Top Banner
16
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: EMC OSRAM
Page 2: EMC OSRAM

2/4 Form_EC_100316

EC-Declaration of Conformity Annex Document-No.: 2010 / QT_ENDURA_01

The conformity of the designated product(s) with the provisions of the European Directive 2006/95/EC is given by the compliance with the following European Standard(s). The latest

amendment applies, even if not mentioned below.

EN 61347-1: 2008 Lamp controlgear – Part 1: General and safety requirements

EN 61347-2-1: 2009 Lamp controlgear – Part 2-1: Particular requirements for starting devices (other than glow starters)

EN 61347-2-2: 2001 +A1:2006 + A2:2006-06

Lamp controlgear – Part 2-2: Particular requirements for d.c. or a.c. supplied electronic step-down convertors for filament lamps

EN 61347-2-3: 2001 +A1:2004+A2:2006

Lamp controlgear – Part 2-3: Particular requirements for a.c. supplied electronic ballasts for fluorescent lamps

EN 61347-2-4: 2001 Lamp controlgear - Part 2-4: Particular requirements for d.c. supplied electronic ballasts for general lighting

EN 61347-2-5: 2001 Lamp controlgear - Part 2-5: Particular requirements for d.c. supplied electronic ballasts for public transport lighting

EN 61347-2-6: 2001 Lamp controlgear - Part 2-6: Particular requirements for d.c. supplied electronic ballasts for aircraft lighting

EN 61347-2-7: 2006 Lamp controlgear - Part 2-7: Particular requirements for d.c. supplied electronic ballasts for emergency lighting

EN 61347-2-8: 2001 +A1:2006

Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps

EN 61347-2-9: 2001 +A1:2003 + A2:2006

Lamp controlgear - Part 2-9: Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps

EN 61347-2-10: 2001 +A1:2009

Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)

EN 61347-2-11: 2001 + A1:2008

Lamp controlgear - Part 2-11: Particular requirements for miscellaneous electronic circuits used with luminaires

EN 61347-2-12: 2005 Lamp controlgear – Part 2-12: Particular requirements for d.c. or a.c. supplied electronic ballasts for discharge lamps (excluding fluorescent lamps)

EN 61347-2-13: 2007 Lamp controlgear – Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

EN 60669-2-11: 2004 Switches for husehold and similar fixed electrical installations – Part 2-1: Particular reqirements – Electronic switches

EN 60968: 1990 +A1:1993+A2:1999 Self-ballasted lamps for general lighting services – Safety requirements

EN 62031: 2008 LED modules for general lighting – Safety specifications

EN 62471: 2008 Photobiological safety of lamps and lamp systems NOTE: This is a horizontal standard. It is not applicable if photobiological safety is covered by product standard

EN 62560: 2010 Self-ballasted LED-lamps for general lighting services by voltage 50 V - Safety specifications

Page 3: EMC OSRAM

3/4 Form_EC_100316

EC-Declaration of Conformity Annex Document-No.: 2010 / QT_ENDURA_01

The conformity of the designated product(s) with the provisions of the European Directive 2004/108/EC is given by the compliance with the following European Standard(s). The latest

amendment applies, even if not mentioned below.

EN 55015: 2006 + A1:2007 + A2:2009

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

EN 61000-3-2: 2006

Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits for harmonic current emissions (equipment input current 16 A per phase)

EN 61000-3-3: 2008

Electromagnetic compatibility (EMC) — Part 3-3: Limits — Limitation of voltage changes, voltage fluctuations and flicker in public low voltage supply systems, for equipment with rated current 16 A per phase and not subjected to conditional connection

EN 61547: 1995+A1:2000

Equipment for general lighting purposes — EMC immunity requirements

The conformity of the designated product(s) with the provisions of the European Directive 2000/55/EC is given by the compliance with the following European Standard(s):

EN 50294: 1998 +A1:2001 +A2:2003

Measurement method of total input power of ballast-lamp circuits

Page 4: EMC OSRAM

4/4 Form_EC_100316

EC-Declaration of Conformity Attached list Document-No.: 2010 / QT_ENDURA_01

QT ENDURA 70-100/120-240 S

QT ENDURA 100-150/120-240 S

Page 5: EMC OSRAM
Page 6: EMC OSRAM
Page 7: EMC OSRAM
Page 8: EMC OSRAM
Page 9: EMC OSRAM
Page 10: EMC OSRAM
Page 11: EMC OSRAM
Page 12: EMC OSRAM
Page 13: EMC OSRAM
Page 14: EMC OSRAM
Page 15: EMC OSRAM

QUICKTRONIC ENDURA ECG for OSRAM ENDURA QT ENDURA 70-100/120-240 S QT ENDURA 100-150/120-240 S Product features: Can be used for luminaires protection class I and II (with functional earth) 60.000 hours lifetime with 10% max. failure rate at tc = tc max. Reliable lamp ignition between -40°C...+50°C (-25°C…+40°C for 70W lamp) Overheating protection Suitable for emergency installations (DC operation)

Technical data: Reference: QT ENDURA 70-100 QT ENDURA 100-150 Lamp: ENDURA 70 ENDURA 100 ENDURA 100 ENDURA 150 Lamp wattage at 230 V [W] 70 100 100 150 System wattage 230 V [W] 82 107 146 157 Line current 230 V [A] 0.34 0.44 0.66 0.67 Luminous flux at 25°C [lm] 6500 8000 11000 12000 Starting time: t: < 0.5 sec. Line voltage: 120 V - 240 V Voltage range (AC): 108 V - 264 V Voltage range (DC): 176 V – 275 V; for lamp ignition min. 198 V Line frequency: 0/50-60 Hz Operating frequency: 250 kHz Power factor: 0,95 Ambient temperature ta: -25°C to +50°C -40°C to +50°C -40°C to +50°C -40°C to +50°C Measuring point temperature tc: max. +65°C max. +70°C Dimensions (l x w x h): 181 mm x 100 mm x 43 mm Distance mounting holes: 170 mm 170 mm Weight: 860 g 860 g Max. wiring length ECG/lamp up to 25 m 1) Safety: acc. to EN 61347-2-3 / IEC 61347-2-3 Radio interference: acc. to EN 55015 / CISPR 15 Harmonic content: acc. to EN 61000-3-2 / IEC 61000-3-2 Immunity: acc. to EN 61547 / IEC 61547 Packaging unit: 5 pieces

Approval marks:

1) for remote mounting special wiring requirements are necessary

Technical Information Edition: October 2006 subject to change

Page 16: EMC OSRAM

QUICKTRONIC ENDURA ECG for OSRAM ENDURA QT ENDURA 70-100/120-240 S QT ENDURA 100-150/120-240 S Product number: Product number EAN 10 / Single unit (1 pc.) EAN 40 / Package unit (5 pcs.) QT ENDURA 70-100/120-240 S 4050300 804668 4050300 804675 QT ENDURA 100-150/120-240 S 4050300 662589 4050300 662596

Product dimensions:

160

181

170

49

100

43

Technical Information Edition: October 2006 subject to change