Installing Flexi Cabinet for Outdoor DN7062824 Issue 2 en # Nokia Corporation 1 (107) 471449A 101 Nokia Flexi WCDMA Base Station, Rel. Flexi WBTS3.2, Product Documentation
Nov 08, 2014
Installing Flexi Cabinet forOutdoor
DN7062824Issue 2 en
# Nokia Corporation 1 (107)
471449A 101Nokia Flexi WCDMA Base Station, Rel. FlexiWBTS3.2, Product Documentation
The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This document is intended for the useof Nokia's customers only for the purposes of the agreement under which the document issubmitted, and no part of it may be reproduced or transmitted in any form or means without theprior written permission of Nokia. The document has been prepared to be used by professionaland properly trained personnel, and the customer assumes full responsibility when using it.Nokia welcomes customer comments as part of the process of continuous development andimprovement of the documentation.
The information or statements given in this document concerning the suitability, capacity, orperformance of the mentioned hardware or software products cannot be considered binding butshall be defined in the agreement made between Nokia and the customer. However, Nokia hasmade all reasonable efforts to ensure that the instructions contained in the document areadequate and free of material errors and omissions. Nokia will, if necessary, explain issueswhich may not be covered by the document.
Nokia's liability for any errors in the document is limited to the documentary correction of errors.NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENTOR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARYLOSSES), that might arise from the use of this document or the information in it.
This document and the product it describes are considered protected by copyright according tothe applicable laws.
NOKIA logo is a registered trademark of Nokia Corporation.
Other product names mentioned in this document may be trademarks of their respectivecompanies, and they are mentioned for identification purposes only.
Copyright © Nokia Corporation 2006. All rights reserved.
2 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Contents
Contents 3
1 Overview of installing FCOA 5
2 Removing the FCOA cabinet roof 7
3 Lifting the FCOA 9
4 Installing the cabinet 134.1 Anchoring the FCOA 134.2 Changing the opening direction of the FCOA door 174.3 Installing the FCOA security lock 31
5 Routing cabinet external cabling of FCOA 375.1 Routing the cables through FCOA cabinet bottom 375.2 Routing the cables through FCOA cabinet roof 39
6 Grounding the FCOA 43
7 Installing modules inside an outdoor cabinet 47
8 Installing options 538.1 Installing Flexi Power Module (FPMA) inside an outdoor cabinet 538.2 Installing air filter 548.3 Installing Flexi System External Alarm (FSEA) 628.4 Installing battery backup solutions 668.4.1 Disassembling the rack 668.4.2 Installing batteries 688.4.3 Installing PDU and site support module 768.4.4 Installing the rectifier units (WPMB/WPMC) 948.4.5 Changing the alarm polarity of the WPUB unit 968.4.6 Changing the alarm polarity of the WPUC unit 1008.5 Installing fire detector 102
9 Installation tools and torque values 1059.1 FCOA installation tools and equipment 1059.2 Torque values 106
10 Checklist for installing FCOA 107
DN7062824Issue 2 en
# Nokia Corporation 3 (107)
Contents
4 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
1 Overview of installing FCOAPurpose
This section describes the overview of the Nokia Flexi Cabinet for Outdoor(FCOA) installation process.
Steps
1. Check that the site meets the installation requirements.
For further information, see Requirements for Installation and Operation.
2. Locate the site pack in the bottom right corner of the cabinet.
3. Remove the cabinet roof.
4. If required, lift the cabinet to the installation location.
5. Anchor the cabinet on the base.
6. Change the door opening direction, if needed.
7. Install the security lock, if needed.
8. Prepare the cabinet cable entries.
9. Route the grounding cable and ground the cabinet.
10. Install the optional air filter (FCFA).
11. Install the Flexi System External Alarm (FSEA), if needed.
12. Install the Flexi System External OVP (FSEC), if needed.
13. Install the optional site support module (FCSA) and IBBU.
14. Install the optional fire detector (FCDA).
DN7062824Issue 2 en
# Nokia Corporation 5 (107)
Overview of installing FCOA
15. Install the modules inside the cabinet.
16. Route the cables in the cabinet and seal the cable entries.
17. Install the roof.
18. Connect the cables. For more information on cabling, see Cabling theBTS and Creating Configurations.
6 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
2 Removing the FCOA cabinet roofPurpose
The cabinet roof is removed for certain tasks, such as lifting the cabinet, routingthe cabinet external cabling through the roof, installing the air filter, changing thedoor handedness, or installing the Flexi System External Alarm or Flexi SystemExternal OVP.
DN7062824Issue 2 en
# Nokia Corporation 7 (107)
Removing the FCOA cabinet roof
Summary
Figure 1. Removing the cabinet roof
Steps
1. Open the door.
2. Remove the screws behind the front plate.
3. Remove the roof.
DN7068496
Back
3
2
1
8 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
3 Lifting the FCOAPurpose
Follow these instructions when the cabinet must be lifted to the desiredinstallation location.
An empty cabinet weighs max. 80 kg. It can be lifted by a sufficient number ofpersonnel using the lifting handles (WLHA lifting handle LEKA Kit 469554A).Lifting eye bolts are not included in the delivery. They can be ordered separately(LEKA Kit 466289A).
A fully equipped cabinet can be lifted with a crane.
DN7062824Issue 2 en
# Nokia Corporation 9 (107)
Lifting the FCOA
Figure 2. Lifting handles
Before you start
Check that the cabinet roof is removed.
Handle
DN70119951
10 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Summary
Figure 3. Lifting the cabinet
Warning
Follow the local safety regulations when lifting the cabinet.
Steps
1. Attach the 4 x M12 lifting eye bolts to the attachment points.
2. Attach the hoisting belt or rope to the lifting eye bolts.
DN7068215
Lifting eye bolts(4 places)
Minimum1500 mm(59.1 in)
1
2
3
DN7062824Issue 2 en
# Nokia Corporation 11 (107)
Lifting the FCOA
Make sure that the hoisting belt or rope loop is high enough to avoidbending the equipment.
Caution
A fully equipped cabinet weighs approximately 365 kg. Make sure that thehoisting belt or rope is sufficiently strong.
