Electronic scoring systems SIUS AG Im Langhag 1 | CH-8307 Effretikon | Switzerland Phone +41 52 354 60 60 www.sius.com | [email protected] • Installation • Start-up • Maintenance HS10 HYBRIDSCORE ®
20

HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

Jul 30, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

Electronic scoring systems

SIUS AGIm Langhag 1 | CH-8307 Effretikon | Switzerland

Phone +41 52 354 60 60www.sius.com | [email protected]

• Installation• Start-up• Maintenance

HS10 HYBRIDSCORE®

Page 2: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

2

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Table of contents InstallationAssembly of the target – airguns 10m 2–3Assembly of the target – small bore rifle 50m 4–6Connections and laying of cables 7Mounting of target – airguns 10m 8–9Example of an installation – airguns 10m 10Example of an installation (overview) – airguns 10m 11Mounting of target – small bore rifle 50m 12Example of an installation – small bore rifle 50m 13Example of an installation (overview) – small bore rifle 50m 14Wiring installation (cables and power supply) 15

Start-upBringing into service 16–17

MaintenanceMaintenance and function test 18–19

Page

Assembly of the target – airguns 10m

Article no. HS10V0 (with digital display)Complete target incl. reinforced front frame for airgunsand integrated target illumination

Manual HS10 Stand-alone with remote control: www.sius.com > Products > Sport > Targets > HS10 > «Manual HS10 Stand-alone – Installation and Start-up»

1.1

1.1

Article no. HS10V1 (without digital display)Complete target incl. reinforced front frame for airgunsand integrated target illumination

1.2

Article no. HS10AN003Target holder incl. bullet trap for airguns

1.2

Installation

Page 3: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

3

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Mounting of the target front mask (glossy side inside)

Mounting of optional backing target for manual shot control(to be inserted into the provided slot in the bullet trap)

Assemble the target and the target holder.

3.1 Assembly of target

Push the locking plate to the side and mount the target on both sides into the target holder.

Pull the target upwards and move it towards the target holder.

Page 4: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

4

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Assembly of target – small bore rifle 50m

Article no. HS10V1Complete target incl. reinforced front frame for airgunswithout digital display

Installation

Installation of therubber sheet

Article no. HS10AN001Target holderincl. rubber sheet Article no. LS10A042(the rubber sheet protects against sun and debris from the bullet trap)

Assemble the target and the target holder.

Push the locking plate to the side and mount the target on both sides into the target holder.

Pull the target upwards and move it towards the target holder.

Assembly of the target

Page 5: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

5

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Article no. HS10A026Rubber membrane in front(used for acoustic measurement)

Installation of rubber membrane in front, inside the target (Position of blanked out hole = at the bottom of the target)

4x

AMSZI06x10

AMU042

AMA178

4x

2x

Article no. LS10AN008Mounting plate

Installation of the target holder on the mounting plate.

Screw the parts together.

2x

AMSLT04x08Art.-Nr. HS10AN011Shatter protection

Insert the shatter protection.

Press apart, so that the edges of the target snap into thecorresponding slots of the shatter protection.

Page 6: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

6

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Installation

Installation of weather protection box on the mounting plate.

Installation of the target holder on the mounting plate.(Assembly of target and target holder according to page 4, point 3)

Installation of the reinforced frontframe on the mounting plate.

1x

2x

4x

Article no. LS10AN010Weather protection box

4x

LS10A058

AMSLT04x06

AMSLT04x06

AMU011

Closure ofweather protection box.

Article no. HS10AN007Reinforced front frame for small bore rifleand Article no. HS10A052, target front mask 50mfor small bore rifle

Installation of target front mask on the reinforced front frame.

Installation of the reinforced front frame on the mounting plate.

Page 7: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

7

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Connections and laying of cables

Cable relief at target holder/bullet trap and laying of cables from behind into the target.

1 Remote control for target with digital display2 Power supply for target with digital display resp. stand-alone version with SIUSLANE software3 Plug-in for target print4 LTW-network-connection (Cabeling according to draft on page 15)5 Target elevator

1 2 3 4 5

Laying of cables and cable relief.

or

Page 8: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

8

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Installation

Mounting of the target – airguns 10m

Installation on pedestal, Article no. SHS08

1. Assembly of the pedestala) Mounting of feets

b) Fixation of retainer rod

Bigopening

Smallopening

2. Mounting the holder on the bullet trapAssemble the holder (needed for installationon the pedestal) and the bullet trap.

