Page 1: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate Management

BOMA International®

Module 3: Building Operations I

Heating, Ventilating, and Cooling the Building

®

Page 2: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 2

®

Objectives

List the three components of the HVAC system

List the three tasks of the ventilation system Explain why it is important to balance

outside air and exhaust air pressures, and tell what happens in a commercial building if the pressures are uneven

Trace the flow of air through the duct work distribution system

Page 3: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 3

®

Objectives

Describe how electric reheat coils in a VAV box provide heat

Describe how baseboard heating systems provide heat

Describe the refrigeration cycle Describe the chilled water cycle Describe the condenser water cycle List at least five methods to improve efficiency

of heating and cooling functions

Page 4: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 4

®

HVAC

Heating

Ventilating

Air Conditioning

Page 5: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 5

®

Ventilation

Provides outside air

Removes stale air

Filters

Page 6: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 6

®

Ventilation

Outside Air DamperPhoto courtesy of PM 101

Page 7: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 7

®

Ventilation

Variable Frequency DrivePhoto courtesy of Transwestern

Page 8: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 8

®

Ventilation

It’s a continuum

No outside air 100% outside air

Maximum energy efficiency Minimum energy efficiency

Minimum IAQ Maximum IAQ

Page 9: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 9

®

Ventilation

Free cooling

Using outside air to condition the space

Page 10: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 10

®

Ventilation

Exhaust

Removing odors and carbon dioxide

Page 11: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 11

®

Ventilation

Separate exhaust for kitchens and

restrooms

Page 12: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 12

®

Ventilation

Ensure restaurant tenants clean their exhaust system regularly

Page 13: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 13

®

Ventilation

Plenum Return

Ducted Return

Page 14: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 14

®

Ventilation

Partition Walls

Demising Walls

Fire Dampers

Protection

Page 15: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 15

®

Ventilation

Photos courtesy of Transwestern

Page 16: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 16

®

Humidity

ASHRAE recommends 50% relative humidity

(range of 30-60%)

Dehumidification

Humidification (rare)

Page 17: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 17

®

Pressure

The Goal:

Pressure In = Pressure Out

Page 18: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 18

®

Pressure

Over Pressurization More air is brought in than is exhausted

Inoperable exhaust fan, incorrect VFD settings

Front doors will not close properly

People feel pressure (like on airplane)

HVAC becomes inefficient

Page 19: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 19

®

Pressure

Under Pressurization More air exhausted than brought in

Inoperable outside air fan, incorrect VFD settings

Front doors hard to open

HVAC becomes inefficient

Façade will leak

Page 20: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 20

®

Filtration

Filters remove dust, debris, insects, and other contaminants

Pleated filters v. fiberglass filters

HEPA filters

Charcoal filters for odors

Changed routinely

Page 21: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 21

®

Air Distribution

Air Handler

Trunk Line

Branch Line

VAV Boxes/Terminal Units

Supply Air Diffusers

Page 22: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 22

®

Air Distribution - Zoning

Areas of the building operate differently from one another

Zones determined by:

Function/Use

Location

Page 23: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 23

®

Air Distribution

Air Handling Unit (AHU) or Air Handler

Page 24: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 24

®

Air Distribution

VAV Box – controlled by a thermostat

Page 25: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 25

®

Air Distribution

Supply Air Diffuser

Page 26: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 26

®

Air Distribution

Trunk and Branch Ducts

VAV Boxes and Supply Air Diffusers

Page 27: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 27

®

Thermostat Types

Pneumatic

Direct Digital Control (DDC)

Set point temperature

Impossible to please everyone

Location

Page 28: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 28

®

Thermostat

ASHRAE-recommended set points

71o F for heating (68-75o F)

76o F for cooling (73-79o F)

Balance tenant comfort with energy efficiency

Page 29: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 29

®

Thermal Layering

Temperature is measured in the middle 1/3 (On top of the desk)

Bottom 1/3 is coolest (space heaters)

Heat Rises – Top 1/3 is warmest

Page 30: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 30

®

Space Heaters

Page 31: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 31

®

Heating

Involves adding heat

Page 32: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 32

®

Heating

Fuel Sources

Electricity

Natural Gas

Heating Oil

Page 33: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 33

®

Heating

Systems

Central

Local

Page 34: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 34

®

Heating

In most buildings, heating occurs only around perimeter – not in core

Air handler provides cooling to entire building

Electric heaters in perimeter VAV boxes heat perimeter as needed

Page 35: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 35

®

Heating

Baseboard heating

Electric

Hot water or steam

Under floor or sidewalk (radiant)

Interlock

Page 36: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 36

®

Cooling

Involves removing heat

Page 37: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 37

®

Cooling

Just 3 Loops

Refrigerant Loop

Chilled Water Loop

Condenser Water Loop

The loops do not mix!