3. Lift the cabinet carefully to the desired installation height.
4. Mount the cabinet.
5. Remove the lifting equipment.
6. Install the roof.
12 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
4 Installing the cabinet
4.1 Anchoring the FCOA
Purpose
The cabinet must be anchored to the base if there is any risk of it toppling in areaswith an earthquake risk, for example.
Before you start
The site is prepared and ready.
When raining, some water may enter the cabinet through the door and back wall.It is important that the water can exit via the holes on the cabinet floor. If thecabinet is exposed to rain, it must be installed at least 20...50 mm off the groundby using, for example, an I-beam rail, metal grating or C-bars.
DN7062824Issue 2 en
# Nokia Corporation 13 (107)
Installing the cabinet
Figure 4. Anchoring the cabinet off the ground
DN70119909
Cabinet fixing nut
Cabinet spring washer
Anchor bolt
Steel structure
20-50mm
off
theground
14 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Summary
Figure 5. Anchoring the cabinet
Steps
1. Drill the anchoring bolt holes on the base.
See the drilling template in the packing.
DN7067649
Cabinet fixing nut
Cabinet spring washer
Anchor bolt
Concrete
DN7062824Issue 2 en
# Nokia Corporation 15 (107)
Installing the cabinet
Figure 6. Anchoring bolt locations
2. Attach the anchoring bolts to the base.
3. Position the cabinet on the anchoring bolts.
4. Fix the nuts on the anchoring bolts.
5. Check that the cabinet is level.
DN70119963
575mm
(22.6
in)
620 mm (24.4 in)
75 mm (3.0 in)
770mm
(30.3
in)
Front side
770mm (30.3 in)
fixing points
with air filter andcables routed viaside or bottom
450mm
(17.7
in)
1000mm
(39.3
in)
with air filter cablesrouted via back
16 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
6. Tighten the nuts to 49 Nm.
4.2 Changing the opening direction of the FCOA door
Purpose
The door opening direction can be changed.
Steps
1. Detach the wind stopper from the door.
2. Detach the wind stopper from the cabinet and the cabinet.
3. Detach the grounding cable from the door.
DN7073576
1
2
DN7062824Issue 2 en
# Nokia Corporation 17 (107)
Installing the cabinet
4. Remove the hinge pins and detach the door.
DN70119987
3
ground cable
Detail view inside the cabinet
18 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
5. Remove the hinge screws and hinges from the cabinet.
DN7073588
4
4
DN7062824Issue 2 en
# Nokia Corporation 19 (107)
Installing the cabinet
6. Remove the rubber plugs and install them on the other side of thecabinet.
DN7073591
5Remove
20 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
7. Move the hinges to the new location in the cabinet.
DN70148322
6
6
DN7062824Issue 2 en
# Nokia Corporation 21 (107)
Installing the cabinet
8. Detach the locking rod guide plate.
DN7073607
7 Screw
7
22 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
9. Detach the door side plate (lock side).
DN7073619
8
DN7062824Issue 2 en
# Nokia Corporation 23 (107)
Installing the cabinet
10. Invert the door side plate 180 degrees (upside down).
DN7073622
9
24 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
11. Attach the door side plate back in its place.
Fix with six screws. Tighten the two top screws first, then the two bottomones, and last the two screws in the middle.
DN7073658
10
DN7062824Issue 2 en
# Nokia Corporation 25 (107)
Installing the cabinet
12. Thread the guide plate to the locking rod and attach it to the door.
DN70145637
11a
11b
11b
11c
26 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
13. Invert the door 180 degrees (upside down).
DN70145676
12
DN7062824Issue 2 en
# Nokia Corporation 27 (107)
Installing the cabinet
14. Install the door to the cabinet using the hinge pins.
Push the hinge pins at least halfway down the hinge slots.
DN70145652
13
28 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
15. Thread the wind stopper to the guiding slot in the cabinet.
DN7073673
14
DN7062824Issue 2 en
# Nokia Corporation 29 (107)
Installing the cabinet
16. Attach the wind stopper to the door.
17. Detach the grounding cable from the cabinet.
DN70146893
15
DN7073685
16
30 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
18. Attach the grounding cable to the new location in the cabinet.
19. Attach the grounding cable to the door.
20. Move the magnetic proximity sensor magnet part from the bottom ofthe door to the top.
a. Detach the two M3 screws.
b. Invert the detached part 180 degrees.
c. Move the magnet part to its new location and fix with the two M3screws.
4.3 Installing the FCOA security lock
Purpose
An optional security lock can be installed on the cabinet door to preventunauthorised personnel from accessing the cabinet. The lock installation is eithera right-hand or left-hand installation depending on the handedness of the cabinetdoor.
DN70120014
18
groundcable
19
DN7062824Issue 2 en
# Nokia Corporation 31 (107)
Installing the cabinet
Summary
Figure 7. Installing the security lock
Steps
1. Remove one of the rubber plugs.
DN70148334
Right hand installation
Left hand installation
LockedUnlocked
LockedUnlocked
32 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
2. Remove the generic security lock latch from the lock.
3. Take the Flexi BTS specific security lock latch from the site pack.
4. Fit the security lock on the cabinet door.
1
DN70148346
DN70148358
3
DN7062824Issue 2 en
# Nokia Corporation 33 (107)
Installing the cabinet
5. Secure the security lock in its place with a nut.
6. Attach the Flexi BTS specific security lock latch to the lock.
DN70148373
4
DN70148397
5
34 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
7. Secure the lock latch with a nut.
8. Fix a rubber plug into the empty hole.
9. Test the security lock.
Test the lock by turning the key clockwise. Check that the latch movescorrectly and that the door can be locked.
In a left-hand installation, test the lock by turning the key clockwise andmake sure that the latch is pointing upwards.
DN70148416
6
DN7062824Issue 2 en
# Nokia Corporation 35 (107)
Installing the cabinet
36 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
5 Routing cabinet external cabling ofFCOA
5.1 Routing the cables through FCOA cabinet bottom
Purpose
The cabinet external cables can be routed in the cabinet through the cable entryon the cabinet bottom.
Caution
Optical cables are sensitive. When routing optical cables, do not exert stresson the optical fibres.
