Top Banner
Instruments O&G tony 2010 mbbs 1
78

Instrumentsog 141019193014-conversion-gate02 3

Aug 12, 2015

Download

Health & Medicine

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Instrumentsog 141019193014-conversion-gate02 3

Instruments O&G

tony 2010 mbbs 1

Page 2: Instrumentsog 141019193014-conversion-gate02 3

Specula

tony 2010 mbbs 2

Page 3: Instrumentsog 141019193014-conversion-gate02 3

Sims bivalvedspeculum

• 2 blades & handle• Adv

• retracts posterior vaginal wall• The groove in the center also drains the

secretion or bleeding thus keeping the area dry

• Disadv• Not self retaining (need an assistant to hold

speculum )

• Enter laterally • PGE1 introduction• Uterine prolapse • FC,D&C,cervical punch bipsy• Pap smear• Push bladder in VH

tony 2010 mbbs 3

Page 4: Instrumentsog 141019193014-conversion-gate02 3

Uses

• Use in Gynae OPD for following procedures : Taking Pap Smear , Insertion and removal of Copper T , Colposcopy ,Taking swabs, Hyseterosalpingography (HSG)Use in Gynae Operations : D&C , Cervix Biopsy , Vaginal Hysterectomy , Fothergills Operation, Repair of Vesico vaginal fistula, Hysteroscopy.Use in Obstetrics : For inspection ( Bluish discoloration in early pregnancy, local cause for threatened abortion, local cause in APH), First trimester MTP by suction curettage . In second trimester MTP by Ethacredyl Lactate. Os thightening or cervical encircalage ,Removal of os thightening stitch at the onset of labor or at 38 wks. Inspection for suspected rupture of membranes.After forceps delivery to trace for cervical tears.

tony 2010 mbbs 4

Page 5: Instrumentsog 141019193014-conversion-gate02 3

Cuscos bivlaved self retaining speculum

• Retract anterior & posterior walls of cervix

• Disdv• Obscures vaginal walls so lesion may

be missed

• Insert /remove IUD

tony 2010 mbbs 5

Page 6: Instrumentsog 141019193014-conversion-gate02 3

Retractor

tony 2010 mbbs 6

Page 7: Instrumentsog 141019193014-conversion-gate02 3

Doyens’ retractor

• Nontraumatic blunt

• Depress bladder in CS

tony 2010 mbbs 7

Page 8: Instrumentsog 141019193014-conversion-gate02 3

Doyens retractor

• This instrument is used for retracting bladder during abdominal operations like LSCS , abdominal hysterectomy , laparotomy.

• The smooth edge and the curvature retracts the bladder and protects it during surgery

tony 2010 mbbs 8

Page 9: Instrumentsog 141019193014-conversion-gate02 3

Kellys retractor

tony 2010 mbbs 9

Page 10: Instrumentsog 141019193014-conversion-gate02 3

Abdominal wall retractor self retaining

tony 2010 mbbs 10

Page 11: Instrumentsog 141019193014-conversion-gate02 3

Forceps

tony 2010 mbbs 11

Page 12: Instrumentsog 141019193014-conversion-gate02 3

Artery forceps

tony 2010 mbbs 12

Page 13: Instrumentsog 141019193014-conversion-gate02 3

Artery forceps

• This is a hemostat. Used for clamping bleeding vessels. It is also used for grasping tissue at the time of operation. ( Opening and closing peritoneum) . It is also used to hold stay sutures. It comes in two shapes straight and curved.

• Usually straight is used for rough work like stay and curved is used as hemostat.

tony 2010 mbbs 13

Page 14: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 14

Page 15: Instrumentsog 141019193014-conversion-gate02 3

Mosquito Small artery forceps

tony 2010 mbbs 15

Page 16: Instrumentsog 141019193014-conversion-gate02 3

Needle Holder

• This instrument is used for grasping needle at the time of suturing. The inner surface of tip has criss cross serrations and a small grove for firm grasp of the curved needle.

