Top Banner
Industry-Relay Pluggable Construction SKR 115 3 pole 10A ELESTA Page 1 of 3 Technical Data Contact Data Type of Contact Single Contact Double Contact No. of Contacts 3C Rated Voltage / Max. Switching Voltage VAC 250 / 440 Rated Current A 10 6 Inrush Current A 40 15 Rated Breaking Capacity (cos j = 1) VA 2500 1500 Contact Material AgCuNi; AgCuNi +htv General Data Mechanical Data > Operations 100 x 10 6 Electrical Life at Rated Voltage > Operations 7 x 1 0 5 1,5 x 10 5 Max. Switching Frequency Operations / h 360 Operate Time / Release Time DC approx. in m,s 1 2 / 3 , 5 Operate Time / Release Time AC approx. in ms 3 - 1 0 / 2 -15 Bounce Time A / B DC approx. in ms 3,5 / 9 Bounce Time A / B AC approx. in ms 3-6 / 6-11 Test Voltage Contact / Coil VAC eff 2000 Test Voltage Contact Open VAC eff 1500 Test Voltage Contact Poles VAC eff 1500 Vibration Resistance A / B (10-500Hz) 7g / 4g Creeping-/Leakage Distance mm 2 / 3 Insulation Group / Rated Voltage (VDE 0110b 2/79) / 250 C Ambient Temperature °C -40…+75/+105 Approvals VDE; UL; CSA; Weight gr. 80 Coil at + 20°C Rated Voltage VDC 12…110 Rated Voltage VAC 12…230 Power Consumption (DC – Coil) approx. W 1,2 Power Consumption (AC – Coil) VA 2,5 DC-Coil U N (V) R (Ohm) U AN (V) U AB (V) I N (mA) 12 115 ± 10% £ 9,6 0,6 104,0 24 480 ± 10% £ 19,2 1,2 50,0 48 1850 10% ± £ 38,4 2,4 25,9 110 9000 ± 10% £ 88,0 5,5 12,2 AC-Coil U N (V) R (Ohm) U AN (V) U AB (V) I N (mA) 12 13,3 ± 10% £ 9,6 1,8 211,0 24 52,0 ± 10% £ 19,2 3,6 104,0 48 240,0 ± 10% £ 38,4 7,2 55,0 110 1120 ± 10% £ 88,0 16,5 23,0 230 5600 ± 10% £ 184,0 34,5 11,5 Other coil tensions on request. Dimension Diagram All measure in mm. ELESTA GmbH Elektronik – Phone: +49 6039 / 489-661 - Fax: +49 6039 / 489-660 - [email protected] - www.elesta.com
3

Industry-Relay Pluggable Construction ELESTA SKR 115 3 ... · SKR 115 3 pole 10A ELESTA Page 1 of 3 Technical Data Contact Data Type of Contact Single Contact Double Contact No. of

Oct 05, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Industry-Relay Pluggable Construction ELESTA SKR 115 3 ... · SKR 115 3 pole 10A ELESTA Page 1 of 3 Technical Data Contact Data Type of Contact Single Contact Double Contact No. of

Industry-Relay Pluggable Construction SKR 115 3 pole 10A

ELESTA

Page 1 of 3

Technical Data

Contact Data

Type of Contact Single Contact Double Contact

No. of Contacts 3C

Rated Voltage / Max. Switching Voltage VAC 250 / 440

Rated Current A 10 6

Inrush Current A 40 15

Rated Breaking Capacity (cos j = 1) VA 2500 1500

Contact Material AgCuNi; AgCuNi +htv

General Data

Mechanical Data > Operations 100 x 106

Electrical Life at Rated Voltage > Operations 7 x 1 0 5 1,5 x 10

5

Max. Switching Frequency Operations / h 360

Operate Time / Release Time DC approx. in m,s 1 2 / 3 , 5

Operate Time / Release Time AC approx. in ms 3 - 1 0 / 2 -15

Bounce Time A / B DC approx. in ms 3,5 / 9

Bounce Time A / B AC approx. in ms 3-6 / 6-11

Test Voltage Contact / Coil ≥ VACeff 2000

Test Voltage Contact Open ≥ VACeff 1500

Test Voltage Contact Poles ≥VACeff 1500

Vibration Resistance A / B (10-500Hz) 7g / 4g

Creeping-/Leakage Distance mm 2 / 3

Insulation Group / Rated Voltage (VDE 0110b 2/79) / 250 C

Ambient Temperature °C -40…+75/+105

Approvals VDE; UL; CSA;

