Top Banner
Electronics
64
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Electronics

Electronics

Page 2: Electronics

Industrial EngineeringSince we began, HYDAC has been involved inmany industrial engineering applications. Ourknowledge and expertise of many industriesprovides a comprehensive range of versatilehydraulic components. HYDAC offers customsolutions for machine tools, plastic injectionmolding machines, test equipment, presses, andwelding robots. Other industrial applicationsinclude: steel and heavy industry, power transmissions, and paper mills.

About HYDACHYDAC stands for worldwide presence and accessibility to the customer. HYDAC has over 1000 distributorsworldwide and more than 30 wholly owned branches. HYDAC has been active in the field of pressure monitoringfor more than 20 years and has become one of the leaders in innovative pressure monitoring in hydraulics andpneumatics. Our know-how has evolved primarily from solving customers’ problems, combined with the extensiveexperience of the whole HYDAC group.

Energy and Environmental TechnologyHYDAC Electronics have played a key role in providing innovative developments in hydroelectric,heating, wind, and waste power plants. HYDAChas vast expertise in solvent and waste water processing technologies.

Mobile MarketThe aim of our engineers has always been to reducevolume and weight, resulting in increased product performance. HYDAC provides compact high performance components for the Mobile Market,which can be found in construction, forestry, andagricultural equipment.

Process TechnologyThe core products of HYDAC process technologyare electronics, filters, and filtration systems for theindustrial and environmental processing industries.HYDAC products are found in chemical, petro-chemical, and plastics industries. Also, paper anddye production, foundries, steel manufacturing, andpower plants.

Offshore Shipbuilding and Marine TechnologyMaritime technology places special demands onmaterial functionality and reliability. HYDACproducts meet these demands due to our highquality and test standards. HYDAC products havebeen applied under the toughest conditions fromdrilling rigs to deep sea applications.

HYDAC ProductsOur product range extends from simple pressure transmitters to theintelligent multiple pressure switches with customized software. Inthe field of sensors, we employ different techniques, enabling us tooffer the most appropriate solution to a customer’s specific application.

HYDAC Customer ServiceOur internal staff and worldwide distribution network take care ofthe important matter of customer service. HYDAC values highstandards, professional ethics, and mutual respect in all transactionswith customers, vendors, and employees. We invest in our relationshipsby providing expertise, quality, dependability, and accessibility tofoster growth and a sense of partnership. Our customer servicerepresentatives are committed to serving the customers’ needs.

HYDAC QualityHYDAC stands for quality and customer satisfaction. We are certifiedto ISO 9001 and can supply our products with certification ifrequired. To ensure that our products are as innovative as possible,they are developed, manufactured, and tested by qualified personnelusing advanced technology.

Page 3: Electronics

IntroductionISO Certified / Common Terms.............1Symbols / Approvals.............................2

Pressure SwitchesEDS 300 Series ...................................23EDS 300 Series

Shipbuilding and Offshore ..........25EDS 410 Series ...................................27EDS 505 Series ...................................29EDS 601 Series ...................................31EDS 710 Series ...................................33EDS 1700 Series .................................35EDS 3000 Series .................................37

AccessoriesTFP 100 & Safety Sleeve ....................55TestPoints............................................55Connectors..........................................56Adapters..............................................57Mounting Kits......................................58Demonstration Kits .............................59

DiagnosticsHMG 2020 Series................................49SMZ 1000 Series ................................53HMG Deluxe Diagnostic Kit ................60

Flow SensorsEVS 3100/3110 Series ........................47

Temperature TransducersETS 4000 Series..................................39ETS 7000 Series .................................41

Display UnitsHDA 6000 Series.................................21

Special Environment TransducersHDA 3000 Series - CAN Bus ..............11HDA 3400/3700 Series

Shipbuilding and Offshore..........13HDA 3700 Series

Hazardous Locations..................15HDA 3700 Series

Intrinsically Safe..........................17HDA 3800 Series

Steel Works.................................19

Pressure TransducersHDA 3700/3800 Series..........................3HDA 4400/4700 Series .........................5HDA 4100/4300 Series .........................7HDA 7000 Series...................................9

Temperature SwitchesETS 300 Series....................................43ETS 1700 Series..................................45

