Top Banner
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512 Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 1 of 7 Tri-Tech Medical Inc. Medical Gas Master Panel Alarms - Wireless Installation Instructions for Med Touch Master Alarms - Wireless Master Alarm Panel Local Sending Master Alarm Panel - Receiving Master Alarm Panel - Repeater
7

Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

Jun 24, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 1 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

Installation Instructions for Med Touch Master Alarms - Wireless

Master Alarm Panel – Local Sending

Master Alarm Panel - Receiving

Master Alarm Panel - Repeater

Page 2: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 2 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

Install the hinge brackets onto

the lower flange of the box,

tighten with mounting screws.

After removing the flange nut,

slide the Antenna through the

designated hole at the top of

the back box, and slide the

bracket over the mounting

flange stud.

Once all of the connections are made,

turn the switch to “ON” from the Power

Supply. Close the Alarm Front and

tighten the center screw for a completed

finish.

Once the Antenna is through

the designated hole and the

bracket is adjusted, reinstall

the nut and tighten into

position

Power Supply Harness

Attach the Alarm Front to the hinge brackets, and

insert the lanyard mounting screws though the

lanyards and tightening onto the box studs.

(Lanyard Mounting Screws shipped w/ the Back Box)

Attach the Ground Wire to the Alarm Front Panel, and also

attach the Top Antenna Cable to the outside mating connector.

Once your connections are made, attach the Power Supply

Harness Plug as shown above. (See Figure 2 on Sheet 3)

Common Master Alarm Back Box Assembly Assembling the Master Alarms Bock Box: After installing the Back Box in the wall (The antenna can be mounted out the top or bottom of the Back Box)

1 2 3 4

Connection for Master Local Source Sending Panel Wireless Alarm

5

6

7

Remove the mounting flange nut

from the Top Left hand corner.

Flange Nut

Top Antenna Ribbon

Cable connection

Power Supply

Connection Attach Ground

Wire

Flange Nut

Hinge

Bracket

Lanyards

Mounting

Screws

Top Antenna

Ribbon

Power Supply

Harness

Page 3: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 3 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

Figure 2 – Master Local Source Sending Panel Wireless Alarm

Power Ribbon Cable

Power Button Board

Master Boards

Sending Board

Outside Connector

for Antenna Master Ribbon

Power Cable

Top Antenna

Ribbon Cable

Network Position “A”

Jumper Connector

Network Position “B”

Jumper Connector

Page 4: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 4 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

Once all of the connections are made,

turn the switch to “ON” from the Power

Supply. Close the Alarm Front and

tighten the center screw for a completed

finish.

Attach the Ground Wire to the Alarm Front Panel, and also

attach the Top Antenna Cable to the mating connector. Once

your connections are made, attach the Power Supply Plug and

the Receiving Power Plug connectors, both connectors are on

the same Harness as shown above. (See Figure 3 on Sheet 5)

Attach the Alarm Front to the hinge brackets, and

inserting the lanyard mounting screws though the

lanyards and tightening onto the box studs.

(Lanyard Mounting Screw shipped w/ the Back Box)

Connection for Master Receiving Panel Wireless Alarm

8 9

10

Power Supply

connection

Attach Ground

Wire

Lanyards

Mounting

Screws Antenna Ribbon

Antenna Ribbon

Cable connection Receiving

Power

Connection

Receiver Ribbon

Cable Assembly

Page 5: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 5 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

Figure 3 – Master Receiving Panel Wireless Alarm

Power Supply and

Receiving Power Supply Harness

Module

Ribbon

Cable

Button Power Board

Receiving

Ribbon

Cable

Receiving

Board

Master

Receiving

Board

Antenna

Ribbon

Cable

Ground

Attachment

Point

Page 6: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 6 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

Once all of the connections are

made, turn the switch to “ON” from

the Power Supply. Close the Alarm

Front and tighten the center screw

for a completed finish.

Attach the Alarm Front to the hinge brackets, and inserting the

lanyard mounting screws though the lanyards and tightening

onto the box studs.

(Lanyard Mounting Screws are shipped w/ the Back Box)

Attach the Ground Wire to the Alarm Front Panel, and also

attach the Top Antenna Cable to the mating connector. Once

your connections are made, attach the Power Supply Plug

connector as shown above.

Components for the Repeater

Alarm

Connection for Master Repeater Panel Wireless Alarm

11 12 13

Figure 4

Antenna

Assembly

Back Box

Hinge

Brackets

Mounting Hardware

Power Supply

Harness

Antenna Ribbon

Lanyards

Lanyard Mounting

Screws

Master Repeater

Alarm Front

Master Repeater Alarm Front

Antenna Ribbon

Antenna Assembly

Button Board

Power Harness Connection

Page 7: Installation Instructions for Med Touch Master Alarms ... · Med Touch Master Alarms - Wireless Master Alarm Master Panel –Local Sending Alarm Panel-Receiving Master Alarm Panel

e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512

Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 7 of 7

Tri-Tech

Medical Inc.

Medical Gas Master

Panel Alarms - Wireless

This page is left Intentionally Blank

Tri-Tech

Medical Inc.