1/99 Copyright 2013 FUJITSU LIMITED Edition 98 as of October 17, 2013 Legend Supported( ): ( ) shows the versions of ETERNUS2000 firmware that support each server model. Planned 2: Support is planned. Availability varies depending on the business requirements. Please contact the Storage System Division. N.A.: Not Applicable. Contents Solaris (FC connection) Edition 95 : 2013/1/25 Windows (FC connection) Edition 97:2013/6/3 Linux (FC connection) Edition 98 : 2013/ 10 / 17 VMware (FC connection) Edition 97 : 2013/6/3 SPARC Enterprise Windows 2008R2 (PRIMEQUEST) PRIMEQUEST ESX 5 PRIMEPOWER Windows 2008R2 (PRIMERGY) PRIMERGY (RHEL6) ESX 4 Other_Company_s_server_(x86_x64) Windows 2008R2 (Other Companies' server) PRIMERGY (RHEL5) ESX 3 Solaris (iSCSI connection) Edition 92 : 2012/6/28 Windows 2008(32) (PRIMEQUEST) PRIMERGY (RHEL4) VMware (iSCSI connection) Edition 97 : 2013/6/3 Solaris (SAS connection) Edition 81 : 2011/12/12 Windows 2008(32) (PRIMERGY) PRIMERGY (SuSE) ESX 5 Solaris (FC-FCoE(switch) connection) Edition 88: 2012/5/15 Windows 2008(32) (Other Companies' server) Other Companies' server (RHEL6) ESX 4 HP-UX (FC connection) Edition 95 : 2013/1/25 WINDOWS 2008(64) (PRIMEQUEST) Other Companies' server (RHEL5) ESX 3 HP-UX 11iv3 Windows 2008(64) (PRIMERGY) Other Companies' server (RHEL4) VMware (SAS connection) Edition 97 : 2013/6/3 HP-UX 11iv2 Windows 2008(64) (Other Companies' server) Other Companies' server (SuSE) Egenera (FC connection) Edition 95 : 2013/1/25 HP-UX 11iv1 Windows 2003 (32) Linux (iSCSI connection) Edition 98 : 2013/10/ 17 FC switch Edition 98 : 2013/10/ 17 HP-UX (iSCSI connection) Edition 72 : 2011/3/7 Windows 2003 (64) PRIMEQUEST AIX (FC connection) Edition 95 : 2013/1/25 Windows (iSCSI connection) Edition 97:2013/6/3 PRIMERGY AIX 6.1 Windows 2008R2 Other Companies' server AIX 5.3 Windows 2008 (32/64) Linux (SAS connection) Edition 95 : 2013/1/25 AIX 5.2 Windows 2003 (32/64) PRIMERGY Windows (SAS connection) Edition 95 : 2013/1/25 Other Companies' server Windows 2008R2 Linux (FC-FCoE(switch) connection) Edition 88: 2012/5/15 Windows 2008 (32/64) Linux (iSCSI-FCoE(switch) connection) Edition 91: 2012/6/22 Windows 2003 (32/64) Windows (FCoE connection) Edition 88: 2012/5/15 ETERNUS2000 Server Support matrix Planned 1: Support is scheduled by the indicated date. If the date is month, support is scheduled for the beginning of the month. If the date is nQ, support is scheduled during that quarter.
99
Embed
ETERNUS2000 Server Support Matrix - Fujitsustorage-system.fujitsu.com/global/manual/diskarray/pdf/e2k_support... · ETERNUS2000 Server Support matrix: ... (see Instruction for use
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
1/99 Copyright 2013 FUJITSU LIMITED
Edition 98 as of October 17, 2013
Legend Supported( ): ( ) shows the versions of ETERNUS2000 firmware that support each server model.
Planned 2: Support is planned. Availability varies depending on the business requirements. Please contact the Storage System Division. N.A.: Not Applicable.
ContentsSolaris (FC connection) Edition 95:2013/1/25 Windows (FC connection) Edition 97:2013/6/3 Linux (FC connection) Edition 98:2013/10/17 VMware (FC connection) Edition 97:2013/6/3
SPARC Enterprise Windows 2008R2 (PRIMEQUEST) PRIMEQUEST ESX 5
PRIMEPOWER Windows 2008R2 (PRIMERGY) PRIMERGY (RHEL6) ESX 4
Other_Company_s_server_(x86_x64) Windows 2008R2 (Other Companies' server) PRIMERGY (RHEL5) ESX 3
Solaris (iSCSI connection) Edition 92:2012/6/28 Windows 2008(32) (PRIMEQUEST) PRIMERGY (RHEL4) VMware (iSCSI connection) Edition 97:2013/6/3
Solaris (SAS connection) Edition 81:2011/12/12 Windows 2008(32) (PRIMERGY) PRIMERGY (SuSE) ESX 5
Solaris (FC-FCoE(switch) connection) Edition 88: 2012/5/15 Windows 2008(32) (Other Companies' server) Other Companies' server (RHEL6) ESX 4
HP-UX (FC connection) Edition 95:2013/1/25 WINDOWS 2008(64) (PRIMEQUEST) Other Companies' server (RHEL5) ESX 3
HP-UX 11iv3 Windows 2008(64) (PRIMERGY) Other Companies' server (RHEL4) VMware (SAS connection) Edition 97:2013/6/3
HP-UX 11iv2 Windows 2008(64) (Other Companies' server) Other Companies' server (SuSE) Egenera (FC connection) Edition 95:2013/1/25
HP-UX 11iv1 Windows 2003 (32) Linux (iSCSI connection) Edition 98:2013/10/17 FC switch Edition 98:2013/10/17
HP-UX (iSCSI connection) Edition 72:2011/3/7 Windows 2003 (64) PRIMEQUEST
AIX 5.3 Windows 2008 (32/64) Linux (SAS connection) Edition 95:2013/1/25
AIX 5.2 Windows 2003 (32/64) PRIMERGY
Windows (SAS connection) Edition 95:2013/1/25 Other Companies' server
Windows 2008R2 Linux (FC-FCoE(switch) connection) Edition 88: 2012/5/15
Windows 2008 (32/64) Linux (iSCSI-FCoE(switch) connection) Edition 91: 2012/6/22
Windows 2003 (32/64)
Windows (FCoE connection) Edition 88: 2012/5/15
ETERNUS2000 Server Support matrix
Planned 1: Support is scheduled by the indicated date. If the date is month, support is scheduled for the beginning of the month. If the date is nQ, support is scheduled during that quarter.
2/99 Copyright 2013 FUJITSU LIMITED
- Solaris™ Operating System is described as Solaris OS.- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - GR MultipathDriver is described as "GRMPD", and ETERNUS MultipathDriver is described as "EMPD".- GRMPD has been terminated.- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
Model
100/200
V4.0EMPD 2.0.3
or laterPCL 4.2A00 yes
Supported(V10L10 or later)
When using EMPD2.0.2(for Solaris 9/10 OS driver) or older, please apply patch 914267-05 or later.
V4.0 EMPDOracleRAC11gR2
(see Instruction for use)Yes
Supported(V10L80 or later)
11.2.0(GA) and 11.2.0.2 are supported.
V4.0 VxVM5.0VCS 5.0
(including Oracle RAC)Note 1
YesSupported
(V10L20 or later)When using VxVM 5.0, the maximum number of LUNs is 128.
V4.0 VxVM5.1VCS 5.1
(including Oracle RAC)Note 1
YesSupported
(V10L77 or later)When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
MPxIO SUN Cluster 3.3 Yes Planned 2
MPxIO PCL 4.2A00 YesSupported
(V10L70 or later)Please apply Solaris 10 OS patch 125166-12 or later.Solaris OS 10/08 or later, PTF R08111 or later include the above patch.
MPxIOOracleRAC11gR2
(see Instruction for use)Yes
Supported(V10L80 or later)
11.2.0(GA) and 11.2.0.2 are supported.
VxVM5.0VCS 5.0
(including Oracle RAC)Note 1
YesSupported
(V10L70 or later)Solaris 10 OS 10/08 PTF R09051VERITAS Storage Foundation Standard 5.0 MP1
VxVM5.1VCS 5.1
(including Oracle RAC)Note 1
YesSupported
(V10L77 or later)When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
MPxIO SUN Cluster 3.3 Yes Planned 2
MPxIOOracleRAC11gR2
(see Instruction for use)Yes
Supported(V10L80 or later)
11.2.0(GA) and 11.2.0.2 are supported.
VxVM5.1VCS 5.1
(including Oracle RAC)Note 1
YesSupported
(V10L77 or later)When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
SG-XPCI1FC-EM4-Z/SG-XPCI2FC-EM4-Z,
XSPFC401EU/XSPFC402EU,XAPFC401EU/XAPFC402EU
OS bundled - YesSupported
(V10L10 or later)
SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,
XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU
OS bundled - YesSupported
(V10L10 or later)
SG-XPCI1FC-QF4/SG-XPCI2FC-QF4,
XSPFC401QU/XSPFC402QU,XAPFC401QU/XAPFC402QU
OS bundled - YesSupported
(V10L10 or later)
SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,
XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU
OS bundled - YesSupported
(V10L10 or later)
PCI-Express
LPe11000 OS bundled - YesSupported
(V10L10 or later)
PCI LP11000 OS bundled - YesSupported
(V10L10 or later)
Driver Version
Solaris 10 OS
SwitchBus
Directvia switch
PCI/PCI-Express
PCI-Express
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
PCI-Express
SE0X7F11X/SE0X7F12X
When using Emulex HBA cards, please apply PTF R08021 or patch ID:120222-23.
MPxIO
SE0X7F21XSE0X7F22X
PCI-Express
SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,
XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU
OS bundled
OS bundled
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Notes - The cluster configurations shown in the table are all 2-node cluster system. Please contact the Storage System Division when two or more clusters are connected to one ETERNUS2000 or one cluster consists of more than 2 nodes.
Instruction for useSolaris System OS ConnectedType
SAN bootPath
FailoverCluster SystemHBA
SPARC Enterprise
Solaris FC connection [Edition 95 : January 25, 2013]
(V10L11 or later)When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM). VxVM5.0 needs patch MP1RP5 or later.
Solaris OS 108/07 or later
Directvia switch
PCI-ExpressSG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z
OS bundled MPxIO SUN Cluster 3.2 YesSupported
(V10L70 or later)
When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM (SUN-OEM).VxVM5.0 which needs patch MP1 RP5 or later.Solaris patch 125511-02/125517-03/126047-06 should be applied.
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled Yes Planned 2
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled Yes Planned 2
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
OS bundled Yes Planned 2
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled Yes Planned 2
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled Yes Planned 2
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled Yes Planned 2
SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8
OS bundled Yes Planned 2
SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8
OS bundled Yes Planned 2
SG-XPCI1FC-EM4-Z/SG-XPCI2FC-EM4-Z,
XSPFC401EU/XSPFC402EU,XAPFC401EU/XAPFC402EU
OS bundled YesSupported
(V10L10 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4/SG-XPCI2FC-QF4,
XSPFC401QU/XSPFC402QU,XAPFC401QU/XAPFC402QU
OS bundled YesSupported
(V10L10 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,
XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU
OS bundled YesSupported
(V10L10 or later)
SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,
XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU
OS bundled YesSupported
(V10L10 or later)
Solaris OS10
8/07 or later
Directvia switch
PCI-Express
SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z
XSEFC801QUXSEFC802QU
OS bundled MPxIO SUN Cluster 3.2 YesSupported
(V10L70 or later)
When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM (SUN-OEM).VxVM5.0 which needs patch MP1 RP5 or later.Solaris patch 125511-02/125517-03/126047-06 should be applied.
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L80 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L80 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L80 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z
OS bundled YesSupported
(V10L80 or later)
PCI-bus/PCI-Express
Solaris 10 OS
Direct/via switch
PCI-bus/PCI-
Express
Direct/via switch
Solaris 10 OS
When using SunCluster 3.2, volume management is Veritas5.0-VxVM (SUN-OEM). VxVM5.0 needspatch MP1 RP5 or later.
PCI-Express
SUN Cluster 3.2
Directvia switch
PCI
MPxIO SUN Cluster 3.2Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
MPxIO
Driver Version SwitchPath
FailoverCluster System SAN boot Instruction for use
MPxIOOracleRAC11gR2
(see Instruction for use)11.2.0(GA) and 11.2.0.2 are supported.
MPxIO SUN Cluster 3.3
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
SPARC Enterprise
Solaris 10OS
Directvia switch
Solaris System OS ConnectedType
HBABus
4/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled yesSupported
(V10L11 or later)
Direct/via switch
PCI-Express
LPe12000/LPe12002 6.30gVxVM5.0
MP1No
Supported(V10L51 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
OS bundled YesSupported
(V10L77 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L77 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L77 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled YesSupported
(V10L77 or later)
SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8
OS bundled YesSupported
(V10L77 or later)
SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8
OS bundled YesSupported
(V10L77 or later)
PCI-bus/PCI-
Express
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC6.30g Yes
Supported(V10L77 or later)
PCI-Express
QLE2560/QLE2562 V5.05 YesSupported
(V10L77 or later)
Direct/via switch
Switch
Direct/via switch
PCI/PCI-
Express
When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
VCS 5.1(including Oracle
RAC)Note 1
VxVM 5.1
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Direct/via switch
PCI-bus/PCI-
Express
Direct/via switch
PCI/PCI-
Express
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
VxVM5.0 VCS 5.0(including Oracle
RAC)Note 1
When using VxVM 5.0, the maximum number of LUNs is 128.
MPxIO
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
-
Instruction for use
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
PathFailover
Cluster System
SPARC Enterprise Solaris 10OS
Solaris System OS ConnectedType
SAN bootBus HBA Driver Version
5/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
PW008FC2U V2.2.1/V3.0 YesSupported
(V10L10 or later)
PW008FC3U V2.2.1/V3.0 YesSupported
(V10L10 or later)
PW008FC3 V3.0 update1 YesSupported
(V10L77 or later)
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC6.30g Yes
Supported(V10L77 or later)
PW008FC2U V2.2.1/V3.0 - YesSupported
(V10L10 or later)
PW008FC3U V2.2.1/V3.0 - YesSupported
(V10L10 or later)
Solaris 10 OS Direct/via switch
PW008FC2/PW008FC3 V3.0 update1 EMPDOracleRAC11gR2
(see Instruction for use)Yes
Supported(V10L80 or later)
11.2.0(GA) and 11.2.0.2 are supported.
PW008FC2U V2.2.1/V3.0 YesSupported
(V10L10 or later)
PW008FC3U V2.2.1/V3.0 YesSupported
(V10L10 or later)
PW028FC4U/PW028FC5U,LP10000/LP10000DC
6.11c YesSupported
(V10L11 or later)
Switch
PRIMEPOWER
Solaris 8/9OS
Solaris 8/9/10OS
Directvia switch
Solaris 9 OS Directvia switch
PathFailover
Directvia switch
OS ConnectedType
Bus HBA Driver Version
Directvia switch
PCI-busSolaris 10 OS
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
When using EMPD2.0.2(for Solaris 9/10 OS driver) or older, please apply patch 914267-05 or later.
When using EMPD2.0.2(for Solaris 2.6/7/8/9 OS driver) or older, please apply patch 912651-17.
When using GRMPD1.0.6 or later, please apply patch 912651-17.
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
When using EMPD2.0.2(for Solaris 9/10 OS driver) or older, please apply patch 914267-05 or later.
When using EMPD2.0.2(for Solaris 2.6/7/8/9 OS driver) or older, please apply patch 912651-17.
When using GRMPD1.0.6 or later, please apply patch 912651-17.
PCL 4.2A00
Instruction for use
VxVM5.1
EMPD 2.0.3or later
VCS 5.1(including Oracle RAC)
Note 1
GRMPD1.0.6
(other thanSolaris 10)
/EMPD 2.0.3
or later(Solaris8 isonly 2.0.3)
When using EMPD2.0.2(for Solaris 9/10 OS driver) or older, please apply patch 914267-05 or later.
GRMPD1.0.6
/EMPD 2.0.3
or later(Solaris8 isonly 2.0.3)
-
When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
Cluster System SAN bootSolaris System
6/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
LP10000 V6.11cx2 YesSupported
(V10L10 or later)
LP11000/LPe11000
V6.11cx2 YesSupported
(V10L10 or later)
QLA2340/QLA2342/QLA2460/QLA2462
5.0.3 Yesnote 1
Supported(V10L10 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
SFS 4.4.13 YesSupported
(V10L10 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
SFS 4.4.13 YesSupported
(V10L10 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
SFS 4.4.13 YesSupported
(V10L10 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
SFS 4.4.13 YesSupported
(V10L10 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
SFS 4.4.13 YesSupported
(V10L10 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
SFS 4.4.13 yesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
SFS 4.4.13 YesSupported
(V10L11 or later)
Solaris 9 OS
SUN Fire
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Direct/via switch
MPxIO
When using VxVM 5.0, the maximum number of LUNs is 128.
note1: Please contact to "Inquiries" about SAN-boot with QLogic HBA card.
SAN boot Instruction for use
VCS 5.0(including Oracle RAC)
Note 1
Solaris 8 OS
-
OS SwitchPath
FailoverCluster System
VxVM5.0
VxVM 5.0
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Direct/via switch
PCI-bus/PCI-Express
Bus HBA Driver Version
PCI-bus/PCI-Express
Solaris8/9/10 OS
ConnectedTypeSolaris System
VCS 5.0(including Oracle RAC)
Note 1
MPxIO SUN Cluster 3.2
-
When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.Solaris 9 for Sun Cluster 3.2 should be version "9/05" only
PCI-bus/PCI-Express
Directvia switch
PCI-bus/PCI-Express
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Directvia switch
MPxIO
When using VxVM 5.0, the maximum number of LUNs is 128.
7/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
SFS 4.4.13 YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
SFS 4.4.13 YesSupported
(V10L11 or later)
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC6.30g Yes
Supported(V10L77 or later)
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
6.30g YesSupported
(V10L77 or later)
QLA2340/QLA2342/QLA2460/QLA2462/QLE2460/QLE2462/
QLE2464
V5.05 YesSupported
(V10L77 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
SFS 4.4.15 YesSupported
(V10L77 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
SFS 4.4.15 YesSupported
(V10L77 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
SFS 4.4.15 YesSupported
(V10L77 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
SFS 4.4.15 YesSupported
(V10L77 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
SFS 4.4.15 YesSupported
(V10L77 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
SFS 4.4.15 YesSupported
(V10L77 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled Yes Planned 2
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled Yes Planned 2
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
OS bundled Yes Planned 2
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled Yes Planned 2
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled Yes Planned 2
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled Yes Planned 2
SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8
OS bundled Yes Planned 2
SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8
OS bundled Yes Planned 2
SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,
XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU
OS bundled YesSupported
(V10L10 or later)
SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,
XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU
OS bundled YesSupported
(V10L10 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L10 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L10 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L10 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L10 or later)
Solaris 9 OS
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Directvia switch
SUN Fire
Solaris 10 OS
Direct/via switch
Solaris System OS ConnectedType
Bus SAN bootSwitch Instruction for useCluster System
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Driver VersionPath
FailoverHBA
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
SUN Cluster 3.3
VCS 5.0(including Oracle RAC)
Note 1
MPxIO
PCI-bus
MPxIO
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
SUN Cluster 3.2When using SunCluster 3.2, volume management maybe either SVM or Veritas5.0-VxVM (SUN-OEM).VxVM5.0 needs patch MP1 RP5 or later.
PCI-Express
VxVM5.0
Direct/via switch
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
VxVM 5.1VCS 5.1
(including Oracle RAC)Note 1
PCI-bus/PCI-
Express
When using VxVM 5.0, the maximum number of LUNs is 128.
