Top Banner
Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option
36

Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Jan 03, 2016

Download

Documents

Shanon Copeland
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Gateway PlazaWilmington, DE

Elizabeth HostutlerStructural Option

Page 2: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Presentation Outline• Project Overview• Depth Study• Breadth Studies

– Mechanical: duct design

– Construction Management: scheduling and cost estimates.

• Cost Analysis• Conclusions

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 3: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

PROJECT INFORMATION

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 4: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Project Information-Key Players• Buccini/Pollin Group• Gilbane• Gensler• Engineers

– Landmark Engineering– Duffield Assoc., Inc.– BALA Consulting Engineers, Inc.– O’Donnell Naccarato & MacIntosh

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 5: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Project Information-Overview• Location: 500 Delaware Ave.• 15 stories + mechanical penthouse

(210’-6”)– 1st level: retail space & lobby.– 14 floors office space for tenant fit-out.

• July 2005-December 2006• $52 million (17% structural system)• 387,000 ft2

• 5-story parking garage in rear• Tinted glass curtain wall façade

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 6: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Project Information: Existing Conditions

• Composite steel framing• Concrete filled steel pile

foundations with pile cap• 6-¼” slab on deck• 30-1/4” floor depth.• Concentrically braced frames.

N

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Service Core

STAIRS STAIRSREST-

ROOMSMECH.ROOM

ELEVATORLOBBY

Page 7: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Project Information: Existing Conditions

N

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

52’-6”x30’-0” and 36’-0”x30’-0” typical bays.

52’-6” x 30’-0” bay

36’-0” x 30’-0” bay

Page 8: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

DEPTH STUDY

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 9: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Post-tensioned Concrete Floor

• Design Objectives:– Preserve long span bays.– Limit floor depth to 24”.

• Feasibility Factors:– Cost– Schedule– Impact on foundations

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 10: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Post-tensioned Concrete Floor

• Design: One-way post-tensioned concrete slab with post-tensioned beams framing along column lines.

• Criteria:– 6000 psi concrete

– 8” thick slab

– 52.5’ long beams: 24”x 36” beams

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 11: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Post-tensioned Concrete Floor

Tendon Layout

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 12: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Post-tensioned Concrete Floor

• Final Design:– Initial jacking force: 1303 k in slab and

1040 k in beams.– (6)-½” dia banded tendons in slab.– Tendons spaced 6’ apart.– 39 tendons in longitude beams.– 20 tendons in latitude beams.

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 13: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Post-tensioned Concrete Floor

• Initial Service Loading

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 14: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Post-tensioned Concrete Floor

• Sustained Service Loading

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 15: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Lateral System

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

• Problems:

– Increased weight impacted seismic.

– Eccentricity created torsion.

– Limiting drift to H/600 = 4.21”

• Solutions:

– Added 1 shearwall between mechanical room and elevator lobby.

– Considered concrete frames to resist lateral load.

– Maximum drift was 3” (H/840).

Page 16: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Lateral System• Shearwalls: 12” thick 4000 psi with #6 @ 14” o.c.

N

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Additional shearwall

Page 17: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Lateral System

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Seismic Loads in east-west direction: 0.9D + 1.0 E

Wind Loads in north-south direction: 1.2D + 1.6W + L + 0.5

Lr

Page 18: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Depth Study-Impact on Foundation• Increase foundation loads by an

average 38%.• Change foundations to end-

bearing caissons.– Minimum size: 3.5’ diameter– Maximum Size: 6.5’ diameter

Concrete Steel

B 2 1107 k 307 k1 1151 k 754 k

C 3.7 98 k 98 k3 957 k 829 k2 2434 k 1796 k1 1597 k 1325 k

K 3.7 98 k 81 k3 992 k 831 k2 2069 k 1490 k1.4 1203 k 943 k

Location

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 19: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

BREADTH STUDIES

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 20: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

MECHANICAL STUDY

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 21: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Mechanical Study

• Check for proper indoor air quality.• Design ductwork.

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 22: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Mechanical Study• Existing system:

– Rooftop cooling tower.

– Heat pump and air conditioning unit in each mechanical room.

– 26”x96” main supply duct on each floor.

• 24”x24” supply and return diffusers.

• Ceiling plenum return.

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 23: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Mechanical Study

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Typical open office floor plan for 6 tenants.

Page 24: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Mechanical Study

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

• Supply diffuser layout with 16’ air throws.

• 650 cfm per diffuser.

Page 25: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Mechanical Study• Supply ducts with return stub ducts.

– Largest: 68”x20”

– Smallest: 10”x10”

Exhaust LouverReturn grill

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 26: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

CONSTRUCTION MANAGEMENT

STUDY

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 27: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Construction Management Study• Schedule Comparison• Cost Comparison• Rough estimate of foundation costs and

comparison.