Page 38: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 38

®

Cooling

The Refrigeration Loop/Cycle

Refrigerant

Compressor

Condenser

Expansion Valve

Page 39: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 39

®

Cooling

Refrigerant

Fluid that absorbs heat

Moves from liquid to gas (add heat) and back to liquid (remove heat) easily

Boiling point is low: 50-60o F

Gas at room temperature

Page 40: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 40

®

Cooling

Compressor

Applies pressure

Changes refrigerant from low pressure gas to a high pressure, super-heated vapor

Page 41: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 41

®

Cooling

Condenser

Rejects heat outside building

Either air cooled or water cooled

Enters as a super-heated vapor

Leaves as a high temperature, high pressure liquid

Page 42: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 42

®

Cooling

Expansion Valve

Sprays liquid into a fine mist

Reduces pressure and cools refrigerant

Page 43: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 43

®

Cooling

Evaporator Transfers heat from building to refrigerant

Heating the refrigerant causes it to boil

Heated refrigerant then passes to compressor and the cycle continues…

Page 44: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 44

®

Cooling

The refrigeration cycle is nothing more than changing the refrigerant from a liquid to a gas and back to

a liquid…over and over again

It’s a closed loop system

Page 45: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 45

®

Cooling

The Refrigeration Cycle

Page 46: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 46

®

Cooling

Heat always moves from

higher to lower

temperature

Page 47: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 47

®

Coils and Bundles

Coils

Transfer heat between air and refrigerant

Bundles

Transfer heat between liquid and refrigerant

Page 48: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 48

®

Coils and Bundles

Photo courtesy of PM 101

Coils

Page 49: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 49

®

Coils and Bundles

Shell and Tube Bundles

Page 50: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 50

®

Moving Heat from Inside to Outside

Chilled Water Loop

Rejects heat from occupied spaces to the refrigerant

Condenser Loop (air-cooled) or Condenser Water Loop (water-cooled)

Rejects heat from the refrigerant to outside of the building

Page 51: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 51

®

Cooling

Chilled Water Loop

Water treatment is critical

Picks up heat in evaporator coil (in AHU) and takes heat to refrigerant loop

Cooler chilled water returns to evaporator coil to start process over again

As heat is removed, cooler air is blown through duct system by the AHU

Page 52: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 52

®

Cooling

Condenser Water Loop (water-cooled)

Water treatment is critical

Picks up heat in refrigerant loop loop and takes heat to heat to cooling tower

Page 53: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 53

®

Cooling

Cooling Tower

Condenser water pipes bathed in cool water sprayed inside cooling tower. Large fans also help transfer heat

Heat is transferred to outside

Cooler condenser water is pumped back inside to start cycle again

Page 54: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 54

®

Cooling

Condenser Loop (air-cooled)

Air is blown over refrigerant loop to reject heat

Page 55: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 55

®

Cooling

Water- or Air-Cooled Systems Chillers

Self-Contained Units (SCUs)

Air-Cooled Systems Rooftop Units (RTUs)

Split System

Heat Pump

Page 56: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 56

®

Cooling

ChillerPhoto courtesy of PM 101

Page 57: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 57

®

Cooling

Self-Contained Unit (SCU)Photos courtesy of PM 101

Page 58: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 58

®

Cooling

Rooftop Unit (RTU)Photo courtesy of Thomas J. Easley

Page 59: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 59

®

Cooling

Split SystemPhoto courtesy of Thomas J. Easley

Page 60: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 60

®

Cooling

Heat Pump

Page 61: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 61

®

Piped Systems

Types

2 Pipe

4 Pipe

Fan coil units

Page 62: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 62

®

Free Cooling

Rejecting heat without using the compressor

Flat plate heat exchanger

Photo courtesy of Transwestern

Page 63: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 63

®

Control Systems

Building Automation System (BAS)

Energy Management System (EMS)

Page 64: Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®

Foundations of Real Estate ManagementModule 3: Building Operations I 64

®

Controlling HVAC Costs Optimize EMS Use free cooling Pay attention to weather Coasting Check temperatures with hand-held

thermostat Control tenant adjustment abilities Aggressive water treatment Keep all components clean