Summary
DN7062824Issue 2 en
# Nokia Corporation 37 (107)
Routing cabinet external cabling of FCOA
Figure 8. Routing the cables through cabinet bottom
DN7067785
1
2
powercables
3
transmissioncables
cableties
cable routingsupports
5
4
6
antennacables
cableties
7
38 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Steps
1. Detach the two screws on the right.
2. Remove the two cable gaskets from the cable entry.
3. Connect the grounding cable.
4. Route the power cables using cable clamps.
Cable clamps and screws are included in the site pack.
5. Route the transmission cables through the cable entry and fix withcable ties.
6. Install one of the cable gaskets, fixing cables to their places.
7. Route antenna cables through the cable entry. Fix the cables withcable ties.
8. Install the remaining cable gasket, fixing cables to their places.
5.2 Routing the cables through FCOA cabinet roof
Purpose
The cabinet external cables can be routed in the cabinet through the cabinet roof.
Before you start
Remove the cabinet roof.
DN7062824Issue 2 en
# Nokia Corporation 39 (107)
Routing cabinet external cabling of FCOA
Summary
Figure 9. Routing the cables through cabinet roof
1
DN7068099
Cableentries
1
2
2
4
5
cableclambs
cableties
3 6
6power cables
40 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 10. Cable tie locations
Steps
1. Remove the cover plate from the lead-through you are going to use.
There are three possible lead-throughs on top of the cabinet: one on eachside, and one in the back.
If you are using the lead-through in the back of the cabinet, first remove therubber lead-ins on the inside of the cabinet to uncover the cable entryscrews.
2. Place the lower half of the cable entry on the lead-through and fix withscrews.
DN70100888
DN7062824Issue 2 en
# Nokia Corporation 41 (107)
Routing cabinet external cabling of FCOA
3. Route the cables in the cabinet.
Power cables must be routed through cable clamps to reduce strain on thecables. Cable clamps and screws are included in the site pack.
4. Fix the power cables with cable clamps.
5. Fix the other cables with cable ties.
6. Place the upper half of the cable entry on top of the lower one, fixingthe cables to their places. Fix with screws.
42 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
6 Grounding the FCOABefore you start
The grounding cable is not included in the delivery. It must be min. 16 mm2
(AWG 4).
DN7062824Issue 2 en
# Nokia Corporation 43 (107)
Grounding the FCOA
Summary
Figure 11. Grounding points in FCOA
Steps
1. Make sure the grounding cable is fixed to the site grounding point.
2. Guide the cable through the cable entry.
3. Strip approx. 2 cm (0.79 in.) of the main ground cable.
4. Insert the stripped end of the cable into a cable shoe lug and crimp.
DN70100864
44 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
5. Fit the lug to the grounding point in the cabinet and fix with a starwasher and nut.
Tighten to 3 Nm (for M5) or 5 Nm (for M8).
Tip
M8 is recommended for main grounding.
Further information
The modules are grounded to the cabinet rack, and no separate module groundingcables are required.
DN7062824Issue 2 en
# Nokia Corporation 45 (107)
Grounding the FCOA
46 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
7 Installing modules inside an outdoorcabinet
Purpose
This section describes the module installation process inside an outdoor cabinet.The recommended installation location for the Flexi WCDMA BTS modules isthe bottom of the cabinet. However, if you are going to use the site supportmodule, reserve the bottom half of the cabinet for that purpose and install themodules starting from the top of the cabinet.
Before you start
. If you are going to install cabinet options, such as the site support module,it is recommended that you do it before the module installation.
. Take the site pack from the bottom right corner of the cabinet.
Note
There are two air guide plates in the site pack. In Epsilon, when ESMA is inthe vertical racks, the plate is fixed next to the ESMA (right-hand side) toguide air circulation and to provide a fixing point for cables.
Warning
When handling the modules, always use the antistatic wrist strap. Thecabinet must be grounded, otherwise the antistatic wrist strap will notwork.
DN7062824Issue 2 en
# Nokia Corporation 47 (107)
Installing modules inside an outdoor cabinet
Note
Module cable entries are not used in cabinet installations.
Tip
Install the transmission sub-module to the System Module and connect the DCpower cable before installing the System Module in the cabinet.
48 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Summary
Figure 12. Installing modules inside an outdoor cabinet
Steps
1. Remove the fixing studs from the module casings.
2. Remove the support plate behind the cage nuts.
3. Remove the cable support plates from the casings.
DN7067688
1
4 4
3
3
67
8
5
DN7062824Issue 2 en
# Nokia Corporation 49 (107)
Installing modules inside an outdoor cabinet
4. Detach the cage nuts from the module.
5. Fix the guide plates (from the site pack).
The cabinet has U markings printed on the fixing rail for 2 U and 3 U units.Check the markings and the sticker on the right-hand side to determine thestarting place for module installation. There are 1 U markings on both sidesof the racks.
1 U is 44.45 mm.
Figure 13. Placing shelves for WCDMA modules
DN7067734
6U
9U
12U
15U
18U
21U
24U
27U
1U
3U
6U
3U
29U
1U
5U
50 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Tip
Use the dummy panels to determine the cage nut locations.
Tip
Fit the cage nuts so that the nut brackets point upwards and downwardsinstead of left and right.
6. Fix the cage nuts (from the module) inside the cabinet.
7. Slide the first module in.
8. Fix the module to the cabinet with screws.
Tighten to 5 Nm.
9. Repeat for each subsequent module.
10. Install dummy panels into the empty slots.
DN7062824Issue 2 en
# Nokia Corporation 51 (107)
Installing modules inside an outdoor cabinet
Expected outcome
Figure 14. Installation example, modules inside the cabinet
DN7067691
Installation example, starting from the bottom Site support installation
52 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
8 Installing options
8.1 Installing Flexi Power Module (FPMA) inside anoutdoor cabinet
Purpose
The Flexi WCDMA BTS uses 48 V DC power. In a BTS site with AC feed only,a Flexi Power Module (FPMA) or a site support module is required forconverting the AC to DC before feeding the DC power to the System Module.
The Flexi Power Module (FPMA) consists of mechanics, AC terminal and fourslots for AC/DC sub-module (FPAA) or battery sub-module (FPBA).
The FPMA can include:
. two FPAAs and two FPBAs
. four FPAAs
. one FPAA and three FPBAs
. one FPAA and three free slots for expansion.
