Page 1: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Telemetry ModulesQuick Start

Page 2: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Necessary Software

Microsoft Framework 1.1 MTManager MT-Data Provider v2.4 Mod-Dog Softing OPC or other OPC client

All programs should be installed with default settings

Page 3: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

3. Add new module right-clicking on project name

1. Run MTM

2.

2. Enter project name

Page 4: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

4. Enter module name and chose type and firmware

Tip:If you don’t know which firmware version do you have, choose the default one. During reading or writing configuration MTM will point you the right one. Then use Change version option from right click menu to correct settings.

Page 5: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

5. Choose General from Device list In SIM card PIN number field enter PIN card number that you

plan to use. Make sure that Use of GPRS option is set to “Yes”

Page 6: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

6. Click GPRS in Device list. Enter your APN name, APN user name and APN login password if required.

Page 7: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

7. Expand Authorized numbers in Device list and choose IP subcategory. Enter IP Number of SIM card that will be used in module connected to the PC.

Page 8: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

8. Click Resources in Device list and check Internal resources Modbus ID number. Here you can be set ID number allowing

access to the module internal resources from Modbus net.

Page 9: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

9. Connect MT-301 to PC using RS cable

10. Click Environment button

11. Choose your COM port number and apply by clicking Write

Page 10: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

11. Click Connect to establish connection

12. Make sure your SIM card is installed. Then click Write and watch the progress bar.

Configuring MT-301 with MTM

13. Accept by clicking OK

Page 11: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Configuring MT-301 with MTM

14. After a while module sholud log on to the APN. Such state is sygnalized by LEDs on module cover. They should blink like below.

Page 12: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

15. Add new module MT-202

Configuring MT-202 with MTM

16. Enter PIN and set Modem operating mode in General

17. Choose Transmision speed in Resources/Serial port, connect MT-202 and Write the configuration

Page 13: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Add hardware in Windows Control Panel

18. In Control Panel click Add Hardware

19. Add new modem to the operating system

Page 14: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Dial-up configuration

20. In Control Panel click „Network Connection”

21. Create a new connection

Enter acces numberEnter name of connection

Enter user name and password if needed

Page 15: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Dial-up configuration

22. Connect MT-202 with PC using port 2 Tips: If the dial-up connectionhave failed, you can forcehandshake on the COM portfrom PC side:

23. Click on APN icon

24. Click Properties

Page 16: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

Dial-up configuration

25. In the bookmark Options change„Redialing options”

26. In the bookmark NetworkingChose TCP/IP protocol andClick Properties button

27. Click „Advanced” button

28. Uncheck „use default gateway…”checkbox

After that click 3 times „OK” and DIAL then you will see:

Page 17: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

MT- Data Provider – first steps

29.After installation go to destination directory: ”C:\Program Files\InVentia\MTopc2\” and open „sample.xml” in NOTEPAD

30.First step is to change default sample.xml file. You must enter IP numbers of remote module (MT-301)

31.Next move is entering IP number of SIM card that is mounted in the MT-202 module.

32. Here you should to put correct type of the module 33.In that area you configure what data you can read from or write toremote module. Default ID modbus is „1” just like in MTM.

Tip:

You can find moreinfo about XMLparameters inreadme.pdf locatedin MT Data Provider folder.

34. Now you can save and close sample.xml

Page 18: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

MT- Data Provider – first steps

35. From Start/All programs/Softing OPC toolbox… run Softing OPC.

32. Double Click on MT-OPC server will start driver33. Left click od DA Browse bookmark and right click on server IDAnd left click on „Add Item for all tags”

36. Click on the DA items bookmarks

Page 19: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reserved

MT- Data Provider – first steps

37.Here you will see quality good for all configured tags in sample.xmlFor example „device—slave.BO0” is the binary output Q1Enter ‘1’ in this field and click write to send ‘1’ to the remote module

Page 20: Inventia sp. z o.o. All rights reserved Telemetry Modules Quick Start.

Inventia sp. z o.o. All rights reservedInventia sp. z o.o. All rights reserved

Congratulations!!!

You have configured your first telemetry system based You have configured your first telemetry system based

on module on module MT-MT-301301 produced by produced by InInVVentiaentia !!! !!!