Top Banner
• The IAQ Insulation TM for air ducts • Made with Microban ® antimicrobial protection • Cost-effective with or without PSA • Reduces HVAC noise AP Armaflex ® Gray Duct Liner/Wrap Duct Liner For factory application or retrofit. Fiber free, mold resistant. SUBMITTAL FOR GREENER BUILDINGS
4

Gray Duct Liner/Wrap - armacell.comNA... · AP Armaflex Gray Duct Liner/Wrap is engineered for pinned, fabricated factory application in accordance with SMACNA requirements and, as

Aug 19, 2019

Download

Documents

vuongdien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gray Duct Liner/Wrap - armacell.comNA... · AP Armaflex Gray Duct Liner/Wrap is engineered for pinned, fabricated factory application in accordance with SMACNA requirements and, as

•TheIAQInsulationTMforairducts•MadewithMicroban® antimicrobialprotection•Cost-effectivewithorwithoutPSA•ReducesHVACnoise

AP Armaflex®

Gray Duct Liner/Wrap

Duct Liner

For factory application or retrofit. Fiber free, mold resistant.

SUBMITTAL

FOR GREENER BUILDINGS

Page 2: Gray Duct Liner/Wrap - armacell.comNA... · AP Armaflex Gray Duct Liner/Wrap is engineered for pinned, fabricated factory application in accordance with SMACNA requirements and, as

AP Armaflex Gray Duct Liner/Wrapisengineeredforpinned,fabricatedfactoryapplicationinaccordancewithSMACNArequirementsand,asawraponexistingducts.Availableinarangeofwidthsincluding59˝and60˝,withorwithoutPSA. •Practical: Developedespeciallyforthesheetmetal

industry,andaneffectiveretrofitalternativeforinsulationcontractors

•Mold Resistant: MadewithMicrobanantimicrobialproduct protection •Indoor Air Quality: Fiber-free,formaldehyde-free,low

VOC’s,non-particulating •Plenum rated:Safeforinstitutionalairducts,meetsNFPA standards •Noise blocking and vibration dampening

Description

AP Armaflex Gray Duct Liner / Wrapisaflexibleelastomericthermalinsulation.Itsclosed-cellstructurepreventscondensationandmoisturewicking,andmakesitanefficientinsulation.ItismanufacturedwithouttheuseofCFCs,HFCsorHCFCs.TheMicroban®antimicrobialprotectionisregisteredbytheEnvironmentalProtectionAgencyforuseinairducts(EPAReg.No.1258-840-42182).ItisaddedduringmanufacturingtoprovideanextralevelofdefensetothenaturalmoldresistanceofAPArmaflex.

APArmaflexGrayDuctLineriseffectiveforreducingHVACnoise.

Itissuppliedinrolls46˝,47˝,48˝,56-1/4˝,59˝and60˝wide,in1˝or1/2˝(specialorder)thicknesses.WithPSA,itisintendedtobepinnedduringfactoryapplicationinaccordancewithSMACNArequirements.WithoutPSA,nopinningisrequiredifadheredwithArmaflex520Adhesive.

Approvals and Compliance

APArmaflexGrayDuctLiner/WrapmeetsrequirementsofNFPA90Aand90BforDuctCoveringsandLinings,andUL181forMoldGrowth.Approvedforuseinreturnairplenums,conformstoASTMC1534requirementsandwithstandstemperaturesof250˚F.

AllAPArmaflexinsulationmeetsrequirementsofInternationalEnergyConservationCode(IECC)andASHRAEforR-Value4.2at1˝thickness.R-Value2.2at1/2˝thickness.

Uses and Applications

APArmaflexDuctLiners/Wrapsareidealforairhandlingsystems,VAVunits,ductsandotherairsystemcomponentsrequiringcondensationcontrol,resistancetomoisture,damageorheatgain.Theyalsoreducenoisegeneratedbyfansandairmovementaswellastherattleorpoppingofsheetmetalairducts.Thegraylinerisespeciallyeffectivefactory-appliedforenduseareaslikeschools,hospitals,hotels,commercialandpublicbuildings.