Steps
1. Remove the fixing studs for the module casing.
2. Remove the support plate behind the cage nuts.
3. Detach the cage nuts from the module.
4. Remove the dummy panels.
5. Fix the cage nuts (from the module) on the rack on the left-hand side ofthe cabinet.
DN7062824Issue 2 en
# Nokia Corporation 53 (107)
Installing options
6. Insert the module.
7. Fix with screws.
8. Insert dummy panels into the empty slots.
Further information
For FPAA and FPBA installation instructions, see section Installing Flexi PowerModule (FPMA) in the Installing the Modules document. The sub-modules canbe installed inside the FPMA before installing it into the cabinet.
8.2 Installing air filter
Purpose
The optional air filter can be used in case the environment is extremely dirty.
Before you start
Remove the cabinet roof.
Tip
It is recommended that the cabling be routed to the side or bottom when the airfilter is used. If the cables are routed in the rear, antenna jumper cables mustbe disconnected.
Summary
54 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 15. Air filter power supply cable (left-hand installation)
Steps
1. Remove the 4 x M5 screws inside the cabinet.
DN70121119
to control box
ambient pressurehose
cabinet pressurehose to + terminal
pressure sensor
DN7062824Issue 2 en
# Nokia Corporation 55 (107)
Installing options
2. Remove the cabinet back plate.
Lift the back plate first upwards and then outwards.
3. Remove the two bars behind the cabinet.
Loosen the 4 x M5 screws from both sides and detach the bars.
M54 pcs
back side
1
2
DN70150241
56 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
4. Remove the air filter roof.
3
DN70150253
DN7062824Issue 2 en
# Nokia Corporation 57 (107)
Installing options
5. Fix the air filter in place with the guide pins (one at the top and one atthe bottom of the air filter).
DN70150265
4
58 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
6. Fix the air filter on the cabinet with 22 x M5 screws at the back and 4 xM5 on the roof.
Tip
Use the screws from the detached bars in the previous step. In addition, useadditional screws included in the air filter site pack.
7. Connect the alarm cable to the FSEA box.
8. Route the air filter fan power cable through a vacant bushing seal andconnect it to the screw terminal on the control box printed circuitboard.
There are two alternatives. Either:
a. Connect the power cable (995083) from the FPFA.
Or:
DN70150277
7M5
15 pcs
5
6
DN7062824Issue 2 en
# Nokia Corporation 59 (107)
Installing options
b. Attach the fuse into the FSEA box DIN rail and connect the powercable (995084).
9. Connect the air filter power cables to the FSEA box.
Make sure that the polarity is correct: black +, blue -.
10. Route the ambient pressure hose to the cabinet door.
11. Install the back cover.
DN70121119
DN70150289
60 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
12. Install the air filter roof.
13. Install the cable entry, if necessary.
14. Install the cabinet roof.
15. Install the wind blocking plate on the cabinet door, if necessary.
DN70150432
12
1315
DN7062824Issue 2 en
# Nokia Corporation 61 (107)
Installing options
a. Fix four screws and washers on the cabinet door.
b. Install the wind blocking plate.
c. Tighten the screws.
d. Fix the rubber plugs in the wind blocking plate.
8.3 Installing Flexi System External Alarm (FSEA)
Purpose
The Flexi System External Alarm (FSEA) is used as an external alarm module.The box provides IP55 protected screw terminals (12 for alarm inputs and 6 forcontrol outputs) and power for the Flexi Cabinet Fire Detector (FCDA).
DN70154764
16a
16b
16c
16d
62 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Before you start
The system external alarm connection box can be installed on a pole or wall.Locate the box in the proximity of the System Module. In wall installations, makesure that the mounting surface is flat.
The box can also be installed on the roof of an outdoor cabinet. In cabinetinstallations, use the fixing points on the cabinet roof.
Caution
Electrostatic discharge (ESD) may damage the equipment. Wear an ESD wriststrap when handling the external alarm connection box.
Note
Make sure that jumper X1103 is set to WCDMA.
Tip
When connecting the cables, make sure that the cable lead-ins that are notused are blocked.
Steps
1. Install the box with 4 x M5 screws using the fixing holes in the bottomof the box.
The box can be installed either horizontally (cable lead-ins on the side) orvertically (cable lead-ins facing downwards). In outdoor installations, thecable lead-ins must be facing downwards to meet the IP55 standard.
2. In wall or pole installations, fix the box and cables to the wall or pole.
3. Connect the grounding cable to the grounding screw on the right sideof the FSEA front plate.
Screw the nut tightly.
4. Connect the ESD wrist strap first to your wrist and then to thegrounding clip next to the grounding screw.
DN7062824Issue 2 en
# Nokia Corporation 63 (107)
Installing options
5. Connect the external alarms cable (included in the FSEA delivery)from the FSEA to the System Module.
a. Pull the left U-shaped cable gland from the FSEA box.
b. Remove the hole closing plug from the cable gland. If the plug isfixed with a cable tie, cut the cable tie first and remove it.
c. Insert the cable in the cable gland. The D-Sub plug must point to theinside of the box.
d. Connect the D-Sub plug to the leftmost D-Sub connector X1101 onthe FSEA board.
e. Fix the connector fixing screws.
f. Insert the U-shaped cable gland to the front plate.
g. Fix the cable with a cable tie. Make sure that the U-gland fixes thecable tightly.
h. Remove the cover of the EAC connector on the System Module.
i. Insert the other end of the cable with the MDR-36 connector to theEAC connector of the System Module. Make sure that the MDRconnector is firmly in place.
j. Push the connector cover over the MDR connector and seal the EACconnector at the System Module with this cover.
k. Route the cable between the FSEA and System Module and fix itwith cable ties. The first fixing point must not be further away fromthe FSEA box than 0.5 m.
6. Connect the combined alarm cable with a D-Sub connector.
Tip
When upgrading to the Flexi WCDMA BTS, there might be a pre-installedalarm cable with a 37-pole D-Sub connector attached. This cable can beattached to the EACX-I connector of the FSEA.
a. Pull the right U-shaped cable gland from the FSEA box.
b. Cut the cable tie off the cable gland.
c. Remove the hole closing plug from the cable gland.
d. Insert the alarm cable in the cable gland. The D-Sub plug must pointto the inside of the box.
e. Attach the D-Sub plug to the right 37-pole D-Sub connector X4101(EACX-I port).
f. Fix the connector fixing screws.
g. Insert the U-shape cable gland to the front plate.
