Order Codes Intro A B C D E F G X Record Plus A.4 FD frame Breaking capacities 2, 3 and 4 pole types Single pole types Protection Accessories Type FD160 S 36 E 25 C 18 N 50 N 25 H 80 H 50 L 150 Icu 400/415V AC in kA eff. Icu 230/240V AC in kA eff. Trip Unit FD160 (2, 3 and 4 pole) Trip Unit FD160 (1 pole) Rated Current (A) 3 7 12.5 16 20 25 30 32 40 50 63 80 100 125 160 Rated Current (A) - - - 16 20 25 - 32 40 50 63 80 100 125 160 LTM - - - C,E C,E C,E - C,E C,E C,E C,E C,E C,E C,E C,E LTM - - - N,H N,H N,H - N,H N,H N,H N,H N,H N,H N,H N,H LTMD - - - S,N,H S,N,H S,N,H,L - S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L S,N,H,L GTM - - - - - N,H - N,H N,H N,H N,H N,H N,H N,H N,H Mag Break™ N,H N,H N,H - N,H,L - N,H,L - - N,H,L - N,H,L N,H,L - - Number of poles/ protected poles (trips) 2 pole 2 trips 3 pole 3 trips 4 pole 3 trips 4 pole 4 trips 4 pole 3.5 trips (N = 50%) (2) Number of poles/ protected poles (trips) 1 pole 1 trip - C,E - C,E - - N,H N S,N,H,L N,H,L S,N,H,L - N,H,L - N,H N,H N,H - N,H - N,H,L N,H,L - - - Auxiliary contact left mounted (NO or NC) Auxiliary contact right mounted (NO or NC) Bell Alarm trip unit (NO or NC) Bell Alarm mechanism (CO) (1) Shunt or Undervoltage release Operators Rotary Handle Electrical Operator RCD, side or bottom mounted (1) (Insert indicates Bell alarm contact mounting) Plug-in system (1) Not applicable for some FDC and FDE types. LTM Line thermal magnetic protection LTMD Selective thermal magnetic protection GTM Generator thermal magnetic protection Mag Break™ Magnetic Only protection Y Non Automatic or switch (not mentioned in tables) 1 2 3 4 5 6 7 8
8
Embed
GE - Record Plus - MCCB - selective and current limiting pole 1 trip 1 pole 1 trip(2) 240V 50kA FDH (1) Neutral on the left. If neutral on the right is needed, please contact us. (2)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
2 pole 2 trips3 pole 3 trips4 pole 3 trips4 pole 4 trips
4 pole 3.5 trips
(N = 50%)(2)
Number of poles/ protected
poles (trips)
1 pole 1 trip-C,E
-C,E
--
N,HNS,N,H,LN,H,L
S,N,H,L-
N,H,L
-N,HN,HN,H
-N,H
-N,H,LN,H,L
---
Auxiliary contact left mounted
(NO or NC)
Auxiliary contact right mounted
(NO or NC)
Bell Alarm trip unit (NO or NC)
Bell Alarm mechanism (CO)(1)
Shunt or Undervoltage release
Operators
Rotary Handle
Electrical Operator
RCD, side or bottom mounted(1)
(Insert indicates Bell alarm contact
mounting)
Plug-in system
(1) Not applicable for some FDC and FDE types.
LTMLine thermal magnetic protectionLTMDSelective thermal magnetic protectionGTMGenerator thermal magnetic protectionMag Break™Magnetic Only protectionYNon Automatic or switch (not mentioned in tables)
1
2
3456
7
8
FD160 - Complete circuit breakerLine Thermal Magnetic LTM (fixed settings calibrated at 40°C)
Line Thermal Magnetic LTM (adjustable thermals calibrated at 40°C)
One code covers: a standard fixed front connection breaker + DIN-rail mounting kit + toggle elongator + breaker finishing covers + fixation hardware
One code covers: a standard fixed front connection breaker + DIN-rail mounting kit + toggle elongator + breaker finishing covers + fixation hardware
4 pole 3 trips(1)3 pole 3 trips 4 pole 3.5 trips (N = 50%)(1)4 pole 4 trips(1)
3 pole 3 trips 4 pole 4 trips(1)
2 pole 2 trips
1 pole 1 trip(2)1 pole 1 trip(2)
240V 50kA FDH
(1) Neutral on the left. If neutral on the right is needed, please contact us.(2) Fixation hardware not suitable for mounting of one individual single pole breaker (see page A.10)
FD160 - Complete circuit breakerSelective Thermal Magnetic LTMD (Settable thermals calibrated at 40°C)
Line Thermal Magnetic LTM (fixed settings calibrated at 40°C)
Selective Thermal Magnetic LTMD (Settable thermals calibrated at 40°C)
FD160 - Complete circuit breakerGenerator Thermal Magnetic GTM (Settable thermals calibrated at 40°C)
Motor Protection (Mag Break™ Magnetic Only Breakers (Rated at 40°C)
Complete Non-Automatic Circuit Breaker (Switch rated at 40°C)
Ronis keylock 1104B nr. BC 1027(2) (c)Ronis keylock 1104B nr. BC 1053(2) (c)Ronis keylock 1104B nr. BC 2932(2) (c)Ronis keylock 1104B nr. BC 2911(2) (c)Ronis keylock 1104B nr. BC 2936(2) (c)Ronis keylock 1104B nr. BC 2940(2) (c)Ronis lock with random key(2) (c)Profalux lock with random key(2) (d)
Voltage 220/440V AC (a)Voltage 400/690V AC (a)
Voltage 220/440V AC (b)
Voltage 220/440V ACVoltage 400/690V AC
Bell Alarm RCD device
Cat. no.