When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
PCI-bus/PCI-Express
Direct/via switch
PCI-bus/PCI-Express
8/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,
XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,
XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L80 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L80 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L80 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-EM8-ZSG-XPCIE2FC-EM8-Z
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-QF8-ZSG-XPCIE2FC-QF8-Z
OS bundled YesSupported
(V10L80 or later)
SG-XPCIE1FC-EM4/SG-XPCIE2FC-EM4,
XSEFC401AU/XSEFC402AU,XAEFC401AU/XAEFC402AU
OS bundled YesSupported
(V10L11 or later)
SG-XPCIE1FC-QF4/SG-XPCIE2FC-QF4,
XSEFC401QU/XSEFC402QU,XAEFC401QU/XAEFC402QU
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-EM2/SG-XPCI2FC-EM2
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L11 or later)
SG-XPCI1FC-QF2/SG-XPCI1FC-QL2
OS bundled YesSupported
(V10L11 or later)
Direct/via switch
PCI-Express LPe12000/LPe12002 6.30gVxVM5.0
MP1No
Supported(V10L51 or later)
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC6.30g Yes
Supported(V10L77 or later)
QLE2560/QLE2562 V5.05 YesSupported
(V10L77 or later)
SG-XPCIE1FC-EM4SG-XPCIE2FC-EM4
OS bundled YesSupported
(V10L77 or later)
SG-XPCI1FC-EM4-ZSG-XPCI2FC-EM4-Z
OS bundled YesSupported
(V10L77 or later)
SG-XPCI1FC-QF4SG-XPCI2FC-QF4
OS bundled YesSupported
(V10L77 or later)
SG-XPCIE1FC-QF4SG-XPCIE2FC-QF4
OS bundled YesSupported
(V10L77 or later)
SG-XPCIE1FC-EM8SG-XPCIE2FC-EM8
OS bundled YesSupported
(V10L77 or later)
SG-XPCIE1FC-QF8SG-XPCIE2FC-QF8
OS bundled YesSupported
(V10L77 or later)
Bus HBASolaris System OS
SUN Fire Solaris 10 OS
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
Direct/via switch
PCI-bus/PCI-Express
VCS 5.0(including Oracle RAC)
Note 1
PCI-Express
ConnectedType
Driver Version
PCI-bus/PCI-Express
Direct/via switch
Direct/via switch
MPxIO
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
PCI-bus
Direct/via switch
PCI-Express
VxVM5.0
-
PathFailover
PCI-bus
SAN boot Instruction for useCluster System
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
11.2.0(GA) and 11.2.0.2 are supported.
VCS 5.1(including Oracle RAC)
Note 1
MPxIO
Switch
VxVM 5.1
OracleRAC11gR2(see Instruction for use)
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
When using VxVM 5.0, the maximum number of LUNs is 128.
9/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
x86/x64Solaris 10 OS
Direct/via switch
PCI-bus
SG-XPCI1/2FC-EM4SG-XPCIE1/2FC-EM4SG-XPCI1/2FC-QF4
SG-PCIE1/2FC-EM8-ZSG-PCIE1/2FC-EM8LP11000/LP11002
LPe11000/LPe11002QLA2460/QLA2462
OS bundled
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
MPxIO - NoSupported
(V10L10 or later)
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Other Companies'Servers (x86/x64)
Cluster System SAN bootSolaris System Driver Version SwitchPath
FailoverInstruction for useOS Connected
TypeBus HBA
10/99 Copyright 2013 FUJITSU LIMITED
iSCSI native connectionModel
100/200
Direct /via switch
On board LAN OS bundled MPxIO ー NoSupported
(V10L80 or later)
Direct /via switch
SE5X7GD2G OS bundled MPxIO ー NoSupported
(V10L80 or later)
Direct /via switch
SE1X7HE3G OS bundled MPxIO ー NoSupported
(V10L80 or later)
Direct /via switch
SE5X7F22G/SE5X7F32G
OS bundled MPxIO ー NoSupported
(V10L80 or later)
Direct /via switch
On board LAN of servers below
T1000/T2000/T5120/T5220/T5140/T5240/
T5440/M3000/M4000/M5000/
M8000/M9000
OS bundled MPxIO - No Supported(V10L73 or later)
via switch SE0X7GD1F / SE0X7GD2F 3.0 / 4.0 MPxIO - No Supported(V10L73 or later)
via switch SE0X7GQ1F / SE0X7GQ2F 3.0 / 4.0 MPxIO - No Supported(V10L73 or later)
via switch SE0X7HE1F 1.0 MPxIO - No Supported(V10L73 or later)
via switch SESX7XA1F OS bundled MPxIO - No Supported(V10L73 or later)
Direct /via switch X7280A OS bundled MPxIO - No Supported
(V10L73 or later)
Direct /via switch X4447A OS bundled MPxIO - No Supported
(V10L73 or later)
via switch X1027A OS bundled MPxIO - No Supported(V10L73 or later)
Direct /via switch
SE5X7GD2G OS bundled MPxIO - NoSupported
(V10L80 or later)
Direct /via switch
SE1X7HE3G OS bundled MPxIO - NoSupported
(V10L80 or later)
Direct /via switch
SE5X7F22G/SE5X7F32G
OS bundled MPxIO - NoSupported
(V10L80 or later)
Direct /via switch X7280A OS bundled MPxIO - No Supported
(V10L73 or later)
Direct /via switch X4447A OS bundled MPxIO - No Supported
(V10L73 or later)
via switch X1027A OS bundled MPxIO - No Supported(V10L73 or later)
Direct /via switch X4446-A OS bundled MPxIO - No Supported
(V10L79 or later)
Direct /via switch
Intel Pro/1000PTIntel Pro/1000MT
OS bundled MPxIO - No Supported(V10L79 or later)
Connectiontype
Driver version
- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers.Notes
- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
Please apply the following patch- 143645-16 or later
Solaris iSCSI connection [Edition 92 : June 28, 2012]
HBA Path Failover iSCSI Boot Instruction for usesSolarissystem
Cluster System
Solaris 10 OS10/09 or later
Solaris 11 OS
Please apply the following patch- 143645-16 or later
Please apply the following patch- 143646-16 or later
Other Companies'Servers (x86/x64)
x86/x64Solaris 10 OS
Update 8 or later
OS
SUN Fire Solaris 10 OS10/09 or later
Please apply the following patch- 143645-16 or later
Solaris 10 OS9/10 or later
SPARC Enterprise
11/99 Copyright 2013 FUJITSU LIMITED
Notes - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
SAS connectionModel
100/200
DirectPCI-
ExpressSE0X7SA2F OS bundled MPxIO ー Yes
Supported(V10L80 or later)
DirectPCI-
ExpressSE5X7SA1G OS bundled MPxIO ー Yes
Supported(V10L80 or later)
DirectPCI-
ExpressSE0X7SA1X
FUJITSU ULTRA LDVSCSI Host Bus AdapterDriver 2.1 Update1 or
patch 914572-06 or later
EMPD 3.0.0 PCL 4.2A00 YesSupported
(V10L40 or later)
DirectPCI-
ExpressSE5X7SA1G OS bundled MPxIO ー Yes
Supported(V10L80 or later)
DirectPCI-
ExpressPCI-X
SG-XPCIE8SAS-E-ZSG-XPCI8SAS-E-Z
OS bundled MPxIO - NoSupported
(V10L40 or later)
HBA'sDriver
Solaris 10 OS
Solaris 10 OS
- Update5 of Solaris 10 is required. - the maximum number of LUNs is 32.
Solaris system Path Failover Cluster system Instruction for use
Solaris 10 OS9/10 or later
HBA
Solaris SAS connection [Edition 81 : December 12, 2011]
BootBusOS
Solaris 11 OS
SPARC Enterprise
ConnectedType
When EMPD 2.0.3(for Solaris 10 OS and Solaris 9 OS) or before is used,then please apply patch 914267-06 or later.
12/99 Copyright 2013 FUJITSU LIMITED
FC-FCoE(switch) connection : This sheet is for the system of connection of Server(CNA card) -- FCoE switch - ETERNUS FC port.
Modelvia Switch
(Brocade 8000 orBrocade FCoE blade
only,Fabric OS is v6.3.1a)
via Switch(Brocade
VDX6730、NOS v2.1.1)
via SwitchCisco Nexus5000
Model name BIOS version/EFI driver version
Firmware version FC and FCoE Driverversion 100/200
Supported Planned 2 Planned 2SG-XPCIEFCOE2-Q-SR,
QLE8140/QLE8142- - OS bundled MPxIO - No
Supported(V10L80 or later)
Please use Solaris 10 9/10 or later.
Supported Planned 2 Planned 2SG-XPCIEFCOE2-Q-TA
QLE8150/QLE8152- - OS bundled MPxIO - No
Supported(V10L80 or later)
Please use Solaris 10 9/10 or later.
SPARC Enterprise Solaris 10 OS
Note
Solaris system OS
Connection type HBA
Path Failover Cluster system
Solaris FC-FCoE(switch) connection [Edition 88 : May 15, 2012]
SAN boot Instruction for uses
13/99 Copyright 2013 FUJITSU LIMITED
- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
Model
100/200
HP-UX11iv1
Direct/via switch
PCI-busA6795A/A6826A/
A5158AOS bundled PV-Links - No
Supported(V10L51 or later)
AB378A/AB378B/AB379A/AB379B
OS bundled YesSupported
(V10L10 or later)
A6826A OS bundled YesSupported
(V10L10 or later)
A6795A OS bundled YesSupported
(V10L10 or later)
AD193A/AD194A OS bundled YesSupported
(V10L32 or later)
AD300A OS bundled YesSupported
(V10L32 or later)
AD299A OS bundled YesSupported
(V10L32 or later)
AD355A OS bundled YesSupported
(V10L32 or later)
403619-B21(QMH2462) OS bundled YesSupported
(V10L10 or later)
AB378A/AB378B/AB379A/AB379B
OS bundled YesSupported
(V10L11 or later)
A6826A OS bundled YesSupported
(V10L11 or later)
A6795A OS bundled YesSupported
(V10L11 or later)
AD193A/AD194A OS bundled YesSupported
(V10L32 or later)
AD300A OS bundled YesSupported
(V10L32 or later)
AD299A OS bundled YesSupported
(V10L32 or later)
AD355A OS bundled YesSupported
(V10L32 or later)
403619-B21(QMH2462) OS bundled YesSupported
(V10L11 or later)
Notes - The cluster configurations shown in the table are all 2-node cluster system. Please contact the Storage System Division when two or more clusters are connected to one ETERNUS2000 or one cluster consists of more than 2 nodes.
HBAHP-UX System OS ConnectedType
Bus
PV-Links
Instruction for useDriver Version SwitchPath
FailoverCluster System SAN boot
When connecting with HP-UX, the maximum number of LUNs is up to 128.
VxVM 5.0
Directvia switch
Refer to"ETERNUS2000Server Support
Matrix, FCswitch" chart forsupported FC
switches.
VCS 5.0(including Oracle
RAC)Note 1
HP 9000 Serverrp series
SuperDomeHP Integrity Server
rx seriesSuperDome
HP-UX11iv2
(HP-UX11.23)
via switch
PCI-bus/PCI-Express
Serviceguard
HP-UX FC connection [Edition 95 : January 25, 2013]
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
14/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
AB378A/AB378B/AB379A/AB379B
OS bundled YesSupported
(V10L20 or later)
A6826A OS bundled YesSupported
(V10L20 or later)
A6795A OS bundled YesSupported
(V10L20 or later)
AD193A/AD194A OS bundled YesSupported
(V10L32 or later)
AD300A OS bundled YesSupported
(V10L32 or later)
403619-B21(QMH2462) OS bundled YesSupported
(V10L20 or later)
A5158A OS bundled YesSupported
(V10L51 or later)
AB378A/AB378B/AB379A/AB379B
OS bundled YesSupported
(V10L20 or later)
A6826A OS bundled YesSupported
(V10L20 or later)
A6795A OS bundled YesSupported
(V10L20 or later)
AD193A/AD194A OS bundled YesSupported
(V10L32 or later)
AD300A OS bundled YesSupported
(V10L32 or later)
403619-B21(QMH2462) OS bundled YesSupported
(V10L20 or later)
Serviceguard
HP 9000 Serverrp series
SuperDomeHP Integrity Server
rx seriesSuperDome
HP-UX11iv3
Refer to"ETERNUS2000Server Support
Matrix, FCswitch" chart forsupported FC
switches.
Directvia switch
PCI-bus/PCI-Express
HP-UX System OS ConnectedType
When connecting with HP-UX, the maximum number of LUNs is up to 128.
NativeMultipath
PV-Links Serviceguard
SAN boot Instruction for useBus HBA Driver Version SwitchPath
FailoverCluster System
15/99 Copyright 2013 FUJITSU LIMITED
iSCSI native connectionModel
100/200
HP-UX11iv1
Direct /via switch
HP AB352 IEther-00 B.11.11.14 PV-Links No Supported(V10L40 or later)
When executing vgcreate repetitively, OS may go panic. This panic may be avoided by enlarging Kernel parameter "nproc", such as 4200.
HP-UX11iv2
Direct /via switch
HP AB352 IEther-00 B.11.23.0712 PV-Links No Supported(V10L40 or later)
HP 9000 Serverrp series
SuperDomeHP Integrity Server
rx seriesSuperDome
HP-UX OSConnection
type
- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
HBA Driver version Path Failover
HP-UX iSCSI connection [Edition 72 : March 7, 2011]
Instruction for useiSCSIBoot
- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers.Notes
16/99 Copyright 2013 FUJITSU LIMITED
- AIX MPIO 2.0.2 is no longer available from January 12, 2010. Please use EMPD 2.- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
Model
100/200
5758/19055759/1910
OS bundled NoSupported
(V10L10 or later)
5716/1977 OS bundled NoSupported
(V10L10 or later)
6239 OS bundled NoSupported
(V10L11 or later)When using 6239 (Firmware level: 1.92a1) on AIX 5.2, please apply APAR(IZ05479).
5758/19055759/1910
OS bundled NoSupported
(V10L11 or later)
5716/1977 OS bundled NoSupported
(V10L11 or later)
6239 OS bundled NoSupported
(V10L11 or later)
5716/1977 OS bundled No Planned 2
5758/19055759/1910
OS bundled No Planned 2
Notes
Cluster SystemPath
FailoverAIX System OS ConnectedType
Direct/via switch
AIX 5.2
PCI-bus
Instruction for useSAN boot
HACMP 5.3
EMPD 2.0.0
HBA SwitchDriver Version
VCS 5.0(including Oracle
RAC)Note 1
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
HACMP 5.4
Bus
IBM RS/6000SP/xx/xx/xxIBM P series
IBM System pIBM PowerSystems
When using VxVM 5.0, the maximum number of LUNs is 128.
When using 6239 (Firmware level: 1.92a1) on AIX 5.2, please apply APAR(IZ05479).
Direct/via switch
Refer to"ETERNUS2000Server Support
Matrix, FCswitch" chart forsupported FC
switches.
via switch
PCI-bus
ETERNUSMPIO
2.0.0 orlater
VxVM 5.0
AIX FC connection [Edition 95 : January 25, 2013]
17/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
5758/19055759/1910
OS bundled NoSupported
(V10L10 or later)
5716/1977 OS bundled NoSupported
(V10L10 or later)
6239 OS bundled NoSupported
(V10L11 or later)
6228 OS bundled NoSupported
(V10L51 or later)
via switch PCI-Express 5735 OS bundled NoSupported
(V10L70 or later)
5758/19055759/1910
OS bundled NoSupported
(V10L11 or later)
5716/1977 OS bundled NoSupported
(V10L11 or later)
6239 OS bundled NoSupported
(V10L11 or later)
Direct/via switch
PCI-Express 5773/5774 OS bundledETERNUSMPIO 2.0.1
or laterHACMP 5.4 No
Supported(V10L70 or later)
When using HACMP5.4, please apply APAR(IY87247, IY98754) and ifix(IZ05530).
via switch PCI-Express 5735 OS bundledETERNUSMPIO 2.0.2
HACMP 5.5 NoSupported
(V10L70 or later)
5716/1977 OS bundled NoSupported
(V10L31 or later)
5758/19055759/1910
OS bundled NoSupported
(V10L31 or later)
PCI-Express 5735 OS bundled NoSupported
(V10L31 or later)
5716/1977 OS bundled YesSupported
(V10L80 or later)
5758/19055759/1910
OS bundled YesSupported
(V10L80 or later)
PCI-Express 5735 OS bundled YesSupported
(V10L80 or later)
PCI-bus5758/19055759/1910
OS bundled NoSupported
(V10L77 or later)
PCI-bus 5716/1977 OS bundled NoSupported
(V10L77 or later)
PCI-Express 5735 OS bundled NoSupported
(V10L77 or later)
PCI-bus
EMPD 2.0.0 PowerHA 5.5
PCI-bus
PCI-bus
Direct/via switch
Switch
Refer to"ETERNUS2000Server Support
Matrix, FCswitch" chart forsupported FC
switches.
PathFailover
Oracle10gR2(10.2.0.1.0)
Direct/via switch
Driver Version
AIX 5.3
Instruction for use
ETERNUSMPIO
2.0.0 orlater
EMPD 2.1.0
SAN boot
When using HACMP5.4, please apply APAR(IY87247, IY98754) and ifix(IZ05530).
When using VxVM 5.0, the maximum number of LUNs is 128.VxVM 5.0
Direct/via switch
Direct/via switch
PCI-busvia switch
IBM RS/6000SP/xx/xx/xxIBM P series
IBM System pIBM PowerSystems
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
CSS misscount parameter of Oracle should be set to 60 or more."fc_err_recov" attribute of fscsi should be set to "fast_fail".
VxVM 5.1
VCS 5.1(including Oracle
RAC)Note 1
When using VxVM 5.1, Fjspio v19 is required, and the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
HACMP 5.4
AIX System OS ConnectedType
Bus HBA Cluster System
VCS 5.0(including Oracle
RAC)Note 1
18/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
Direct/via switch
PCI-bus5758/19055759/1910
OS bundledETERNUSMPIO 2.0.1
or later- Planned 2
Supported(V10L60 or later)
Direct/via switch
PCI-Express 5773/5774 OS bundledETERNUSMPIO 2.0.1
or laterHACMP 5.4 Planned 2
Supported(V10L70 or later)
When using HACMP5.4, please apply APAR(IY87247, IY98754) and ifix(IZ05530).
via switch PCI-Express 5735 OS bundledETERNUSMPIO 2.0.2
HACMP 5.5 Planned 2Supported
(V10L70 or later)
5716/1977 OS bundled Planned 2Supported
(V10L31 or later)
5758/19055759/1910
OS bundled Planned 2Supported
(V10L31 or later)
PCI-Express 5773/5774 OS bundled Planned 2Supported
(V10L31 or later)
PCI-Express 5735 OS bundled Planned 2Supported
(V10L31 or later)
PCI-bus5758/19055759/1910
OS bundled NoSupported
(V10L77 or later)
PCI-bus 5716/1977 OS bundled NoSupported
(V10L77 or later)
PCI-Express 5773/5774 OS bundled NoSupported
(V10L77 or later)
PCI-Express 5735 OS bundled NoSupported
(V10L77 or later)
VIOS2.1Direct/
via switch PCI-Express 5735 OS bundled
Refer to"ETERNUS2000Server Support
Matrix, FC switch"chart for supported
FC switches.
*1 see"Instruction
for use"ー No
Supported(V10L79 or later)
*1: VIOS uses EMPD2.0.0, Guest OS uses OS standard (MPIO). - Only AIX 6.1 and AIX 5.3 are supported as Guest OSes. - Only virtual SCSI adapter connection is supported.
Refer to"ETERNUS2000Server Support
Matrix, FCswitch" chart forsupported FC
switches.
Driver Version Instruction for useHBA SAN boot
When using VxVM 5.1, Fjspio v19 is required, and the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) is not necessary.