3. Attaching the bullet trap to the pedestalThe guide rail of the holder enables the mounting of the bullet trap to the pedestal.

With the upper screw (a) the height can be adjusted variably.

The lower screw (b) enables the fixed setting of the 3 positions (standing 140cm > kneeling 80cm prone 50cm) trough the pro-vided holes in the retainer rod.

a

b

21cm21cm

Distance betweentarget and wall is 21cm(= backside feet)

Page 9: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

9

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Installation on automated target elevator ATE10

Mounting of the target – airguns 10m

Mounting to the wall

Mounting the target to the wall through the holes on the back of the target holder.

3 positions target elevator for HS10. Mobile or fixed installation pos-sible.The target is attached to the electronic target elevator from the back.

Detailed information: installation manual ATE10 for HS10«B-INBE-ATE10V1/2-de»

Page 10: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

10

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Example of an installation – airguns 10m

Mounting to the wall

Installation

Pow

er s

ocke

t for

pow

er s

uppl

y(c

onst

ruct

ion

side

)

Pow

er s

uppl

y fo

r 10

lines

(SIU

S)

Line

1Li

ne 2

Line

9Li

ne 1

0Li

ne 1

1

Tube

Ø 5

0mm

(con

stru

ctio

n si

de)

pref

erab

ly w

ith

inse

rted

taut

wire

Woo

d pl

ate,

thic

knes

s m

in. 2

5mm

, hi

ght 4

00m

m(c

onst

ruct

ion

side

)

Spa

ce fo

r cab

les

Woo

d be

am 1

00/1

00m

m(c

onst

ruct

ion

side

)

Page 11: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

11

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Example of an installation (overview) – airguns 10m

Mounting to the wall

Target HS10 with illumination(SIUS)

Connection box 300x300x200mm(construction side)

Tube Ø 50mm in ground(construction side)preferably with inserted taut wire

Illumination:Do not use halogen lamps or electric bulbs. Infrared light could interfere with the system.For all outside installations we recommend CFL / gas discharge lamps.

Page 12: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

12

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Mounting of target – small bore rifle 50m

Installation on automated target elevator ATE10 Installation on a beam

By using the mounting plate the target can be fixed on the beam.Be aware, that the target should not be exposed to directsunlight.

Installation

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

REV Änderungen Datum Name

Datum NameGez.Gepr.Norm.

Maßstab Blatt

Installation HS10 mit Prellschutz 50m

23.01.2012 ew

1

A3

.

.

D:\Products\TARGETS\DetectionSystems\HS10\Mechanik\HS10\Kleinkaliber\Installation HS10 mit Prellschutz 50m.idw

.

1:5

Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS

35 *

209

557

470

85 * 300 * 85 *

269

185 6

51.5

191

450min forsun protection

392

50-100

45.5

4

30 * 410 *

470

30 *

310

115

*42

*

* = Montage, Alle Löcher für Schrauben M8

sun protection

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

REV Änderungen Datum Name

Datum NameGez.Gepr.Norm.

Maßstab Blatt

Installation HS10 mit Prellschutz 50m

23.01.2012 ew

1

A3

.

.

D:\Products\TARGETS\DetectionSystems\HS10\Mechanik\HS10\Kleinkaliber\Installation HS10 mit Prellschutz 50m.idw

.

1:5

Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS

35 *

209

557

470

85 * 300 * 85 *

269

185 6

51.5

191

450min forsun protection

392

50-100

45.5

4

30 * 410 *

470

30 *

310

115

*42

** = Montage, Alle Löcher für Schrauben M8

sun protection

1

1

2

2

3

3

4

4

5

5

6

6

A A

B B

C C

D D

REV Änderungen Datum Name

Datum NameGez.Gepr.Norm.

Maßstab Blatt

Installation HS10 mit Prellschutz 50m

23.01.2012 ew

1

A3

.

.

D:\Products\TARGETS\DetectionSystems\HS10\Mechanik\HS10\Kleinkaliber\Installation HS10 mit Prellschutz 50m.idw

.

1:5

Im Langhag 1 CH - 8307 EffretikonTel: +41 52 354 60 60 Fax: +41 52 354 60 66SIUS

35 *

209

557

470

85 * 300 * 85 *

269

185 6

51.5

191

450min forsun protection

392

50-100

45.5

4

30 * 410 *

470

30 *

310

115

*42

*

* = Montage, Alle Löcher für Schrauben M8

sun protection

Sun protection

At least 450 for sun protection

* = Installation, all holes for screws M8

3 positions target elevator for HS10. Mobile or fixed installation pos-sible. The target is attached to the electronic target elevator from the back.

