Construction

Pitfalls of Construction.…

Page 2: Fmc agserv pestech

So what do WE need to know?

Australian Standards

Legislation

Measurements

Method of Construction

Service Penetrations

Understanding of Ventilation

What builders leave for US

2

Page 3: Fmc agserv pestech

Currently under review

Page 4: Fmc agserv pestech

4

Currently under review

Page 5: Fmc agserv pestech

Slab on Ground Constructions

The Australian Standard AS 3660.1-2000 Termite management Part 1: New building work specifies that a slab on ground should be designed and constructed either in accordance with AS 2870 or AS 3660.

Section 2: Performance Criteria

2.3.1 Concrete slabs as termite barriers

• A concrete slab or footing used as a termite barrier shall

(a) be designed and constructed so that any cracks passing through the slab or footing do not exceed 1 mm in width through the depth of the slab;

(b) have all interfaces between the penetrations and slab or footing provided with a termite barrier system integrated with the slab; and

(c) have all joints, except for tied footing slab construction joints, provided with a termite barrier system integrated with the slab.

Page 6: Fmc agserv pestech

Legislation

• Queensland amendment to the BCA.

• BCA amendments only apply to building classes 1 & 10

• AS2870 -2011 Residential Slabs and Footings

• Soil Classification – A, S, M, H, E, P

− Slightly reactive to Extremely reactive.

6

Page 7: Fmc agserv pestech

‘The Measurements’

Standard Height Brick – 230mm x 110mm x 75mm

Besser Block – 390mm x 190mm x 190mm

Mortar Joint – 10mm-12mm

Render – 8mm-10mm

Bagging – Up to 3mm

7

Page 8: Fmc agserv pestech

Timber Detail

8

Page 9: Fmc agserv pestech

Figures from HIA

Page 10: Fmc agserv pestech

The Beginning……..

10

Page 11: Fmc agserv pestech

‘The Exposed Edge Slab’

11

Page 12: Fmc agserv pestech

‘The Exposed Edge Slab’…..gone!

12

Page 13: Fmc agserv pestech

‘The Exposed Edge Slab’

13

Page 14: Fmc agserv pestech

‘The Monolithic Slab’

14

Page 15: Fmc agserv pestech

Monolithic Slab Construction

Page 16: Fmc agserv pestech

‘The Infill Slab’

16

Page 17: Fmc agserv pestech

‘The Infill Slab’

17

Page 18: Fmc agserv pestech

‘The Waffle Pod’

18

Page 19: Fmc agserv pestech

‘The Waffle Pod’

19

Page 20: Fmc agserv pestech

‘The Inslab Water Tank’

• Inslab water tanks have been developed to cater for new houses constructed on a concrete slab.

• They provide architects, designers and builders with a unique water storage solution, especially where space is limited.

• Inslab water tanks conform to BCA AS2870-1996

20

Page 21: Fmc agserv pestech

‘The Inslab Water Tank’

21

Page 22: Fmc agserv pestech

22

Page 23: Fmc agserv pestech

‘The ServicePenetration’

23

Page 24: Fmc agserv pestech

‘The Service Penetration’

24

Page 25: Fmc agserv pestech

25

‘The Service Penetration’

Page 26: Fmc agserv pestech

26

‘The Open End’

Page 27: Fmc agserv pestech

‘The Service Penetration’

27

Page 28: Fmc agserv pestech

‘The Open End’

28

Page 29: Fmc agserv pestech

‘The Open End’

29

Page 30: Fmc agserv pestech

‘The Service Penetration’

30

Page 31: Fmc agserv pestech

‘The Shower Recess‘

31

Page 32: Fmc agserv pestech

‘The Shower Mess’

32

Page 33: Fmc agserv pestech

‘The Pier’

33

Page 34: Fmc agserv pestech

Piers

34

Page 35: Fmc agserv pestech

‘The Pier’

35

Page 36: Fmc agserv pestech

Ventilation

Sub-floor ventilation is often a forgotten part of termite management.

The BCA (Vol. 2) requires the sub-floor between a suspended floor and the ground to be ventilated.

AS3600 specifies ventilation to be minimum of 8,400 mm squared nett ventilation/Lm

This minimises sub-floor moisture which helps to prevent timber decay, and creates an environment that discourages termite attack.

To be effective, acceptable sub-floor construction must:

• Be free of building debris and vegetation

• Provide cross ventilation,

• Contain no dead air spaces

• Be graded to prevent ponding and be above the external ground level

• Have evenly spaced openings

36

Page 37: Fmc agserv pestech

Minimum Ground Clearance

Page 38: Fmc agserv pestech

Ventilation(cont)

38

• 230mm x 150mm• Terracotta 6,200 – Veta 11,200 – Galvanised

Metal11,700

Page 39: Fmc agserv pestech

Ventilation(cont) House only 6 months old poor ventilation and

termite damage

39

Page 40: Fmc agserv pestech

‘The Good’

40

Page 41: Fmc agserv pestech

‘The Good’

41

Page 42: Fmc agserv pestech

‘The Bad’Retaining wall tinsel

42

Page 43: Fmc agserv pestech

‘The Bad’

43

Page 44: Fmc agserv pestech

‘The Bad’

44

Page 45: Fmc agserv pestech

‘The Bad’

45

Page 46: Fmc agserv pestech

‘The Ugly’

46

Page 47: Fmc agserv pestech

‘The Ugly’

47

Page 48: Fmc agserv pestech

‘The Ugly’

48

Page 49: Fmc agserv pestech

Summary

• Understand construction methods

• Always ask for a plan

• Ask customer questions

• Each house is Different

• Never ASSUME

• If in doubt, phone a friend…….

49

Page 50: Fmc agserv pestech

Pestech Promotion 2014

50

=