Direct/via switch
PCI-bus
Switch
VCS 5.1(including Oracle
RAC)Note 1
Bus PathFailover
Note 1 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
AIX System OS ConnectedType
Cluster System
IBM RS/6000SP/xx/xx/xxIBM P series
IBM System pIBM PowerSystems
EMPD 2.0.0 PowerHA 5.5
Direct/via switch VxVM 5.1
AIX 6.1
19/99 Copyright 2013 FUJITSU LIMITED
Notes - Please contact the Storage System Division when a heterogeneous server environment is created using SilkWorm fibre channel switch(es).- Please contact the Storage System Division when MSCS is used.- Please contact FSC or Server group about Windows2000 SP4's availability for each model.- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - For internal FC-switch of other vender's Blade server, please refer to "FC switch" by checking OEM vender's switch model.- GR MultipathDriver is described as "GRMPD", and ETERNUS MultipathDriver is described as "EMPD".- GRMPD has been terminated, if GRMPD is required, please order EMPD which includes GRMPD in its package.- PCI-bus on Bus column indicates PCI or PCI-X.- For HBA's BIOS and driver, please download the listed version from the RIS (Remote Install Service) website. Go to the website https://global.fujitsu-ssw.ne.jp/ris/default.htm, then choose "PRIMERGY HBA drivers for ETERNUS connection" at "Firmware Programs" on the left hand side of the frame.- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
2.41.003 Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
2.00a4
2.16 -QLE2560/QLE2562
5.12a2
WSFCEXPRESSCLUS
TER X 3.1 orlater
BusOS
WSFCEXPRESSCLUS
TER X 3.1 orlater
Hyper-V,Standard, Enterprise, DataCenter,
HPC,SP1
Hyper-V,Standard, Enterprise, DataCenter,
HPCR2/R2 SP1
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe1250
22/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
4.00A1 1.11A5 V2.20.006EMPD V2.0L16
or laterWSFC Yes
Supported(V10L77 or later)
4.00A1 1.11A5 v2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
2.01a2 2.72a2 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L32 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.02a2 2.82a3 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
2.02a2 2.80a4 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.12a6 2.92a4 2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
2.02a2 1.10a5 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L60 or later)
2.02a2 1.11a5 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
5.12a2 2.00a4 2.41.003EMPD V2.0L18
or later
WSFCEXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
5.12a2 2.00a4 2.50.007 or laterEMPD V2.0L19
or laterWSFC
LifeKeeperYes
Supported(V10L82 or later)
2.16 - 9.1.8.25EMPD V2.0L18
or later
WSFCEXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.16 - 9.1.9.25EMPD V2.0L19
or laterLifeKeeper Yes
Supported(V10L82 or later)
Direct/via switch
PCI-bus
S26361-F3023-L1PG-FCD101PG-FCD102
Note 1
1.47 - 9.1.4.15EMPD V2.0L14
or laterNote 3
WSFC yesSupported
(V10L51 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
3.03a2 2.72a2 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC yesSupported
(V10L51 or later)
3.03a9 2.72a2 2.10a7EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
3.03a11 2.82a3 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
3.03a11 2.82a4 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
3.03a11 1.11a5 2.10a7EMPD V2.0L15
or laterNote 3
WSFC yesSupported
(V10L70 or later)
3.03a113.11a5
1.11a5 2.20.006EMPD V2.0L15
or laterNote 3
WSFC yesSupported
(V10L70 or later)
3.11a5 2.00a4 2.41.003EMPD V2.0L18
or later
WSFCEXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
5.12a2 2.00a4 2.50.007 or laterEMPD V2.0L19
or laterWSFC
LifeKeeperYes
Supported(V10L82 or later)
2.02a2 2.72a2 V5-2.10a7EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.12a6 2.92a4 2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
2.02a2 1.10a5 V5-2.10a7EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
5.12a2 2.00a4 2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 3: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
via switch PCI-Express BX600-FC42E 3.03a9 2.72a2 V5-2.10a7 WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
Direct/via switch
PCI-bus/PCI-Express
QLA2340/BX600-FC22Q
1.52 - 9.1.4.15 WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
EMPD V2.0L14or laterNote 3
WSFC YesSupported
(V10L32 or later)
MSDSMNote 3
WSFC YesSupported
(V10L51 or later)EMPD V2.0L14
or laterNote 3
WSFC NoSupported
(V10L33 or later)
MSDSMNote 3
WSFC NoSupported
(V10L33 or later)EMPD V2.0L14
or laterNote 3
WSFC NoSupported
(V10L70 or later)
MSDSMNote 3
WSFC NoSupported
(V10L70 or later)
2.01a2 2.72a2 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L32 or later)
EMPD V2.0L15or laterNote 3
WSFC YesSupported
(V10L70 or later)
MSDSMNote 3
WSFC YesSupported
(V10L51 or later)
2.02a2 2.82a3 2.20.006EMPD V2.0L15
or laterNote 3
WSFC YesSupported
(V10L70 or later)
EMPD V2.0L18or later
WSFC YesSupported
(V10L80 or later)
MSDSM WSFC YesSupported
(V10L80 or later)EMPD V2.0L14
or laterNote 3
WSFC NoSupported
(V10L51 or later)
MSDSMNote 3
WSFC NoSupported
(V10L51 or later)EMPD V2.0L15
or laterNote 3
WSFC NoSupported
(V10L70 or later)
MSDSMNote 3
WSFC NoSupported
(V10L70 or later)EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L40 or later)
EMPD V2.0L15or laterNote 3
WSFC YesSupported
(V10L70 or later)
MSDSMNote 3
- YesSupported
(V10L70 or later)
2.02a2 1.11a5 2.20.006EMPD V2.0L15
or laterNote 3
WSFC YesSupported
(V10L70 or later)
EMPD V2.0L18or later
YesSupported
(V10L80 or later)
MSDSM YesSupported
(V10L80 or later)EMPD V2.0L19
or laterWSFC
LifeKeeperYes
Supported(V10L82 or later)
MSDSMWSFC
LifeKeeperYes
Supported(V10L82 or later)
EMPD V2.0L14or laterNote 3
- NoSupported
(V10L70 or later)
EMPD V2.0L15or laterNote 3
WSFC NoSupported
(V10L70 or later)
MSDSMNote 3
- NoSupported
(V10L70 or later)EMPD V2.0L18
or laterYes
Supported(V10L80 or later)
MSDSM YesSupported
(V10L80 or later)EMPD V2.0L19
or laterLifeKeeper Yes
Supported(V10L82 or later)
MSDSM LifeKeeper YesSupported
(V10L82 or later)Note 3: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2
Hyper-VStandard/Enterprise/
Datacenter, without SP
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
2.16 or later
2.41.003
9.1.7.18
9.1.8.25
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
Hyper-V,Standard/Enterprise,without SP or SP2PRIMERGY
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2
Windows Server2008
(32-bit version)OS
Hyper-V,Standard/Enterprise,
Datacenter,without SP
PCI-bus/PCI-Express
Direct/via switch
V2.01a4
9.1.7.16
2.72a2
Direct/via switch
QLA2340/QLA2342/QLA2344/QLE2360/QLE2362
Direct/via switch
1.92a1
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
Instruction for use
HBA
Bus
2.02
1.54
SystemConfiguration
WSFC
2.00a4
9.1.7.18
Switch
EMPD V2.0L14or laterNote 3
Path Failover
-
2.01a2
-
On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not
supported.
2.41.003
9.1.7.16
-
2.16
-
V2.10a7
5.12a2
9.1.9.25 or later
2.02 -
Hyper-V,Standard/Enterprise/Datacenter,
SP2
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2
Other Companies'Servers
Hyper-V,Standard/Enterprise/
Datacenter,SP2
Hyper-VStandard/Enterprise/
Datacenter, without SP
2.02a2 1.10a5
-
Hyper-V,Standard/Enterprise,
Datacenter,without SP
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2
2.00a4 2.50.007 or later
1.54
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464(Made by QLogic)
2.02
PCI-bus/PCI-Express
9.1.7.18
V2.01a4
-
ConnectedType
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
1.70a3
Direct/via switch
SAN boot
WSFCEXPRESSCLUS
TER X 3.1 orlater
WSFCEXPRESSCLUS
TER X 3.1 orlater
LPe12000/LPe12002/LPe1250
Direct/via switch
Direct/via switch
PCI-Express QLE2560/QLE2562
PCI-bus
Direct/via switch
Hyper-VStandard/Enterprise/
Datacenter, without SP
Hyper-VStandard/Enterprise/
Datacenter, without SP
Hyper-VStandard/Enterprise/
Datacenter, without SP
2.12a6
PCI-bus/PCI-Express
5.12a2
2.92a4
PCI-Express
Hyper-V,Standard/Enterprise/Datacenter,
SP2
24/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
4.00A1 1.11A5 V2.20.006EMPD V2.0L16
or laterWSFC Yes
Supported(V10L77 or later)
4.00A1 1.11A5 v2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
2.01a2 2.72a2 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L40 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.02a2 2.82a3 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
2.02a2 2.80a4 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.12a6 2.92a4 2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
2.02a2 1.10a5 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L60 or later)
2.02a2 1.11a5 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
5.12a2 2.00a4 2.41.003EMPD V2.0L18
or later
WSFCEXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
5.12a2 2.00a4 2.50.007 or laterEMPD V2.0L19
or laterWSFC
LifeKeeperYes
Supported(V10L82 or later)
2.16 - 9.1.8.25EMPD V2.0L18
or later
WSFCEXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
2.16 - 9.1.9.25EMPD V2.0L19
or laterLifeKeeper Yes
Supported(V10L82 or later)
Direct/via switch
PCI-ExpressLPe11000/LPe1102/
LPe11502.02a2 2.72a2 V7-2.10a7
EMPD V2.0L14or laterNote 3
WSFC YesSupported
(V10L70 or later)
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe12502.02a2 1.10a5 V7-2.10a7
EMPD V2.0L14or laterNote 3
WSFC YesSupported
(V10L70 or later)
Direct/via switch
PCI-ExpressQLE2460/QLE2462/
QLE24641.24 - 9.1.4.15
EMPD V2.0L14or laterNote 3
WSFC YesSupported
(V10L70 or later)
Direct/via switch
PCI-bus
S26361-F3023-L1PG-FCD101PG-FCD102
Note 1
1.47 - 9.1.4.15EMPD V2.0L14
or laterNote 3
WSFC yesSupported
(V10L51 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
3.03a2 2.02a1 V2.01a4EMPD V2.0L14
or laterNote 3
WSFC yesSupported
(V10L51 or later)
3.03a9 2.72a2 2.10a7EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
3.03a11 2.82a3 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
3.03a11 2.82a4 2.20.006EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
3.03a11 1.11a5 V2.01a4EMPD V2.0L15
or laterNote 3
WSFC yesSupported
(V10L70 or later)
3.03a113.11a5
1.11a5 2.20.006EMPD V2.0L15
or laterNote 3
WSFC YesSupported
(V10L70 or later)
3.11a5 2.00a4 2.41.003EMPD V2.0L18
or later
WSFCEXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
5.12a2 2.00a4 2.50.007 or laterEMPD V2.0L19
or laterWSFC
LifeKeeperYes
Supported(V10L82 or later)
Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 3: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
OS
S26361-F3306-L1/L201/PG-FC202/PG-FC202L
PCI-Express
HBA
MC-0JFC11/MC-0JFC21
PRIMEQUEST1000 series
PCI-Express
Bus
Windows Server2008
x64 Editions(64-bit version)
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
SAN bootSwitchSystem
ConfigurationWSFC
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
via switch PCI-Express BX600-FC42E 3.03a9 2.72a2 V7-2.10a7EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2340/BX600-FC22Q
1.52 - 9.1.4.15EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L70 or later)
EMPD V2.0L14or laterNote 3
WSFC YesSupported
(V10L32 or later)
MSDSMNote 3
WSFC YesSupported
(V10L51 or later)EMPD V2.0L14
or laterNote 3
WSFC NoSupported
(V10L33 or later)
MSDSMNote 3
WSFC NoSupported
(V10L33 or later)EMPD V2.0L14
or laterNote 3
WSFC NoSupported
(V10L70 or later)
MSDSMNote 3
WSFC NoSupported
(V10L70 or later)EMPD V2.0L14
or laterNote 3
WSFC YesSupported
(V10L32 or later)
EMPD V2.0L15or laterNote 3
WSFC YesSupported
(V10L70 or later)
MSDSMNote 3
WSFC YesSupported
(V10L51 or later)
2.02a2 2.82a3 2.20.006EMPD V2.0L15
or laterNote 3
WSFC YesSupported
(V10L70 or later)
EMPD V2.0L18or later
WSFC YesSupported
(V10L80 or later)
MSDSM WSFC YesSupported
(V10L80 or later)
EMPD V2.0L14or laterNote 3
WSFC NoSupported
(V10L51 or later)
MSDSMNote 3
WSFC NoSupported
(V10L51 or later)EMPD V2.0L15
or laterNote 3
WSFC NoSupported
(V10L70 or later)
MSDSMNote 3
WSFC NoSupported
(V10L70 or later)
EMPD V2.0L14or laterNote 3
WSFC YesSupported
(V10L40 or later)
EMPD V2.0L15or laterNote 3
WSFC YesSupported
(V10L70 or later)
MSDSMNote 3
- YesSupported
(V10L70 or later)
2.02a2 1.11a5 2.20.006EMPD V2.0L15
or laterNote 3
WSFC YesSupported
(V10L70 or later)
EMPD V2.0L18or later
YesSupported
(V10L80 or later)
MSDSM YesSupported
(V10L80 or later)
EMPD V2.0L19or later
WSFCLifeKeeper
YesSupported
(V10L82 or later)
MSDSMWSFC
LifeKeeperYes
Supported(V10L82 or later)
Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 3: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
- On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
-
-
1.54
On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not
supported.
2.41.003
1.92a1
-
2.92a4
2.41.003
9.1.7.18
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.9.1.7.16
PRIMERGY
Direct/via switch
Other Companies'Servers
Hyper-VStandard/Enterprise/
Datacenter, without SP, HPC
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2, HPC
Hyper-V,Standard/Enterprise/Datacenter,
SP22.00a4
Hyper-V,Standard/Enterprise,
without SP or SP2, HPC
Hyper-VStandard/Enterprise/
Datacenter, without SP, HPC
Hyper-VStandard/Enterprise/
Datacenter, without SP, HPC
PCI-bus/PCI-Express
9.1.7.16Direct/
via switch
V2.10a7
2.02
Hyper-VStandard/Enterprise/
Datacenter, without SP, HPC
PCI-bus
Instruction for useSAN bootSwitch
2.12a6
2.72a2 V2.01a4
1.70a3
9.1.7.18
Path FailoverSystem
ConfigurationWSFC
WSFCEXPRESSCLUS
TER X 3.1 orlater
HBA
V2.01a4
Direct/via switch
Windows Server2008
x64 Editions(64-bit version)
OS
Direct/via switch
Hyper-V,Standard/Enterprise,
Datacenter,without SP, HPC
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2, HPC
5.12a2
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464(Made by QLogic)
QLA2340/QLA2342/QLA2344/QLE2360/QLE2362
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
-
1.54
1.10a52.02a2
2.01a2
2.02
Bus
PCI-bus/PCI-Express
ConnectedType
Direct/via switch
PCI-bus/PCI-Express
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2, HPC
Direct/via switch
Hyper-V,Standard/Enterprise/Datacenter,
SP2
Hyper-V,Standard/Enterprise,
Datacenter,without SP, HPC
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
5.12a2 2.00a4 2.50.007 or laterHyper-V,
Standard/Enterprise/Datacenter,without SP or SP2, HPC
LPe12000/LPe12002/LPe1250
Direct/via switch
PCI-Express
26/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
EMPD V2.0L14or laterNote 3
- NoSupported
(V10L70 or later)
EMPD V2.0L15or laterNote 3
WSFC NoSupported
(V10L70 or later)
MSDSMNote 3
- NoSupported
(V10L70 or later)
EMPD V2.0L18or later
YesSupported
(V10L80 or later)
MSDSM YesSupported
(V10L80 or later)
EMPD V2.0L19or later
LifeKeeper YesSupported
(V10L82 or later)
MSDSM LifeKeeper YesSupported
(V10L82 or later)
Direct/via switch
PCI-bus
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
2.02a2 2.82a4 7.2.30.16 NoSupported
(V10L77 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
2.02a2 2.82a4 7.2.30.16 NoSupported
(V10L77 or later)
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe12502.02a2 1.11a5 7.2.30.16 No
Supported(V10L77 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464(Made by QLogic)
(V10L77 or later)Note 3: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
Model
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
MC-08FC31MC-08FC41MC-08FC51MC-08FC61
3.21a5 2.72a2V2.00a12 EMPD V2.0L14
or laterWSFC
Yes(see
Instructionfor use)
Supported(V10L51 or later)
For SAN boot, please apply KB952779.
MC-08FC71 3.21a5 1.92a1V2.00a12 EMPD V2.0L14
or laterWSFC
Yes(see
Instructionfor use)
Supported(V10L51 or later)
For SAN boot, please apply KB952779.
MC-08FC11 4.00a1 1.92a1
MC-08FC31 / MC-08FC41 4.00a1 2.80a4
MC-08FC51 / MC-08FC61 4.00a1 2.80a4
MC-08FC71 4.00a1 1.92a1
MC-08FC81 / MC-08FC91 4.00a1 1.11a5
Other Companies'Servers
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
QLE2560/QLE2562
2.02 -
2.16 - 9.1.8.25
PCI-Express
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2, HPC
Instruction for useSAN bootSystem
ConfigurationWSFC
Path FailoverOS ConnectedType
On Hyper-V configuration, WSFC cluster of Hyper-V hosts is supported.Cluster of Hyper-V guests using shared disk via FC connection is not supported.
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2, HPC
Direct/via switch
Direct/via switch
PCI-bus/PCI-Express
Bus
Hyper-V,Standard/Enterprise/
Datacenter,SP2, HPC
Hyper-VStandard/Enterprise/
Datacenter, without SP, HPC
Direct/via switch
Hyper-V,Standard/Enterprise/
Datacenter,SP2,HPC
OS
Windows Server2008
forItanium-based systems
PRIMEQUEST400/500/500A series
Windows Server2008
x64 Editions(64-bit version)
Windows Server 2008 for Itanium-Based Systems
Path Failover
WSFC
When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array Support Library) isnot necessary.
Supported(V10L70 or later)
Please apply KB952779.