• The box joint is placed very close to tip to give adequate pressure because of the lever effect.

tony 2010 mbbs 16

Page 17: Instrumentsog 141019193014-conversion-gate02 3

Volsellum forceps

• To hold • anterior lip of Cx• posterior lip of Cx• Cervical stump in subtotal hysterectomy

Its a long instrument with gentle curve so that the line of vision is not obstructed. The tip of the blades have 3-4 teeth

tony 2010 mbbs 17

Page 18: Instrumentsog 141019193014-conversion-gate02 3

• Insertion of IUCD , Cx Biopsy D&C, First trimester MTP with Suction Evacuation. Cx Biopsy , Fothergills operation, Vaginal Hysterectomy Posterior lip of the cervix is grasped for post. colpotomy .

• Since the teeth are sharp it is not used in pregnancy as it may cause cervical tares and lacerations. Instead sponge holding forceps is used to grasp the cervix

tony 2010 mbbs 18

Page 19: Instrumentsog 141019193014-conversion-gate02 3

Allis tissue forceps

• Interlocking teeth catch and lock

• To hold • peritoneum rectus sheath• Anterior lip of Cx• Traumatic arrest hge

Sterilization: By Autoclaving

This instrument is used for grasping tough structures like Rectus sheath or fascia in operations like tubectomy,LSCS,abdominal hysterectomy.

tony 2010 mbbs 19

Page 20: Instrumentsog 141019193014-conversion-gate02 3

Tenaculum forceps

• Long with single tooth at tip

• Catch present

• Major gynaec procedures like abdominal hysterectomy• Catch hold of vault/cervix

• Traumatic hold fim structures like cervix

tony 2010 mbbs 20

Page 21: Instrumentsog 141019193014-conversion-gate02 3

Babcock's Forceps

The tip is atraumatic as there are no sharp tooth

This instrument is used for grasping tubular structures like fallopian tube in tubectomy in modified Pomeroy's operation ,

ureter ,appendix etc.

tony 2010 mbbs 21

Page 22: Instrumentsog 141019193014-conversion-gate02 3

Sponge holding forceps

• Hold the pregnant uterus (less traumatic than volsellum forceps )• In traumatic PPH

• (walking around cervix)

• atleast 3 sponge ( one at 12 0 clock position & other to look for trauma) holding forceps to visualize Cx

• Cleaning & draping in surgical procedures

tony 2010 mbbs 22

Page 23: Instrumentsog 141019193014-conversion-gate02 3

Green ArmytageForceps

This forceps is used as a hemostat in caesarean operation. As the tips are broad wide area can be

compressed.

In LSCS the cut uterine edges bleed . This forceps is applied to the two angles and lower and upper edge of

the incision.

The common indications for LSCS are fetaldistress in first stage, CPD , abnormal presentations like

transverse lie , brow , breech in primi,previous two scars on the uterus.

tony 2010 mbbs 23

Page 24: Instrumentsog 141019193014-conversion-gate02 3

Kocher's Forceps ( Clamp)

The tips of the blades have teeth so that the tissue does not slip

This instrument is used for holding pedicles in hysterectomy.

The blades can either be straight or curved. This instrument is used in hysterectomy to clamp pedicles which are then transfixed

It is also used for salpingectomy in ectopic or oophorectomy in ovarian mass. This can also be used for clamping umbilical cordnewborn at the time of delivery or for artificial low rupture of membranes ( ARM).

tony 2010 mbbs 24

Page 25: Instrumentsog 141019193014-conversion-gate02 3

Ovum Holding Forceps

removing the products of conception in inevitable , incomplete abortion and in MTP operations.No catch

The tip of this instrument is rounded cup like to avoid perforation and to hold large tissue. This instrument has no catch . This is toavoid perforation of wall.

tony 2010 mbbs 25

Page 26: Instrumentsog 141019193014-conversion-gate02 3

Dissecting forceps non toothed

tony 2010 mbbs 26

Page 27: Instrumentsog 141019193014-conversion-gate02 3

myoma screw

• To hold the fundus of uterus in myomectomy & hysterectomy

tony 2010 mbbs 27

Page 28: Instrumentsog 141019193014-conversion-gate02 3

Towel clip

• Hold towels

tony 2010 mbbs 28

Page 29: Instrumentsog 141019193014-conversion-gate02 3

Leech Wilkinson cannula

• Hydrotubation for tubal patency

• It is straight instrument with conical tip. This cone is screwed into the cervix. Then dye is injected

tony 2010 mbbs 29

Page 30: Instrumentsog 141019193014-conversion-gate02 3

Scissors

tony 2010 mbbs 30

Page 31: Instrumentsog 141019193014-conversion-gate02 3

Mayo scissors

Straight mayo scissors

Curved mayo scissors

tony 2010 mbbs 31

Page 32: Instrumentsog 141019193014-conversion-gate02 3

Episiotomy Scissors.