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 28: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Construction Management Study-Scheduling• Duration: 156 days

– Columns (F/R/P): 2 days• Forming• Tying Reinforcement• Pouring and curing

– Construct/Erect shoring and formwork: 3 days

– Tie reinforcement for slab and beams: 1 day

– Rough-in for MEP: 1 day– Concrete (for each section):

• Pour and finish: 1 day• Cure: 2 days

– Strip formwork & reshore: 2 days– Jack the post-tensioning tendons: 1

day

0

20

40

60

80

100

120

140

160

Duration

Concrete

Steel

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 29: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Construction Management Study-Estimates

Amount Material Labor Equipment Cost

03110-405 Beam formwork 7044 SFCA 0.91 4.05 $63,46603110-420 slab edge forms 479 SFCA 0.48 4.6 $2,432

slab formwork 21910 sf 1.3 2.86 $216,47103210-600 Slab Reinforcing 46.18 tons 800 380 $72,041032230-600 Ungrouted Post-tensioned strand 26350 lb 0.47 0.87 0.02 $58,76103300-220 6000 psi Concrete 687 CY 109 $74,88303310-700 Placing 687 CY 11.5 4.7 $11,129

Total $499,183

03310-240 24"x24" average reinforcing including 4 use forms, concrete, placement, reinforcing

72 CY 370 400 41 $58,392

Total $58,392

B2010-101 12" thick, plain finish, 4000 psi wall including 4 use forms, reinforcing, concrete, placement

3402 sf 6.6 15.35 21.95 $97,127

Total $97,127

Total $654,702Cost/sf $28

Estimate of Post-tensioned Concrete Design for One Typical FloorSlabs System

Columns

Shearwalls

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 30: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Construction Management Study-Estimates

Amount Material Labor Equipment Total Cost05310-300 20 ga. 3-1/4" Metal Deck 23403 SF 1.88 0.34 0.02 $60,38003210-200 6x6 W1.4xW1.4 234 CSF 19.35 17.35 $12,64903300-220 6000 psi concrete 253 CY 81 $20,47803310-700 Placing concrete 253 CY 13.1 5.35 $4,66405120-260 Curb Edging 718 LF 14 4.95 0.33 $17,397

Total $98,171

05120-680 Offices over 15-stories 107 TON 1900 345 109 $251,87805090-840 3/4" dia Shear Studs 27352 0.49 0.67 0.28 $57,713

Total $309,591

05120-680Columns, Beams, and Braces 50 TON 1900 345 109 $117,700

07800-600 Decking 22000 SF 0.62 0.54 0.09 $51,260Beams 17295 SF 0.41 0.45 0.07 $31,650Columns 3506 SF 0.47 0.62 0.1 $8,521Total $91,430

TOTAL $616,892Cost/sf $26

Frames

Fireproofing

Estimate of Composite Steel Design for One Typical Floor

Slabs System

Structural Steel

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 31: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Construction Management Study-Estimates

Amount Material Labor Equipment Cost

A1020-310 4'-0" dia. x 100' 20 Ea 4358 70459 $1,496,3295'-0" dia. x 100' 6 Ea 8064 144990 $918,3246'-0" dia. x 100' 10 Ea 11730 172277 $1,840,069

TOTAL $4,254,722

A1020-130 End Bearing Steel Piles Amount Material Labor Equipment Cost2380 4 pile cluster 5 5625 3325 $44,7502460 6 pile cluster 8 8425 5025 $107,6002480 7 pile cluster 7 9825 5850 $109,7252500 8 pile cluster 5 12600 7525 $100,6252560 12 pile cluster 9 15400 9200 $221,400

03310-240 Pile caps, incl. forms and reinf. 612 108 49 0.31 $96,309TOTAL $680,409

Caissons

Concrete Filled, Drilled Piers

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 32: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Construction Management Study

Total Cost Cost/Floor Cost/sf Duration Foundations

Concrete $ 10,475,227 $ 654,702 $27.98 156 $4,254,722Steel $ 9,870,274 $ 616,892 $ 26.36 140 $680,409

System Comparison

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 33: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

CONCLUSIONS

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 34: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

Conclusions• Post-tensioned system is viable based on cost and

schedule, not on foundations.• Achieved savings of 6.25”/floor=100” total.

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 35: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

AcknowledgementsO’Donnell Naccarato & MacIntosh

Peter Paton, Structural Engineer

GilbaneCraig Hedlund, Construction Manager

Dr. Linda Hanagan

RAM Concept Technical Support

Chad Illig Anthony Lucositic

David J. MelfiJustin MulhollanSteven Puchek

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006

Page 36: Gateway Plaza Wilmington, DE Elizabeth Hostutler Structural Option.

QUESTIONS?

GATEWAY PLAZAWilmington, DE

Elizabeth Hostutler – Structural Option – Spring 2006