Table of Contents

Page 4: Electronics

Accuracy - the error ratio of the full scale output or the error ratio of the output expressed in %Ambient Conditions - conditions of the medium surrounding the transducer (pressure, temperature, etc...)Best Fit Straight Line (BFSL) - an average of the deviation of all calibration pointsExcitation - the external power supply applied to a device for its proper operationEMI Susceptibility - the level or degree to which a device is vulnerable to electromagnetic interferenceFull Scale (FS) - relative to the full measuring rangeHysteresis - the maximum difference in electrical output at any pressure value within the specified range between

an increasing and decreasing cycleLinearity - the closeness of a calibration curve to a specified straight linePressure - force per unit of area exerted by a fluid at some point in the systemRepeatability - the ability of a transducer to reproduce outputTemperature Range (Operating) - the interval of temperatures in which the transducer is intended to be used

Electronics Catalog

ISO Certified / Common Terms

1

ISO Certified:

Common Terms:

HYDAC has become a leader in hydraulicsand pneumatics. We have earned that roleby emphasizing quality, innovation, andexcellence in everything we manufacture.HYDAC is committed to maintaining thosehigh standards of quality and service inaccordance with the ISO 9001International Standard.

PLEASE NOTE:

Certain combinations are subject to availability and/or approval. There may be a minimum quantity required for certain combinations.Requirements will be determined at time of inquiry or purchase order. Alternatives may be suggested by product management.

Specifications and dimensions given in this catalog represent engineering configurations at the time of printing.

Modifications may take place and product materials are subject to change without prior notice.

Page 5: Electronics

Electronics Catalog 21-877-GO HYDAC

Symbols / Approvals

Approvals:

Symbols:

Gearboxes

Agricultural

Pulp & Paper

Steel / Heavy Industrial

Industrial

Railways

Construction

Power Generation

Shipbuilding

Offshore

Page 6: Electronics

Approvals:

Electronics Catalog

Pressure Transducers

3

HDA 3700 & 3800About HDA 3700 & 3800 Pressure Transducers:The HDA 3000 family of transducers is designed to provide exceptional durabilityand accuracy in demanding industrial and mobile applications. They are used toconvert hydraulic or pneumatic pressure into an electrical output signal linearlyproportional to the input pressure. The signals can be sent to most commonlyused processors and controllers, including PLC's, computers, recorders, anddigital displays. Frequently, HDA 3000's are packaged with HYDAC digital displays,such as the HDA 5000 or HDA 6000, to monitor, regulate, or control processesin hydraulic or pneumatic systems.

Technical Details: Applications:

Special models on request.

Input Data HDA 3700 HDA 3800

Measuring ranges 6, 16, 60, 100, 6, 16, 60, 100, 250, 400, 600 bar 250, 400, 600 bar

Overload pressure 200% FS, maximum 900 bar 200% FS, maximum 900 barBurst pressure 300% FS 300% FS

Mechanical Connection G 1/4 A DIN 3852 G 1/4 A DIN 3852SAE 6 9/16-18 UNF2A male SAE 6 9/16-18 UNF2A male

(with adapter) (with adapter)

Tightening torque 15 lb-ft (20 Nm) 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, FPM seal Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity, ≤ ±0.25 %FS max ≤ ±0.15 %FS maxhysteresis, and repeatabilityTemperature compensation ≤ ±0.0045%FS/°F typ. ≤ ±0.003%FS/°F typ.zero point ≤ ±0.0085%FS/°F max. ≤ ±0.006%FS/°F max.Temperature compensation ≤ ±0.0045%FS/°F typ. ≤ ±0.003%FS/°F typ.over range ≤ ±0.0085%FS/°F max. ≤ ±0.006%FS/°F max.Rise time approx. 0.5 ms approx. 0.5 msLong-term drift ≤ ±0.1%FS typ. / year ≤ ±0.1%FS typ. / yearAmbient ConditionsNominal temperature range -13 to +185°F (-25° to +85 °C) -13 to +185°F (-25° to +85 °C)Operating temperature range -40 to +185°F (-40° to +85 °C) -40 to +185°F (-40° to +85 °C)Storage temperature range -40 to +212°F (-40° to +100 °C) -40 to +212°F (-40° to +100 °C)Fluid temperature range -40 to +212°F (-40° to +100 °C) -40 to +212°F (-40° to +100 °C)

mark EN 50081-1, EN 50081-2 EN 50081-1, EN 50081-2EN 50082-1, EN 50082-2 EN 50082-1, EN 50082-2

Vibration resistance to ≤ 20g (196.2 m/s2) ≤ 20g (196.2 m/s2)IEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 65 IP 65 Other dataSupply voltage 2-conductor 10 to 30 VDC 10 to 30 VDCSupply voltage 3-conductor 12 to 30 VDC 12 to 30 VDCResidual ripple supply voltage ≤ 5% ≤ 5%Current consumption 3-conductor approx. 15 mA approx. 15 mAReverse polarity protection of the supply voltage, excess voltage, standard standardoverride and short circuit protectionLife expectancy 10 million load cycles, 10 million load cycles,

0 to 100%FS 0 to 100%FSWeight approx. 180 g approx. 180 g

Page 7: Electronics

HDA 3 X X X - X - XXX - 000.Series

HDA 3 = 3000 series Pressure TransducerAccuracy

7 = 0.25% B.F.S.L.8 = 0.15% B.F.S.L.