Instruction for useSAN boot
YesEMPD V2.0L14
or later
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
HBA
WSFCEXPRESSCLUS
TER X 3.1 orlater
2.16 or later
9.1.7.18
Switch
HBA
SystemConfiguration
WSFC
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
Switch
VxVM 5.1VCS 5.1Note 4
- 9.1.9.25 or later
V2.10a7(Storport Miniport driver)
Note 4 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
BusConnected
Type
PCI-bus/PCI-Express
27/99 Copyright 2013 FUJITSU LIMITED
ModelWindows
2003StandardEdition
Windows2003
EnterpriseEdition
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
4.00A1 1.11A5 V2.20.006EMPD V2.0L16
or laterMSCS Yes
Supported(V10L77 or later)
4.00A1 1.11A5 v2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
SP1/SP2R2/R2 SP2
- YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2 - YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L60 or later)
- MSCS YesSupported
(V10L60 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch5.12a2 2.00a4 2.50.007 or later
EMPD V2.0L19or later
MSCSLifeKeeper
YesSupported
(V10L82 or later)
Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
2.02a2SP2/
R2 SP2
V2.01a4(Storport Miniport driver)
Direct/via switch
Direct/via switch
Standard/Enterprise/Datacenter,SP2
2.41.003
1.10a5
2.02a2
Direct/via switch
S26361-F3141-L1/PG-FC201
1.91a1
1.91a5
MC-0JFC11/MC-0JFC21
Direct/via switch
Direct/via switch
Bus
- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
(V10L70 or later)Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
ConnectedType
Bus
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
2.10a7(Storport Miniport driver)
yes(see
Instructionfor use)
2.72a2
V1.30a6(Storport Miniport driver)
V2.01a4(Storport Miniport driver)
V9.1.4.15(Storport Miniport driver)
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
2.70x6
V1.30a9(Storport Miniport driver)
Instruction for use
When SAN boot is used, please useBoot BIOS 3.03a2 or later
- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
(V10L70 or later)Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
2.02
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
1.70a3
1.70a3
QLA2340/QLA2342/QLA2344/QLE2360/
QLE2362
1.54
1.54
SP1/SP2R2/R2 SP2
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464(Made by QLogic)
EMPD V2.0L13or later
2.20.006(Storport Miniport driver)
1.24 -
1.52
PCI-bus/PCI-Express
EMPD V2.0L14or later
V2.01a4(Storport Miniport driver)
EMPD V2.0L14or later
V9.1.4.15(Storport Miniport driver)
EMPD V2.0L18or later
V5.30a2(SCSIport Miniport driver)
EMPD V2.0L13or later
Switch
EMPD V2.0L13or later
EMPD V2.0L14or later
2.82a4
1.70a3
Direct/via switch
PCI-bus/PCI-Express
Direct/via switch
PCI-bus/PCI-Express
Direct/via switch
Direct/via switch
Direct/via switch
ConnectedType
Direct/via switch
LP10000/LP10000DC/
LP1050/LP1050DC/LP1050Ex/
LP10000ExDC
Bus
2.02
SP1/SP2R2/R2 SP2
V1.10a4(Storport Miniport driver)
V5.20a8(SCSIport Miniport driver)
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
V9.1.7.16(Storport Miniport driver)
9.1.7.18(Storport Miniport driver)
2.01a2
2.02a2
1.91a1
2.41.003
V1.20a3(Storport Miniport driver)
2.72a2
9.1.4.10(SCSIport Miniport driver)
-
HBA
2.82a3
2.10a7
9.1.4.15(Storport Miniport driver)
Instruction for use
SP1/SP2R2/R2 SP2
SP2/R2 SP2
SP2/R2 SP2
SP1/SP2R2/R2 SP2
R2 SP2
OS
Other Companies'Servers
Windows System2003
(32-bit version)*2
SP2/R2 SP2
SP2/R2 SP2
SP2/R2 SP2
EMPD V2.0L15or later
1.91a1
EMPD V2.0L13or later
2.12a6
EMPD V2.0L14or later
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches. EMPD V2.0L13
or later
SAN bootSystem
ConfigurationMSCS
1.70a3
-
-
2.10a7
-
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
EMPD V2.0L15or later
9.1.7.16(Storport Miniport driver)
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
-
9.1.7.18(Storport Miniport driver)
EMPD V2.0L14or later
EMPD V2.0L13or later
-
Path Failover
1.24
30/99 Copyright 2013 FUJITSU LIMITED
ModelWindows
2003StandardEdition
Windows2003
EnterpriseEdition
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
SP2/R2 SP2
- YesSupported
(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)
SP2/R2 SP2
- YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch5.12a2 2.00a4 2.50.007 or later
EMPD V2.0L19or later
MSCSLifeKeeper
YesSupported
(V10L82 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch2.16 - 9.1.9.25
EMPD V2.0L19or later
LifeKeeper YesSupported
(V10L82 or later)
Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
SystemConfiguration
MSCSSAN boot Instruction for use
Other Companies'Servers
HBA
Switch Path FailoverConnected
TypeBus
2.16
Direct/via switch
Direct/via switch
PCI-Express
PCI-Express
5.12a2
2.02a2LPe12000/LPe12002/
LPe1250
SP2/R2 SP2
Direct/via switch
Direct/via switch
2.02
QLE2560/QLE2562Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
9.1.7.18(Storport Miniport driver)
2.20.006(Storport Miniport driver)
9.1.8.25
EMPD V2.0L14or later
EMPD V2.0L14or later
2.01a4(Storport Miniport driver)
Windows System2003
(32-bit version)*2
OS
R2 SP2
SP2/R2 SP2
SP2/R2 SP2
R2 SP2
-
EMPD V2.0L18or later
-
EMPD V2.0L14or later
1.10a5
2.00a4
2.02a
EMPD V2.0L18or later
1.11a5
2.41.003
31/99 Copyright 2013 FUJITSU LIMITED
Model
Windows2003
StandardEdition
Windows2003
EnterpriseEdition
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
4.00A1 1.11A5 V2.20.006EMPD V2.0L16
or laterMSCS Yes
Supported(V10L77 or later)
4.00A1 1.11A5 v2.41.003EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
SP1/SP2R2/R2 SP2
- YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2 - YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L60 or later)
- MSCS YesSupported
(V10L60 or later)SP2/
R2 SP2- Yes
Supported(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch5.12a2 2.00a4 2.50.007 or later
EMPD V2.0L19or later
MSCSLifeKeeper
YesSupported
(V10L82 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch2.16 - 9.1.9.25
EMPD V2.0L19or later
LifeKeeper YesSupported
(V10L82 or later)
Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
(V10L70 or later)Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
SP2/R2 SP2
PCI-Express
1.11a5
3.03a11
2.10a7(Storport Miniportdriver)
EMPD V2.0L13or later
3.03a11
2.72a2
V1.30a9(Storport Miniport driver)
2.20.006(Storport Miniport driver)
PRIMERGY
PCI-bus/PCI-Express
2.41.003
V1.30a6(Storport Miniport driver)
2.10a7(Storport Miniport driver)
SP1/SP2R2/R2 SP2
R2 SP2
SP2/R2 SP2
1.47
via switch
KB940467 update for Windows2003 is required.
yes(see
Instructionfor use)
EMPD V2.0L13or later
EMPD V2.0L18or later
EMPD V2.0L15or later
EMPD V2.0L14or later
1.70a3
V1.30a9(Storport Miniport driver)
Instruction for use
When SAN boot is used, please useBoot BIOS 3.03a2 or later
EMPD V2.0L13or later
- ServerView (Systemwalker) Resource Coordinator VE environment is notsupported.
2.20.006(Storport Miniport driver)
EMPD V2.0L14or later
EMPD V2.0L15or later
V9.0.2.17(Storport Miniport driver)
EMPD V2.0L13or later
V2.01a4(Storport Miniport driver)
2.70a5
HBA
1.70a3
Path Failover
V9.1.4.15(Storport Miniport driver)
-
SAN boot
PCI-Express
QLA2340/BX600-FC22Q
via switch
Direct/via switch
S26361-F3306-L601PG-FCD201
Note 1
3.11a5via switch
via switch
Direct/via switch
3.03a2
3.03a113.11a5
SP2/R2 SP2
SP1/SP2R2/R2 SP2
Direct/via switch
SP1/SP2R2/R2 SP2
SP1/SP2R2/R2 SP2
2.82a3
1.47 -
SP1/SP2R2/R2 SP2
SP1/SP2R2/R2 SP2
ConnectedType
SP1/SP2R2/R2 SP2
SP1/SP2R2/R2 SP2
SP2R2/R2 SP2
Windows 2003x64 Editions
(64-bit version)*2
OS
EMPD V2.0L14or later
EMPD V2.0L14or later
EMPD V2.0L14or later
2.70x6
V1.30a6(Storport Miniport driver)
2.20.006(Storport Miniport driver)
EMPD V2.0L13or later
S26361-F3023-E1PG-FCD101
Note 1
BX600-FC42E
3.03a9
SystemConfiguration
MSCS
2.00a4
QLe2460/QLe2462
Switch
MC-FC82EPG-FCD202/PY-FCD02
Note 1
3.03a11
1.11a5
2.82a4
2.72a2
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
PCI-Express
Bus
PCI-bus
PCI-Express
33/99 Copyright 2013 FUJITSU LIMITED
Model
Windows2003
StandardEdition
Windows2003
EnterpriseEdition
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
SP1/SP2R2/R2 SP2
- YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)
SP1/SP2R2/R2 SP2
- YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)
SP1/SP2R2/R2 SP2
- YesSupported
(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)
SP2/R2 SP2
- YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2 - YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)
SP2/R2 SP2
- YesSupported
(V10L51 or later)
- MSCS YesSupported
(V10L51 or later)
SP1/SP2R2/R2 SP2
- YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP1/SP2
R2/R2 SP2- Yes
Supported(V10L10 or later)
- MSCS YesSupported
(V10L32 or later)
SP2/R2 SP2
- YesSupported
(V10L51 or later)
- MSCS YesSupported
(V10L51 or later)
SP1/SP2R2/R2 SP2
- YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)SP2/
R2 SP2- Yes
Supported(V10L40 or later)
- MSCS YesSupported
(V10L40 or later)
SP2/R2 SP2
- YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch5.12a2 2.00a4 2.50.007 or later
EMPD V2.0L19or later
MSCSLifeKeeper
YesSupported
(V10L82 or later)
SP2/R2 SP2
- YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
R2 SP2EXPRESSCLUS
TER X 3.1 orlater
YesSupported
(V10L80 or later)
- MSCS YesSupported
(V10L80 or later)
R2 SP2 R2 SP2Direct/
via switch2.16 - 9.1.9.25
EMPD V2.0L19or later
LifeKeeper YesSupported
(V10L82 or later)
Note 2: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
Other Companies'Servers
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
9.1.4.15(Storport Miniport driver)
EMPD V2.0L18or later
EMPD V2.0L13or later
1.91a1
2.72a2
EMPD V2.0L14or later
2.20.006(Storport Miniport driver)
-
9.1.7.18(Storport Miniport driver)
EMPD V2.0L14or later
EMPD V2.0L15or later
-
-
EMPD V2.0L14or later
1.11a5
Switch
2.20.006(Storport Miniport driver)
Instruction for use
V9.1.7.16(Storport Miniport driver)
-
EMPD V2.0L14or later
V9.1.4.15(Storport Miniport driver)
SAN boot
EMPD V2.0L13or later
EMPD V2.0L13or later
Path FailoverSystem
ConfigurationMSCS
Direct/via switch
2.82a3
2.02
PCI-Express QLE2560/QLE2562
SP2/R2 SP2
Direct/via switch
PCI-bus/PCI-Express
Direct/via switch
R2 SP2
PCI-bus/PCI-Express
Direct/via switch
Direct/via switch
Direct/via switch
ConnectedType
QLA2340/QLA2342/QLA2344/QLE2360/
QLE2362
PCI-bus
Direct/via switch
Direct/via switch
Bus
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
1.70a3
1.24
1.54
2.10a7
-
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464(Made by QLogic)
2.02
1.70a3
SP1/SP2R2/R2 SP2
SP1/SP2R2/R2 SP2
SP2/R2 SP2
Windows 2003x64 Editions
(64-bit version)*2
OS
R2 SP2
SP2/R2 SP2
SP2/R2 SP2
SP2/R2 SP2
SP2/R2 SP2
SP1/SP2R2/R2 SP2
SP1/SP2R2/R2 SP2
Direct/via switch
SP1/SP2R2/R2 SP2
R2 SP2Direct/
via switch
SP2/R2 SP2
SP2/R2 SP2
Direct/via switch
2.02
2.02a
2.00a45.12a2
EMPD V2.0L18or later
EMPD V2.0L14or later
-
2.12a6 2.41.003
1.10a5
1.52
1.54
2.16
2.02a2
-
2.41.003
9.1.7.18(Storport Miniport driver)
EMPD V2.0L14or later
2.02a2
V2.01a4(Storport Miniport driver)
9.1.7.16(Storport Miniport driver)
2.82a4
V1.20a3(Storport Miniport driver)
2.01a2
EMPD V2.0L18or later
EMPD V2.0L14or later
EMPD V2.0L14or later
9.1.7.18(Storport Miniport driver)
EMPD V2.0L15or later
2.01a4(Storport Miniport driver)
9.1.8.25
PCI-ExpressLPe12000/LPe12002/
LPe1250
PCI-bus/PCI-Express
HBA
-
V1.10a4(Storport Miniport driver)
34/99 Copyright 2013 FUJITSU LIMITED
Model
Windows2003
EnterpriseEdition
Windows2003
DatacenterEdition
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
SP2 SP2 PCI-bus MC-08FC11 3.11x1 1.91a5V1.30a6V
(Storport Miniport driver)MSCS Yes
Supported(V10L10 or later)
SP2 SP2 3.11x1 2.70a5V1.30a6V
(Storport Miniport driver)MSCS Yes
Supported(V10L10 or later)
SP1/SP2 SP1/SP2 3.11x1 2.70a5V1.30a9
(Storport Miniport driver)MSCS Yes
Supported(V10L10 or later)
SP2 SP2 3.11x1 1.91a5V1.30a6V
(Storport Miniport driver)MSCS Yes
Supported(V10L10 or later)
SP1/SP2 SP1/SP2 3.11x1 1.91a5V1.30a9
(Storport Miniport driver)MSCS Yes
Supported(V10L10 or later)
MC-08FC11 4.00a1 1.92a1
MC-08FC31 / MC-08FC41 4.00a1 2.80a4
MC-08FC51 / MC-08FC61 4.00a1 2.80a4
MC-08FC71 4.00a1 1.92a1
MC-08FC81 / MC-08FC91 4.00a1 1.11a5
- NoSupported
(V10L10 or later)
MSCS NoSupported
(V10L10 or later)
- NoSupported
(V10L10 or later)
MSCS NoSupported
(V10L10 or later)
- NoSupported
(V10L10 or later)
MSCS NoSupported
(V10L32 or later)
SP1
SP1
SP2
Windows 2003for
Itanium-basedsystems
PCI-bus/PCI-Express
SP2
Direct/via switch
Direct/via switch
Other Companies'Servers
PRIMEQUEST400/500/500A series
Direct/via switch
SP1
ConnectedType
OS
3.11a3
1.91a53.11a3
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
EMPD V2.0L13or later
EMPD V2.0L13or later
V1.30a6(Storport Miniport driver)
ー1.08
HBA
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
V1.30a6(Storport Miniport driver)
9.1.4.15(Storport Miniport driver)
V2.10a7(Storport Miniport driver)
Bus
PCI-bus/PCI-Express
MC-08FC31MC-08FC41MC-08FC51MC-08FC61
PCI-bus
PCI-bus/PCI-Express
PCI-bus/PCI-Express
Direct/via switch
Direct/via switch
PCI-bus/PCI-Express
MC-08FC71
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
Switch
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
2.70a5
SystemConfiguration
MSCSSAN boot
MSCS
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
EMPD V2.0L13or later
Instruction for usePath Failover
Please apply KB932755.Supported(V10L70 or later)
Yes
35/99 Copyright 2013 FUJITSU LIMITED
Model
Windows2000
Server
Windows2000
AdvancedServer
model name BIOS version/EFI driver version
Firmwareversion
Driver version 100/200
SP4 - YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)
SP4 - YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
SP4 - YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)
SP4 - YesSupported
(V10L70 or later)
- MSCS YesSupported
(V10L70 or later)
SP4 - YesSupported
(V10L11 or later)
- MSCS YesSupported
(V10L11 or later)
SP4 - YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L20 or later)
SP4 - YesSupported
(V10L10 or later)
- MSCS YesSupported
(V10L10 or later)
SP4 - YesSupported
(V10L11 or later)
- MSCS YesSupported
(V10L11 or later)
SP4 - No Planned 2
- MSCS No Planned 2
Note 1: For connection with ETERNUS2000, FC switch blade or FC Pass-Thru Blade is required.
SP4Direct/
via switch1.70a3 1.91a5
S26361-F3141-L10/L210/PG-FC107
Direct/via switch
Bus
Direct/via switch
PCI-bus
SP4
SP4
OS
Direct/via switch
9.0.2.12
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
PCI-Express
PCI-Express
Direct/viaswitch
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
2.10a7
PCI-bus/PCI-Express
Direct/via switch
1.91a1
5.30a2Direct/
via switch
Direct/via switch
-PCI-busS26361-F3023-L1
Note 1
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
1.70a3
1.70a3
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
Other Companies'Servers
SP4
SP4
SP4
PCI-bus/PCI-Express
PRIMERGY
SP4
Direct/via switch
SP4
Windows System2000
SP4 2.50a6
HBA
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
GRMPDV1.0L14 or later
1.91a1 5.20a8
ConnectedType
5.20a8
5.30a2
S26361-F3306-L1/L201/PG-FC202/PG-FC202L
1.70a3 5.30a2
S26361-F3141-L1/PG-FC201
5.20a81.70a3
Path Failover
Refer to "ETERNUS2000Server Support Matrix,
FC switch" chart forsupported FC switches.
1.70a3 1.91a5
1.70a3
1.91a1
5.20a8
1.47
Switch SAN bootSystem
ConfigurationMSCS
GRMPDV1.0L14 or later
Instruction for use
36/99 Copyright 2013 FUJITSU LIMITED
VDS Hardware ProviderModel
100/200
Yes1.0.3 or later
Yes1.0.3 or later
No plan
Yes1.0.3 or later
Yes1.0.3 or later
No plan
Yes1.4.0 or later
No planWindows Server 2008 R2
for Itanium-based systems
Windows Server 2008 R2x64 Editions
(64-bit version)
VDS Hardware Provider Offer
PRIMEQUEST1000 series
&PRIMERGY
&Other Companies'
ServersWindows Server 2008 forItanium-based systems
Windows2003 forItanium-based systems
Windows Server 2008x64 Editions
(64-bit version)
Windows Server 2008(32-bit version)
Windows2003 R2(32bit version)
Windows2003 R2x64 Editions
(64-bit version)
Instruction for use
- Supported SP is SP2 or later. - Supported HBA driver is "Storport miniport" only.
37 / 99 Copyright 2013 FUJITSU LIMITED
- For HBA's BIOS and driver, please download the listed version from the RIS (Remote Install Service) website. Go to the website https://global.fujitsu-ssw.ne.jp/ris/default.htm, then choose "PRIMERGY HBA drivers for ETERNUS connection" at "Firmware Programs" on the left hand side of the frame.- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
iSCSI native connectionModel
100/200
Direct /via switch
LAN port on [I/O unit}(On board)/MC-0JGE11
V15.1.2 or later 2.08 or later 3.0EMPD V2.0L16
or laterMSCS No
Supported(V10L79 or later)
V11.2 or later 2.06 or later 3.0 EMPD V2.0L14or later
- NoSupported
(V10L32 or later)
V11.2 or later 2.07 or later 3.0 EMPD V2.0L14or later
MSCS NoSupported
(V10L40 or later)
16.3 or later OS bundled 3.0EMPD V2.0L18
or laterEXPRESSCLUS
TER X 3.1~No
Supported(V10L82 or later)
16.8 or later OS bundled 3.0EMPD V2.0L19
or laterLifekeeper No
Supported(V10L82 or later)
16.3 or later OS bundled 3.0EMPD V2.0L18
or laterEXPRESSCLUS
TER X 3.1~No
Supported(V10L82 or later)
16.8 or later OS bundled 3.0EMPD V2.0L19
or laterLifekeeper No
Supported(V10L82 or later)
16.3 or later OS bundled 3.0EMPD V2.0L18
or laterEXPRESSCLUS
TER X 3.1~No
Supported(V10L82 or later)
16.8 or later OS bundled 3.0EMPD V2.0L19
or laterLifekeeper No
Supported(V10L82 or later)
16.3 or later OS bundled 3.0EMPD V2.0L18
or laterEXPRESSCLUS
TER X 3.1~No
Supported(V10L82 or later)
16.8 or later OS bundled 3.0EMPD V2.0L19
or laterLifekeeper No
Supported(V10L82 or later)
16.3 or later OS bundled 3.0EMPD V2.0L18
or laterEXPRESSCLUS
TER X 3.1~No
Supported(V10L82 or later)
16.8 or later OS bundled 3.0EMPD V2.0L19
or laterLifekeeper No
Supported(V10L82 or later)
V11.2 or later 2.06 or later 3.0 EMPD V2.0L14or later
- NoSupported
(V10L40 or later)
V11.2 or later 2.07 or later 3.0 EMPD V2.0L14or later
MSCS NoSupported
(V10L40 or later)
V11.2 or later 2.06 or later 3.0EMPD V2.0L14
or later- No
Supported(V10L32 or later)
V11.2 or later 2.07 or later 3.0 EMPD V2.0L14or later
MSCS NoSupported
(V10L40 or later)
V11.2 or later 2.06 or later 3.0 EMPD V2.0L14or later
- NoSupported
(V10L32 or later)
V11.2 or later 2.07 or later 3.0 EMPD V2.0L14or later
MSCS NoSupported
(V10L40 or later)
2.1.4.17 - - EMPD V2.0L14or later
- NoSupported
(V10L32 or later)
- - MSCS No Planned 2
2.1.4.17 - - EMPD V2.0L14or later
- NoSupported
(V10L32 or later)
- - MSCS No Planned 2
Note 1: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
Windows 2003 System(IA32, EM64T)
*1
iSCSIBoot
Notes
SystemConfiguration
MSCS
Intel PRO/1000 MT
MicrosoftiSCSI SoftwareInitiator version
Intel PRO/1000 PTDirect /
via switch
Instruction for useMicrosoftiSNS version
Path Failover
QLA401x/QLA405x
- For each Operating System, Path Failover software, please apply necessary patches which are suggested by the product suppliers.