Duct Liner www.armacell.comFor the latest document, please refer to our website.

Duct Liner/WrapInstallation

Note: Must be installed according to “Installation of Armaflex Insulations” publication (000-005).

Whenairstreamvelocitiesexceed4,000FPM(20.3m/second),metalnosingshouldbeappliedtoeveryleadingedge.Nosingmaybeformedonductsorbechanneledorzee-attachedbyscrews,rivetsorwelds.

APArmaflexGrayDuctLinerislight-tackself-adhering,whichprovidesconvenienttemporaryadhesionpriortopinning.ItisalsoavailablespecialorderwithoutPSA.Inthatcase,ifinstalledusingArmaflex520Adhesive,nopinningisrequired. (Please see “Wrap” illustration and caption.)ThefollowinginstructionsapplytothePSAproduct,thereforethemosttypicalapplication:

Theproductmustbesecuredwithmetalfasteners,eitherimpactdrivenorweld-secured,whichmustcompressthelinersufficientlytoholditinplace.

ALLARMACELLFACILITIESINNORTHAMERICAAREISO9001:2000CERTIFIED.

SecurewithmetalfastenersinaccordancewithSMACNApublication,“HVACDuctConstructionStandards,MetalandFlexible”.

Thetemperatureoftheairandoftheinsulationshouldbebetween40°F(4°C)and100°F(38°C)atthetimeofinstallation.

Preparesurfacebycleaningwithappropriatecleaner.Measure.

Cutwithsharpknife.Peelbackenoughreleaselinertostart.

Squareoffsheetalonganedgeorcorner.Pressthesheettothesurfacetakingcarenottotrapanyair.

ReachbehindtheArmaflexsheetandpeellinerbackwhilepressingthesheettothesurface.

Pressfirmly.Buttjointsrequiretheuseofcompressionjointstopreventthepossibleopeningofseams.

BOTTOM

TOP

SIDESIDE

Asretrofitoron-siteductwrap,usingArmaflex520Adhesiveonallsurfacestobejoined:1.CutBOTTOMpiece,tothesamewidthasduct.2.CutSIDEpieces,measuredflushwithducttopandextendingdownoveredgesofbottompiece.3.InstallTOPpiecelast,cuttoextendoversidepieces.Ifoutdoors,applytwocoatsArmaflexWBFinish.

ALCOHOL

1/4"

Page 3: Gray Duct Liner/Wrap - armacell.comNA... · AP Armaflex Gray Duct Liner/Wrap is engineered for pinned, fabricated factory application in accordance with SMACNA requirements and, as

Duct Liner www.armacell.com

For the latest document, please refer to our website.

Features Benefits

Closed cell structure

Resistsmoisture,nonwickingReducedwaterpresenceinsystemandinsulationNondustingLongerlifeWon’tcontributetoairqualityproblems

Made with Microban antimicrobial product protection

ResistsmoldontheinsulationEPAregisteredforuseinairductinsulation

Noise reducing, higher-density material

MoreproductiveworkenvironmentReducesorblocksHVACnoiseHelpspreventmetalductvibration,soundtransfer

Smooth surface that reduces dirt and debris accumulation

InhibitsamplificationofbiologicalcontaminantsBasisforcontinuingsystemhygiene

Elastomeric foam

FiberfreeResistanttoincidentaldamageNospecialtools;nodustmaskrequiredduringfabricationandinstallation

Inherent vapor retarder RequiresnomasticsCompetitivetotalinstalledcost

Notes

➀AP/ArmaflexGrayDuctLiner hasaflamespreadindexof lessthan25andasmoke developedindexoflessthan 50forallthicknessesuptoand including1˝(25mm)when testedaccordingtoASTME84 andCANULCS-102.Numerical flammabilityratingsalonemaynot definetheperformanceof productsunderactualfire conditions.Theyareprovided onlyforuseintheselectionof productstomeetlimitsspecified.

