FEEL A REAL FUN OF THE GAME WITH MANTA TECHNOLOGY USER MANUAL FILL PANEL FPS-3000/FPD-3000 FILL STATION
Feel a real Fun oF the game
with manta technology
uSer manual
Fill Panel FPS-3000/FPD-3000
Fill Station
the following user manual contains information and instructions for the high pressure fill station Fill Panel FPS-3000/FPD-3000
In order to avoid damage and premature wear and tear, all instructions should be followed, and in the recommended order.
The non-observance of these operating instructions or by using the item in a way not described in the manual, will render the warranty invalid.
Our fill station Fill Panel FPS-3000/FPD-3000 is labelled with a renowned product certificate from TÜV Rheinland which proves that our stations conform to required quality norms. The certification body is a leading worldwide service industry in certification and in this field of research. This relevant document confirms the highest standards of manufacture in the Manta company. A requirement for the TÜV certification is the fulfilment of the standards of 2001/95/EC.
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
contents
1. General Information 3
2. Technical Data 3
3. Safety Advice 4
4. Preparation of Work 5
5. Filling the Bottle 5
6. Technical Documentation, Description of Parts. FPS-3000 5
6.1. Casing of the fill station FPS-3000 6
7. Technical Documentation, Description of Parts FPD-3000 9
7.1. Casing of the fill station FPD-3000 10
7.2. Lever valve 13
7.3. Filling hose 15
7.4. Pneumatic installation set-up 16
8. Storage 16
9. Guarantee 16
10. Service card 17
USER MANUAL
Fill Panel FPS-3000/FPD-3000air Fill Station
2USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
1. general information
Purpose:
The air fill station FPS-3000/FPD-3000 is used for filling paintball bottles with compressed air with a pressure of up to 300 Bar/4500 PSI.
Description:
The construction of the fill station is compact and simple, which ensures you are able to use it comfortably. The station has neither protruding parts nor sharp edges, on which the user could injure himself. All materials used are weather proof and mechanically strong. The air fill station allows for uncomplicated use, without additional cost and can be used in all environments. The hoses used are elastic and do not kink. They allow you for an easy connection to a paintball tank without any effort, tools or shutting off the air supply. The appliance is equipped with a large, reliable pressure gauge, which shows the current operational pressure.
3
2. technical Data
Version FPS-3000 FPD-3000
Max. Operating Pressure 300 Bar/4500 PSI 300 Bar/4500 PSI
Weight 3,5 kg 4 kg
Dimensions 250/170/150 mm 320/170/150 mm
Connection Inlet Typical connection HP 5/8” Typical connection HP 5/8”
Outlet • Female quick release coupler with fuse designed to prevent hose whipping at high pressures
• Female quick release coupler with fuse designed to prevent hose whipping at high pressures
• Connection HP 5/8”, possibility of connecting in series to a second fill station
Casing Steel anti-rust cover Steel anti-rust cover
Pressure Indicator Large easy to read pressure gauge
Large easy to read pressure gauge
Installation Table or wall fixing Table or wall fixing
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
4
3. Safety advice
In order to fill the bottles easily and safely, observe the following simple rules:
• Check the registration date before filling the bottle. If the date is passed, an inspection should be carried out by an authorised service department.
• Check the outside of the bottle for damage. To determine there is no damage, an inspection should be carried out by an authorised service department.
• Check that the bottle pressure gauge is functioning properly and it shows the pressure.
• Check the male quick release coupler (fill nipple). If it is defective, change it for a new one.
• Wipe the male quick release coupler (fill nipple) with a clean towel. A small amount of grease can make the connecting and the disconnecting of the female quick release coupler easier.
• Check the female quick release coupler of the fill station. If it is defective, change it for a new one. there muSt Be a FuSe in the Female QuicK releaSe couPler!!!
• Check the filling hose. This should be changed if there is any wear and tear, kinking or visible damage.
• Make sure that the female quick release coupler is properly connected to the fill nipple.
• Check the official maximum pressure of the bottle and fill to that using the fill station.
• the oFFicial maXimum PreSSure in the Bottle ShoulD at no time Be eXceeDeD!!!
Whilst filling, the bottle should be positioned so that the filling hose is not twisted or squashed.
After the automatic valve degassing, detach the bottle from the female quick release coupler.
The following user manual does not contain all the guidelines regarding the safe filling of compressed air bottles. always keep to the actual guidelines and order recommended. Filling a bottle with compressed air can be dangerous. use of the high pressure system in an incorrect manner can lead to injury.
no SerVicing or cleaning worK ShoulD Be carrieD out whilSt the aPPliance iS PreSSuriSeD!
a DeFectiVe Part oF the Fill Station iS only to Be rePlaceD with an original Part By an authoriSeD SerVice DePartment!