Windows iSCSI connection [Edition 97 : June 3, 2013]
Direct/via switch
PG-2871/PY-LA234
Direct/via switch
PG-285/PG-285LPGB285/PGB285L
PY-LA101/PY-LA101LPYBLA101/PYBLA101L
Direct/via switch
PG-2862/PG-28621/PY-LA222
38 / 99 Copyright 2013 FUJITSU LIMITED
iSCSI native connectionModel
100/200
Direct/via switch
LAN port on [I/O unit}(On board)/MC-0JGE11
V15.1.2 or later OS bundledEMPD V2.0L16
or laterWSFC No
Supported(V10L79 or later)
V12.4 or later OS bundledEMPD V2.0L14 or later
Note 2- No
Supported(V10L33 or later)
V12.4 or later OS bundledEMPD V2.0L14 or later
Note 2WSFC No
Supported(V10L40 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
V4.1.3 or later OS bundledEMPD V2.0L14 or later
Note 2- No
Supported(V10L33 or later)
V4.1.3 or later OS bundledEMPD V2.0L14 or later
Note 2WSFC No
Supported(V10L33 or later)
Direct/via switch
On board LAN V14.0 or later OS bundledEMPD V2.0L14 or later
Note 2- No
Supported(V10L20 or later)
Note 2: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
PG-LND201/PG-LND203
Hyper-V,Standard/Enterprise,
without SP/SP2,HPC(HPC is 64bit only)
WSFC under Hyper-V configuration does not supportclustering between Hyper-V guests using shared disksconnected from Hyper-V host via iSCSI connection.
Driver version Instruction for useiSCSIBoot
WSFC under Hyper-V configuration does not supportclustering between Hyper-V guests using shared disksconnected from Hyper-V host via iSCSI connection.
(V10L82 or later)Note 2: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
Driver versionMicrosoft
iSCSI SoftwareInitiator version
Path FailoverSystem Configuration
WSFCiSCSIBoot
Instruction for use
Hyper-V,Standard/Enterprise/Datacenter,
without SP or SP2,HPC(HPC is 64bit only)
Direct /via switch
Intel PRO/1000 MTDirect /
via switch
Intel PRO/1000 PT
OS Connection type NIC or HBA
Hyper-V,Standard/Enterprise/
Datacenter,SP2,
HPC(HPC is 64bit only)
Hyper-V,Standard/Enterprise/
Datacenter,SP2,
HPC(HPC is 64bit only)
Other Companies'Servers
Windows Server 2008Windows Server 2008
x64 Edition(IA32, EM64T)
Hyper-V,Standard/Enterprise/
Datacenter,SP2,
HPC(HPC is 64bit only)
Direct /via switch
HP: NC112T 11.7.32.0 OS bundled
Direct /via switch
HP: NC373T, NC382T 5.2.22.0 OS bundled
Direct /via switch
HP: NC375T 4.0.534.138 OS bundled
16.3 or later OS bundled
16.8 or later OS bundled
Hyper-V,Standard/Enterprise/
Datacenter,SP2,
HPC(HPC is 64bit only)
Direct/via switch Intel Ethernet X520
40 / 99 Copyright 2013 FUJITSU LIMITED
Model
100/200
Direct/via switch
LAN port on [I/O unit}(On board)/MC-0JGE11
V15.1.2 or later OS bundledEMPD V2.0L16
or laterWSFC No
Supported(V10L79 or later)
V14.3 or later OS bundled EMPD V2.0L16 or later WSFC NoSupported
(V10L70 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
16.3 or later OS bundled EMPD V2.0L18 or later
EXPRESSCLUSTERX 3.1~
NoSupported
(V10L82 or later)
16.8 or later OS bundled EMPD V2.0L19 or later
Lifekeeper NoSupported
(V10L82 or later)
Direct/via switch
On board LAN V14.3 or later OS bundled EMPD V2.0L16 or later WSFC NoSupported
(V10L70 or later)
Direct/via switch
PG-LND201/PG-LND203 V14.3 or later OS bundled EMPD V2.0L16 or later WSFC No
- When Offloaded Data Transfer(ODX) function is used,Windows patch is required.
- When Offloaded Data Transfer(ODX) function is used,Windows patch is required.- OS bundled
Direct/via switch
OS bundled
- OS bundled
OS bundled
MicrosoftiSCSI SoftwareInitiator version
42 / 99 Copyright 2013 FUJITSU LIMITED
VDS Hardware ProviderModel
100/200
Yes1.0.3 or later
Yes1.0.3 or later
No plan
Yes1.0.3 or later
Yes1.0.3 or later
No plan
Yes1.4.0 or later
No plan
Windows Server 2008for Itanium-based systems
Windows2003 forItanium-based systems
Windows Server 2008 R2x64 Editions
(64-bit version)
Windows Server 2008x64 Editions
(64-bit version)
Windows2003 R2(32bit version)
Windows Server 2008(32-bit version)
Windows Server 2008 R2for Itanium-based systems
Windows2003 R2x64 Editions
(64-bit version)
- Supported HBA driver is "Microsoft iSCSI Software Initiator" only.
VDS Hardware Provider Offer
PRIMEQUEST1000 series
&PRIMERGY
&Other Companies'
Servers
- Supported SP is SP2 or later. - Supported HBA driver is "Microsoft iSCSI Software Initiator" only.
Instruction for use
43/99 Copyright 2013 FUJITSU LIMITED
Notes - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
SAS connectionModel
model name BIOS version Firmware version Driver version 100/200
DirectPCI-
ExpressPY-SC1Y0/PYBSC1Y0
PY-SC1Y0L/PYBSC1Y0L6.30.00.00 or later
1.30.41.00-IT orlater
OS bundled(Storport Miniport
driver)
EMPDV2.0L19or later
WSFC NoSupported
(V10L82 or later)
DirectPCI-
ExpressPY-SC2Z0/PYBSC2Z0/
PYBSC2Z0L7.07.00.00 or later
5.00.13.00-IT orlater
OS bundled(Storport Miniport
driver)
EMPDV2.0L19or later
WSFC NoSupported
(V10L82 or later)
DirectPCI-
ExpressLSISAS3442E-R 6.30.00.00 or later
1.30.41.00-IT orlater
OS bundled(Storport Miniport
driver)
EMPDV2.0L19or later
WSFC No Supported(V10L82 or later)
Direct/switch
(LSI SAS6160/6161)
PCI-Express
LSI SAS9200-8e 7.07.00.00 or later5.00.13.00-IT or
later
OS bundled(Storport Miniport
driver)
EMPDV2.0L19or later
WSFC NoSupported
(V10L82 or later)
Model
100/200
OS bundled(Storport Miniport driver)
EMPD V2.0L14or laterNote 2
WSFC YesSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterNote 2
WSFC YesSupported
(V10L70 or later)
1.32.00.03EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
1.29.03EMPD V2.0L14
or laterNote 2
WSFC YesSupported
(V10L70 or later)
1.32.00.03EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
OS bundled(Storport Miniport driver)
EMPD V2.0L14or laterNote 2
- NoSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterNote 2
- NoSupported
(V10L70 or later)
1.32.00.03EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
Note 2: When using EMPD on Windows Server 2008 without SP, please apply KB952779.
Path Failover Cluster system
LSISAS3442E-R
Direct
DirectPCI-
Express
OS
PCI-Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
Hyper-V,Standard/Enterpris,
SP2
BootBus
Windows Server2008
(32-bit version)HBA
HBA'sDriver
ConnectedType
Hyper-V,Standard/Enterpris,
without SP / SP2
Hyper-V,Standard/Enterpris,
without SP / SP2
PRIMERGY
DirectPCI-
Express
Other Companies'Servers
LSISAS3442E-R
Hyper-V,Standard/Enterpris,
SP2
Hyper-V,Standard/Enterpris,
SP2
Hyper-V,Standard/Enterpris/
Datacenter,without SP / SP2
OSConnected
TypeBus
HBA
PathFailover
Windows SAS connection [Edition 95 : January 25, 2013]
Instruction for use
Cluster system Boot Instruction for use
PRIMERGY
Standard/Datacenter
Standard/Datacenter
Windows Server2012
x64 Editions(64-bit version)
Other Companies'Servers
Essentials/Standard/Datacenter
Essentials/Standard/Datacenter
44/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
OS bundled(Storport Miniport driver)
EMPD V2.0L14or laterNote 2
WSFC YesSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterNote 2
WSFC YesSupported
(V10L70 or later)
1.32.00.03EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
1.29.03.00EMPD V2.0L14
or laterNote 2
WSFC YesSupported
(V10L70 or later)
1.32.00.03EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
OS bundled(Storport Miniport driver)
EMPD V2.0L14or laterNote 2
- NoSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterNote 2
- NoSupported
(V10L70 or later)
1.32.00.03EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
Note 2: When using EMPD on Windows Server 2008 without SP, please apply KB952779. When using MSDSM on Windows Server 2008 without SP, please apply KB952779 & KB967752.
Model
100/200
OS bundled(Storport Miniport driver)
EMPD V2.0L16or later
WSFC YesSupported
(V10L75 or later)
1.32.00.04EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
OS bundled(Storport Miniport driver)
EMPD V2.0L16or later
WSFC NoSupported
(V10L75 or later)
1.32.00.04EMPD V2.0L18
or laterWSFC Yes
Supported(V10L80 or later)
ConnectedType
HBA'sDriver
LSISAS3442E-R
LSISAS3442E-R
Cluster systemOS
Cluster system Boot
Path Failover Boot
HBA'sDriver
HBA
PCI-Express
Direct
Path Failover
Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC
Windows Server2008 R2
x64 Editions(64-bit version)
PRIMERGY DirectPG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
ConnectedType
Bus HBA
Windows Server2008
(64-bit version)
DirectPCI-
Express
Hyper-V,Standard/Enterpris/
Datacenter,without SP / SP2,
HPC
PCI-Express
PRIMERGY
Bus
Direct
Hyper-V,Standard/Enterpris,
SP2
Hyper-V,Standard/Enterpris/
Datacenter,without SP / SP2,
HPC
Hyper-V,Standard/Enterpris/
Datacenter,without SP / SP2,
HPCPG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
Direct
PCI-Express
Hyper-V,Standard/Enterpris,
SP2
PCI-Express
LSISAS3442E-R
Other Companies'Servers
OS
Hyper-V,Standard/Enterpris,
SP2
Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC
Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC, SP1
Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC, SP1
Other Companies'Servers
Instruction for use
Instruction for use
45/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
1.26.05.00(Storport Miniport driver)
EMPD V2.0L14or later
MSCS YesSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterMSCS Yes
Supported(V10L70 or later)
1.32.00.02EMPD V2.0L18
or laterMSCS Yes
Supported(V10L80 or later)
1.29.03EMPD V2.0L14
or laterMSCS Yes
Supported(V10L70 or later)
1.32.00.02EMPD V2.0L18
or laterMSCS Yes
Supported(V10L80 or later)
1.26.05.00(Storport Miniport driver)
EMPD V2.0L14or later
MSCS NoSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterMSCS No
Supported(V10L70 or later)
1.32.00.02EMPD V2.0L18
or laterMSCS Yes
Supported(V10L80 or later)
Note 1: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
Model
100/200
1.26.05.00(Storport Miniport driver)
EMPD V2.0L14or later
MSCS YesSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterMSCS Yes
Supported(V10L70 or later)
1.32.00.02EMPD V2.0L18
or laterMSCS Yes
Supported(V10L80 or later)
1.29.03EMPD V2.0L14
or laterMSCS Yes
Supported(V10L70 or later)
1.32.00.02EMPD V2.0L18
or laterMSCS Yes
Supported(V10L80 or later)
1.26.05.00(Storport Miniport driver)
EMPD V2.0L14or later
MSCS NoSupported
(V10L40 or later)
1.29.03.00EMPD V2.0L15
or laterMSCS No
Supported(V10L70 or later)
1.32.00.02EMPD V2.0L18
or laterMSCS Yes
Supported(V10L80 or later)
Note 1: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
HBA'sDriver
PCI-Express
LSISAS3442E-R
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
Path Failover Cluster system Boot
Cluster system
SP2/R2 SP2 Direct
Path FailoverHBA'sDriver
Windows2003
Standard Edition/Enterprise Edition
ConnectedType
LSISAS3442E-R
Windows2003
(32-bit version)*1
HBABus
Other Companies'Servers
PCI-Express
Windows 2003x64 Editions
(64-bit version)*1
Windows2003
Standard Edition/Enterprise Edition
SP2/R2 SP2
Bus
SP2/R2 SP2
DirectPCI-
Express
Boot
Direct
ConnectedType
HBA
Other Companies'Servers
SP2/R2 SP2 DirectPCI-
ExpressLSISAS3442E-R
PRIMERGY
DirectPCI-
ExpressLSISAS3442E-R
DirectPCI-
Express
Instruction for use
Instruction for use
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
PRIMERGY
46/99 Copyright 2013 FUJITSU LIMITED
VDS Hardware ProviderModel100/200
Yes1.0.3 or later
Yes1.0.3 or later
No plan
Yes1.0.3 or later
Yes1.0.3 or later
No plan
Yes1.4.0 or later
No plan
Windows Server 2008x64 Editions
(64-bit version)
Windows Server 2008 R2for Itanium-based systems
VDS Hardware Provider Offer Instruction for use
PRIMERGY &Other Companies'
Servers
Windows2003 R2(32bit version)
Windows Server 2008 R2x64 Editions
(64-bit version)
Windows Server 2008(32-bit version)
Windows2003 forItanium-based systems
- Supported SP is SP2 or later. - Supported HBA driver is "Storport miniport" only.
Windows Server 2008for Itanium-based systems
Windows2003 R2x64 Editions
(64-bit version)
47 / 99 Copyright 2013 FUJITSU LIMITED
- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
FCoE connectionModel
Windows2003
Standard Edition
Windows2003
Enterprise Edition
via Switch(Brocade 8000 or
Brocade FCoE bladeonly,
Fabric OS is v6.3.1a)
via Switch(Brocade
VDX6730、NOS v2.1.1)
model nameBIOS version/
EFI driver versionFirmware version
FC and FCoEdriver version 100/200
EMPD V2.0L16or later
- NoSupported
(V10L78 or later)
MSDSM - NoSupported
(V10L78 or later)
EMPD V2.0L16or later
- NoSupported
(V10L78 or later)
MSDSM - NoSupported
(V10L78 or later)
Note 1: Windows Storage Server 2003 R2 is supported on the same condition of Windows Server 2003 R2. Please contact Server supplier for availability of Windows Storage Server.
Modelvia Switch
(Brocade 8000 orBrocade FCoE blade
only,Fabric OS is v6.3.1a)
via Switch(Brocade
VDX6730、NOS v2.1.1)
model nameBIOS version/
EFI driver versionFirmware version
FC and FCoEdriver version 100/200
EMPD V2.0L16or later
- NoSupported
(V10L78 or later)
MSDSM - NoSupported
(V10L78 or later)
EMPD V2.0L16or later
- NoSupported
(V10L78 or later)
MSDSM - NoSupported
(V10L78 or later)
Modelvia Switch
(Brocade 8000 orBrocade FCoE blade
only,Fabric OS is v6.3.1a)
via Switch(Brocade
VDX6730、NOS v2.1.1)
model nameBIOS version/
EFI driver versionFirmware version
FC and FCoEdriver version 100/200
EMPD V2.0L16or later
- NoSupported
(V10L78 or later)
MSDSM - NoSupported
(V10L78 or later)
EMPD V2.0L16or later
- NoSupported
(V10L78 or later)
MSDSM - NoSupported
(V10L78 or later)
2.32.0022.702.200.17
Notes - For each Operating System, Path Failover software, please apply necessary patches which are suggested by the product suppliers.
Windows 2003System
(IA32, EM64T)*1
OS
SystemConfiguration
MSCS
HBA
Supported
Connection type
Path Failover Instruction for useSAN boot
Connection type
2.102.200.28 2.32.002
Supported S26361-F3592L2/L202
Path Failover
Other Companies'Servers
SP2/R2
SP2/R2
Supported
OS
Windows 2008System
(IA32, EM64T)
EmulexOCe10102
HP:NC551i/NC551m/
CN1000E
HBA
S26361-F3592L2/L202
Supported
Supported
4.10a0
Windows Server2008 R2
x64 Editions(64-bit version)
PRIMERGY Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC
Supported S26361-F3592L2/L202
Other Companies'Servers
4.10a0
Path FailoverSystem
ConfigurationWSFC
PRIMERGY
4.10a0
SP2/R2
SP2/R2
Supported
Connection type
Supported
4.10a0
Supported
EmulexOCe10102
HP:NC551i/NC551m/
CN1000E
2.102.200.28 2.32.002Supported
Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC
Supported
2.702.200.17
2.32.002
2.702.200.17
OS HBA
Hyper-VStandard/Enterprise/Datacenter
SAN boot
EmulexOCe10102
HP:NC551i/NC551m/
CN1000E
4.10a0
SP2,HPC(HPC is 64bit only)
SystemConfiguration
WSFC
2.32.002
SAN boot
Windows FCoE connection [Edition 88 : May 15, 2012]
Other Companies'Servers
Windows Server 2008 R2 Standard,Enterprise, DataCenter, HPC
Instruction for use
4.10a0 2.102.200.28Supported
PRIMERGY
Instruction for use
2.32.002
48/99 Copyright 2013 FUJITSU LIMITED
- Please contact the Storage System Division when a heterogeneous server environment is created using SilkWorm fibre channel switch(es).- For each Operating System, Path Failover software, Cluster System software, Volume manager software, please apply necessary patches which are suggested by the product suppliers. - For internal FC-switch of other vender's Blade server, please refer to "FC switch" by checking OEM vender's switch model.- PCI-bus on Bus column indicates PCI or PCI-X. - GRMPD/EMPD's version and patch information for each OS are shown on the following web. http://www.fujitsu.com/downloads/STRSYS/system/eternusmpd_installation_information_linux.pdf- For HBA's BIOS and Driver, please download the listed version from the RIS (Remote Install Service) website. Go to the website https://global.fujitsu-ssw.ne.jp/ris/default.htm, then choose "PRIMERGY HBA Drivers for ETERNUS connection" at "Firmware Programs" on the left hand side of the frame.- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
MC-08FC31/MC-08FC41 3.11x1 2.10a7
MC-08FC51/MC-08FC61 3.11x1 2.50a4
MC-08FC11/MC-08FC71 3.11x1 1.91a5
MC-08FC31/MC-08FC41 3.11x1 2.10a7
MC-08FC51/MC-08FC61 3.11x1 2.50a4
MC-08FC11/MC-08FC71 3.11x1 1.91a5
MC-08FC31/MC-08FC41 3.11x1 2.10a7
MC-08FC51/MC-08FC61 3.11x1 2.50a4
MC-08FC11/MC-08FC71 3.11x1 1.91a5
MC-08FC31/MC-08FC41 3.11x1 2.10a7
MC-08FC51/MC-08FC61 3.11x1 2.50a4
MC-08FC11/MC-08FC71 3.11x1 1.91a5
MC-08FC81/MC-08FC91 4.00a1 1.11a5 OS bundledSupported
*1: Driver Version 8.2.0.48.2p Driver is integrated into the kernel. Driver Version 8.2.0.48.3p Driver is integrated into the kernel. The driver is only available with kernel 2.6.18-164.11.1.el5 and higher.
(V10L22 or later)For this combination, please contact to Fujitsu Storage system to checkconfiguration and support your business.
