existing masonry buildings increased dramatically. The implementation of new codes Turkish Earthquake Code (TEC, 2007) and Guidelines for the Assessment of Buildings under High Risk (RBTEIE, 2013) as per Law no. 6306 gave a better understanding for the assessment of existing structures. In these documents, the assessment techniques for existing reinforced concrete buildings are provided in details whereas the assessment of masonry buildings are conducted with rather less accurate and more primitive methods. The assessment process often results with the renewal of the existing buildings and urban renewal projects became widespread along the country due to the economical benefits rather than the consciousness of reducing seismic risk, which in turn is the achieved objective. The popularity of the urban renewal projects, increased the importance of the assessment methods, while raising several questions and concerns regarding the application of the procedure, the assumptions and risk decision for the current methods of masonry building assessment. 3 One of the main concerns about the assessment procedure for an existing masonry building is the determination of the material properties while assessing the capacity of the walls. A better understanding of the material characteristics of masonry is essential since it may lead to more accurate assessment results. At this point, TEC (2007) provides allowable stress values to be used if the capacity values cannot be obtained through experiments conducted on the existing building. TEC (2007) recommended values which depend on the masonry type. Unit compressive strength and mortar class are specified, while the allowable compressive and shear strength values of walls are also presented depending on the masonry unit type. Currently, those tabularized allowable stress values are used as the material strength values in the assessment of all of the existing masonry buildings. This situation obviously calls for a detailed investigation of the accuracy and safety of the reported material strength values. 1.2 Literature Review Many researchers studied masonry material characteristics, their correlation to each other and factors affecting these properties. The easiest method to determine the material characteristics of masonry is to perform appropriate laboratory tests on specimens constructed with the exact same ingredients that are used on the building site. Although this method provides reliable test results, the accuracy and possibility of finding such specimens are questionable for existing masonry buildings. Therefore, conducting experiments on specimens obtained from actual buildings provide a better understanding of the material properties of existing buildings. There are numerous publications on testing of masonry walls to obtain material strength along with many numerical simulation results with various levels of sophistication. A brief review of the literature conducted on both laboratory and in-situ material tests of masonry walls are discussed in the following paragraphs. Several codes implement methods to determine the material characteristics of the masonry walls. For the determination of the compressive strength, FEMA 356 (2000) and Eurocode 6 (2005) recommends to use one of the following methods: i)testing of prisms that are extracted from the existing walls, ii) testing of prisms that are fabricated 4 from actual extracted masonry units or iii) estimating the compressive strength using flatjack compression tests. If none of the tests are available, FEMA 356 (2000) provides default lower bound compressive strength values varying between 2.1 MPa and 6.2 MPa depending on the quality of the masonry condition, while Eurocode 6 (2005) gives equations based on the masonry unit and mortar to calculate the compressive strength of masonry. In order to determine the shear strength of masonry walls, both FEMA 356 (2000) and Eurocode 6 (2005) recommends to use an in-situ shear test. If the test is not applicable, FEMA 356 (2000) provides default lower bound shear strength values varying between 0.09 MPa and and 0.16 MPa depending on the observed masonry condition. On the other hand, Eurocode 6 provides shear strength values depending on masonry unit and mortar class that varies from 0.10 MPa to 0.30 MPa. Gumaste et al., (2006) investigated the properties of brick masonry using 2 types of bricks from India with various types of mortars. The strength and elastic modulus of brick masonry under compression were evaluated. In order to observe the size effect and different bonding arrangements, various sizes of prisms and wallettes were tested and the failure mechanisms were observed. Combination of four types of masonry specimens using table moulded bricks and wire-cut bricks with three different types of mortar were tested. The compressive strength values varied between 0.67 MPa and 3.18 MPa for the moulded brick masonry while the compressive strength varied between 5.3 MPa and 14.9 MPa for the wire-cut brick masonry. For the first type of specimens the modulus of elasticity varied between 260 and 735 MPa. On the other hand, the modulus of elasticity values were observed in a range of 2393-5232 MPa. Different failure modes were observed between different types of specimens. Empirical relationships for masonry strength depending on brick and mortar strength were derived as the main result of the study. Russell (2010), studied the characterization and seismic assessment of unreinforced masonry buildings in order to develop a better understanding of the response of URM buildings. During the study, Russell (2010), also investigated the diagonal tension (shear) strength of unreinforced masonry having different mortar properties and bond patterns. A total of nine diagonal tension tests were conducted and the results showed that the capacities were between 0.04 MPa and 0.5 MPa. Even when the mortar type 5 and other variables were kept constant, the results indicated a significant variation in the diagonal tension strength of the wall panels. The modulus of elasticity values were also reported and they varied from 1960 MPa to 2560 MPa. These experiment results along with some other…