64 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
h. Fix the cable with a cable tie. Make sure that the U-gland fixes thecable tightly.
i. Route the cable and fix it with cable ties. The first fixing point mustnot be further away from the FSEA box than 0.5 m.
7. Connect the single alarm cables to the screw terminals.
a. Insert the alarm cables in the FSEA box by using the cable glands onthe right-side half of the FSEA box.
b. Tighten the cable gland nut.
c. Route the alarm cables and fix them with cable ties. The first fixingpoint must not be further away from the FSEA box than 0.5 m.
d. Attach alarm lines EXT_AL0 to EXT_AL11 using screw terminalblocks X4106-X4109.
e. For each alarm input connect one wire to the GROUND screwterminal blocks X4107 or X4109 and connect one wire to theselected alarm input on screw terminal blocks X4106 or X4108. Thealarm inputs are marked on the FSEA board with "EXT_AL5 ...EXT_AL0" on X4106 and "EXT_AL11 ... EXT_AL6" on X4108.
Note
If you use alarm inputs on the EACX-I port (D-Sub connector X4101), do notuse the same alarm inputs on the screw terminals X4106 and X4108.
8. Connect the control output cables.
a. Insert the control output cables in the FSEA box by using the cableglands on the right-side half of the box.
b. Tighten the cable gland nut.
c. Route the control cables and fix them with cable ties. The first fixingpoint must not be further away from the FSEA box than 0.5 m.
d. Attach the control lines EXT_CO0 to EXT_CO5 by using the screwterminal blocks X4104 and X4105.
e. For each control output connect one wire to the +5V screw terminalblock X4105 and one wire to the selected control output on screwterminal X4104. The control outputs are marked on the FSEA boardwith "EXT_CO5 ... EXT_CO0" on X4104.
Note
If you use control outputs on the EACX-I port (D-Sub connector X4101), donot use the same control outputs on the screw terminal X4104.
DN7062824Issue 2 en
# Nokia Corporation 65 (107)
Installing options
9. Install the fire detector to the FSEA (optional).
a. Connect the fire detector to the FSEA using a four-wire cable. Twowires are needed for fire detector power supply and two for the firedetector alarm connection.
b. Attach the four wires of the cable to the fire detector relay-base.
c. Insert the other end of the four wire cable through one cable gland atthe right half of the FSEA box.
d. Tighten the cable gland nut.
e. Route the alarm cables and fix them with cable ties. The first fixingpoint must not be further away from the FSEA box than 0.5 m.
f. Attach the wire marked with + from the fire detector to the leftmostor rightmost opening of the screw terminal X4114.
g. Attach the wire marked with - from the fire detector to one of thefour middle openings of the screw terminal X4114 marked withGND.
h. Attach the fire detector alarm wires to one of the alarm inputs"EXT_AL11 ... EXT_AL0".
10. Close the cover of the FSEA box.
Tighten the six screws.
8.4 Installing battery backup solutions
8.4.1 Disassembling the rack
Purpose
Before installing the site support, the lower part of the cabinet rack must bedisassembled.
66 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Summary
Figure 16. Disassembling the rack
Steps
1. Remove the screws (8 pcs).
See figure Disassembling the rack for a detailed screw location.
Tip
Save the screws for later use.
2. Disassemble the two lower shelves and the vertical wall.
DN7067773
DN7062824Issue 2 en
# Nokia Corporation 67 (107)
Installing options
Further information
Proceed to the Installing batteries section.
8.4.2 Installing batteries
Before you start
. Install the PDU unit in the site support module.
. Disassemble the rack as instructed in the Disassembling the rack section.
. Make sure that the outdoor cabinet is grounded to the site main ground.
Summary
Figure 17. Principle of installing batteries
DN70148685
Battery backfixing plate
68 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Steps
1. Install the mounting part to the left.
2. Fix with two screws on the wall and two screws on the floor.
3. Remove the floor plate.
4. Install the air guide plate between the left mounting rack and thecabinet rack with two screws.
DN7073704
1
1
DN7073716
2
DN7062824Issue 2 en
# Nokia Corporation 69 (107)
Installing options
5. Install the battery back fixing plate.
There are two possible installation locations depending on the size of thebatteries.. If you are using 92 Ah batteries, proceed as instructed in these
instructions.. If you are using 62 Ah batteries, remove the rail from the battery
back fixing plate first.
6. Fix with three screws.
DN70121049
4
70 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 18. 92 Ah batteries
Figure 19. 62 Ah batteries
7. Move the battery support on the left to the location required by thesize of the batteries.
DN70119842
6
5
right sideleft side
Rail
6
DN7073728
right sideleft side
65
6
DN7062824Issue 2 en
# Nokia Corporation 71 (107)
Installing options
Figure 20. Locating the battery supports
DN7073731
battery supports
7
72 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 21. Principle of locating the battery supports
8. Install the mounting rail to the right. Fix with two screws.
See the following figure for a detailed location.
62 Ah
space forbatteries
DN70135374
rail
space forbatteries
92 Ah
DN7062824Issue 2 en
# Nokia Corporation 73 (107)
Installing options
9. Install the batteries.
Use an isolated wrench.
DN7073743
8
6 U
74 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
a. Fix 4 x cage nuts to the cabinet.
b. Place the batteries in the cabinet, starting from either left or right.
c. Fix with the battery front plate.
DN7068121
left side right side
cagenuts
9a
9a
9b
9d9f
9f9c
9e
andersoncable
9g
DN7062824Issue 2 en
# Nokia Corporation 75 (107)
Installing options
If you are using 62 Ah batteries, remove the rail behind the batteryfront plate.
d. Connect the batteries in series and tighten the bolt.
e. Install the battery terminal covers.
f. Connect the Anderson cable (994955) to the batteries and tighten to5 Nm.
Make sure you install the rubber boots.
g. Fix the battery cable connector to the battery front plate with cableties.
8.4.3 Installing PDU and site support module
Purpose
The optional site support module (FCSA) can be used with the outdoor cabinet toprovide long-term battery back-up time for the Flexi WCDMA BTS, and a spacefor installing LTE units. The PDU (Power Distribution Unit, WPUB or WPUC) isutilised when a site support module is used. The PDU converts the AC power intoDC power, which the base station uses.