Direct/via switch
EMPD - No Planned 2
Direct/via switch
PCI-bus/PCI-Express
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
1.70a3 1.91a5OS bundled(8.0.16.27)
EMPD - NoSupported
(V10L20 or later)
1.70a3 2.50a6OS bundled(8.0.16.27)
EMPD - NoSupported
(V10L20 or later)
2.02a2 2.82a3 8.0.16.27 EMPD - NoSupported
(V10L79 or later)
1.52 -OS bundled(8.0.04-d8)
EMPD - NoSupported
(V10L20 or later)
1.52 - 8.1.7.15 EMPD - NoSupported
(V10L33 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
1.24 - 8.1.7.15 EMPD - NoSupported
(V10L33 or later)
Direct/via switch
PCI-bus/PCI-Express
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
2.01a2 1.91a5OS bundled(8.0.16.34)
EMPD - NoSupported
(V10L20 or later)
2.01a2 2.72a2OS bundled(8.0.16.34)
EMPD - NoSupported
(V10L20 or later)
2.02a2 2.82a3 8.0.16.34 EMPD - NoSupported
(V10L79 or later)
1.52 - 8.01-07-d4 EMPD - NoSupported
(V10L20 or later)
1.54 - 8.02.08 EMPD - NoSupported
(V10L40 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
2.02 - 8.02.08 EMPD - NoSupported
(V10L40 or later)
Direct/via switch
EMPD - NoSupported
(V10L70 or later)
via switchVxVM 5.0
MP1- No
Supported(V10L70 or later)
Direct/via switch
EMPD - NoSupported
(V10L70 or later)
via switchVxVM 5.0
MP1- No
Supported(V10L70 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
2.01a2 2.72a2OS bundled(8.0.16.40)
EMPD - NoSupported
(V10L70 or later)
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe12502.02a2 1.10a5 OS bundled
(8.0.16.40)EMPD - No
Supported(V10L60 or later)
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
HBA
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
2.02a2
VCS 5.0(including Oracle
RAC) Note 3No
Clustersystem
SAN boot
For this combination, please contact to Fujitsu Storage system to checkconfiguration and support your business.
Instruction for use
Supported(V10L20 or later)
Supported(V10L22 or later)
No-
Switch Path Failover
PCI-bus/PCI-Express
PCI-bus/PCI-Express
PCI-Express
PCI-bus/PCI-Express
Direct/via switch
VxVM 5.0
QLA2340/QLA2342/QLA2344/QLE2360/
QLE2362
QLE2560/QLE2562
1.10a5 8.0.16.44
8.02.14.01
LPe12000/LPe12002/LPe1250
Refer toFC switch pages.
EMPD
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
QLA2340/QLA2342/QLA2344/QLE2360/
QLE2362
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
PCI-bus/PCI-Express
OS bundled(8.0.16.27)
Bus
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-42.EL]Update 4
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-67.EL]RHEL4.6
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-55.EL]RHEL4.5
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-34.EL]Update 3
Direct/via switch
Direct/via switch
PCI-bus/PCI-Express
ConnectedType
Direct/via switch
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-22.EL]Update 2
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-78.0.1.EL]RHEL4.7
Direct/via switch
OS(Kernel)LINUX
RHEL 4(EM64T)
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
PCI-Express
2.02 -
Other Companies'ServersNote 2
Direct/via switch
via switch
66/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
Direct/via switch
PCI-busLP11000/LP11002/
LP11502.01a2 2.72a2 OS bundled
(8.0.16.46)EMPD - No
Supported(V10L70 or later)
Direct/via switch
PCI-busLP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC2.02a2 1.92a1 OS bundled
EMPD(V2.0L21 or later)
- NoSupported
(V10L80 or later)
Direct/via switch
PCI-Express LPe11000/LPe11002/LPe1150 2.01a2 2.72a2 OS bundled(8.0.16.46)
EMPD - NoSupported
(V10L70 or later)
PCI-Express 2.02a2 1.10a5 OS bundled(8.0.16.46)
EMPD - NoSupported
(V10L70 or later)
5.12a2 2.00a4 OS bundledEMPD
(V2.0L21 or later)- No
Supported(V10L80 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2340/QLA2342/QLA2344/QLE2360/
QLE23621.54 - OS bundled EMPD - No
Supported(V10L70 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
2.02 - OS bundled EMPD - NoSupported
(V10L70 or later)
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-100.EL]RHEL4.9
Direct/via switch
PCI-Express LPe12000/LPe12002/LPe1250
5.12a2 2.00a4 OS bundledEMPD
(V2.0L21 or later)- Yes
Supported(V10L80 or later)
Direct/via switch
PCI-bus/PCI-Express
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
EMPD - No Planned 2
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
EMPD - No Planned 2
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
EMPD - No Planned 2
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
Instruction for useSAN bootLINUX ConnectedType
RedHat Enterprise LinuxAS/ES (v.4 for EM64T)
[2.6.9-89.EL]RHEL4.8
Clustersystem
Path Failover
Refer toFC switch pages.
HBA
Switch
Refer toFC switch pages.
OS(Kernel)
RedHat Enterprise LinuxAS/ES (v.4 for IPF)
RHEL 4(EM64T)
RHEL 4(IPF)
Other Companies'ServersNote 2
Direct/via switch
LPe12000/LPe12002/LPe1250
Bus
67/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
Direct/via switch
PCI-bus/PCI-Express
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
1.70a3 1.91a5 8.1.10.3 EMPD - NoSupported
(V10L11 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
1.70a3 2.50a6 8.1.10.3 EMPD - NoSupported
(V10L11 or later)
Direct/via switch
PCI-busLP11000/LP11002/
LP11502.00a1 2.72a2 8.1.10.9 Device Mapper - No
Supported(V10L22 or later)
Direct/via switch
PCI-ExpressLPe11000/LPe11002/
LPe11501.70a3 1.91a5 8.1.10.9 Device Mapper - No
Supported(V10L22 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2340/QLA2342/QLA2344/QLE2360/
QLE23621.52 -
OS bundled(8.10.07-k1)
EMPD - NoSupported
(V10L20 or later)
Direct/via switch
EMPD - No Planned 2
via switch 1.29 - 8.01.07.15 Device Mapper - NoSupported
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
RHEL5(Intel64)
RedHat Enterprise Linux 5(for Intel64)
Direct/via switch
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
2.02a2 1.92a1 8.2.0.63 No Supported(V10L77 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
2.02a2 2.82a4 8.2.0.63 No Supported(V10L77 or later)
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe12502.02a2 1.11a5 8.2.0.63 No Supported
(V10L77 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464(Made by QLogic)
2.10 - 8.02.23 No Supported(V10L77 or later)
Direct/via switch
PCI-Express QLE2560/QLE2562 2.10 - 8.02.23 No Supported(V10L77 or later)
EMPDSupported
(V10L78 or later)
DeviceMapperSupported
(V10L78 or later)
3.11a5 2.00a4 OS bundled EMPD(V2.0L21 or later)
ー NoSupported
(V10L80 or later)
EMPDSupported
(V10L78 or later)
DeviceMapperSupported
(V10L78 or later)
EMPDSupported
(V10L78 or later)
DeviceMapperSupported
(V10L78 or later)
EMPDSupported
(V10L78 or later)
DeviceMapperSupported
(V10L78 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
2.02a2 2.82a3 8.2.0.63.3pSupported
(V10L80 or later)
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe12502.02a2 1.11a5 8.2.0.63.3p
Supported(V10L80 or later)
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
Other Companies'ServersNote 2
RHEL5(Intel64)
LPe12000/LPe12002/LPe1250
Direct/via switch
PCI-Express 8.02.14.01
Refer toFC switch pages.
Refer toFC switch pages.
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
QLE2560/QLE2562 2.02 -
-
- No
No
Switch
-
No
EMPD
Refer toFC switch pages.
VxVM 5.1
VxVM 5.1 VCS 5.1 No
Clustersystem
SAN bootOS
(Kernel)
2.10 -
RedHat Enterprise Linux 5(for Intel64)
[2.6.18-128.el5]RHEL5.3
No-
LINUX
VxVM 5.1
Instruction for use
When using VxVM 5.1, the maximum number of LUNs is 128.For VxVM 5.1, download of driver for ETERNUS (Array SupportLibrary) is not necessary.
Path Failover
NoDirect/
via switch
Direct/via switch
RedHat Enterprise Linux 5(for Intel64)
[2.6.18-92.el5]RHEL5.2
Direct/via switch
PCI-Express
PCI-Express
Direct/via switch
Red Hat Enterprise Linux 5(for Intel64)
[2.6.18-194.el5]RHEL5.5
LPe12000/LPe12002/LPe1250
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
PCI-bus/PCI-Express
1.10a51.11a5
PCI-Express 8.03.01.04.05.05-k-
Bus
PCI-bus/PCI-Express
Refer toFC switch pages.
8.03.01.04.05.05-k
1.70a32.01a22.02a2
8.2.0.63.3p
Direct/via switch
QLE2560/QLE2562
2.50a62.72a22.80a42.82a3
2.02a2
VCS 5.1(including Oracle
RAC)Note 3
Red Hat Enterprise Linux 5(for Intel64)
[2.6.18-164.el5]RHEL5.4
2.10
8.2.0.63.3p
VCS 5.1
HBAConnected
Type
70/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
Direct/via switch
PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
HP: FC2243/FC2143/FC2142SR/FC2242SR/
LPe1105-HP
IBM: LP1105-BC
3.11a5 2.00a4 OS bundled - YesSupported
(V10L80 or later)
Direct/via switch
PCI-Express
LPe12000/LPe12002/LPe1250
HP: AJ762A/AJ763A
IBM: 42D0485/42D0494
5.12a2 2.00a4 OS bundled - YesSupported
(V10L80 or later)
Direct/via switch
PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
HP: FC2243/FC2143/FC2142SR/FC2242SR/
LPe1105-HP
IBM: LP1105-BC
2.12a6 2.82a4 OS bundled Device Mapper - YesSupported
(V10L82 or later)
EMPD - YesPlanned 1
2012.1
Device Mapper - YesSupported
(V10L82 or later)
EMPD - YesPlanned 1
2012.1
Device Mapper - YesSupported
(V10L82 or later)
Direct/via switch
PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
HP: FC2243/FC2143/FC2142SR/FC2242SR/
LPe1105-HP
IBM: LP1105-BC
2.12a6 2.82a4 OS bundledEMPD
(V2.0L22 or later)- Yes
Supported(V10L81 or later)
Direct/via switch
PCI-Express
LPe12000/LPe12002/LPe1250
HP: AJ762A/AJ763A
IBM: 42D0485/42D0494
5.12a2 2.00a4 OS bundledEMPD
(V2.0L22 or later)- Yes
Supported(V10L81 or later)
Direct/via switch
PCI-Express
QLE2560/QLE2562
HP: Ak344A/AJ764A
IBM: 42D0501/42D0510
2.16 - OS bundledEMPD
(V2.0L22 or later)- Yes
Supported(V10L81 or later)
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
Other Companies'ServersNote 2
RHEL5(Intel64)
HBA
Switch
Refer toFC switch pages.
Path FailoverClustersystem
SAN boot Instruction for useLINUX OS(Kernel)
EMPD(V2.0L21 or later)
Direct/via switch
ConnectedType
Bus
OS bundled
Refer toFC switch pages.
-
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Multiboot 1.94 - OS bundled EMPD(V2.0L21 or later)
- NoSupported
(V10L80 or later)
EMPD(V2.0L22 or later)
- YesSupported
(V10L80 or later)
DeviceMapper - NoSupported
(V10L80 or later)
EMPD(V2.0L22 or later)
- YesSupported
(V10L80 or later)
DeviceMapper - NoSupported
(V10L80 or later)
EMPD(V2.0L22 or later)
- YesSupported
(V10L80 or later)
DeviceMapper - NoSupported
(V10L80 or later)
Direct/via switch
PCI-Express LPe12000/LPe12002/LPe1250
EMPD - YesPlanned 1
2012.1
Direct/via switch
PCI-Express QLE2560/QLE2562 EMPD - YesPlanned 1
2012.1
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
2.12a6
Path Failover
Red Hat Enterprise Linux 6(for x86 & Intel64)
[2.6.32-131.0.15.el6]RHEL6.1
& KVM (Intel64)
Direct/via switch
Direct/via switch
PCI-Express
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
For this combination, please contact to Fujitsu Storage system to checkconfiguration and support your business.
via switchLPe11000/LPe11002/
LPe11501.70a3 2.50a6 8.0.16.27 VxVM 5.0
VCS 5.0(including Oracle
RAC) Note 3No
Supported(V10L22 or later)
For this combination, please contact to Fujitsu Storage system to checkconfiguration and support your business.
Direct/via switch
1.24 - 8.01.07.15 EMPD - NoSupported
(V10L11 or later)
via switch 1.24 - 8.01.07 VxVM 5.0VCS 5.0
(including OracleRAC) Note 3
NoSupported
(V10L22 or later)For this combination, please contact to Fujitsu Storage system to checkconfiguration and support your business.
Direct/via switch
PCI-Express
LPe11000/LPe11002/LPe1150
HP: FC2142SR/FC2242SR/LPe1105-HP
IBM: LP1105-BC
3.11a5 2.00a4 OS bundledEMPD
(V2.0L21 or later)- No Supported
(V10L80 or later)
Direct/via switch
EMPD - NoSupported
(V10L70 or later)
via switchVxVM 5.0MP2RP1
- NoSupported
(V10L70 or later)
Direct/via switch
EMPD - NoSupported
(V10L70 or later)
via switchVxVM 5.0MP2RP1
- NoSupported
(V10L70 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2340/QLA2342/QLA2344/QLE2360/
QLE23621.54 - 8.02.14.01 EMPD - No
Supported(V10L70 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
2.02 - 8.02.14.01 EMPD - NoSupported
(V10L70 or later)
SUSE Linux Enterprise Server 9[2.6.5-7.315-smp]
(SP4)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
2.02 - 8.01.07.15 EMPD - NoSupported
(V10L51 or later)
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
EMPD - No Planned 2
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
EMPD - No Planned 2
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
Refer toFC switch pages.
Bus SAN boot
PCI-Express
QLE2560/QLE2562
Refer toFC switch pages.
Switch
Direct/via switch
Direct/via switch
SUSE9(x86)
SUSE9(EM64T)
SUSE Linux Enterprise Server 9[2.6.5-7.308-smp]
(SP4)
PCI-bus/PCI-Express
PCI-bus/PCI-Express
Path Failover
LPe12000/LPe12002/LPe1250
8.2.0.29
8.02.14.01
HBA
Refer toFC switch pages.
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
LINUX Clustersystem
2.02 -
Instruction for use
2.02a2 1.10a5
ConnectedType
SUSE Linux Enterprise Server 9(SP3)
Other Companies'ServersNote 2
SUSE Linux Enterprise Server 9(SP3)
SUSE Linux Enterprise Server 9(SP3)
SUSE Linux Enterprise Server 9[2.6.5-7.308-smp]
(SP4)
PCI-bus/PCI-Express
PCI-Express
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
8.02.14.01
Direct/via switch
SAN bootSwitch
HBAClustersystem
Path Failover Instruction for useLINUX
8.2.0.29
2.02QLE2560/QLE2562
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
SUSE Linux Enterprise Server 10(SP1)
PCI-ExpressLPe12000/LPe12002/
LPe1250
PCI-bus/PCI-Express
PCI-bus/PCI-Express
SUSE Linux Enterprise Server 10[2.6.16.60-0.21]
(SP2)
PCI-bus/PCI-Express
Direct/via switch
Direct/via switch
Direct/via switch
Direct/via switch
OS bundled(8.1.10.3)
-
SUSE Linux Enterprise Server 10(SP4)
2.12a6 2.82a4
-
Direct/via switch
OS(Kernel)
ConnectedType
Bus
Refer toFC switch pages.
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
1.10a5
PCI-bus/PCI-Express
2.02a2
QLA2340/QLA2342/QLA2344/QLE2360/
QLE2362
PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
HP: FC2243/FC2143/FC2142SR/FC2242SR/
LPe1105-HP
IBM: LP1105-BC
Direct/via switch
PCI-Express
LPe12000/LPe12002/LPe1250
HP: AJ762A/AJ763A
IBM: 42D0485/42D0494
2.16
OS bundled
OS bundledDirect/
via switchPCI-Express
QLE2560/QLE2562
HP: Ak344A/AJ764A
IBM: 42D0501/42D0510
SUSE10(x86)
OS bundled
Refer toFC switch pages.
Direct/via switch
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
2.02a2 1.11a5
Other Companies'ServersNote 2
74/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
1.70a3 2.70a5 EMPD - NoSupported
(V10L20 or later)
1.70a3 2.70a5 Device Mapper - NoSupported
(V10L22 or later)
via switch 1.70a3 2.70a5 8.2.0.29VxVM 4.1
MP4VCS 4.1 MP4
Note 3No
Supported(V10L51 or later)
Maximum number of LUNs per server is 32.Please use ASL from the following Symantec webhttp://seer.entsupport.symantec.com/docs/305198.htm
1.24 - 8.01.07.15 EMPD - NoSupported
(V10L70 or later)
2.02 - 8.02.14.01 EMPD - NoSupported
(V10L70 or later)
1.24 - 8.01.07.15 EMPD - NoSupported
(V10L70 or later)
2.02 - 8.02.14.01 EMPD - NoSupported
(V10L70 or later)
via switch 1.29 -OS bundled(8.01.07-k3)
Device Mapper - NoSupported
(V10L22 or later)
via switch PCI-bus LP11000/LP11002/LP1150 1.70a3 2.70a5 8.2.0.29VxVM 4.1MP4RP3
VCS 4.1 MP4RP3Note 3
NoSupported
(V10L51 or later)
Maximum number of LUNs per server is 32.Please use ASL from the following Symantec webhttp://seer.entsupport.symantec.com/docs/305198.htm
2.02a2 1.92a1 8.2.0.63 No Supported(V10L77 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
2.02a2 2.82a4 8.2.0.63 No Supported(V10L77 or later)
Direct/via switch
PCI-ExpressLPe12000/LPe12002/
LPe12502.02a2 1.11a5 8.2.0.63 No Supported
(V10L77 or later)
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
2.1 - 8.02.23 No Supported(V10L77 or later)
Direct/via switch
PCI-Express QLE2560/QLE2562 2.1 - 8.02.23 No Supported(V10L77 or later)
SUSE Linux Enterprise Server 10[2.6.5-7.244]
(SP3)
Direct/via switch
PCI-Express
QLE2560/QLE2562
HP: Ak344A/AJ764A
IBM: 42D0501/42D0510
2.37 - OS bundled EMPD(V2.0L21 or later)
- No Supported(V10L80 or later)
EMPD - NoSupported
(V10L81 or later)
DeviceMapper - NoSupported
(V10L81 or later)
EMPD - NoSupported
(V10L81 or later)
DeviceMapper - NoSupported
(V10L81 or later)
EMPD - NoSupported
(V10L81 or later)
DeviceMapper - NoSupported
(V10L81 or later)
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
For VxVM 5.1, download of driver for ETERNUS (Array SupportLibrary) is not necessary.
-
VxVM 5.1
OS bundled
Refer toFC switch pages.
Refer toFC switch pages.
Refer toFC switch pages.