Mechanical Connection4 = G 1/4 A DIN 38527 = SAE 6 9/16-18 UNF2A male supplied with adapter*

Electrical Connection4 = 4 pole Binder plug 714 Mx18 (connector not included)5 = DIN43650/ISO4400 plug, 3 pole + ground (connector ZBE 01 included)

Output SignalA = 2 conductor, 4-20 mAB = 3 conductor, 0-10 VDCE = 3 conductor, 0-20 mA, sourcing

Pressure Range006 = 87 psi (6 bar)* 250 = 3625 psi (250 bar)*016 = 232 psi (16 bar)* 400 = 5800 psi (400 bar)*060 = 870 psi (60 bar)* 600 = 8700 psi (600 bar)*100 = 1450 psi (100 bar)*

Modification Number000 = Standard

* Adapter is included to convert G1/4 Male to SAE-6 Male connection on some models

Electronics Catalog 41-877-GO HYDAC

Model Code:

Dimensions:

Circuit Connection: Plug Connection:

1+ Supply

0V

Free

RL

RL

2

3HDA-3XX5-A

1

+ Supply10 to 30V

0V

Free

Free

RL

RL

2

3HDA-3XX4-A

1+ Supply

0V

Free

2

3V

Signal0 to 10VHDA-3XX5-B

1+ Supply12 to 30V

0V

Free

2

3V

Signal0 to 10VHDA-3XX4-B

1+ Supply

0V

Free

2

3

RLSignal

0 to 20mAHDA-3XX5-E

1+ Supply12 to 30V

0V

Free

2

3

RLSignal

0 to 20mAHDA-3XX4-E

Two Conductor Output: Max. Load = Supply - 10V (Ω)0.02 Amp

HDA 3XX5 use with ZBE 01 (see page 56)

HDA 3XX4 use with ZBE 02 or ZBE 03(see page 56)

Three Conductor Output: Min. Load = 2k (Ω)

Three Conductor Output: Max. Load = Supply - 7V (Ω)0.02 Amp

3.33"(84.5 mm)

ø 1.06"(27 mm) 1.34"

(34 mm)

1.61"(41 mm)

1.10"(28 mm)

0.31"(8 mm)0.47"

(12 mm)

G 1/4

1.06" Hexbetween flats

1

2 3

4

1 23

Page 8: Electronics

Approvals:

Technical Details: Applications:

About HDA 4400 & 4700 Pressure Transducers:Series HDA 4000 transducers are compact, heavy-duty, pressure instrumentsdesigned for both OEM industrial and off-road applications where accuracy,repeatability, and stability can not be compromised. This series utilizes a shockresistant thin film sensor as the pressure to electrical conversion element. Thinfilm technology is used because it maintains its accuracy over a wide temperaturerange, extreme dynamic conditions, and hostile environments. When combinedwith a proprietary amplification circuit, its typical accuracy class is ≤ ± 0.5% or≤ ± 0.25% BFSL. Wetted metal parts are corrosion resistant stainless steel. It isavailable in eight pressure ranges from 150 psi up to 9000 psi. It is protectedfrom extreme EMI emissions and can be applied in critical closed loop operatingsystems. It carries the mark and is designed and manufactured to ISO 9001Quality System requirements.

HDA 4400 & 4700

Electronics Catalog

Pressure Transducers

5

Special models on request.