Weight gr. 80

Coil at + 20°C

Rated Voltage VDC 12…110

Rated Voltage VAC 12…230

Power Consumption (DC – Coil) approx. W 1,2

Power Consumption (AC – Coil) VA 2,5

DC-Coil

UN (V) R (Ohm) UAN (V) UAB (V) IN (mA)

12 115 ± 10% £ 9,6 ≥ 0,6 104,0

24 480 ± 10% £ 19,2 ≥ 1,2 50,0

48 1850 10%± £ 38,4 ≥ 2,4 25,9

110 9000 ± 10% £ 88,0 ≥ 5,5 12,2

AC-Coil

UN (V) R (Ohm) UAN (V) UAB (V) IN (mA)

12 13,3 ± 10% £ 9,6 ≥ 1,8 211,0

24 52,0 ± 10% £ 19,2 ≥ 3,6 104,0

48 240,0 ± 10% £ 38,4 ≥ 7,2 55,0

110 1120 ± 10% £ 88,0 ≥ 16,5 23,0

230 5600 ± 10% £ 184,0 ≥ 34,5 11,5 Other coil tensions on request.

Dimension Diagram

All measure in mm.

ELESTA GmbH Elektronik – Phone: +49 6039 / 489-661 - Fax: +49 6039 / 489-660 - [email protected] - www.elesta.com

Page 2: Industry-Relay Pluggable Construction ELESTA SKR 115 3 ... · SKR 115 3 pole 10A ELESTA Page 1 of 3 Technical Data Contact Data Type of Contact Single Contact Double Contact No. of

Industry-Relay Pluggable Construction SKR 115 3 pole 10A

ELESTA

Page 2 of 3

Schematic Diagram

Order Type

SKR 115 A 024VDC

Relay Type

115 = 3 Change-Over Contact Construction

A = Mechanical Position Indication (standard) B = Without Manual Actuation D = Double Contact F = Free Wheeling Diode L = Electrical Position Indication T = Push-Button Actuation

Coil Voltage 012VDC = 12VDC ...110VDC = 110VDC 012VAC = 12VAC....230VAC = 230VAC

Contact Material Without = AgCuNI

Further constructions on request!

ELESTA GmbH Elektronik – Phone: +49 6039 / 489-661 - Fax: +49 6039 / 489-660 - [email protected] - www.elesta.com

Page 3: Industry-Relay Pluggable Construction ELESTA SKR 115 3 ... · SKR 115 3 pole 10A ELESTA Page 1 of 3 Technical Data Contact Data Type of Contact Single Contact Double Contact No. of

Industry-Relay Pluggable Construction SKR 115 3 pole 10A

ELESTA

Se 3 of 3

Single Contact

Double Contact

Electrical Specification

Load Limit Curve for Direct Current

Voltage (VDC)

1) Inductive Load, L/R 40 ms 2) Resitive Load

Cu

rre

nt

(A)

Contact Life Time

Nu

mb

er

of

Op

era

tion

s

Switching Current (A)

- AC Load Cos Phi (AC1) - 250 VAC 50Hz 360 Operations/h

Load Limit Curve for Direct Current Contact Life Time

Cu

rre

nt

(A)

Nu

mb

er

of

Op

era

tion

s

Voltage (VDC)

1) Inductive Load, L/R 40 ms 2) Resitive Load

Switching Current (A)

- AC Load Cos Phi (AC1) - 250 VAC 50Hz 360 Operations/h

ELESTA GmbH Elektronik – Phone: +49 6039 / 489-661 - Fax: +49 6039 / 489-660 - [email protected] - www.elesta.com