Detailed information: installation manual ATE10 for HS10«B-INBE-ATE10V1/2-de»

Page 13: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

13

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Example of an installation – small bore rifle 50m

Installation on a beam

Targ

et H

S10

(SIU

S)

Line

1Li

ne 2

Line

10

Line

11

Tube

Ø 8

0mm

(con

stru

ctio

n si

de)

pref

erab

ly w

ith

inse

rted

taut

wire

Targ

e lin

e

Pow

er s

uppl

y fo

r 10

line

s (S

IUS

)

Pow

er s

ocke

t for

pow

er s

uppl

y(c

onst

ruct

ion

side

)

Page 14: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

14

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Example of an installation (overview) – small bore rifle 50m

Installation on a beam

Installation

Target HS10(SIUS)

Tube Ø 100mm to central computer room (construction side) preferably with inserted taut wire

Connection box 300x300x200mm(construction side)

Tube Ø 50mm in ground(construction side) preferably with inserted taut wire

Illumination:Do not use halogen lamps or electric bulbs. Infrared light could interfere with the system.For all outside installations we recommend CFL / gas discharge lamps.

Page 15: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

15

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Installation

Air rifle / air pistol installation 10m and small bore rifle installation 50m

Installation overview for 1–10 lanesThe installation is divided into 3 article groups: article group target line (A), article group for cables and power supply (B) and article group firing line (C). The article group for cables and power supply (B) is designed for 10 lanes maximum. The article groups target line (A) and firing line (C) are needed 1x per lane. The «10 Lane Command Desk» (D) enables the central printing and the display of the connected lanes for the spectators (see SIUS website > Products > «10 Lane Command Desk»).In addition, country-specific power supply cables are required (device to country specific plug = pos. 1).

A1

A2B4

1

A3

A

B

C

Pos. Article no. Pcs. DescriptionA Article group target lineA1 HS10V1 1 Target 10m resp. 50m, incl. LED Illumination, without integrated digital displayA2 KL001-T 1 T-Adapter fem/fem/male LTW IP67A3 KL001-2.0 1 Cable LTW male–fem 2.0mB Article group cables and power supplyB1 NT211V0 1 Power supply for 10 lines 225W with LTW 230VB2 KL013 1 Y power cable for NT211B3 KL001-20.0 1 Cable LTW male–fem 20.0m (for 10m installation)

KL001-65.0 1 Cable LTW male–fem 65.0m (for 50m installation)B4 KL001-R 2 Terminating resistor, red, male LTW IP67C Article group firing lineC1 M951 1 Monitor TFT 10.4“ (26cm) Touchscreen, incl. power supply AAG233, USB connection cable for touchscreen

and protection cover M951AN001.AA253-1.5 1 Connection cable USB 2.0, 1.5m (option if monitor is installed separately from CU951)KV012-1.5-MM 1 Cable extension VGA, 2.0m (option if monitor is installed separately from CU951)

C2 CU951-CLUB 1 Control unit for clubs, schools etc. (ISSF approval phase 1 and 2)CU951-ISSF 1 Control unit with software for ISSF competitions (ISSF approval phase 1, 2 and 3)

C3 KL001-2.0 1 Cable LTW male–fem 2.0mC4 KL001-T 1 T-Adapter fem/fem/male LTW IP67D 10-Lane-Command-Desk (option)D1 TLCD 1 Software 10-Lane-Command-Desk incl. USB-LON-Dongle SNI210-TLCD (blue)D2 1 Windows PC with up-to-date hardware (on request or provided directly by customer)D3 1 Laserprinter (on request or provided by customer)D4 1 Monitor for spectators > TV / beamer in any size (on request or provided directly by customer)

1 Country-specific power supply cable > AA1**

1 2 10

Line 1 Line 2 Line 10

B2B3

C4 C3

C1

1C2

C3

B1

(max 4m)

D1

D2

D3

D4

D

B4

Central PC for data acquisition,display and evaluation

> see brochureLarge installations and components

Page 16: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

16

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Set the lane no. on the target

Bringing into service

Check in advance

– All devices connected according ot the instructions?– Any visible damages on devices or cables?– Voltage of the power supplies set according to the voltage of the electric power supply?