Input Data HDA 4400 HDA 4700

Measuring ranges 150, 750, 1000, 1500, 3000, 150, 750, 1000, 1500, 3000, 5000, 6000, 9000 psi 5000, 6000, 9000 psi

Overload pressure 150% FS, maximal 13000 psi 200% FS, maximal 13000 psiBurst pressure 300% FS 300% FSMechanical Connection SAE 6 9/16-18 UNF2A male SAE 6 9/16-18 UNF2A maleTightening torque approx. 15 lb-ft (20 Nm) approx. 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, FPM seal Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ≤ ±0.5 %FS max ≤ ±0.25 %FS max

Temperature compensation ≤ ±0.0085%FS/°F typ. ≤ ±0.0045%FS/°F typ.zero point ≤ ±0.014%FS/°F max. ≤ ±0.0085%FS/°F max.Temperature compensation ≤ ±0.0085%FS/°F typ. ≤ ±0.0045%FS/°F typ.over range ≤ ±0.014%FS/°F max. ≤ ±0.0085%FS/°F max.Rise time approx. 1 ms approx. 0.5 msLong-term drift ≤ ±0.3%FS typ. / year ≤ ±0.1%FS typ. / yearAmbient ConditionsNominal temperature range 32 to +158°F (0 to +70 °C) -13 to +185°F (-25 to +85 °C)Operating temperature range -13 to +185°F (-25 to +85 °C) -40 to +185°F (-40 to +85 °C)Storage temperature range -40 to +212°F (-40 to +100 °C) -40 to +212°F (-40 to +100 °C)Fluid temperature range -40 to +212°F (-40 to +100 °C) -40 to +212°F (-40 to +100 °C)

mark EN 50081-1, EN 50081-2 EN 50081-1, EN 50081-2EN 50082-1, EN 50082-2 EN 50082-1, EN 50082-2

Vibration resistance to ≤ 20g (196.2 m/s2) ≤ 20g (196.2 m/s2)IEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 65 IP 65 Other dataSupply voltage 2-conductor 10 to 30 VDC 10 to 30 VDCSupply voltage 3-conductor 12 to 30 VDC 12 to 30 VDCResidual ripple supply voltage ≤ 5% ≤ 5%Current consumption 3-conductor approx. 25 mA approx. 25 mAReverse polarity protection of the supply voltage, excess voltage, standard standardoverride and short circuit protectionLife expectancy > 10 million load cycles > 10 million load cycles

0 to 100%FS 0 to 100%FSWeight approx. 145 g approx. 145 g

Page 9: Electronics

free

0V

+supply

signal

12

34

HDA 4X74-B

RL

RL0V

+supply

V

free

free12

34

HDA 4X74-B

Three-Conductor 0 to 10 VDCRLmin = 2k

Electronics Catalog 61-877-GO HYDAC

Model Code:

X

Dimension X: with right angled plug ZB 03 ≈ 4.252" (108mm)Dimension X: with straight plug ZB 02 ≈ 5.0" (127mm)

1.181"(30 mm)SAE 6

Hex SW 1.063"(27mm)

2.244"(57mm)

S

ø 1.26"(32 mm)

HDA 4474/4774, illustrated with ZBE 03

1.378"(35 mm)

3.642"(92.5 mm)

SAE 6

Hex SW 1.063"(27mm)

2.244"(57mm)

ø 1.378"(35 mm)

HDA 4475/4775, illustrated with ZBE 01

RL

RL

0V

+supply

0V

+supply

signal

12

34

12

34

free

free

HDA4X75-A

HDA4X75-B V

Three-Conductor 0 to 10 VDCRLmin = 2k

HDA 4 X 7 X - X - XXXX - 000Series

HDA 4 = 4000 series Pressure Transducer

Accuracy4 = 0.5% BFSL7 = 0.25% BFSL

Mechanical Connection7 = SAE 6 9/16-18 UNF2A male

Electrical Connection4 = 4 pole Binder plug 714 Mx18 (connector not included)5 = DIN 43650/ISO 4400 plug, 3 pole + ground (connector ZBE 01 included)

Output SignalA = 2 conductor, 4-20 mAB = 3 conductor, 0-10 VDC

Pressure Range0150 = 150 psi (10 bar) 3000 = 3000 psi (207 bar)0750 = 750 psi (52 bar) 5000 = 5000 psi (345 bar)1000 = 1000 psi (69 bar) 6000 = 6000 psi (413 bar)1500 = 1500 psi (103 bar) 9000 = 9000 psi (620 bar)

Modification Number000 = Standard

Dimensions:

Circuit Connection: Plug Connection:HDA4X74 use with ZBE 01 (see page 56)

HDA4X75 use with ZBE 02 or ZBE 03 (see page 56)

1

2 3

4

1 23

Page 10: Electronics

Approvals:

Electronics Catalog

Pressure Transducers

7

HDA 4100 & 4300About HDA 4100 & 4300 Pressure Transducers:The HDA 4100 & 4300 is similar in design to our HDA 4400 series. This transducerutilizes a ceramic sensor element to provide our customers a low cost, lowpressure sensor while maintaining accuracy, repeatability, and stability. Thebody is a brass/steel combination but is available in an all steel version. Pressureranges from 0 to 15 psi up to 1500 psi are available. A number of port sizes andelectrical connection combinations make this an attractive and affordable solutionto your low pressure needs.