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
5
4. Preparation
• In order to ensure a stable working procedure during the filling process, the fill station should be secured with screws or another connector to a table or wall.
• Connect the filling hose by means of a compressed air source (compressor or air tank) by inserting the hose into one of the two 5.8” HP ports. Ensure that the other one remains closed.
• The compressed air may be fed into the fill station through two 5.8” HP ports at the same or through a series connection or more than one fill station.
• By the opening of an appropriate outlet in the air reservoir or in the compressor, the filling station is supplied with compressed air, the pressure gauge in the fill station will show the current operational pressure.
• After following the above steps, the fill station is ready to use.
5. Filling the Bottle
• Connect the bottle by using the female quick release coupler with the filling hose.
• Then open the lever valve of the fill station.
• Wait until the pressure in the bottle has reached the desired level.
• Close the lever valve afterwards, whereby the filling hose is automatically vented.
• Disconnect the female quick release coupler from the bottle.
the manufacturer takes no responsibility for damage which happens by not paying attention to the above instructions!
6. technical Documentation, Description of Parts. FPS-3000
The construction of the fill station FPS-3000 will be outlined in this section. The directory and main components are listed here.
The following basic components of the air fill station are shown in Figure 1: Casing of the filling station with elements of the pneumatic installation (1), lever valve ZD-3500 (2) and filling hose with female quick release coupler (3) for the bottle connection.
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
6
Figure 1: Basic construction of the fill station FPS-3000.
Table 1. Basic construction of the fill station FPS-3000:
No. Part Catalogue-No.1. Casing FPS-30012. Lever valve ZD-35003. Filling hose WP-2000
6.1. Casing of the fill station FPS-3000
Figure 2: Parts of the fill station FPS-3000 with elements of the pneumatic installation.
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Figure 3: Diagram of the Fill Station FPS-3000 Components
7 USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Table 2. Basic construction of the fill station FPS-3000:
No. Part Catalogue-No.1. Housing FPS-30012. Sticker FPD-3002 3. Grip attachment FPD-30034. Grip FPD-30045. Washer FPD-30056. Holder screw FPD-30067. Inlet socket FPD-30078. Washer FPD-30089. Inlet socket nut FPD-300910. Gauge FPD-301011. Pressure gauge connection FPS-300212. Gauge holder FPD-301213. O-ring FPD-301514. Straight connector FPD-301615. “S type” bending tube FPS-300316. Three pin switch FPD-301817. Single bending tube FPS-300418. Clamping ring FPD-302119. Nut FPD-302220. Nut FPS-300521. Caseback FPS-300622. Rubber foot FPD-302923. Foot screw FPD-303024. Washer FPD-303135. Nut FPD-303226. Blind rivet nut FPD-303327. Caseback screw FPD-3034
Figure 3 shows all housing components, interior finishing and the fitting of its components. In Table 2 all of the appliance’s components are listed together with their catalogue numbers.
8USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
7. technical Documentation, Description of Parts. FPD-3000
The construction of the fill station FPD-3000 will be outlined in this section. The directory and main components are listed here.
The following basic components of the air fill station are shown in Figure 1: Casing of the filling station with elements of the pneumatic installation (1), lever valve ZD-3500 (2) and filling hose with female quick release coupler (3) for the bottle connection.
Figure 4: Basic construction of the fill station FPD-3000.
Table 3. Basic construction of the fill station FPD-3000:
No. Part Catalogue-No.1. Casing FPD-30012. Lever valve ZD-35003. Filling hose WP-2000
9 USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Figure 5: Parts of the fill station FPD-3000 with elements of the pneumatic installation.
10
7.1. Casing of the fill station FPD-3000
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Figure 6: Diagram of the Fill Station FPD-3000 Components
11 USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Table 4. Basic construction of the fill station:
No. Part Catalogue-No.1. Housing FPD-30012. Sticker FPD-3002 3. Grip attachment FPD-30034. Grip FPD-30045. Washer FPD-30056. Holder screw FPD-30067. Inlet socket FPD-30078. Washer FPD-30089. Inlet socket nut FPD-300910. Gauge FPD-301011. Pressure gauge connection FPD-301112. Gauge holder FPD-301213. Straight short tube FPD-301314. Three pin switch FPD-301415. O-ring FPD-301516. Straight connector FPD-301617. Straight long tube FPD-301718. Three pin switch FPD-301819. Bending tube FPD-301920. “U type” bending tube FPD-302021. Clamping ring FPD-302122. Nut FPD-302223. Stub pipe PP-100424. O-ring PP-100525. Nut 5.8” PP-100626. O-ring PP-100327. Inlet aperture screw FPD-302728. Caseback FPD-302829. Rubber foot FPD-302930. Foot screw FPD-303031. Washer FPD-303132. Nut FPD-303233. Blind rivet nut FPD-303334. Caseback screw FPD-3034
Figure 6 shows all housing components, interior finishing and the fitting of its components. In Table 4 all of the appliance’s components are listed together with their catalogue numbers.
12USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
7.2. lever valve
Figures 4 and 5 show the construction of the fill station lever valve ZD-3500 and the valve insert WZ-1000. All of the appliance’s components are listed together with their catalogue numbers in Table 3.
Figure 7: Lever Valve ZD-3500 Figure 8: Valve insert WZ-1000.
13 USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Table 5. List of lever valve components ZD-3500 (Figure 7):
No. Part Catalogue-No.1. Valve Body ZD-35012. Filter ZD-35023. Valve Insert WZ-10004. Ram Body ZD-35035. Ram ZD-35046. Lever Spring ZD-35057. Lever ZD-35068. Air Flow Adjuster ZD-35079. Lever Bolt ZD-350810. Lever Boot ZD-350911. Ball knob ZD-351112. Spring Ring ZD-351213. Nut ZD-351314. O-Ring ZD-351415. Hose Seal ZD-351516. O-Ring ZD-3516
14USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Table 6. List of hose parts with female quick release coupler and fuse (Figure 9):
No. Part Catalogue-No.1. Filling hose WP-20012. Hose grip WP-10023. Washer WP-10034. O-Ring ZD-35145. Hose Seal ZD-35156. O-Ring ZD-35167. O-Ring SZ-10028. Fuse SZ-10089. Fuse Spring SZ-100910. Quick Release Coupler SZ-1000
Figure 9: Filling hose with female quick release coupler and fuse
2
3
7
7
8
5
6
7.3. Filling hose
15 USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
Figure 10: Filling hose with female quick release coupler and fuse
7.4 Pneumatic installation set-up
8. Storage
During storage, the appliance and especially the lever valve and filling hoses should be protected against mechanical damage.
9. guarantee
The fill station is guaranteed for 24 months by the manufacturer. Inspection or maintenance work by unauthorised persons, as well as usage of spare parts not obtained from the manufacturer, will render the guarantee invalid.
Pressure gauge
Connection HP .5.8” with plug
Lever valveZD-3500
Three pin switch
Three pin switch
Connection HP 5.8”
Female quick release coupler
16USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
10. Service card
Date Description Sign
17 USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
warranty termS anD conDitionS
1. MANTA WARRANTS THAT THE PRODUCT WILL BE FREE FROM MANUFACTURING DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USE FOR A PERIOD OF 24 MONTHS FROM THE DATE OF THE ORIGINAL PURCHASE.
2. THIS WARRANTY IS VALID ONLY FOR PRODUCTS THAT ARE PURCHASED NEW AND UNUSED.
3. THE WARRANTY ONLY APPLIES WHERE A DEFECT HAS ARISEN AS A RESULT OF FAULTY MANUFACTURE.
4. REPLACEABLE PARTS SUCH AS 0-RINGS AND QUICK COUPLINGS ARE NOT COVERED BY THE WARRANTY.
5. THE WARRANTY DOES NOT APPLY TO THE FOLLOWING CIRCUMSTANCES:
A) IMPROPER USAGE OR STORAGE OF THE PRODUCT
B) FAULTS CAUSED BY SHOCK OR FALL, REPAIR OR REPLACEMENT OF PARTS BY UNAUTHORIZED PERSONNEL
C) CONNECTION OF OTHER FITTINGS AND ACCESSORIES TO THE PRODUCT WHICH WERE NOT APPROVED BY THE MANUFACTURER
PLEASE RETAIN THIS WARRANTY CARD AND YOUR INVOICE OR PROOF OF PURCHASE FOR FUTURE
REFERENCE. THEY MUST BE PRESENTED IN ORDER TO MAKE A CLAIM.
Dealer'S StamPDealer'S name
ProDuct warranty carD
USER MANUAL / FPS-3000 / FPD-3000 / © 2018 MANTA / All rights reserved.
PRODUCT NAME
MODEL
SERIAL NUMBER
PURCHASE DATE
PURCHASER'S NAME
ADDRESS
ZSn manta
Poland/Polska, 45-054 Opole, ul. Grunwaldzka 38A
tel./fax: +48 (077) 454 79 18 tel.: +48 606 968 555