The FCSA control card collects and converts alarms information from the fans,LTE units and MIBBU. The alarms are connected to EAC lines, which is donewith the use of dip switches on the board. The default settings are presented in thefollowing table. If necessary, the routing of alarms can be changed by adjustingthe dip switches.
Table 1. External alarms pin assignment
Pin Signal Pin Signal
1 INT_FAN_ALARM 9 MAINS#3
2 EXT_FAN_ALARM 10 ALARM_GND
3 TEMP_ALARM 11 ALARM_GND
4 LTE_POWER_ALARM
12 ALARM_GND
5 EXT_ALARM1(default notconnected)
13 ALARM_GND
6 EXT_ALARM2(default notconnected)
14 ALARM_GND
7 MAINS#1 15 ALARM_GND
8 MAINS#2
76 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 22. FCSA control card
DN70164318
StatusExt AlarmsOutput
MIBBU AlarmsInput
Intfan1
Intfan2
Status
Extfan2
Extfan1
+ -48 V Out
Fusemax 3.15 A
+ -48 V Out
Fusemax 3.15 A
+ -48 V Out
Fusemax 3.15 A
+ -48 V Out
Fusemax 3.15 A
Fusemax 10 A
+ -48 V Out
DN7062824Issue 2 en
# Nokia Corporation 77 (107)
Installing options
Before you start
. Open the site support module and take out the installation parts.
. Check that the alarm polarity is correct. The default setting for the alarmpolarity is Normally Open. If you need to change it, see Changing thealarm polarity for the WPUB unit or Changing the alarm polarity for theWPUC unit, depending on your base station setup. Remember also tochange the Intelligent Shutdown polarity, if using it.
Steps
1. Fix the external fans on the site support module (FCSA).
2. Remove covers from the bushing seals you are going to use.
3. Place the FCSA module on its back. Take care not to damage the guidepins on the module.
DN70154873
1
78 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
4. Remove the plastic cover from the rear of the PDU.
The plastic cover shields the connectors from above. It needs to beremoved before the cables can be attached to the PDU.
Caution
Risk of short circuit. Make sure that all the breakers on the power distributionunit (PDU) front panel are in the OFF position before you connect the cables.
5. Uninstall the FCSA control card.
6. Connect the cable (994953) behind the control card and reinstall thecontrol card.
DN70155245
4
5
DN7062824Issue 2 en
# Nokia Corporation 79 (107)
Installing options
7. Connect the control card power feeding cable to the PDU.
DN70155221
6b
6a
80 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
DN70155233
++
--
-BTS
-Batte
ry-
Common+
7
7
DN7062824Issue 2 en
# Nokia Corporation 81 (107)
Installing options
Figure 23. Principle of connecting the control card power feeding cable to PDU
In case the MIBBU is not used, power for the control card for FCSA istaken from the power terminals on the cabinet roof.
8. Route the battery cables through the cable entries in the back of thesite support module.
Make sure the rubber parts remain in place when routing the cables. Do nottighten the bushing seals at this point.
DN0550465
82 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
9. Attach the DC cables to the rear of the PDU.
DN70155257
8
++
--
-BTS
-Batte
ry-
Common+
8
DN7062824Issue 2 en
# Nokia Corporation 83 (107)
Installing options
DN70155269
9
++
--
-BTS
-Batte
ry-
Common+
9
10
84 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 24. Connecting DC cables to PDU (WPUB)
Figure 25. Connecting DC cables to PDU (WPUC)
10. Reinstall the plastic cover on the PDU.
Top view WPUB cabling
+ + -
Connectthe cables
Remove theplastic cover
--
DN7068106
Controlcard
-
BTS
-
Battery
+
BTS
+
Battery
-
Controlcard
+
BTS - Battery - Common+
1
Removetheplasticcover
Top view WPUC cabling
45 degreesor less
DN70120077
BTS - Battery - Common +
Controlcard
-
Battery
-
Controlcard
+
Battery
+
Remove theplastic cover
BTS
-
BTS
+
Connectthe cables
DN7062824Issue 2 en
# Nokia Corporation 85 (107)
Installing options
11. Route the AC cable through the cable entry in the rear of the FCSA.
12. Connect the AC cable to the AC terminal plate.
See the following figures for AC cable connections.
DN70155272
11
86 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 26. Single phase, 230 V AC
DN02165007
Cable routingsupport
AC Powerinput cable
Bridges
N1
N2
N3
L1
L2
L3
PE
L1/L2/L3= PhaseN= Neutral, PE= Protective earth
1~ Connection
N
PE
N1N2N3PE
LL1L2L3
Single Phase connection
DN7062824Issue 2 en
# Nokia Corporation 87 (107)
Installing options
Figure 27. 3-phase (delta), base voltage 100-120 V AC
DN02178657
Cable routingsupport
AC Powerinput cable
L1/L2/L3= PhaseN= Neutral, PE= Protective earth
PE
N1N2N3PE
L1L1L2L3
L2L3
3~ Connection
L1
L2
L3
N1
N2
N3
PE
3-phase delta connection
88 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Figure 28. 3-phase (star), 230 V AC
13. Install the AC terminal plate on the FCSA.
The AC interface comes attached to the PDU with a sleeve. Install the ACterminal plate inside the brackets in the site support module:
a. Slide the rear edge of the AC interface in the bracket slots.
b. Fix the front edge on the bracket with two screws.
DN02178645
Cable routingsupport
AC Powerinput cable
L1/L2/L3= PhaseN= Neutral, PE= Protective earth
3~Y Connection
N
PE
N1N2N3PE
L1L2L3
L1L2L3
L1
L2
L3
N1
N2
N3
BridgePE
3-phase star connection
DN7062824Issue 2 en
# Nokia Corporation 89 (107)
Installing options
14. If you are using the WPUB unit
Then
connect the thermal sensor cable to the back of the PDU.
15. Install the PDU.
Slide the PDU unit inside the site support module. Fix with four screws.
DN70155284
12
13
90 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
16. Tighten the bushing seals.. PG13.5 to 2.5 Nm. PG21 and PG29 to 5 Nm
17. If you are using the WPUC unit
Then
connect the battery thermal sensor cable to the front panel of the PDU.
18. Align the site support module (with the PDU unit) with the guidingpins in the back of the cabinet. Install the site support module.
