Slope 1:50 168 196 1 96 Sliding door at Entrance of Builing povided , In accordance with TGD L CHS Column, holidng external canopy in place, bolted on base plate Canopy glass 24mm fixed on with bolts Steel beam/outridge allowing glass o be fixed to and providing shelter Aluminium pressed flashing , fixed to curtain box allowing rain to be drained off Drain pipe Sliding door head detail automatic sensor openings Propriatry drainage channel, external treshold detail Sprandel panel Curtain walling box Structural screed 75mm to Engineers specification PI Rigid Ins thermal conductivity: 0.025W/mK DPM/Radon barrier Hollowcore floor 200mm CHS Column supporting curtain walling boxes Intermideate beam/truss supporing lateral loads Bracket fixing tying curtain walling box to CHS column CHS Column supporting curtain walling boxes Intermideate beam/truss supporing lateral loads Bracket fixing tying curtain walling box to CHS column BASE plate column connection Rain wate gutter Scale LECTURER Drawn by Date Project number Institute of Technology Carlow BSc. in Architectural Technology Year 3 2015-2016 BSc in Architectural Technology Year 3: 2015 - 2016 1 : 5 19/04/2016 18:10:02 External Canopy & Entrance Project Number 3 Carlow Primary Health Care Centre 22/04/2016 Xhevdet Haliti Dan O'Sullivan, Noel Dunne, Mark Duffy A127 1 : 5 External enterance Treshold & Enterance G.F Detail 1 3D - External entrance & canopy 2 1 : 5 Key Plan @ Enterance & Canopy 3 D C 9