Page 1
3TRACTION CABLES
GKW-RW/S 300/500V Thin Wall Multicore
º Applications
Multi core power and control cable designed for protected, fixed installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and alternating voltage technology, especially converter technology.
º Standard
• BS 6853 -Ia• DIN 5510-2 1-4• NFF 16-101 F0
º Construction
• Conductors: Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.• Insulation: Electron beam crosslinkable LSZH compound.• Sheath: Electron beam crosslinkable LSZH compound.
º Electrical Characteristics at 20℃ Nominal Conductor Cross Section mm² 0.5 0.75 1 1.5 2.5Maximum Conductor Resistance Ω/km 40.1 26.7 20.0 13.7 8.21Voltage Rating KV 0.3/0.5
º Mechanical and Thermal Properties
Minimum Bending Radius: 4xOD (Static); 6xOD (Flexing) Temperature Range: -60℃ ~+120℃ (Static); -40℃ ~+90℃ (Flexing)Short Circuit Temperature: +280℃
Stranded Tinned Copper Conductor
Electron Beam Crosslinkable LSZH Sheath
Electron Beam Crosslinkable LSZH Insulation
Caledonian Railway CablesTRACTION CABLES
[email protected] @railway-cables.com
Page 2
www.addison-cables.com 4
º Dimensions and Weight
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
2×0.5 16/0.20 0.18 4.5 293×0.5 16/0.20 0.18 4.6 364×0.5 16/0.20 0.18 5.0 445×0.5 16/0.20 0.18 5.4 526×0.5 16/0.20 0.18 5.9 597×0.5 16/0.20 0.18 6.4 718×0.5 16/0.20 0.18 6.8 819×0.5 16/0.20 0.18 7.1 81
10×0.5 16/0.20 0.18 7.3 8812×0.5 16/0.20 0.18 7.5 10114×0.5 16/0.20 0.18 7.9 11516×0.5 16/0.20 0.18 8.3 12818×0.5 16/0.20 0.18 8.8 14419×0.5 16/0.20 0.18 8.8 14820×0.5 16/0.20 0.18 9.3 16124×0.5 16/0.20 0.18 10.2 18127×0.5 16/0.20 0.18 10.6 20036×0.5 16/0.20 0.18 11.9 26148×0.5 16/0.20 0.18 13.5 3372×0.75 24/0.20 0.18 4.8 373×0.75 24/0.20 0.18 5.1 484×0.75 24/0.20 0.18 5.6 585×0.75 24/0.20 0.18 6.1 696×0.75 24/0.20 0.18 6.7 817×0.75 24/0.20 0.18 7.1 938×0.75 24/0.20 0.18 7.7 1089×0.75 24/0.20 0.18 8.1 108
10×0.75 24/0.20 0.18 8.3 11812×0.75 24/0.20 0.18 8.6 13714×0.75 24/0.20 0.18 9.0 15616×0.75 24/0.20 0.18 9.5 17518×0.75 24/0.20 0.18 10.0 19819×0.75 24/0.20 0.18 10.1 20220×0.75 24/0.20 0.18 10.5 21924×0.75 24/0.20 0.18 11.7 24827×0.75 24/0.20 0.18 12.2 27536×0.75 24/0.20 0.18 13.7 36248×0.75 24/0.20 0.18 15.5 4682×1.0 32/0.20 0.18 5.2 453×1.0 32/0.20 0.18 5.5 594×1.0 32/0.20 0.18 6.2 73
Caledonian Railway CablesTRACTION CABLES
[email protected] @railway-cables.com
Page 3
5TRACTION CABLES
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
5×1.0 32/0.20 0.18 6.7 876×1.0 32/0.20 0.18 7.3 1027×1.0 32/0.20 0.18 7.9 1198×1.0 32/0.20 0.18 8.4 1359×1.0 32/0.20 0.18 8.9 137
10×1.0 32/0.20 0.18 9.1 15012×1.0 32/0.20 0.18 9.4 17414×1.0 32/0.20 0.18 9.9 19916×1.0 32/0.20 0.18 10.4 22318×1.0 32/0.20 0.18 11.0 25419×1.0 32/0.20 0.18 11.1 25920×1.0 32/0.20 0.18 11.7 28224×1.0 32/0.20 0.18 12.9 31927×1.0 32/0.20 0.18 13.4 35436×1.0 32/0.20 0.18 15.1 46748×1.0 32/0.20 0.18 17.2 6072×1.5 30/0.25 0.22 6.0 593×1.5 30/0.25 0.22 6.4 814×1.5 30/0.25 0.22 7.1 995×1.5 30/0.25 0.22 7.7 1236×1.5 30/0.25 0.22 8.5 1437×1.5 30/0.25 0.22 9.1 1638×1.5 30/0.25 0.22 9.8 1889×1.5 30/0.25 0.22 10.5 189
10×1.5 30/0.25 0.22 10.7 21512×1.5 30/0.25 0.22 11.1 24414×1.5 30/0.25 0.22 11.7 27916×1.5 30/0.25 0.22 12.3 32618×1.5 30/0.25 0.22 13.0 35819×1.5 30/0.25 0.22 13.1 36620×1.5 30/0.25 0.22 13.7 39624×1.5 30/0.25 0.22 15.3 45027×1.5 30/0.25 0.22 15.9 50136×1.5 30/0.25 0.22 17.9 66337×1.5 30/0.25 0.22 18.5 71948×1.5 30/0.25 0.22 20.5 8642×2.5 50/0.25 0.28 7.1 893×2.5 50/0.25 0.28 7.4 1174×2.5 50/0.25 0.28 8.3 1505×2.5 50/0.25 0.28 9.1 1826×2.5 50/0.25 0.28 9.9 2097×2.5 50/0.25 0.28 10.8 2468×2.5 50/0.25 0.28 11.7 2859×2.5 50/0.25 0.28 12.5 286
Caledonian Railway CablesTRACTION CABLES
[email protected] @railway-cables.com
Page 4
www.addison-cables.com 6
No. of cores& Nominal Conductor Cross Sectional
AreaNo.×mm²
Number and Nominal Diameter
of StrandsNo/mm
Nominal Insulation Thickness
mm
Nominal Overall Diameter
mmNominal Weight
kg/km
10×2.5 50/0.25 0.28 12.7 31812×2.5 50/0.25 0.28 13.1 37214×2.5 50/0.25 0.28 13.9 42816×2.5 50/0.25 0.28 14.7 48318×2.5 50/0.25 0.28 15.2 53819×2.5 50/0.25 0.28 15.5 56520×2.5 50/0.25 0.28 16.4 61224×2.5 50/0.25 0.28 18.3 69527×2.5 50/0.25 0.28 18.9 77636×2.5 50/0.25 0.28 21.3 103048×2.5 50/0.25 0.28 24.5 1347
Soldering HeatResistant
Highly Flexible
UV Resistant
NF C32-070-2.2(C1)IEC 60332-3/EN50266
Fire Retardant
IRM 903 FuelOil Resistant
Zero
Zero HalogenIEC 60754-1/NF C20-454
EN 50267-2-1
Impact Resistant AbrasionResistant
Corona Resistant
Flame RetardantNF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1EN 50267-2-2/NF C32-074IEC 60754-2/NF C20-453
Low Corrosivity Low ToxicityLow Smoke EmissionIEC 61034/NFC20-902EN 50268/NF C32-073
IRM 902 MineralOil Resistant
Ozone Resistant Acid and AlkaliResistant
Cold Resistant Low TemperatureResistant
Caledonian Railway CablesTRACTION CABLES