Top Banner
Ft Lauderdale Rehab Demo With SewperCoat August 2010 Chaz Environmental Services, Inc.
14

Fort lauderdale demo manhole (08 2010)

Jan 20, 2015

Download

Technology

Chaz Equipment Environmental Services before and after SewperCoat manhole rehabilitation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Fort lauderdale demo manhole (08 2010)

Ft Lauderdale Rehab Demo

With SewperCoat

August 2010

Chaz Environmental Services, Inc.

Page 2: Fort lauderdale demo manhole (08 2010)

Why SewperCoat?• Rehabilitate existing infrastructure

damaged by H2s biogenic corrosion with a PROVEN product.

• Structural enhancement, corrosion protection and infiltration barrier.

• In need of a product that infiltration and H2S will not “get behind?”.

• SewperCoat is a “3-in-1” product.

Page 3: Fort lauderdale demo manhole (08 2010)

Why SewperCoat?• Desire to protect the structure with a product with a

world wide 70+ year track record.• Added security of a 10 YEAR WARRANTY!• One product provides structural enhancement,

corrosion barrier and infiltration barrier. (3-in-1)

Before After

Page 4: Fort lauderdale demo manhole (08 2010)

FT LAUDERDALE DEMO Manhole

Effects of biogenic corrosion and infiltration

Missing bench and invert

Severe Infiltration

Deteriorated fiberglass

Missing bench

Missing invert

Page 5: Fort lauderdale demo manhole (08 2010)

FT LAUDERDALE DEMO Manhole Infiltration…and this

is in DRY ground conditions!

Page 6: Fort lauderdale demo manhole (08 2010)

SewperCoat Process• We clean with 5000 PSI water blasting.• We remove all & any existing coatings, such as

this 1/2inch thick fiberglass liner.

Page 7: Fort lauderdale demo manhole (08 2010)

• Patch walls and stop all leaks.• Rebuild bench and invert.• We work with live flow or flow-through plugs.

SewperCoat Process

Page 8: Fort lauderdale demo manhole (08 2010)

FT LAUDERDALE Demo Manhole

Cleaned manhole chimney showing H2S

damage

Debris and fiberglass removed from manhole

Page 9: Fort lauderdale demo manhole (08 2010)

SewperCoat Process

• We apply SewperCoat PG (pumpable grade), 100% Pure Fused Calcium Aluminate aggregate/cement which cures up to

10,000psi within 24 hours.

Page 10: Fort lauderdale demo manhole (08 2010)

SewperCoat Process• Once the desired thickness is spray applied

(minimum 1/2”, but in this case 1-3” overall) we hand trowel the surface.

Page 11: Fort lauderdale demo manhole (08 2010)

SewperCoat Process• After troweling we brush the entire interior:

walls, chimney and bench for an aesthetic and signature look.

Page 12: Fort lauderdale demo manhole (08 2010)

Infiltration enters behindthe fiberglass and runs down on to the bench.

Rebuilt bench and channel.

No manhole should be replaced before we look at it!

Page 13: Fort lauderdale demo manhole (08 2010)

No fancy top coats, no epoxies, nothing that can peel off, delaminate or fall off …and there’s NO getting behind it!

…one product does it all!

Page 14: Fort lauderdale demo manhole (08 2010)

FT LAUDERDALE DEMO Manhole finished!