To set the lane number, it is necessary to remove the print out of the target. This has to be done without a connected target holder.

The lane no. is set by turning the arrow on the number plate to the corresponding figure, using a screwdriver. Numbering is made from bottom to top.

A

B

C

D

D = 1-no. settingThe according 1-no. is set.

C = 10-no. settingIf more than 10 targets are connected, the according10-no. can be chosen.Otherwise leave the setting on 0.

B = 100-no. settingIf more than 100 targets are connected, the according100-no. can be chosen.Otherwise leave the setting on 0.

A = Node-Nr. (no. of the target in the same line)Only applicable if in the same line several targets are in use (for example military use). Otherwise leave the setting on 0.

1. Pull out the mechanical interlock button of the print (must be locked again when closing the target).

2. Unclip by raising and pulling.

3. Pull out the whole print.

Bringing into service

Page 17: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

17

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Closing the target

After closing the target, check that there are no cables in the firing line.

Configuration of control unit at firing point

The control unit (for example SA941 or PC/Laptop with LON-dongle and SIUSLANE software) can be configured. See > http://sius.com > Downloads

TIPWith a PC and LON-Organizer software installed the functionability of all installed components in the network can be checked.Software LON-Organizer > http://sius.com > Downloads

Examples of setting the lane no. on the target

Setting lane no. 8:

Setting lane no. 163:

Connecting the electricity networkConnect all devices to the electricity network.

After proper installation and connecting the target to the electricity network the operating lamp WD blinks in a interval of 1/2 second.

Control of the operating lamp

Control of detection system transmitters

The two transmitters of the measuring system need to glow.

1 Remote control for target with digital display2 Power supply for target with digital display resp. stand-alone version with SIUSLANE software3 Plug-in for target print4 LTW-network-connection (Cabeling according to draft on page 15) 5 Target elevator

Connections and laying of cables1 2 3 4 5

Laying of cables and cable relief.

oder

Bringing into service

Page 18: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

18

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

Replacing a worn out target front mask

Maintenance and function test

Cleaning from dust and dirt

– remove all dust and dirt with a vacuum cleaner– clean the detection system (transmitter and receiver) with a soft damp cloth (do not use any cleaning agent)

The target front mask should be replaced:– if its circular shape is not visible anymore – if it is in such a bad condition that the optic of the target is affected – if there are holes, which are bigger than the used projectile

For the 10m target the front mask can be replaced from inside.

For the 50m target the front mask can be replaced outside directly on the reinforced front frame.

Replacement of rubber sheet

Rubber sheet LS10A042inside the target holder (50m target)

> If defective/torned replace immediately

Large holes can permit sunlight to shine into the back of the target. Bad bullet traps can throw back debris.

Both can generate errors in the detection system.

Repair / Replacement of rubber membrane

Mounting of rubber sheet

Maintenance and function control

Art. no. HS10A026Rubber membrane inside target (50m target)(used for the acoustic measurement)

4.1 If the rubber membrane is frayed in the center, the defects parts should be cut out (max. Ø 50mm).

Page 19: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

19

B-INWA- HS10-en – 09/17

Electronic scoring systemsHS10

HYBRIDSCORE®

Update of the software

The software for the control unit can be updated with the "LON-Organizer" software installed on a PC.

TIPAfter each manipulation of the target / system restart the equipment.

5.3 Control of optical detection system Hold the finger shortly in the detection system and check, if the two transmitters are blinking. If not > check for dirt and clean.

5.4 Control of acoustical detection system Tapping each of the five sound transducers. The corresponding light (MIC1 – 5) should be blinking.

Function check5.1 Is the operating lamp WD blinking? If not > check power supply and cables.

5.2 Communication control

– press service-pin button – the red TX-lamp should blink – at the same time the green RX-lamp should blink on neighbour target

Maintenance and function control

4.2 Holes outside of the center (max. Ø 50mm),should not be bigger than the used projectile.Otherwise the rubber membrane must be replaced.

Installation of rubber membrane inside target: position of punched hole = bottom of target.

Page 20: HS10 HYBRIDSCORE · Electronic scoring systems HYBRIDSCORE® Table of contents Installation Assembly of the target – airguns 10m 2–3 Assembly of the target – small bore rifle

20

B-INWA- HS10-en – 09/17

HS10Electronic scoring systems HYBRIDSCORE®

SIUS worldwideThere are SIUS representatives all around the globe.

Find your local SIUS sales partner here:

www.sius.com > contact