Top Banner
HiPath Pro Advanced Digital Pathology THE NEW Every Diagnosis Counts
7

Every Diagnosis Counts - spectral imaging

Jan 17, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Every Diagnosis Counts - spectral imaging

HiPath ProAdvanced Digital Pathology

THE NEW

EveryDiagnosisCounts

Page 2: Every Diagnosis Counts - spectral imaging

1 2 3 4The Ultimate Digital Pathology Flow

Quantitative results in support of conclusive diagnosis

Welcome to your optimized workflow:

or

Flexible panel display of multiple slides with unique annotations and statistics

TEST RESULTS# Cells:Positives:Intensity:Allred:H Score:M Score:

1804132.4%1.7554.79.1

Score100

50

0 0 1 2 3

%#

ANALYSIS RESULTS

All regionsRegions 1

View & Mark Match Analyze Reportfor quantitative resultsregion of interest

with IHC panelyour reference slide scores and snapshots

View&Mark Match Analyze Report Complete!

Full Name: Date Reported:

Date of Birth: Referring Physician:

Patient ID: Tissue Type :

Date Collected: Patient Gender:

Jane Doe

12/11/1967

Female

010203

11/10/2019 12:18:15 PM

Case: DemoCase

Reference RangesPositive negative

ER ≥ 1 < 1

PR ≥ 1 < 1

P53 ≥ 1 < 1

Favorable Borderline Unfavorable

Ki-67 < 10 ≥ 10 - ≤ 20 > 20

Normal Expression Borderline Overexpression

Her2/neu < 1.5 ≥ 1.5 - < 2.5 ≥ 2.5 - 5.0

Case Results

Comments

Stain Images Results6

7 Counted cells: 17276# Cells: 17276Score 0: 0.0% (1)Score 1: 2.9% (498)Score 2: 58.3% (10064)Score 3: 38.9% (6713)M Score: 39.3TPS: 100.0%

8 Counted cells: 20682# Cells: 20682Positives: 79.5%Intensity: 2.6Allred: 8H Score: 205.2M Score: 34.2

11 Counted cells: 10685# Cells: 10685Positives: 80.9%Intensity: 2.8Allred: 8H Score: 225.8M Score: 37.6

12 Counted cells: 18037# Cells: 18037Positives: 32.4%Intensity: 1.7Allred: 5H Score: 54.6M Score: 9.1

Page 1 of 1Monday, February 24, 2020Report Date:

Pathologist Signature

snapshotIHC

H&E H&E ER

PR Ki67

Page 3: Every Diagnosis Counts - spectral imaging

Full breast panel on a single screen, free selection

Examine H&E side by side with PD-L1

Flexible Display Layouts per Clinical TestBenefits to Your Diagnostics:

Exceptional image quality up to 80X digital zoomIntuitive navigation and improved workflowAdvanced visualization tools for in-depth examination Accurate, computer-aided analysis on Whole Slide ImagesAnd so much more

Specialized Algorithms:Integrated tissue detection, tissue matching and cell classification algorithms that can account for what the human eye may not see.

Onscreen Digital Zoom to High Magnification

Image Quality 20X

10X

Page 4: Every Diagnosis Counts - spectral imaging

PD-L1

Ki67*

HER2*

Comprehensive Digital Pathology System

“As an early adopter of the PD-L1 immunostain methodology, our group quickly recognized the inter and intra observer variability in scoring and interpretation of the stain, especially when there is non-uniform staining among tumor regions. We have been very pleased with the added confidence that HiPath Pro provides us in improving accuracy and precision of interpretation.”

Dr. Lija Joseph, Lowell General Hospital

Digital ConnectedLabor efficient

Easy data accessQuantitative analysis

Easy communicationFaster turnaround times

Remote access

Reduced human errorDiagnostic confidenceResults consistency

Standardized

High Throughput Scanning. Capture slides in minutes!

IHC & CISH Quantitative Scoring

FDA cleared for the HiPath IHC Family for HER2, ER, PR and Ki67, on the manual configuration.

AnalyzedOriginal Results

Original Analyzed Results

Original

Original

Analyzed

Analyzed

Results

Results

All nuclear and membrane stainingWide range of tissue samples (e.g. breast, lung, colon, bladder, brain)Vendor neutral

CISH

*

Page 5: Every Diagnosis Counts - spectral imaging

GenASIs AnyWhere™ for Remote Access and TC / PC Model SupportLab Connectivity Anytime, AnywhereReview, analyze and sign off case information from any location via a secured network

Remote access, review and analysis

Pathologist second consulting

Director sign off from any location

GLOBAL ACCESS

Data Management and Connectivity

Modern paperless workflow Secure data management

Central Portal and Database Easily Integrates with Lab LIS

LIS Connectivity

Performance

Security

Data Integrity

HIPAA Compliant

Advanced Reporting 1D/2D Barcode Reader

Full Name: Date Reported:

Date of Birth: Referring Physician:

Patient ID: Tissue Type :

Date Collected: Patient Gender:

Jane Doe

12/11/1967

Female

010203

11/10/2019 12:18:15 PM

Case: DemoCase

Reference RangesPositive negative

ER ≥ 1 < 1

PR ≥ 1 < 1

P53 ≥ 1 < 1

Favorable Borderline Unfavorable

Ki-67 < 10 ≥ 10 - ≤ 20 > 20

Normal Expression Borderline Overexpression

Her2/neu < 1.5 ≥ 1.5 - < 2.5 ≥ 2.5 - 5.0

Case Results

Comments

Stain Images Results6

7 Counted cells: 17276# Cells: 17276Score 0: 0.0% (1)Score 1: 2.9% (498)Score 2: 58.3% (10064)Score 3: 38.9% (6713)M Score: 39.3TPS: 100.0%

8 Counted cells: 20682# Cells: 20682Positives: 79.5%Intensity: 2.6Allred: 8H Score: 205.2M Score: 34.2

11 Counted cells: 10685# Cells: 10685Positives: 80.9%Intensity: 2.8Allred: 8H Score: 225.8M Score: 37.6

12 Counted cells: 18037# Cells: 18037Positives: 32.4%Intensity: 1.7Allred: 5H Score: 54.6M Score: 9.1

Page 1 of 1Monday, February 24, 2020Report Date:

Pathologist Signature

Case Data Management (CDM)

LabLife TM for Lab Management

communicate to customers and management your turnaround times

identify best practices to increase ROI per case and focus improvement efforts

justify investment in additional capital equipment for the lab

compare performance year on year and make data driven decisions

Benchmarks

Optimization

Growth

Annual analysis and review

Telepathology at Its Best!

Cases Slides Cells/Frames

Page 6: Every Diagnosis Counts - spectral imaging

ASI Company Overview Product Portfolio

Applied Spectral Imaging (ASI) is a global leader in biomedical imaging with a comprehensive productportfolio and a global distribution footprint.

Founded in 1993, ASI markets, services and supports its products in nearly 50 countries. With a wide FDA clearance portfolio, you can rest assured that ASI applications have been rigorously tested for compliance and clinical use.

The Company's technology, powered by GenASIs, enables pathology, cytogenetics and research laboratories to provide advanced diagnostics to patients through superior digital diagnostic tools. ASI has a wide portfolio of dedicated solutions for brightfield, fluorescence and spectral imaging and analysis, including HiPath Pro, PathFusion, HiBand, HiFISH, CytoPower and Rainbow.

The Company has offices in the US and Asia and a global network of distribution partners.

Exceptional Imaging & Analysis Solutions for Laboratories

Diverse platforms to accommodate all laboratory needsGlobal Presence

3,500 Systems installed

worldwide

46Third party distribution

partners

50Countries through direct & indirect sales forces

Direct sales

Indirect sales

Cytogenetics Pathology Research

CytoPower PathFusionHiPath ProHiFISHHiBand Rainbow

9-Slide Scanning System 1-Slide Capture System99-Slide Tray Loader

HyperSpectral System Review & Analysis Station AnyWhere Remote Connectivity

ASI Ltd Asia

ASI Inc USA

Page 7: Every Diagnosis Counts - spectral imaging

www.spectral-imaging.com

SCAN ME

North AmericaApplied Spectral Imaging Inc.Tel: +1 760 929 [email protected]

HeadquartersApplied Spectral Imaging Ltd.Tel: +1 817 886 [email protected]

DOC000353 Rev. G

Manual 1 Slide 9 Slides 99 Slides

Microscope Support

BF upright microscopes OLYMPUS BX61 BFOLYMPUS BX63 BFZEISS AxioImager Z2 BF

OLYMPUS BX61 BFOLYMPUS BX63 BFZEISS AxioImager Z2 BF

Objectives

Olympus4x/0.16NA20x/0.5NA40x/0.75NA

ZEISS5x/0.16NA20x/0.5NA40x/0.75NA

Olympus4x/0.16NA10x/0.3NA20x/0.5NA

ZEISS5x/0.16NA10x/0.3NA20x/0.5NA

Olympus4x/0.16NA10x/0.3NA20x/0.5NA

ZEISS5x/0.16NA10x/0.3NA20x/0.5NA

Camera 5MP CMOS Color 5MP CMOS Color 5MP CMOS Color

Slide Capacity 1 slide 9 slides 99+ Slides

Barcode Handheld 1D/2D Handheld 1D/2D Integrated 1D/2D

Dimensions (WxDxH)

According to client microscope

61cm x 69cm x 85cm 100cm x 90cm x 90cm

WeightAccording to client microscope

45 kg 80 kg

System Configurations