Top Banner
HEAT EXCHANGER Z.I. les Plenesses - Rue du Progrès 16 - B-4821 DISON - BELGIUM T : +32 (0)87 39 49 30 - F : +32 (0)87 39 49 31 - [email protected] - www.btnsa.com
8

HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

Jun 20, 2018

Download

Documents

builien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

HEA

T EX

CH

ANG

ER

Z.I. les Plenesses - Rue du Progrès 16 - B-4821 DISON - BELGIUMT : +32 (0)87 39 49 30 - F : +32 (0)87 39 49 31 - [email protected] - www.btnsa.com

Page 2: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

HEAT EXCHANGER COPPER/ALUMINIUM

Page 3: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

MANUFACTURING

Archived product documentation since 1990

Efficient after-sale service High performance production workshop

Page 4: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

GEOMETRYH

EAT

EXC

HAN

GER

MATERIALS:Frame: galvanized steel, stainless steel, aluminium

Header: steel, copper, stainless steelFins: copper, aluminium, coated fins, AlMg (only 1/2" and thickness 0,2 mm)

FINSFins type: corrugated or flatTube spacing: 37,5 x 32,48 mm FIN THICKNESS• 0,15 mm for fin spacing 1,8 to 4 mm• 0,2 mm for fin spacing 2,1 to 4 mm• 0,4 mm for fin spacing 3 to 6 mm• 0,1 mm for fin spacing 1,8 to 3 mm (copper) TUBESStandard: copper Ø 12,7 (1/2”) – thickness 0,35 mm

Tubes 1/2"

FINSFins type: corrugatedTube spacing: 50 x 43,3 mm

FIN THICKNESS• 0,15 mm for fin spacing 1,8 to 3 mm• 0,2 mm for fin spacing 2,1 to 4 mm• 0,4 mm for fin spacing 3 to 6 mm• 0,1 mm for fin spacing 1,8 to 3 mm (copper) TUBESStandard: copper Ø 15,87 (5/8”) – thickness 0,4 mmOption: thickness: 0,75 and 0,89 mm

Tubes 5/8"

12,5

37,5

21,65 43,3

37,5

5012

,5

9,38

28,1

2

16,24 32,48

28,1

237

,59,3

8

Corrugated fins

Flat fins

Page 5: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

PRODUCTS

Evaporator/Condenser (also for heat pump)

COPPER/COPPER COPPER/ALU PRECOATED

COPPER/ALUMINIUM with Heresite coating HEAT PIPE

High efficiency Twin Coils (up to 80%)

Page 6: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…
Page 7: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

TECHNICAL PROGRAM

Change-Over and Evaporator / Condenser for heat pumpHeat recovery

Standard Heat exchanger

Heat recovery with input Heat pipe

HEA

T EX

CH

ANG

ER

Page 8: HEAT EXCHANGER - BTNSA · Tubes 1/2" FINS Fins type: corrugated Tube spacing: 50 x 43,3 mm ... Standard Heat exchanger Heat recovery with input Heat pipe HEAT EXCHANGER…

BGB

F

NL P

I

L

DDISON

Air side : G = left - D = rightS, Z for horizontal coils

Diameter of header (Outlet)Diameter of header (Inlet)

Number of InletsFin spacing (ex. : 25 = 2.5 mm)

Number of rowsNumber of Tubes by Row (NTR) Tube 5/8’’ : finned height = NTR x 50 mm Tube 1/2’’ : finned height = NTR x 37.5 mm

Finned length

Fluids : E = Water - G = Glycolized Water - F = Evaporating or Condensing Refrigerant - V = SteamFins material : A = Aluminium – C = Copper – F = Steel – I = Stainless Steel

Tubes material : C = Copper – F = Steel – I = Stainless SteelUse : C = Heating – R = Cooling

Type of coil : B = Coil 5/8’’ for air handling unit - X = Coil 1/2’’ for air handling unitG = Coil 5/8’’ for ducts - Y = Coil 1/2’’ for ducts - T = Heatpipe - S = Coil without frameH = High Efficiency Twin Coils 1/2” - I = High Efficiency Twin Coils 5/8”

B C C A E 1850 T024 2 F30 E012 DN50 DN50 G

EXPLANATION OF THE CODE

Z.I. les PlenessesRue du Progrès 16B-4821 DISONBELGIUMT : +32 (0)87 39 49 30F : +32 (0)87 39 49 [email protected]

la m

aiso

n du

Gra

phis

me