VCS 5.1(including Oracle
RAC)Note 3
2.02
2.02a2
LP10000/LP10000DC/LP1050/LP1050DC/
LP1050Ex/LP10000ExDC
Direct/via switch
Direct/via switch
8.2.0.29
2.82a4
SUSE Linux Enterprise Server 10[2.6.16.60-0.21]
(SP2)1.10a5
SUSE Linux Enterprise Server 10(SP1)
8.02.14.01PCI-Express QLE2560/QLE2562
Direct/via switch
QLA2340/QLA2342/QLA2344/QLE2360/
QLE2362
LPe12000/LPe12002/LPe1250
PCI-bus/PCI-Express
Direct/via switch
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
Direct/viaswitch
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
Direct/via switch
PCI-Express
PCI-bus/PCI-Express
PCI-bus/PCI-Express
PCI-Express
PCI-bus/PCI-Express
SUSE Linux Enterprise Server 10[2.6. 16. 60-0. 21-smp]
SP2
Switch Path Failover
Direct/via switch
Direct/via switch
PCI-Express
QLE2560/QLE2562
HP: Ak344A/AJ764A
IBM: 42D0501/42D0510
2.16
Direct/via switch
PCI-Express
LPe12000/LPe12002/LPe1250
HP: AJ762A/AJ763A
IBM: 42D0485/42D0494
2.02a2
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
HP: FC2243/FC2143/FC2142SR/FC2242SR/
LPe1105-HP
IBM: LP1105-BC
2.12a6
LINUX OS(Kernel)
SAN boot Instruction for use
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
- OS bundled
1.11a5 OS bundled
Bus
HBAClustersystem
Other Companies'ServersNote 2
SUSE10(EM64T)
SUSE Linux Enterprise Server 10(SP4)
ConnectedType
OS bundled(8.1.10.3)
75/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
Direct/via switch
PCI-Express
LPe12000/LPe12002/LPe1250
HP: AJ762A/AJ763A
IBM: 42D0485/42D0494
5.12 2.00a4 OS bundled EMPD(V2.0L21 or later)
- No Supported(V10L80 or later)
Direct/via switch
PCI-Express
QLE2560/QLE2562
HP: Ak344A/AJ764A
IBM: 42D0501/42D0510
2.37 - OS bundled EMPD(V2.0L21 or later)
- No Supported(V10L80 or later)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
No Planned 2
Direct/via switch
PCI-Express LPe12000/LPe12002/LPe1250 No Planned 2
Direct/via switch
PCI-bus/PCI-Express
QLA2460/QLA2462/QLE2460/QLE2462/QLE2464
No Planned 2
Direct/via switch
PCI-Express QLE2560/QLE2562 No Planned 2
Direct/via switch
PCI-Express
LPe12000/LPe12002/LPe1250
HP: AJ762A/AJ763A
IBM: 42D0485/42D0494
5.12 2.00a4 OS bundled EMPD(V2.0L21 or later)
- No Supported(V10L80 or later)
Direct/via switch
PCI-Express
QLE2560/QLE2562
HP: Ak344A/AJ764A
IBM: 42D0501/42D0510
2.37 - OS bundled EMPD(V2.0L21 or later)
- No Supported(V10L80 or later)
SUSE10(IPF)
SUSE Linux Enterprise Server 10(SP1)
Direct/via switch
PCI-bus/PCI-Express
LP11000/LP11002/LP1150/LPe11000/LPe11002/LPe1150
1.70a3 2.70a5OS bundled(8.1.10.3)
EMPD - NoSupported
(V10L20 or later)
AsianuxServer
(EM64T)
Asianux Server 3.0[2.6.18-8.10AX]
Direct/via switch
PCI-bus/PCI-Express
QLA2340/QLA2342/QLA2344/QLE2360/
QLE23621.5 - 8.01.07.15 - - No
Supported(V10L20 or later)
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
VCS 5.1(including Oracle
RAC)VxVM 5.1
Refer toFC switch pages.
Refer toFC switch pages.
Refer toFC switch pages.
HBA
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
SUSE11(x86)
SUSE Linux Enterprise Server 11[2.6.32](SP1)
SUSE Linux Enterprise Server 11[2.6.32](SP1)
SUSE Linux Enterprise Server 11[2.6.27. 19-5-default]
GA
SUSE11(EM64T)
SAN boot Instruction for useLINUX OS(Kernel)
ConnectedType
Bus
Other Companies'ServersNote 2
Switch Path FailoverClustersystem
76/99 Copyright 2013 FUJITSU LIMITED
Model
model name BIOS version/EFI driver version
Firmware version Driver version 100/200
EMPD - No Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - NoSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later
EMPD - Yes Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - YesSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later
EMPD - No Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - No Supported(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later
EMPD - Yes Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - YesSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later
EMPD - No Planned 2 xen configuration is not supported.
DeviceMapper - No Planned 2Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later
EMPD - No Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - NoSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86 64.rpm or later
VxVM 5.1 VCS 5.1 No Planned 2
EMPD - Yes Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - YesSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86 64.rpm or later
VxVM 5.1 VCS 5.1 No Planned 2
EMPD - Yes Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - YesSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86_64.rpm or later
VxVM 5.1 VCS 5.1 No Planned 2
EMPD - Yes Supported(V10L82 or later)
xen configuration is not supported.
DeviceMapper - YesSupported
(V10L82 or later)
Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86 64.rpm or later
VxVM 5.1 VCS 5.1 No Planned 2
EMPD - No Planned 2 xen configuration is not supported.
DeviceMapper - No Planned 2Please apply the following patches when using Devicemapper.- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86 64.rpm or later
Note 2: Please check if the listed Linux kernel version is supported on the customer's server.
- -
Note 3 : When configuring cluster under Veritas environment, the number of paths for one storage has an upper limit. Please use the formula below. The number of LUNs shared among clusters x the number of path to these LUNs of one node x the number of nodes < 1024 If multiple clusters are configured with one storage, the left side of above formula is sum of each cluster's above value.
Please apply the following patchiscsi-initiator-utils-6.2.0.872-21.el6 or later
Instruction for use
Red Hat Enterprise Linux 6[2.6.32-220.el6]
RHEL6.2
Please apply the following patchiscsi-initiator-utils-6.2.0.872-21.el6 or later
- For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers.
- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
RHEL 6(x86/Intel64)
Driver version
PRIMERGY
Linux
Please apply the following patchinitscripts-8.45.30-3.el5_5.1 or later
Path FailoverConnection type HBA iSCSIBoot
Direct/via switch
PG-2862/PG-28621/PY-LA222
PG-LND204
PG-2862/PY-LA222
Direct/via switch
Linux iSCSI connection [Edition 98 : October 17, 2013]
Red Hat Enterprise Linux 5(for x86 & Intel64)[2.6.18-274.el5]
RHEL5.7
Clustersystem
Notes
Red Hat Enterprise Linux 5[2.6.18-238.el5]
RHEL5.6
Direct/via switch
Direct/via switch
PG-2871/S26361-F3611-L501/
PY-LA234
RHEL 5(x86 & Intel64)
OS[Kernel]
Direct/via switch
PG-2861/PG-2861L/S26361-F3228-L1/L201
Red Hat Enterprise Linux 5[2.6.18-308.el5]
RHEL5.8
PRIMEQUEST1000 series(PQ1400S2/
1400E2/1400L2/1800E2/1800L2 only)
RHEL 6(x86 & Intel64)
Red Hat Enterprise Linux 6[2.6.32-71.el6]
RHEL6.0& KVM (Intel64)
Red Hat Enterprise Linux 6[2.6.32-131.0.15.el6]
RHEL6.1& KVM (Intel64)
Red Hat Enterprise Linux 5[2.6.18-194.el5]
RHEL5.5
RHEL 5(x86 & Intel64)
78 / 99 Copyright 2013 FUJITSU LIMITED
Model
100/200
Direct Intel PRO/1000 PT OS bundled - NoSupported
(V10L70 or later)
Direct Intel PRO/1000 MT OS bundled - NoSupported
(V10L70 or later)
Direct/via switch
PG-288/PG-288L/PY-LA111/
PG-289/PG-289L/PG-2861/PG-2861L/
PG-28611/PG-2861L1/PG-2891/PG-289L1
OS bundled DeviceMapper - No Supported(V10L81 or later)
Direct/via switch
PG-2862/PG-28621/PY-LA222
OS bundled DeviceMapper - NoSupported
(V10L81 or later)
Direct/via switch
PG-2871/PY-LA234 OS bundled DeviceMapper - NoSupported
(V10L81 or later)
Direct /via switch
PG-288/PG-288L/PY-LA111/
PG-289/PG-289L/PG-2861/PG-2861L/
PG-28611/PG-2861L1/PG-2891/PG-289L1
OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
PG-2871/PY-LA234 OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
PG-285/PG-285L OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
PG-2862/PG-28621/PY-LA222
OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
PG-284G/PG-2841G(L) OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
PG-LND201/PG-LND203 OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
PG-LND204 OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
On board LAN (1Gbps)of blade server or
tower/rackmount S4 or laterOS bundled DeviceMapper - No
Supported(V10L82 or later)
PRIMERGY
SUSE Linux Enterprise Server10
SP2[2.6.16.60-0.21-smp]
SUSE Linux Enterprise Server10
(SP4)
SUSE10(x86 & EM64T)
SuSE11(x86 & EM64T)
Path FailoveriSCSIBoot
DeviceMapper
Instruction for useOS[Kernel]
Clustersystem
NIC or HBA Driver versionConnection type
Please apply the following patches when using Devicemapper.(for x86 version)- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later(for EM64T version)- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86_64.rpm or later
SUSE Linux Enterprise Server11
(SP2)Xen
Linux
79 / 99 Copyright 2013 FUJITSU LIMITED
Model
100/200
Direct /via switch
Intel PRO/1000 PT OS bundled - NoSupported
(V10L11 or later)
Direct /via switch
Intel PRO/1000 MT OS bundled - NoSupported
(V10L11 or later)
DeviceMapper - NoSupported
(V10L78 or later)
EMPD - NoSupported
(V10L78 or later)
Direct /via switch
Intel82572GI/Intel 82571GB
OS bundledEMPD
(V2.0L21 or later)- Yes
Supported(V10L80 or later)
Direct /via switch
Intel 82575EB OS bundledEMPD
(V2.0L21 or later)- Yes
Supported(V10L80 or later)
Red Hat Enterprise Linux 5[2.6.18-274.el5]
RHEL5.7& Xen
Direct /via switch
Intel PRO/1000 PT/Intel PRO/1000 PF
OS bundled EMPD - NoPlanned 1(2012.1)
OS bundled EMPD - NoSupported
(V10L81 or later)
OS bundled DeviceMapper - NoSupported
(V10L81 or later)
Direct / switchIntel82572GI/Intel 82571GB
OS bundledEMPD
(V2.0L21 or later)- No
Supported(V10L80 or later)
Direct / switch Intel 82575EB OS bundledEMPD
(V2.0L21 or later)- No
Supported(V10L80 or later)
EMPD(V2.0L22 or later)
- NoSupported
(V10L80 or later)
DeviceMapper - NoSupported
(V10L80 or later)
EMPD(V2.0L22 or later)
- NoSupported
(V10L80 or later)
DeviceMapper - NoSupported
(V10L80 or later)
Red Hat Enterprise Linux 6RHEL6.2
& KVM (Intel64)
Direct /via switch
Intel PRO/1000 PT/Intel PRO/1000 PF
OS bundled EMPD - NoPlanned 1(2012.1)
Direct /via switch
Intel PRO/1000 PT OS bundled - NoSupported
(V10L40 or later)Patch T00812-15 is required for EMPD.
Direct /via switch
Intel PRO/1000 MT OS bundled - No Supported(V10L40 or later)
Patch T00812-15 is required for EMPD.
Direct Intel PRO/1000 PT OS bundled - NoSupported
(V10L70 or later)
Direct Intel PRO/1000 MT OS bundled - NoSupported
(V10L70 or later)
SUSE Linux EnterpriseServer 10
(SP4)
Direct /via switch
Intel PRO/1000 PT/Intel PRO/1000 PF
OS bundled DeviceMapper - NoSupported
(V10L81 or later)
SUSE Linux Enterprise Server11
[2.6.32](SP1)
Direct Intel PRO/1000 PT OS bundledEMPD
(V2.0L21 or later)- No
Supported(V10L80 or later)
Direct /via switch
Intel PRO/1000 PT OS bundled EMPD(V2.0L21 or later)
- No Planned 2
Direct /via switch
Intel PRO/1000 PT OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
Intel Gigabit ET/ET2/EF OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
Broadcom 5708S OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
Intel 10 Gigabit XF OS bundled DeviceMapper - NoSupported
(V10L82 or later)
Direct /via switch
Intel Ethernet X520 OS bundled DeviceMapper - NoSupported
(V10L82 or later)
SUSE11(x86 & Intel64)
Other Companies'Servers
SuSE Linux EnterpriseServer 11
(SP2)& Xen
Linux OS[Kernel]
SUSE10(x86 & Intel64)
RHEL 6(x86/Intel64)
SUSE Linux Enterprise Server10
SP2[2.6.16.60-0.21-smp]
RedHat Enterprise Linux 5[2.6.18-53-el5]
RHEL5.1
RHEL5(x86 & Intel64)
SUSE Linux Enterprise Server 9(SP3/SP4)
Red Hat Enterprise Linux 5[2.6.18-308.el5]
RHEL5.8
Red Hat Enterprise Linux 5[2.6.18-194.el5]
RHEL5.5
Red Hat Enterprise Linux 6[2.6.32-131.0.15.el6]
RHEL6.1& KVM (Intel64)
Red Hat Enterprise Linux 5[2.6.18-238.el5]
RHEL5.6
DeviceMapper
Red Hat Enterprise Linux 6[2.6.32-71.el6]
RHEL6.0& KVM (Intel64)
Please apply the following patchinitscripts-8.45.30-3.el5_5.1 or later
Path FailoverClustersystem
iSCSIBoot
Please apply the following patchiscsi-initiator-utils-6.2.0.872-21.el6 or later
Direct /via switch
Instruction for use
Intel PRO/1000 PT
EMPDV2.0L00 or later
OS bundled
OS bundled
OS bundled
Driver version
Direct /via switch
Direct /via switch
Intel Gigabit ET/ET2/EF
Intel Ethernet X520
Direct /via switch
Intel PRO/1000 PT/Intel PRO/1000 PF
NIC or HBA
Please apply the following patches when using Devicemapper.(for x86 version)- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later(for EM64T version)- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86_64.rpm or later
SUSE9(x86 & EM64T)
DeviceMapper
Connection type
80/99 Copyright 2013 FUJITSU LIMITED
Notes - For each Operating System, Path Failover software, Cluster System software, please apply necessary patches which are suggested by the product suppliers. - If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
SAS connectionModel
100/200
RedHat Enterprise LinuxAS/ES
[2.6.9-67.EL]RHEL4.6
DirectPCI-
Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled EMPD PCL 4.3A00 Yes
Supported(V10L60 or later)
Red Hat Enterprise LinuxAS/ES
[2.6.9-89.EL]RHEL4.8
DirectPCI-
Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled EMPD PCL Yes
Supported(V10L70 or later)
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
Red Hat Enterprise Linux 5[2.6.18-128.el5]
RHEL5.3Direct
PCI-Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled EMPD - Yes
Supported(V10L70 or later)
Red Hat Enterprise Linux 5[2.6.18-164.el5]
RHEL5.4Direct
PCI-Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled EMPD - Yes
Supported(V10L75 or later)
Red Hat Enterprise Linux 5[2.6.18-194.el5]
RHEL5.5Direct
PCI-Express
PG-228B/PG-228BL OS bundled EMPD PCL YesSupported
(V10L78 or later)
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
Red Hat Enterprise Linux 6[2.6.32-71.el6]
RHEL6.0Direct
PCI-Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled
EMPD(V2.0L21 or later)
- NoSupported
(V10L80 or later)
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
DirectPCI-
ExpressPG-22DC/PG-22DCL/
PY-SC2Z0OS bundled
EMPD(V2.0L22 or later)
- No Supported(V10L80 or later)
SUSE Linux Enterprise Server 10(SP2)
DirectPCI-
ExpressLSISAS3442E-R OS bundled
EMPD(see Instruction
for use)- Yes
Supported(V10L70 or later)
EMPD requires patch T00812-16
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
EMPD - No Supported(V10L81 or later)
DeviceMapper - No Supported(V10L81 or later)
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
DirectPCI-
ExpressPG-228B/PG-228BL/
PY-SC1Y0OS bundled DeviceMapper - No
Supported(V10L82 or later)
DirectPCI-
ExpressPG-22DC/PG-22DCL/
PY-SC2Z0OS bundled DeviceMapper - No
Supported(V10L82 or later)
SUSE Linux Enterprise Server 11(SP1)& Xen
Red Hat Enterprise Linux 6[2.6.32-131.0.15.el6]
RHEL6.1& KVM
SUSE 10(x86 &
EM64T)
RHEL 6(x86 &Intel64)
SUSE Linux Enterprise Server 11(SP2)Xen
PRIMERGY
OS bundled
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
DirectPG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
SUSE11(x86 &
EM64T)
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
OS bundled
OS bundledPCI-
Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201
PCI-Express
OS bundled
RHEL 5(x86 &Intel64)
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled
PG-22DC/PG-22DCL/PY-SC2Z0
Direct
RHEL 4(x86 &
EM64T)
Red Hat Enterprise Linux 5[2.6.18-238.el5]
RHEL5.6& Xen
Red Hat Enterprise LinuxAS/ES (v.4 for x86 & EM64T)
[2.6.9-100.EL ]RHEL4.9
DirectPCI-
Express
SUSE Linux Enterprise Server 10(SP4)Xen
OS[Kernel]
Direct
Direct
DirectPCI-
Express
Linux ConnectedType
Bus
Linux SAS connection [Edition 95: January 25, 2013]
Boot Instruction for useHBA HBA'sDriver
Please apply the following patches when using Devicemapper.(for x86 version)- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later(for EM64T version)- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86_64.rpm or later
Path Failover Cluster system
PCI-Express
OS bundled
PCI-Express
81/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
RedHat Enterprise LinuxAS/ES (v.4 for x86)
[2.6.9-67.EL]RHEL4.6
DirectPCI-
ExpressLSISAS3442E-R OS bundled EMPD - No
Supported(V10L60 or later)
Red Hat Enterprise LinuxAS/ES (v.4 for x86)
[2.6.9-89.EL]RHEL4.8
DirectPCI-
ExpressLSISAS3442E-R OS bundled EMPD - No
Supported(V10L70 or later)
EMPD - NoSupported
(V10L80 or later)
DeviceMapper - NoSupported
(V10L80 or later)
Red Hat Enterprise Linux 5[2.6.18-128.el5]
RHEL5.3Direct
PCI-Express
LSISAS3442E-R OS bundled EMPD - NoSupported
(V10L70 or later)
Red Hat Enterprise Linux 5[2.6.18-164.el5]
RHEL5.4Direct
PCI-Express
LSISAS3442E-R OS bundled EMPD - NoSupported
(V10L75 or later)
EMPD - No Supported(V10L78 or later)
DeviceMapper - No Supported(V10L78 or later)
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
Red Hat Enterprise Linux 6[2.6.32-71.el6]
RHEL6.0Direct
PCI-Express
LSISAS3442E-R OS bundledEMPD
(V2.0L21 or later)- No
Supported(V10L80 or later)
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
DirectPCI-
ExpressLSI SAS9200-8e OS bundled
EMPD(V2.0L22 or later)
- No Supported(V10L80 or later)
SUSE Linux Enterprise Server 10(SP2)
DirectPCI-
ExpressLSISAS3442E-R OS bundled
EMPD(see Instruction
for use)- No Supported
(V10L70 or later)EMPD requires patch T00812-16
EMPD - No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
EMPD - No Supported(V10L81 or later)
DeviceMapper - No Supported(V10L81 or later)
EMPD(V2.0L21 or later)
- No Supported(V10L80 or later)
DeviceMapper - No Supported(V10L80 or later)
DirectPCI-
ExpressLSISAS3442E-R OS bundled DeviceMapper - No
Supported(V10L82 or later)
DirectPCI-
ExpressLSI SAS9200-8e OS bundled DeviceMapper - No
Supported(V10L82 or later)
SUSE Linux Enterprise Server 11(SP2)Xen
SUSE11(x86 &
EM64T)
Other Companies'Servers
RHEL 5(x86 &Intel64)
Red Hat Enterprise LinuxAS/ES (v.4 for x86 & EM64T)
[2.6.9-100.EL ]RHEL4.9
PCI-Express
OS bundled
LSISAS3442E-R OS bundled
OS bundledLSISAS3442E-R
RHEL 6(x86 &Intel64)
OS bundled
DirectPCI-
Express
PG-228B/PG-228BL/S26361-F3271-L1/
S26361-F3271-L201OS bundled
DirectPCI-
Express
PCI-Express
SUSE Linux Enterprise Server 11[2.6.32](SP1)
Direct
Direct
Direct
LSISAS3442E-R
Red Hat Enterprise Linux 5[2.6.18-194.el5]
RHEL5.5
PCI-Express
LSI SAS9200-8e
ConnectedType
Red Hat Enterprise Linux 6[2.6.32-131.0.15.el6]
RHEL6.1& KVM
RHEL 4(x86 &
EM64T)
DirectPCI-
ExpressLSISAS3442E-R
Linux OS[Kernel]
Instruction for useBus HBA HBA'sDriver
Path Failover Cluster system Boot
PCI-Express
LSISAS3442E-R
Please apply the following patches when using Devicemapper.(for x86 version)- kpartx-0.4.9-0.66.1.i586.rpm or later- multipath-tools-0.4.9-0.66.1.i586.rpm or later(for EM64T version)- kpartx-0.4.9-0.66.1.x86_64.rpm or later- multipath-tools-0.4.9-0.66.1.x86_64.rpm or later
OS bundled
SUSE 10(x86 &
EM64T)SUSE Linux Enterprise Server 10
(SP4)Xen
OS bundled
Red Hat Enterprise Linux 5[2.6.18-238.el5]
RHEL5.6& Xen
Direct
82 / 99 Copyright 2013 FUJITSU LIMITED
- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
FC-FCoE(switch) connection : This sheet is for the system of connection of Server(CNA card) -- FCoE switch - ETERNUS FC port.Model
- For each Operating System, Path Failover software, please apply necessary patches which are suggested by the product suppliers.
