Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara , Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department of Ophthalmology University of Auckland, New Zealand nz national eye centre The authors have no financial interests to disclose
10

Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Dec 19, 2015

Download

Documents

Brenda Logan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus

Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel

Department of OphthalmologyUniversity of Auckland, New Zealand

nz national eye centre

The authors have no financial interests to disclose

Page 2: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Biomechanics

Elastic

Viscous

The cornea is viscoelastic

Page 3: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Biomechanics & Keratoconus

Keratoconus – underlying biomechanical failure

Penetrating Keratoplasty (PKP)

Deep Anterior Lamellar Keratoplasty (DALK)

End stage management options

Page 4: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Aims

• To determine if corneal biomechanics are closer to normal after corneal transplantation

• To determine the effect of corneal transplantation type on corneal biomechanical properties

Page 5: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Methods

• Prospective cross sectional study• 33 PKP and 23 DALK eyes

• Exclusion: <3/12 post-surgerycorneal oedemacurrent rejection raised IOP

• Examinations:Slit-lampPentacam tomographyAS – OCTCorVis ST

Page 6: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

CorVis ST

What is it?• Air Tonometer• Ultra high speed Scheimpflug

camera

How does it work?• Air puff indents cornea• Video 4333 frames/sec• Calculates a range of output

measurements• Parameters describe in vivo biomechanics

Page 7: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

CorVis ST - Parameters• Applanation1

• Time• Length• Velocity

• Highest Concavity• Deformation

Amplitude (DA)• Radius of Curvature

(RoC)• Peak Distance (PD)

• Applanation2• Time• Length• Velocity

Comparison of above parameters between PKP and DALK

Page 8: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

ResultsMean PKP DALK p-valueAge (years): 35.6 37.5 0.61Time from surgery (months): 83.2 91.1 0.42Corneal thickness (µm): 534 594 <0.001Peak distance (PD) 4.8 3.4 0.03

All other CorVis ST parameters: p-value (>0.05)

CorVis ST – PKP vs. DALK

Two corneas overlapped at highest concavity (similar CCT and IOPs).

Page 9: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Results – See attached videoPKP vs. DALK vs. Normal

PKP vs. DALK vs. KCDA 1.16 1.18 1.38RoC 7.20 6.31 4.79

3 corneas overlapped at highest concavity. The deformation profiles are very similar.

p-value: <0.05

3 corneas overlapped at highest concavity. The deformation profile of the keratoconic cornea (green) differs from the others.

Page 10: Influence of Keratoplasty Technique on Corneal Biomechanical Properties in Keratoconus Hans R Vellara, Noor Q Ali, Charles NJ McGhee, Dipika V Patel Department.

Conclusion

• Corneal biomechanical properties after PKP and DALK are similar

• However, the difference in PD may indicate a more viscous cornea after DALK

• Biomechanical properties after corneal transplant for keratoconus resemble normal corneas