➁Withstandstemperatureof250°F (121°C)whentestedaccordingto ASTMC411.“TestMethodfor SurfacePerformanceofHigh- TemperatureInsulations”.Atthis temperature,AP/Armaflex GrayDuctLinerinsulationshows noevidenceofflaming,glowing, smoldering,delamination,melting orinsulationcollapse.Although thisinsulationwillwithstand hightemperatures,continuous usetemperatureshouldbelimited to180°F(82°C).

➂Attemperaturesbelow-20°F(-29°C) elastomericinsulationstartsto becomelessflexible.However,this characteristicdoesnotaffect thermalefficiencyorwatervapor permeabilityofArmaflexinsulation.

➃ReferenceOnly

Physical Properties

AP/Armaflex Gray Duct Liner / WrapFor applications that require pinning in accordance with SMACNA or retrofit “wrap” applications.

Specifications Values Test Method

Thermal Conductivity, Btu • in./h • ft2 • °F (W/mK) 75°F mean temperature (24°C) 90°F mean temperature (32°C)

0.25 (0.036) 0.256 (0.037) ASTM C 177 or C 518

Water Vapor Permeability, Perm-inch. [Kg/(s•m•Pa)] 0.05 [0.725 x 10-13] ASTM E 96, Procedure A

Flame Spread and Smoke Developed Index ➀Through 1˝ (25 mm) 25/50

ASTM E 84 CAN ULC S-102

Mold Growth Fungi Resistance Bacterial Resistance

UL181 ASTM G21/C1338 ASTM G22

Meets requirements Meets requirements Meets requirements

Water Absorption, % by Volume 0.2% ASTM C 209

Upper Use Limit ➁ 180˚F (82˚C)

Lower Use Limit ➂ -297˚F (-183˚C)

Erosion Resistance Does not break away, flake off or show evidence or delamination at velocities of 10,000 ft/min ASTM C 1071

Corrosiveness Noncorrosive ASTM C 665

Odor Emissions No objectionable odors ASTM C 665

Density, Typical Range ➃ 3.0 – 6.0 lbs/ft ASTM D 1622 ASTM D 1667

Thickness 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz NRC†

Nom. 1˝ (25mm) 0.05 0.17 0.080 0.44 0.60 0.49 0.50

Sound Absorption Coefficients at Frequency

Thickness STC Class

Nom. 1/2˝ (13 mm) 25

Nom. 1˝ (25mm) 25

Sound Transmission Class (STC) Sizes

Roll Width 46 ,̋ 47̋ , 48̋ , 56-1/4̋ , 59̋ and 60̋

Wall Thickness 1̋ and 1/2̋ (special order)

Page 4: Gray Duct Liner/Wrap - armacell.comNA... · AP Armaflex Gray Duct Liner/Wrap is engineered for pinned, fabricated factory application in accordance with SMACNA requirements and, as

021GS 001 06 08 NA NA © 2008 Armacell LLC Printed in United States of America

ARMACELL LLC TEL: 1 800 866-5638 FAX: 919 304-3847 [email protected] www.armacell.com 7600 Oakwood Street Extension • Mebane, NC 27302

Armacell provides this information as a technical service. To the extent the information is derived from sources other than Armacell, Armacell is substantially, if not wholly, rely-ing upon the other source(s) to provide accurate information. Information provided as a result of Armacell’s own technical analysis and testing is accurate to the extent of our knowledge and ability, as of date of printing, using effective standardized methods and procedures. Each user of these products, or information, should perform their own tests to determine the safety, fitness and suitability of the products, or combination of products, for any foreseeable purposes, applications and uses by the user and by any third party to which the user may convey the products. Since Armacell cannot control the end use of this product, Armacell does not guarantee that the user will obtain the same results as published in this document. The data and information are provided as a technical service and are subject to change without notice.

MICROBAN is a registered trademark of Microban Products Company.