DN70155518
16
15
DN7062824Issue 2 en
# Nokia Corporation 91 (107)
Installing options
19. Fix the site support module to the cabinet with two screws.
20. Route the thermal sensor cable and push the rubber plug in place.
DN70155296
18
DN70119878
19
92 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
21. Connect the site support fan cables to the Int fan and Ext fanconnectors on the FCSA control card.
Route the cables through the site support module cable entries. Push therubber plug through the cable entry to seal the entry point. Fix the fancables to the cabinet with cable ties.
22. Connect the alarm cable from the Ext Alarms Output connector on theFCSA control card to the external alarms connector located in theFSEA box (if used) on the cabinet roof.
Route the alarm cable through the cable entries on the side of the sitesupport module sloping downwards. Once the cable is outside the sitesupport module, make a loop and route the cable to the cabinet roof.
DN70121652
22
DN7062824Issue 2 en
# Nokia Corporation 93 (107)
Installing options
23. Connect the alarm cable from the EAC connector on the PDU to theMIBBU Alarms Input connector on the FCSA control card.
Fix with cable ties.
There are three alarm lines from the MIBBU unit routed via the controlcard to the FSEA. If additional alarms from the MIBBU are needed, aseparate cable between the MIBBU and FSEA is required.
24. Connect the battery cable connector from the PDU to the battery cableconnector from the batteries.
8.4.4 Installing the rectifier units (WPMB/WPMC)
Purpose
The PDU provides four slots for the rectifiers. Each of the PDU versions (WPUB/WPUC) has its own rectifier unit: WPMB/WPMC. Install the rectifier units asdescribed in these instructions.
Before you start
Remove the dummy panels from the PDU.
DN70100525
94 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Steps
1. Install the rectifier units.
Install the rectifier units in their places. Note that if the rectifier is the typethat has the retaining hooks (WPMB), the hooks must be in an openposition before fixing the unit in place. Use a small screwdriver in theholes in the upper left- and right-hand corners of the unit to release thehooks.
Figure 29. Installing the rectifiers, WPMB (top) and WPMC (bottom)
2. Secure the units.
Retaining hooks
Fixing screw
1
2
DN0424983
DN7062824Issue 2 en
# Nokia Corporation 95 (107)
Installing options
When the unit is in place, tighten the knurled-head fixing screw or insertthe retaining hooks in their slots, depending on the unit type used.
Note
The retaining hooks are fragile. Do not carry the unit by the retaining hooks.
3. Switch on the breakers on the PDU front panel.
Turn the breakers on the PDU front panel into the ON position.
Note
Do not switch on the breakers before the BTS installation is completed.
4. Close the lid.
8.4.5 Changing the alarm polarity of the WPUB unit
Before you start
The EAC alarm polarity can be set to two states, Normally Open or NormallyClosed.
The Normally Open state means that the galvanic EAC alarm circuit loop is openand electric current is not flowing through it. The corresponding EAC alarm isactivated if the EAC alarm circuit loop is closed.
The Normally Closed state means that the galvanic EAC alarm circuit loop isclosed and electric current is flowing through it. The corresponding EAC alarm isactivated if the EAC alarm circuit loop is opened.
The default alarm polarity is Normally Closed.
Note
Ensure that you set the EAC alarm polarity correspondingly during BTScommissioning.
96 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Steps
1. To change the polarity for alarm relay output from the Normally Openstate to the Normally Closed state, connect the wires according to thefollowing table and figure Changing the alarm polarity of the WPUBunit, option B.
Table 2. CON 5 Relays for the Normally Closed state
Pin no. Name Connect to
19 REL6 NC Not in use
20 REL6 NO D-sub female pin 6
21 REL6 COM Link to pin 36 on thisconnector
22 REL5 NC Not in use
23 REL5 NO D-sub male pin 5
24 REL5 COM Link to pin 36 on thisconnector
25 REL4 NC Not in use
26 REL4 NO D-sub male pin 4
27 REL4 COM Link to pin 36 on thisconnector
28 REL3 NC Not in use
29 REL3 NO D-sub male pin 3
30 REL3 COM Link to pin 36 on thisconnector
31 REL2 NC Not in use
32 REL2 NO D-sub male pin 2
33 REL2 COM Link to pin 36 on thisconnector
34 REL1 NC Not in use
35 REL1 NO D-sub male pin 1
36 REL1 COM Common + link to above
DN7062824Issue 2 en
# Nokia Corporation 97 (107)
Installing options
Note
If necessary, use a screwdriver to remove the CON5 connector from theWPUB before changing the polarity. Reinstall the CON5 connector after thepolarity has been changed.
Figure 30. Changing the alarm polarity of the WPUB unit
Rear view of interface card/system
B) Relays for Normally Open (default polarity)
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
21 22 23 24 25 26 27 28 29 30 31 32 33 34 3536
CON 4 CON 5
Pin 19 Pin 36
DN0570827
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20 19 20
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
21 22 23 24 25 26 27 28 29 30 31 32 33 34 3536
CON 4 CON 5
A) Relays for Normally Closed
Pin 19 Pin 36
98 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
2. To change the polarity for alarm relay output back from the NormallyClosed state to the Normally Open state, connect the wires accordingto the following table and figure Changing the alarm polarity of theWPUB unit, option A.
Table 3. CON 5 relays for the Normally Open state
Pin no. Name Connect to
19 REL6 NC D-sub male pin 6
20 REL6 NO Not in use
21 REL6 COM Link to pin 36 on thisconnector
22 REL5 NC D-sub male pin 5
23 REL5 NO Not in use
24 REL5 COM Link to pin 36 on thisconnector
25 REL4 NC D-sub male pin 4
26 REL4 NO Not in use
27 REL4 COM Link to pin 36 on thisconnector
28 REL3 NC D-sub male pin 3
29 REL3 NO Not in use
30 REL3 COM Link to pin 36 on thisconnector
31 REL2 NC D-sub male pin 2
32 REL2 NO Not in use
33 REL2 COM Link to pin 36 on thisconnector
34 REL1 NC D-sub male pin 1
35 REL1 NO Not in use
36 REL1 COM D-sub male pin 9 + link toabove
Note
If necessary, use a screwdriver to remove the CON5 connector from theWPUB before changing the polarity. Reinstall the CON5 connector after thepolarity has been changed.