tony 2010 mbbs 32

Page 33: Instrumentsog 141019193014-conversion-gate02 3

catheter

tony 2010 mbbs 33

Page 34: Instrumentsog 141019193014-conversion-gate02 3

Malecots catheter

tony 2010 mbbs 34

Page 35: Instrumentsog 141019193014-conversion-gate02 3

Foleys catheter

• Continous bladder drainage after surgery • Abdominal , Vaginal Hysterectomy ,

Wertheim's Hysterectomy, Repair of Vesico vaginal fistula.

• Atonic bladder • EASI• second trimester MTP for extra

amniotic instillation of ethacredyllactate .

• sono salpingo graphy

tony 2010 mbbs 35

Page 36: Instrumentsog 141019193014-conversion-gate02 3

Metal catheter

• Intermittent drainage as in vaginal hysterectomy

tony 2010 mbbs 36

Page 37: Instrumentsog 141019193014-conversion-gate02 3

D&C

tony 2010 mbbs 37

Page 38: Instrumentsog 141019193014-conversion-gate02 3

Uterine sound Its a long instrument with blunt tip ( To avoid perforation) About 5 cms from the tip its bend to make angle of 30 degrees.

It has marking on it for measurements. ( Bladder sound has no markings )

The angle helps to negotiate curvature of the uterus (Anteflexion). It is used for measuring uterocervical length , length of thcervix (for diagnosing supra vaginal elongation of the cervix). To feel for any pathology inside the cavity like fibroid ( Sub mpolyp) Congenital anomalies like septa or bicornuate ut.Adhesions or synachae. To feel for the misplaced IUCD.

It can create false passage or perforation especially in soft uterus in pregnancy.

tony 2010 mbbs 38

Page 39: Instrumentsog 141019193014-conversion-gate02 3

Uterine Curette Blunt endobstetric

Sharp gynaec

Use for scraping endometrial cavity to obtain sample for histopathology.

Diagnostic D&C is done commonly for Menorrhagia, Endometrial Carcinoma, Infertility ,Tuberculosis of endometrium .

It also has secondary beneficial advantage of reducing the bleeding in menorrhagia.

tony 2010 mbbs 39

Page 40: Instrumentsog 141019193014-conversion-gate02 3

Hegar's Dilator Dilate cervix

long rod like instrument with gentle curve and tapering tip.

It is used for dilatation of the cervix in procedures like

D&C , D& E , Fothergills operation , Hysteroscopy , Cervical Stenosis , Primary dysmenorrhoea.

The dilators are numberd as per outer diameter ( No 8 means outer diameter of 8 mm) For D&C dilation up to 8 is

Done For MTP dilatation up to 12 may be required. Very large dilatation can cause cervical incompetence perforation

tony 2010 mbbs 40

Page 41: Instrumentsog 141019193014-conversion-gate02 3

Mathew duncansdilator

tony 2010 mbbs 41

Page 42: Instrumentsog 141019193014-conversion-gate02 3

Papsmear

tony 2010 mbbs 42

Page 43: Instrumentsog 141019193014-conversion-gate02 3

Cevix sampling devices

tony 2010 mbbs 43

Page 44: Instrumentsog 141019193014-conversion-gate02 3

Ayre's Spatula

• Made of wood so that cells can adhere to its porous surface.

• Use for taking Pap Smear for screening of carcinoma cervix.• The long end is inserted into cervical canal and rotated in 360 degrees.

• The exfoliated cells obtained are smeared on glass slide and fixed in Koplicksjar which contains ether and alcohol in equal amount. or by hair spray.