Linux OS[Kernel]
RHEL 6(x86 &Intel64)& KVM
Red Hat EnterpriseLinux 6
[2.6.32-71.el6]RHEL6.0
Cluster system SAN boot Instruction for usePath Failover
4.10a0 2.702.200.17 8.2.0.71-1
Linux FC-FCoE(switch) connection [Edition 88 : May 15, 2012]
S26361-F3592L2/L202
HBA
Planned 2
Connection type
Notes
SupportedSupported
Other Companies'Servers
SuSE11(x86 &
EM64T)& Xen
SUSE Linux EnterpriseServer 11
(SP1)Xen
SUSE 10(x86 &
EM64T)
SUSE Linux EnterpriseServer 10
(SP3)PRIMERGY
83 / 99 Copyright 2013 FUJITSU LIMITED
- If multipath configuration is supported, then single path configuration is also supported. But multipath configuration may be mandatory because of cluster requirement.
FC-FCoE(switch) connection : This sheet is for the system of connection of Server(CNA card) -- FCoE switch - ETERNUS FC port.Model
When using PG-FC205/PG-FC205L/PG-FC206/PG-FC206L on VMware vSphere 4.1(ESX4.1/ESXi4.1), please download the driverfromVMware web site and apply to ESX. The driver should be used is"VMware ESX/ESXi 4.x Driver CD for QLogic FC-FCoE Driver for 2400/2500/8100/8200 Series Fibre Channel and Converged NetworkAdapters" version "841.k1.16.2-1vmw".Please follow the downloaded README file for apply method.Driver download URLhttp://downloads vmware com/jp/d/info/datacenter downloads/vmware vsphere 4/4 0#drivers tools
Refer to"ETERNUS2000 Server
Support Matrix, FCswitch" chart for
supported FC switches.
S26361-F3306-L601PG-FCD201
- -VMwarestandard
Direct/via switch
MC-FC82EPG-FCD202/PY-FCD02
LP11000/LP11002/LP1150
LPe11000/LPe11002/LPe1150
- -VMwarestandard
Direct/via switch
VMwarestandard
Direct/via switch
LP10000/LP1050 - -
When using QLE2560/QLE2562 on VMware vSphere 4.1(ESX4.1/ESXi4.1), please download the driver fromVMware web site and apply to ESX. The driver should be used is"VMware ESX/ESXi 4.x Driver CD for QLogic FC-FCoE Driver for 2400/2500/8100/8200 Series Fibre Channel and Converged NetworkAdapters" version "841.k1.16.2-1vmw".Please follow the downloaded README file for apply method.Driver download URLhttp://downloads.vmware.com/jp/d/info/datacenter_downloads/vmware_vsphere_4/4_0#drivers_tools
SAN boot of ESXi 4.0 is not supported.When using PG-FC205/PG-FC205L/PG-FC206/PG-FC206L on VMware vSphere 4.0(ESX4.0/ESXi4.0) Update1/Update2,please download the driver from VMware web site and apply to ESX. The driver should be used is"VMware ESX/ESXi 4.x Driver CD for QLogic FC-FCoE Driver for 2400/2500/8100/8200 Series Fibre Channel and Converged NetworkAdapters" version "841.k1.16.2-1vmw".Please follow the downloaded README file for apply method.Driver download URLhttp://downloads.vmware.com/jp/d/info/datacenter downloads/vmware vsphere 4/4 0#drivers tools
MC-FC82EPG-FCD202/PY-FCD02
- -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
LP10000/LP1050 - -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
LP1050ex - -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
LP11000/LP1150 - -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
LPe1150 - -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
LPe12000/LPe12002/LPe1250
- -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
QLA2340/QLA2342 - -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
QLA2460/QLA2462 - -VMwarestandard
Direct/via switch
Yes Supported(V10L75 or later)
QLE2560/QLE2562 2.1 - 841.k1.16.2-1vmwDirect/
via switchYes Supported
(V10L80 or later)
SAN boot of ESXi 4.0 is not supported.When using QLE2560/QLE2562 on VMware vSphere 4.0(ESX4.0/ESXi4.0) Update1/Update2,please download the driver from VMware web site and apply to ESX. The driver should be used is"VMware ESX/ESXi 4.x Driver CD for QLogic FC-FCoE Driver for 2400/2500/8100/8200 Series Fibre Channel and Converged NetworkAdapters" version "841.k1.16.2-1vmw".Please follow the downloaded README file for apply method.Driver download URLhttp://downloads.vmware.com/jp/d/info/datacenter downloads/vmware vsphere 4/4 0#drivers tools
SAN boot of ESXi 4.0 is not supported.When using QLE2560/QLE2562 on VMware vSphere 4.0(ESX4.0/ESXi4.0),please download the driver from VMware web site and apply to ESX. The driver should be used is"VMware ESX/ESXi 4.x Driver CD for QLogic FC-FCoE Driver for 2400/2500/8100/8200 Series Fibre Channel and Converged NetworkAdapters" version "841.k1.16.2-1vmw".Please follow the downloaded README file for apply method.Driver download URLhttp://downloads.vmware.com/jp/d/info/datacenter downloads/vmware vsphere 4/4 0#drivers tools
ETERNUS Multipath driver support on VMware Consolidated Backup (VCB) connection
model100/200
1.5/1.5U1/1.5U2
V2.0L14 or laterSupported
(V10L51 or later)
1.5/1.5U1/1.5U2
V2.0L14 or laterSupported
(V10L51 or later)
1.5/1.5U1/1.5U2
V2.0L14 or laterSupported
(V10L51 or later)
1.5/1.5U1/1.5U2
V2.0L14 or laterSupported
(V10L51 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L51 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L51 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L51 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L51 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U1/1.5U2 V2.0L14 or laterSupported
(V10L75 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
1.5U2 V2.0L14 or laterSupported
(V10L78 or later)
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility" - Server Core(command line) installations of Windows Server 2008 Standard/Enterprise/Datacenter are not supported.
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility" - Server Core(command line) installations of Windows Server 2008 Standard/Enterprise/Datacenter are not supported.
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility"
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility"
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility" - Server Core(command line) installations of Windows Server 2008 Standard/Enterprise/Datacenter are not supported.
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility" - Server Core(command line) installations of Windows Server 2008 Standard/Enterprise/Datacenter are not supported.
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility"
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility"
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility" - Server Core(command line) installations of Windows Server 2008 Standard/Enterprise/Datacenter are not supported.
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility" - Server Core(command line) installations of Windows Server 2008 Standard/Enterprise/Datacenter are not supported.
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility"
- Single path connection is supported (no ETERNUS Multipath Driver) - For compatibility of VCB, please refer to "VMware Consolidated Backup Compatibility"
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server. If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for send and receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected toETERNUS.
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
LAN switch(See Instruction for use)
Broadcom 5708SVMwarestandard
VMware standard VMware standard No Planned 2
LAN switch(See Instruction for use)
Intel 10 Gigabit XF VMwarestandard
VMware standard VMware standard No Planned 2
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
Note 1 : VMware ESX does not support boot from iSCSI storage.
Notes
VMware iSCSI connection [Edition 97 : June 3, 2013]
Path Failover iSCSI BootNote 1
Instruction for use
PRIMEQUEST1000 series(PQ1400S2/
1400E2/1400L2/1800E2/1800L2
only)
VMware vSphere5.1(ESXi 5.1)
NIC or HBA
LAN switch(See Instruction for use)
PG-288/PG-288L/PY-LA111/
PG-289/289L/PG-2861/2861L/
PG-28611/PG-2861L1/PG-2891/PG-289L1/
PG-LND201/PG-LND203PY-LAD04/PYBLAD041/
PYBLAD042
LAN switch(See Instruction for use)
PG-285/PG-285L/PGB285/PGB285L
PY-LA101/PY-LA101LPYBLA101/PYBLA101L
LAN switch(See Instruction for use)
PG-2862/PGB2862/PGB2862L/PY-LA222
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server. If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for send and receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected toETERNUS.
Server HBA's Driver Software Initiator
OtherCompanies'
Servers
VMware vSphere5.1(ESXi 5.1)
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server. If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for send and receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected toETERNUS.
VMware vSphere 5 ConnectedType
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-2871/PY-LA234VMwarestandard
VMware standard
VMwarestandard
VMware standard
VMwarestandard
VMware standard
PG-284G/PG-284GL/PG-2841G(L)/
PGB284G/PGB284GLPY-LA242
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-LND204/PGBLND204/PGBLND2042
VMwarestandard
VMware standard
Intel Gigabit ET/ET2/EFVMwarestandard
VMware standard
PRIMERGYVMware vSphere5.1
(ESXi 5.1)
LAN switch(See Instruction for use)
On board LANVMwarestandard
VMware standard
LAN switch(See Instruction for use)
LAN switch(See Instruction for use)
Intel Ethernet X520VMwarestandard
VMware standard
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server. If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for send and receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected toETERNUS.
LAN switch(See Instruction for use)
Intel PRO/1000 PT/Intel PRO/1000 PF
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
93/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
LAN switch(See Instruction for use)
LAN port on [I/O unit}(On board)
VMwarestandard
VMwarestandard
VMwarestandard
No Planned 12012.1
LAN switch(See Instruction for use)
MC-0JGE31/MC-0JXE11VMwarestandard
VMwarestandard
VMwarestandard
No Planned 12012.1
PRIMEQUEST1000 series(PQ1400S/
1400E/1400L/1800E/1800L only)
VMware vSphere 5.0(ESXi 5.0)
LAN switch(See Instruction for use)
LAN port on [I/O unit}(On board)/MC-0JGE11
VMwarestandard
VMwarestandard
VMwarestandard
No Planned 12012.1
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server.If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for sendand receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected to ETERNUS.
VMware standard NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMware standard NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMwarestandard
No Supported(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMwarestandard
No Supported(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMwarestandard
No Supported(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMwarestandard
No Supported(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMwarestandard
No Supported(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
VMwarestandard
No Supported(V10L61 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L61 or later)
VMwarestandard
No Supported(V10L61 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L61 or later)
LAN switch(See Instruction for use)
Broadcom 5708SVMwarestandard
VMwarestandard
VMwarestandard
No △
LAN switch(See Instruction for use)
Intel 10 Gigabit XF VMwarestandard
VMwarestandard
VMwarestandard
No △
VMwarestandard
No Supported(V10L80 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L80 or later)
Note 1 : VMware ESX does not support boot from iSCSI storage.
PRIMEQUEST1000 series
(PQ1400S2 Lite/1400S2/1400E2/1400L2/1800E2/
1800L2 only)
VMware vSphere5.0(ESXi 5.0)
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server.If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for sendand receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected to ETERNUS.
Path FailoverSoftware InitiatoriSCSIBoot
Note 1Server VMware vSphere 5 Connected
TypeNIC or HBA
Other Companies'Servers
VMware vSphere5.0(ESXi 5.0)
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and portconnected to server. If each port of LAN switch can not be set individually, then disable entire LAN switch. If theswitch has separate setting for send and receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected toETERNUS.
Instruction for use
VMware vSphere5.0(ESXi 5.0)
PRIMERGY
HBA's Driver
LAN switch(See Instruction for use)
PG-288/PG-288L/PG-289/289L/
PG-2861/2861L/PG-LND201/PG-LND203/
S26361-F3451-L1/S26361-F3331-L1/
S26361-F3241-L1/L201/S26361-F3228-L1/L201
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-2871/S26361-F3611-L501/
PY-LA234
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-285/PG-285L/PGB285/PGB285L
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-2862/PGB2862/PGB2862L/PY-LA222
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-284G/PG-284GL/PG-2841G(L)/
S26361-F3555-L501
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
PG-LND204/S26361-F3997-L1
VMwarestandard
VMware standard
VMware standard
LAN switch(See Instruction for use)
On board LANVMwarestandard
VMware standard
LAN switch(See Instruction for use)
Intel PRO/1000 PT/Intel PRO/1000 PF
VMwarestandard
VMware standard
LAN switch(See Instruction for use)
Intel Gigabit ET/ET2/EFVMwarestandard
VMware standard
LAN switch(See Instruction for use)
Intel Ethernet X520VMwarestandard
94/99 Copyright 2013 FUJITSU LIMITED
Model
100/200
VMware vSphere 4.1(ESX 4.1)
LAN switch(See Instruction for use)
LAN port on [I/O unit}(On board)/MC-0JGE11
VMwarestandard
VMware standard VMware standard NoSupported
(V10L79 or later)
VMware vSphere 4(ESX 4.0)Update1
LAN switch(See Instruction for use)
LAN port on [I/O unit}(On board)/MC-0JGE11
VMwarestandard
VMware standard VMware standard NoSupported
(V10L79 or later)
VMwarestandard
NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
NoSupported
(V10L80 or later)
VMwarestandard
NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
NoSupported
(V10L80 or later)
LAN switch(See Instruction for use)
PG-288/PG-288L/PG-289/289L/
PG-2861/2861L/PG-LND201/PG-LND203/
PG-2871/S26361-F3611-L501/
S26361-F3241-L1/L201/S26361-F3228-L1/L201
VMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L80 or later)
LAN switch On board LANVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L80 or later)
LAN switch(See Instruction for use)
PG-288/PG-288L/PG-289/289L/
PG-2861/2861L/PG-LND201/PG-LND203/
PG-2871/S26361-F3611-L501/
S26361-F3241-L1/L201/S26361-F3228-L1/L201
VMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L70 or later)
LAN switch(See Instruction for use)
On board LANVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L70 or later)
VMwarestandard
NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
NoSupported
(V10L80 or later)
VMwarestandard
NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
NoSupported
(V10L80 or later)
LAN switch(See Instruction for use)
Intel PRO/1000 PTVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L80 or later)
LAN switch(See Instruction for use)
Intel PRO/1000 PFVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L80 or later)
LAN switch(See Instruction for use)
Intel PRO/1000 PTVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L70 or later)
LAN switch(See Instruction for use)
Intel PRO/1000 MTVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L70 or later)
LAN switch(See Instruction for use)
Intel PRO/1000 PFVMwarestandard
VMware standardVMwarestandard
NoSupported
(V10L70 or later)
LAN switch QLA405xVMwarestandard - Planned 2
LAN switch QLE406xVMwarestandard - Planned 2
Note 1 : VMware ESX does not support boot from iSCSI storage.
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server.If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for sendand receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected to ETERNUS.
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server.If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for sendand receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected to ETERNUS.
Please disable "Flow Control" of LAN switch.- If each port of LAN switch can be set individually, then disable both port connected to ETERNUS and port connected to server.If each port of LAN switch can not be set individually, then disable entire LAN switch. If the switch has separate setting for sendand receive, then disable "Flow Control" for both send and receive.- When multiple LAN switches are cascaded, please apply this to the switches which are directly connected to ETERNUS.
Notes - For HBAs not listed here, please refer to the Compatibility Guides on VMware website. http://www.vmware.com/support/pubs/vi_pubs.html For detail, please ask each server vendor.
SAS connectionModel
model name BIOS version Firmware version Driver version 100/200
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard No Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
No Supported(V10L82 or later)
VMware standard Yes Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
Yes Supported(V10L82 or later)
VMware standard Yes Supported(V10L82 or later)
VMwareVAMP1.1.0 or later
Yes Supported(V10L82 or later)
Model
Name BIOS Firmware version Driver version 100/200
VMware standard NoSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
NoSupported
(V10L80 or later)
DirectPG-22DC/PG-22DCL/
PY-SC2Z0VMwarestandard
VMware standard No Planned 2
VMware standard YesSupported
(V10L80 or later)
VMwareVAMP1.1.0 or later
NoSupported
(V10L80 or later)
Direct LSI SAS9200-8eVMwarestandard
VMware standard Yes Planned 2
HBA
Direct
PG-228B/PG-228BL/PY-SC1Y0/
S26361-F3271-L1/S26361-F3271-L201
VMwarevSphere 5
Path Failover iSCSI Boot Instruction for useConnected
TypeServer
HBA
Path Failover Boot
VMware SAS connection [Edition 97 : June 3, 2013]
PRIMERGYVMware
vSphere 5.0(ESXi 5.0)
OtherCompanies'
Servers
VMwarevSphere 5.0(ESXi 5.0)
Instruction for use
PRIMERGYVMware
vSphere 5.1(ESXi 5.1)
Direct
OtherCompanies'
Servers
VMwarevSphere 5.1(ESXi 5.1)
Direct
ServerVMware
vSphere 5Connected
Type
PG-228B/PG-228BL/PY-SC1Y0
6.30.00.00 or later 1.30.41.00-ITVMwarestandard
PG-22DC/PG-22DCL/PY-SC2Z0
7.07.00.00 or later5.00.13.00-IT or
laterVMwarestandard
LSISAS3442E-R 6.30.00.00 or later 1.30.41.00-IT VMware standard
LSI SAS9200-8e 7.07.00.00 or later5.00.13.00-IT or lateVMware standard
VMwarestandard
Direct LSISAS3442E-RVMwarestandard
97/99 Copyright 2013 FUJITSU LIMITED
Model
Name BIOS Firmware version Driver version 100/200
Direct
PG-228B/PG-228BL/PY-SC1Y0/
S26361-F3271-L1/S26361-F3271-L201
6.30.00.00 1.30.41.00-ITVMwarestandard
VMware standard NoSupported
(V10L80 or later)
Direct LSISAS3442E-R 6.30.00.00 1.30.41.00-ITVMwarestandard
VMware standard NoSupported
(V10L80 or later)
1.27.41.00-ITSupported
(V10L80 or later)
1.30.40.00-ITSupported
(V10L80 or later)Host Affinity function can not be used.Please disable Host Affinity function.
Direct LSISAS3442E-R 6.26.00.00 1.27.41.00-ITVMwarestandard
VMware standard YesSupported
(V10L78 or later)
Direct
PG-228B/PG-228BL/PY-SC1Y0/
S26361-F3271-L1/S26361-F3271-L201
6.30.00.00 1.30.41.00-ITVMwarestandard
VMware standard NoSupported
(V10L80 or later)
Direct LSISAS3442E-R 6.30.00.00 1.30.41.00-ITVMwarestandard
VMware standard NoSupported
(V10L80 or later)
Direct LSISAS3442E-R 6.26.00.00 1.27.41.00-ITVMwarestandard
VMware standard YesSupported
(V10L78 or later)
1.27.41.00-ITSupported
(V10L70 or later)
1.30.40.00-ITSupported
(V10L80 or later)Host Affinity function can not be used.Please disable Host Affinity function.
Direct LSISAS3442E-R 6.26.00.00 1.27.41.00-ITVMwarestandard
(V10L33 or later)Please apply driver patch for Egenera (EgenWin-2003.1.1.5 or later) when using Windows server as a guest OS.
embeddedDirect/
via switchYes Supported
(V10L70 or later)Please apply driver patch for Egenera (EgenWin-2003.1.1.5 or later) when using Windows 2003 server as a guest OS.
BladeFrame EX/ESPAN Version 5.2
Refer to "ETERNUS2000Server Support Matrix, FCswitch" chart for supported
FC switches.
BladeFrame EX/ESPAN Version 5.0/5.1
Egenera HBAConnected
Type
Egenera BladeFrame [Edition 95 : January 25, 2013]Notes
Switch Instruction for useSAN boot
99/99 Copyright 2013 FUJITSU LIMITED
Switch connection [Edition 98 :October 17, 2013]Notes - This chart shows connectivity between ETERNUS host interface and each switch. For connectivity between host bus adapter and switch, please ask it to server and/or switch vendor.