Inductive proximity switch IKL 010.05 GH 15.05.2002 Details are subject to change without notice. WG 210 Proxitron GmbH - Grtnerstr. 10 - D-25335 Elmshorn - Tel. 04121/2621-0 - Fax. 04121/24404 - [email protected]I363E Short circuit protected proximity switch with AC/DC 2-wire technology. The Sensor is suitable for higher ambient temperature by the increased temperature range. Technical Data Type IKL 010.05 GH Connection Art.-No. 2 m silicone cable (SIK) 2434D 5 m silicone cable (SIK) 7 m silicone cable (SIK) 2434D-5 2434D-7 20 m silicone cable (SIK) 2434D-20 Rated operating distance (Sn) 10 mm Output normally open Operating distance adjustable no Target steel St37, 1 mm thick 30 x 30 mm Location at metal flush Supply voltage (UB) 20 - 260 V AC/DC Power frequency 40 - 440 Hz Ripple voltage max. 15 % (DC) Load current max. 5 - 400 mA Short- time load current 0,8 A / 100 ms 2 A / 10 ms Short circuit protection yes Residual current (Ir) 1,7 mA / 260 V AC 1,0 mA / 24 V DC Voltage drop (Ud) 9 V Operating frequency AC/DC (f) 25 Hz / 100 Hz Switching hysteresis (H) 1 - 15 % Ambient temperature -20 ... +100 C Protection class IP 67 Function display LED Housing material plastic PBT Diagram of Connections
14
Embed
Inductive proximity switch IKL 010.05 GH Series4.pdf · Inductive proximity switch IKL 015.31 GH 21.01.2002 Details are subject to change without notice. WG 210 Proxitron GmbH - Gärtnerstr.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Inductive proximity switchIKL 010.05 GH
15.05.2002 Details are subject to change without notice. WG 210
Short circuit protected proximity switch withAC/DC 2-wire technology.
The Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 010.05 GH
Connection Art.-No.2 m silicone cable (SIK) 2434D5 m silicone cable (SIK)7 m silicone cable (SIK)
2434D-52434D-7
20 m silicone cable (SIK) 2434D-20
Rated operating distance (Sn) 10 mmOutput normally openOperating distance adjustable noTarget steel St37, 1 mm thick 30 x 30 mmLocation at metal flushSupply voltage (UB) 20 - 260 V AC/DCPower frequency 40 - 440 HzRipple voltage max. 15 % (DC)Load current max. 5 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yesResidual current (Ir) 1,7 mA / 260 V AC
1,0 mA / 24 V DCVoltage drop (Ud) 9 VOperating frequency AC/DC (f) 25 Hz / 100 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switchIKL 015.31 GH
21.01.2002 Details are subject to change without notice. WG 210
Short circuit protected proximity switch for10 � 55 V DC with 3-wire technology.NPN � normally openThe Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 015.31 GH
Connection Art.-No.2 m silicone cable (SIK) 2319H20 m silicone cable (SIK) 2319H-20
Rated operating distance (Sn) 15 mmOutput NPN n. o.Operating distance adjustable noTarget steel St37, 1 mm thick 45 x 45 mmLocation at metal non flushSupply voltage (UB) 10 - 55 V DCRipple voltage max. 15 %Load current max. 0 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yes, pulsingNo load current (I0) < 10 mAVoltage drop (Ud) 1,5 V / 50 mAOperating frequency (f) 200 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switchIKL 015.30 GH
21.01.2002 Details are subject to change without notice. WG 210
Short circuit protected proximity switch for10�55 V DC with 3-wire technology.NPN � normally closedThe Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 015.30 GH
Connection Art.-No.2 m silicone cable (SIK) 2319I20 m silicone cable (SIK) 2319I-20
Rated operating distance (Sn) 15 mmOutput NPN n. c.Operating distance adjustable noTarget steel St37, 1 mm thick 45 x 45 mmLocation at metal non flushSupply voltage (UB) 10 - 55 V DCRipple voltage max. 15 %Load current max. 0 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yes, pulsingNo load current (I0) < 10 mAVoltage drop (Ud) 1,5 V / 50 mAOperating frequency (f) 200 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switchIKL 015.05 GH
15.03.2006 Details are subject to change without notice. WG 210
Short circuit protected proximity switch withAC/DC 2-wire technology.
The Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 015.05 GH
Connection Art.-No. 2 m silicone cable (SIK) 2377C 5 m silicone cable (SIK) 2377C-510 m silicone cable (SIK) 2377C-1015 m silicone cable (SIK) 2377C-1520 m silicone cable (SIK) 2377C-20
Rated operating distance (Sn) 15 mmOutput normally openOperating distance adjustable noTarget steel St37, 1 mm thick 45 x 45 mmLocation at metal non flushSupply voltage (UB) 20 - 260 V AC/DCPower frequency 40 - 440 HzRipple voltage max. 15 % (DC)Load current max. 5 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yesResidual current (Ir) 1,7 mA / 260 V
AC1,0 mA / 24 V DC
Voltage drop (Ud) 9 VOperating frequency AC/DC (f) 25 Hz / 100 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switchIKL 015.04 GH
06.03.2002 Details are subject to change without notice. WG 210
Short circuit protected proximity switch withAC/DC 2-wire technology.
The Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 015.04 GH
Connection Art.-No.2 m silicone cable (SIK) 2376E15 m silicone cable (SIK) 2376E-1520 m Silikonkabel (SIK) 2376E-20
Rated operating distance (Sn) 15 mmOutput normally closeOperating distance adjustable noTarget steel St37, 1 mm thick 45 x 45 mmLocation at metal non flushSupply voltage (UB) 20 - 260 V AC/DCPower frequency 40 - 440 HzRipple voltage max. 15 % (DC)Load current max. 5 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yesResidual current (Ir) 1,7 mA / 260 V
AC1,0 mA / 24 V DC
Voltage drop (Ud) 9 VOperating frequency AC/DC (f) 25 Hz / 100 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switchIKL 010.33 GH
04.12.2006 Details are subject to change without notice. WG 210
Short circuit protected proximity switch for10�55 V DC with 3-wire technology.NPN � normally openThe Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 010.31 GH
Connection Art.-No.2 m silicone cable (SIK) 2434G10 m silicone cable (SIK) 2434G-1020 m silicone cable (SIK) 2434G-20
Rated operating distance (Sn) 10 mmOutput NPN n. o.Operating distance adjustable noTarget steel St37, 1 mm thick 30 x 30 mmLocation at metal flushSupply voltage (UB) 10 - 55 V DCRipple voltage max. 15 %Load current max. 0 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yes, pulsingNo load current (I0) < 10 mAVoltage drop (Ud) 1,5 V / 50 mAOperating frequency (f) 200 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switchIKL 010.30 GH
21.01.2002 Details are subject to change without notice. WG 210
Short circuit protected proximity switch for10�55 V DC with 3-wire technology.NPN � normally closedThe Sensor is suitable for higher ambienttemperature by the increased temperaturerange.
Technical DataType IKL 010.30 GH
Connection Art.-No.2 m silicone cable (SIK) 2434K20 m silicone cable (SIK) 2434K-20
Rated operating distance (Sn) 10 mmOutput NPN n. c.Operating distance adjustable noTarget steel St37, 1 mm thick 30 x 30 mmLocation at metal flushSupply voltage (UB) 10 - 55 V DCRipple voltage max. 15 %Load current max. 0 - 400 mAShort- time load current 0,8 A / 100 ms
2 A / 10 msShort circuit protection yes, pulsingNo load current (I0) < 10 mAVoltage drop (Ud) 1,5 V / 50 mAOperating frequency (f) 200 HzSwitching hysteresis (H) 1 - 15 %Ambient temperature -20 ... +100 °CProtection class IP 67Function display LEDHousing material plastic PBT
Diagram of Connections
Inductive proximity switch
IKL 025.38 GHS4
09.09.13 nb Details are subject to change without notice. WG 210
Short circuit protected proximity switch for higher sensing ranges 10 – 55 V DC with 3-wire technology.
PNP – normally open
The Sensor is suitable for higher ambient temperature by the increased temperature range.
Technical Data
Type IKL 025.33 GH
Connection Art.-No. 2 m silicone cable (SIK) 2413B 5 m silicone cable (SIK) 2413B-5 10 m silicone cable (SIK) 2413B-10 15 m silicone cable (SIK) 2413B-15 20 m silicone cable (SIK) 2413B-20
Rated operating distance (Sn) 25 mm
Output PNP n. o.
Operating distance adjustable no
Target steel St37, 1 mm thick 75 x 75 mm
Location at metal non flush
Supply voltage (UB) 10 - 55 V DC
Ripple voltage max. 10 %
Load current max. 0 - 400 mA
Short circuit protection yes, pulsing
No load current (I0) < 10 mA
Voltage drop (Ud) < 2,5 V
Operating frequency (f) 200 Hz
Switching hysteresis (H) 1 - 15 %
Ambient temperature -25 up to +100 °C
Protection class IP 68/ IP 69K
Function display LED
Housing material plastic
Diagram of Connections
Fronllron$engoren fur Automation
Short circuit protected proximity switch withextended operation distance and M30 plastichousing with AC/DC 2-wire technology.
Inductive proximity switchrKL 020.05 G
Technical DataType
Connection2 m cable PVC
Rated operating distance (Sn)OutputOperating distance adjuslableTarget steel St37, 1 mm thickLocation at metalSupply voltage (Ua)Power frequencyLoad current max.Short- time load currentShort circuit protectionResidual current (lr)Voltage drop (Uo)Operating frequency (f)Switching hysteresis (H)Ambient temperatureProtection classFunction displayHousing material