FAS10RFAS10LFABAT10FABAT10
-
FASHTBFASHTDFASHTFFASHTHFASHTJFASHTNFASHTU
-
FDEMFFFDEMFHFDEMFJFDEMFNFDEMF8
FD1BREFD1BPE
FDNRF/5FDNRFV/5
--
----
FDNREFDNR4
FA1BR1FA1BR2FA1BR3FA1BR4FA1BR5FA1BR6FA1BRHFA1BPH
FDQDS3M/6FDQDS3H/6
FDQDI3M/6
FDQDB3M/6FDQDB3H/6
FABAT10
Ref. no.
430837430834430818430818
-
430840430843430846435118430849430852430855
-
430929430932430935430938430920
430877430876
436478436479
--
----
430986430971
430088430089430504430505430506430507430068430813
431095431090
431086
431078431076
430818
Cat. no.
FAS01RFAS01LFABAT01FABAT01
-
FAUVRBFAUVRDFAUVRFFAUVRHFAUVRJFAUVRNFAUVR8FAUVRU
FDNRC/5FDNRCV/5FDNRY/5FDNRYV/5
----
FDQDS4M/6FDQDS4H/6
FDQDI4M/6
FDQDB4M/6FDQDB4H/6
FABAT 01
Ref. no.
430831430828430815430815
-
431960430861430864435120430867430870436472430873
436474436475436487436488
----
431103431101
431088
431084431080
430815
Cat. no.
----
FDBAM11
----
FAUVDN--
----
FDNRD/5FDNRDV/5FDNRZ/5FDNRZV/5
Ref. no.
----
430880
----
430858--
----
436476436477436489436490
Normally closedNormally open Changeover
UndervoltageShunt
Only for use with panel or door mounted type Not for use with panel or door mounted type
One code covers an RCD with: DIN-rail mounting kit and multidirectional supply kit
One code covers an RCD with: DIN-rail mounting kit and interconnection kit.
One code covers an RCD with: sealable connection cover (cut-out adaptor FDUF)
(1) Not for all FDC and FDE types(2) Key included(3) Add door flange FDFH to allow use of the door interlock options(4) On request 1xNO/1xNC is available.
(5) Not possible on FDC and FDE types with TF and TC trip unit. 100/200V AC rating available on request
Delayed undervoltage
Accessories
Normally closedNormally open
Rotary handle for use through door or cover plate(3)Direct on device Panel or door mounted
(b) (a)
(b)
(a)
(c)
(d)
4 pole3 poleStandard
Side connected only
FD - Internal accessories
Contacts
Releases
FD - Operators Electrical operators
Rotary handles
FD - Residual current devices RCD side mounted(5)
RCD bottom mounted(5)
(below trip unit area)
Ord
er C
odes
Intro
A
B
C
D
E
F
G
X
Record Plus
A.10
Cat. no.
FDDDF3FDDFF3FDDMP3
FDDFQ3FDDMP3
FAPFMFAPF8FAPM8
FAPPS
FAPIP
FDBES3FDBEH3FDBEA3
FDBSS3
FDTCA1316
FDBRC3-
FDBRCS2FDBRCL2
FDJL3
FDJS3
FDJP
FDJB
FDJK
FDUF3
FBF6
Ref. no.
430893430899430905
433489430905
430824430823430826
430827
430825
430887430885430883
430891
433400
430889-
433358433357
430951
430960
430957
430945
430069
430830
883970
Cat. no.
FDDDF4FDDFF4FDDMP4
FDDFQ4FDDMP4
FDBES4FDBEH4FDBEA4
FDBSS4
FDTCA1416
-
FDBRC4
--
FDJL4
FDJS4
FDUF4
-
Ref. no.
430896430902430908
433492430908
430888430886430884
430892
433401
-
430890
--
430954
430963
430832
-
4 pole3 pole
Complete set: Fixed and mobile part with connection and fixation hardwareFixed part: Fixed base with connection and fixation and hardware Mobile part: Mechanism trip device, terminal shields and set of 3 or 4 pole plugs
(1) Plug-in system max. 125A. (2) Only necessary when internal accessories or an electrical operator are used. (3) External box clamps are always delivered with standard extender
(4) Set for equipping the line OR load side of breaker.(5) Supplied with mag. break types.
Complete set for breakerFixed part for breakerMobile part for breaker
Fixed part for breaker and RCDMobile part for breaker and RCD
Complete set 8 poleFixed part 8 poleMobile part 8 pole
10 pole wired Plug and Socket for Plug-in Device
Insertion prevention kit(of ….wrong A rating)
Standard flat type (a)Heightened type (b)Twisted 90° (c)
Pole spacing 35 mm
Cable Cu/Al 95 mm2 (3)
Set 3 pole (2 short, 1 long)Set 4 pole (2 short, 2 long)
Spares, set of 2 short typesSpares, set of 2 long types
Long, set of 2 pcs.
Short, set of 2 pcs.
Phase separators, set of 12 pcs.
Backplate set of 2 pcs. (3 or 4 pole)
Finger protection IPXXB (set of 12 pcs.)(5)
Cut-out adaptor, Breaker + Trip unit
Cut-out filler for cover plate (64 mm), length of 1.2 m