Top Banner
STANDARD COOLING OR HEATING CONDITIONS DISTRICT COOLING CONDITIONS Hydronic Fan Coil Units
20

Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

Apr 05, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

STANDARD COOLING OR HEATING CONDITIONSDISTRICT COOLING CONDITIONS

Hydronic Fan Coil Units

Page 2: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 3: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 4: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4

Page 5: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4

Page 6: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 7: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 8: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 9: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 10: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 11: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 12: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

SU---CW Series

Descriptions Model SU10MPVC/H-CW

SU13MPVC/H-CW

SU18MPVC/H-CW

SU24MPVC/H-CW

SU32MPVC/H-CW

SU36MPVC/H-CW

SU48MPVC/H-CW

SU60MPVC/H-CW

Note: Cooling and heating capacities are based on : 1. Cooling(A):Inlet water temperature 7 ํC,outlet water temperature 12 ํC ;Inlet air temperature 27 ํCDB and 19 ํC WB at Turbo Fan Speed.2. Heating(B): Inlet water temperature 50 ํC; same water flow rate as in cooling;Inlet air temperature 20 ํCDB .3. Heating(C):Inlet water temperature 70 ํC ; Outlet water temperature 60 ํC; Inlet air temperature 20 ํCDB.* Air flow rate is measured on wet coil operation. ** Pressure Drops are measured without any watervalve.

Chilled Water Cooling (A)

Hot Water Heating (B)

Hot Water Heating (C)

Drain Pipe Connection

Evaporator

Fan

Fan Motor

Sound Pressure Level

Nominal Air Flow Rate

DimensionsNet Weight

Inlet & Outlet PipeConnection

HxWxDT/H/M/L

Running Current

T/H/M/L

Power InputPower SupplyTypeNo.TypeTube DiameterFin Type / Fin PitchDiameter (OD)Nominal DiameterTypePressure DropWater Flow RateTotal CapacityCapacityPressure DropWater Flow RateTotal Capacity Watts

L/HrkPa

WattsWattsL/HrkPa

InchInch

mm.

V/Ph/HzWatts

A

m3/hr

dB(A)mm.Kg.

270046214

3690634055614

Louvre/1.41 Louvre/1.58 Louvre/1.81 Louvre/2.11 Louvre/1.81

348059317

4210707062015

5980102616

748012610110516

6500111519

817013780120817

1/2 3/4 1

432

620.25

7780133521

1047017910157121

10040172145

1236020800182438

13020223430

1704028940254029

15220261034

1924032500285031

660x860x20030

43/42/41/39

510/480/450/420

42/41/39/37

500/470/440/410

45/44/41/39

960/940/885/820

31 41660x1256x200

900.4

48/47/44/42

1070/990/980/900

660x1256x235 660x1650x235

1040.46

48/46/44/42

1780/1680/1580/1500

1770/1680/1600/1520

1940.84

49/47/44/42

0.85

660x1862x27352/51/49/47

2410/2270/2130/2000

2650/2430/2280/2060

3902.25

52/51/50/48

43 55 57 66 73

OD. 16 mm.

Male Thread Water Pipe Conector

O 9.5/Smooth Inside WallDouble Inlet Centrifugal Fan

Permanent Split Capacitor220-240/1/50

Floor-Ceiling Fan Coil UnitsStandard Cooling Conditions

SU---DW SeriesFloor-Ceiling Fan Coil UnitsDistrict Cooling Conditions

S p e c i f i c a t i o n s

Descriptions Model SU10MPVC/H-DW

SU13MPVC/H-DW

SU18MPVC/H-DW

SU24MPVC/H-DW

SU32MPVC/H-DW

SU36MPVC/H-DW

SU48MPVC/H-DW

SU60MPVC/H-DW

T/H/M/L

Chilled Water Cooling (A)

Drain Pipe Connection

Evaporator

Fan

Fan Motor

Sound Pressure Level

Nominal Air Flow Rate

DimensionsNet Weight

Inlet & Outlet PipeConnection

HxWxDT/H/M/L

Running CurrentPower InputPower SupplyTypeNo.TypeTube DiameterFin Type / Fin PitchRowDiameter (OD)Nominal DiameterTypePressure DropWater Flow RateTotal Capacity Watts

L/HrkPa

InchInch

mm.

V/Ph/HzWatts

A

m3/hr

mm.Kg.

11701123.5

Louvre/1.412 3 2 3

Louvre/1.58 Louvre/1.81

252024011

447042613

484046215

1/2 3/4 1

432

620.25

552052717

694066215

940089721

10620101320

660x860x20030

43/42/41/39

510/480/450/420

42/41/39/37

500/470/440/410

45/44/41/39

960/940/885/820

31 41660x1256x200

900.4

48/47/44/42

1070/990/980/900

660x1256x235 660x1650x235

1040.46

48/46/44/42

1780/1680/1580/1500

1770/1680/1600/1520

1940.84

48/47/44/42

0.85

660x1862x27352/51/49/47

2410/2270/2130/2000

2650/2430/2280/2060

3902.25

52/51/50/48

43 55 57 66 73

OD. 16 mm.

Male Thread Water Pipe Connector

O 9.5 SmoothDouble Inlet Centrifugal Fan

Permanent Split Capacitor220-240/1/50

Note: Cooling capacities are based on :1. Inlet water temperature 5.5 ํC,outlet water temperature 14.5 ํC ;Inlet air temperature 24 ํCDB and 18 ํC WB at Turbo Fan Speed.* Air Flow Rate is measured on wet coil operation. ** Pressure Drops are measured without any water valve.

S p e c i f i c a t i o n s

11

Page 13: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 14: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 15: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or
Page 16: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

S p e c i f i c a t i o n s

Page 17: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

S p e c i f i c a t i o n s

Page 18: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

LC LCB

1

Page 19: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

LC LCB

Page 20: Hydronic Fan Coil Units - Altitude Trading · Hydronic Fan Coil Units. Hydronic Fan Coil Units Standard Cooling or Heating Conditions 4. Hydronic Fan Coil Units Standard Cooling or

CONTACT DETAILS

PO BOX 384 KELLYVILLE SYDNEY NSW 2155

Phone 1300 725 408 www.altitudetrading.com.au

[email protected]