DN7062824Issue 2 en
# Nokia Corporation 99 (107)
Installing options
8.4.6 Changing the alarm polarity of the WPUC unit
Before you start
There are eight galvanic isolated alarm contacts for remote supervision of thealarms. Each alarm contact represents different alarm conditions. Alarm relaycoils are powered during normal operation. All alarm relays will give an alarmwith no AC or DC power connected to the system.
Figure 31. Alarm connection, 9-pin D-sub
Note
While it is recommended to change the polarity before installing the unit intothe cabinet, with the WPUC unit it is also possible to do this later.
Alarm 1: Pin 1Alarm 2: Pin 2Alarm 3: Pin 3Alarm 4: Pin 4Alarm 5: Pin 5Alarm 6: Pin 6Alarm 7: Pin 7Alarm 8: Pin 8Common: Pin 9
Alarms EAC
1 2 3 4 5
6 7 8 9
DN0570839
100 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Note
Always use the antistatic wrist strap when handling the WPUC.
Steps
1. Loosen the fixing screw and pull out the alarm interface unit using thehandle.
2. Use JP8 for setting the alarm relays to closed on alarm or open onalarm.
The jumper mounted between pins 1 and 2 on the jumpers (default) meansclosed on alarm for the corresponding relay.
The jumper mounted between pins 2 and 3 on the jumpers means open onalarm for the corresponding relay.
The jumper numbers correspond to the relay numbering (for instance, JP5to RL5).
Note
When the jumpers are mounted between pins 1 and 2, the alarm polarity isNormally Open. When the jumpers are mounted between pins 2 and 3, thealarm polarity is Normally Closed.
DN7062824Issue 2 en
# Nokia Corporation 101 (107)
Installing options
Figure 32. Alarm interface unit from above
3. Reinstall the alarm interface unit.
8.5 Installing fire detector
Before you start
Check that the cabinet roof has been removed. Remove the plastic cover from thefire detector before installing it.
When using the fire detector, the FSEA box is needed.
Q5
R64 R62 R60 R90 R82 R84 R85R63 R61
JP5
Jumper settings
Alarm
sEAC
RL6
RL8
C21
R30
R21D3
R37 P2
P3
JP3
JP41
R26D1
D4
1 1
JP12
11
JP11
JP10
JP9
1 1
JP8
JP7
1 1
JP6
RL5
RL7
RL10 RL9
RL12 RL11
J12
SC6
R29
JP2
C24
Q6
DN0570842
J1
102 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
Summary
Figure 33. Installing fire detector
Steps
1. Strip the fire detector cable as needed.
2. Make the power and alarm connections.
3. Slide the notches in the fire detector back plate in the slots on thecabinet roof.
4. Turn the fire detector in an upright position.
5. Fix with one M5 screw.
DN7068133
Back side
3
1
2
3
DN7062824Issue 2 en
# Nokia Corporation 103 (107)
Installing options
6. Fix the cable with cable ties.
104 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
9 Installation tools and torque values
9.1 FCOA installation tools and equipment
This section lists the installation tools and equipment.
Table 4. Tools for installation
Installation tools
Allen key:
5 mm (0.20 in.)
ESD wrist strap and cable
TORX screwdriver set: T10, T20, T25
Screwdriver slotted for power input connections
Wrench 13 mm (0.51 in.)
Folding knife
Monkey wrench
Side cutters
Torque wrench for antenna cables: Open spanner end with bended shank 32mm@25Nm (DIN 7-16 connector)
Socket or open ended spanner set: 11 mm (0.43 in.), 13 mm (0.51 in.), 17 mm (0.67in.), 18 mm (0.71 in.)
Open ended spanner 22 mm or tongs
Lint-free swab or wipe and 99% alcohol for cleaning optical connectors
Cable ties for routing cables
Tape measure
Flashlight, pocket lamp or torch
Hammer drill
Marker pen or comparable tool
Pliers
DN7062824Issue 2 en
# Nokia Corporation 105 (107)
Installation tools and torque values
9.2 Torque values
Nokia strongly recommends that you tighten to the following torque values.These values assume the use of a lubricated bolt or fastener. Use these valuesunless stated otherwise.
Table 5. Torque values for the BTS
Bolt/Screw Type DIN Size Torque
TORX head screwcylinder head
7985 F1-60 M3 0.7 - 1.0 Nm
(0.5 - 0.7 ft-lb)
TORX head screwcylinder head
7985 F1-60 M4 1.2 - 1.6 Nm
(0.9 - 1.2 ft-lb)
TORX head screwcylinder head
7985 F1-60 M5 2.0 - 2.5 Nm
(1.5 - 1.8 ft-lb)
TORX head screwcylinder head
7985 F1-60 M8 10.0 Nm
(7.4 ft-lb)
Hexagon head screw(cabinet fixing)
933-12-70 M12 49.0 Nm
(36.1 ft-lb)
Allen screw 912-A2-70 M8 8.0 - 10.0 Nm
(5.9 - 7.4 ft-lb)
Nut 934 A2 M5 3.7 Nm
(2.7 ft-lb)
Nut (cabinet fixing) 934 A2 M12 49 Nm
(36.1 ft-lb)
Knurled-head screw(finger tightening)
-NA- M5 approx. 1 Nm
(0.7 ft-lb)
Fan fixing screws,plastic
-NA- M4 0.7 Nm
(0.5 ft-lb)
Fan fixing screws,metal
-NA- M4 1.2 Nm
(0.9 ft-lb)
106 (107) # Nokia Corporation DN7062824Issue 2 en
Installing Flexi Cabinet for Outdoor
10 Checklist for installing FCOA
Work phase Checked
Delivery is complete and undamaged.
Cabinet is anchored according to the instructions.
Cabinet is grounded.
Site support module and IBBU are installed (if applicable).
Air filter is installed (if applicable).
Fire detector is installed (if applicable).
Modules are installed according to the instructions.
External power feed cable is connected.
External antenna feeder cables are connected.
External transmission cable is connected.
External alarm cable is connected (if applicable).
Cables are routed and connected correctly.
Empty slots are covered with dummy panels.
Cabinet security lock is installed (if applicable) and thecabinet can be locked.
Cabinet roof is installed.
DN7062824Issue 2 en
# Nokia Corporation 107 (107)
Checklist for installing FCOA