• The other broad end is used for obtaining cells from lateral vagina for knowing the hormonal status & buccal smear

tony 2010 mbbs 44

Page 45: Instrumentsog 141019193014-conversion-gate02 3

Cervical brush

Pap smear

tony 2010 mbbs 45

Page 46: Instrumentsog 141019193014-conversion-gate02 3

Family planning

tony 2010 mbbs 46

Page 47: Instrumentsog 141019193014-conversion-gate02 3

Copper t

• 380 A (380SA of copper)}commonly used

tony 2010 mbbs 47

Page 48: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 48

Page 49: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 49

Page 50: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 50

Page 51: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 51

Page 52: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 52

Page 53: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 53

Page 54: Instrumentsog 141019193014-conversion-gate02 3

Female condom

tony 2010 mbbs 54

Page 55: Instrumentsog 141019193014-conversion-gate02 3

Male condom

tony 2010 mbbs 55

Page 56: Instrumentsog 141019193014-conversion-gate02 3

Balloon tamponade with condoms for PPH

tony 2010 mbbs 56

Page 57: Instrumentsog 141019193014-conversion-gate02 3

Karman cannula-plastic

It is of different sizes and the approximate size required for aparticular case equals to the weeks of pregnancy to be terminated

The plastic cannula has got advantages over a metallic one-as it causes less damage to the uterine wall and the productssucked out can be visible. The vacuum must be broken beforewithdrawal

tony 2010 mbbs 57

Page 58: Instrumentsog 141019193014-conversion-gate02 3

Karman cannula -Metallic

Suction evacuation MTPTo remove products of conceptionMissed abortion

tony 2010 mbbs 58

Page 59: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 59

Page 60: Instrumentsog 141019193014-conversion-gate02 3

Karman's Syringe ( Menstrual Regulation)

Menstrual Regulation and endometrial aspiration. The capacity is 50 ml. The tip has a rubber attachment with valve.

tony 2010 mbbs 60

Page 61: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 61

Page 62: Instrumentsog 141019193014-conversion-gate02 3

Laparoscopy

tony 2010 mbbs 62

Page 63: Instrumentsog 141019193014-conversion-gate02 3

Trocar and cannula

Used for Laparoscopy

Trocar is put in to the cannula and then inserted into abdominal cavity for laparoscopy. It is also called port ( port of entry to telescope and other instruments.) It is numbered as per outer diameter. 10 mm is used for operative telescope, 7 mm is used for Band Applicator for Tubal Ligation, 5mm is used for other hand instruments like grasper etc. A Reducer sleeve is available to use large size port for small instrument. It has a trumpet valve to prevent gas leak. On one side there is opening for connecting it to gas ( CO2 or Air)

tony 2010 mbbs 63

Page 64: Instrumentsog 141019193014-conversion-gate02 3

Varies Needle

• putting Air or CO2 in the peritoneal cavity) for laparoscopy..

tony 2010 mbbs 64

Page 65: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 65

Page 66: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 66

Page 67: Instrumentsog 141019193014-conversion-gate02 3

Operative vaginal delivery

tony 2010 mbbs 67

Page 68: Instrumentsog 141019193014-conversion-gate02 3

Vaccum Extractor(Ventouse).

tony 2010 mbbs 68

Page 69: Instrumentsog 141019193014-conversion-gate02 3

Cup for vacuum extraction

tony 2010 mbbs 69

Page 70: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 70

Page 71: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 71

Page 72: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 72

Page 73: Instrumentsog 141019193014-conversion-gate02 3

Wrigley's outlet Forceps

tony 2010 mbbs 73

Page 74: Instrumentsog 141019193014-conversion-gate02 3

• Obstetric forceps for out let forceps delivery. It has pelvic curve. Parts of the forceps are blades ( which has windows or fenestrate

• for firm grip of the head) ,Shank , Lock( English lock for Wriglys forceps) , Handle.

• Simson's Short forceps is straight forceps with only cephalic curve and no pelvic curve.

• Some of the Pre requisite for forceps application : Dilatation of the cervix must be full (10cm) Station of Vertex at plus 2 or plus 3 (for outlet forceps),membranes should be ruptured , pelvis must be adequate. Uterine contractions must be good. Rotation of vertex near complete. Local anesthesia and episiotomy must be given.

tony 2010 mbbs 74

Page 75: Instrumentsog 141019193014-conversion-gate02 3

tony 2010 mbbs 75

Page 76: Instrumentsog 141019193014-conversion-gate02 3

others

tony 2010 mbbs 76

Page 77: Instrumentsog 141019193014-conversion-gate02 3

Pinard's FetalStethoscope. auscultation of fetal heart.

tony 2010 mbbs 77

Page 78: Instrumentsog 141019193014-conversion-gate02 3

Umbilical cord clamp

tony 2010 mbbs 78