Technical Details: Applications:Input Data

Measurement range 0 to 15, 50 psi (A)0 to 15, 30, 50, 100, 150, 250, 500 psi (G)

Overload pressure 200%FSBurst pressure 300%FSMechanical connection 1/4”-18 NPT maleParts in contact with media Brass, FPM seal, ceramicOutput dataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ≤ ±0.5 %FS max.

Temperature compensation ≤ ±0.012%/°F typ.Zero point ≤ ±0.017%/°F max.Temperature compensation ≤ ±0.012%/°F typ.over range ≤ ±0.017%/°F max.Rise time approx. 2 msLong-term drift ≤ ±0.3%FStyp. / yearAmbient ConditionsNominal temperature range 32° to 176°F (0° to 80˚C)Operating temperature range -13° to 185°F (-25° to 85˚C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1, EN 50081-2EN 50082-1, EN 50082-2

Vibration resistance to IEC 68-2-6 at 10 to 500Hz ≤ 20 g (196,2 m/s2)

Safety type to DIN 40050 IP 65 (DIN 43650 connector)IP 67 (ZBE 06 molded cable)

Other DataSupply voltage 2-conductor 10 to 30 V DCSupply voltage 3-conductor 12 to 30 V DCResidual ripple supply voltage ≤ 5 %Current consumption 3-conductor approx. 25 mAReverse polarity protection of the supplyvoltage, excess voltage, override and standardshort circuit protectionLife expectancy >10 million load cycles (0 to 100%FS)Weight approx. 145 g

Page 11: Electronics

1.378"(35 mm)

3.71"(94 mm)

1/4 NPT

Hex SW 1.06"(27mm)

2.37"(60mm)

ø 1.26"(32 mm)

free

RL

RL

0V

+supply

signal

0V

+supply

12

34

12

34

free

HDA 4X85-B V

HDA 4X85-A

RL

RL

0V

+supply

0V

+supply

signal

12

34

12

3

4

free

free

free

V

Three-Conductor 0 to 10 VDCRLmin = 2k

Three-Conductor 0 to 10 VDCRLmin = 2k

HDA 4X86-B

HDA 4X86-A

Electronics Catalog 81-877-GO HYDAC

Dimensions:The body is brass (stainless steel available on request)

Model Code:

Circuit Connection: Plug Connection:

HDA 4 X X X - X - XXXX - 000Series

HDA 4 = 4000 series Pressure Transducer

Accuracy1 = Absolute (ceramic) 0.5% BFSL3 = Gauge (ceramic) 0.5% BFSL

Mechanical Connection8 = 1/4” - 18 NPT male thread

Electrical Connection5 = DIN 43650/ISO 4400 plug, 3 pole + ground (connector ZBE 01 included)6 = M12x1 plug, 4-pole (connector not included)

Output SignalA = 2 conductor, 4-20 mAB = 3 conductor, 0-10 VDC

Pressure RangeAbsolute Gauge0015 = 0 to 15 psi 0015 = 0 to 15 psi0050 = 0 to 50 psi 0030 = 0 to 30 psi

0050 = 0 to 50 psi0100 = 0 to 100 psi0150 = 0 to 150 psi0250 = 0 to 250 psi0500 = 0 to 500 psi

Modification Number000 = Standard

HDA 4X65 use with ZBE 01(see page 56)

HDA 4X66 use with ZBE 06(see page 56)

1 23

1 2

34

Page 12: Electronics

Applications:

Approvals:

Technical Details:

HDA 7000

Electronics Catalog

Pressure Transducers

9

About HDA 7000 Pressure Transducers:The pressure transducer series HDA 7000 combines excellent technical specificationswith a very compact design.The HDA 7000 was specifically developed for severe applications e.g. mobile applications.A thin film sensor cell is the basis for a robust, long-life pressure transmitter.Various pressure ranges between 0 to 150 psi and 0 to 9000 psi facilitate adaptationto the particular application.For integration into modern controls (e.g. with PLC) different analog output signals,including 4 to 20 mA or 0 to 5 V, are available on the standard version. Ratio-metricoutput signals are also available on request.

Input Data

Measuring ranges 0 to 150, 750, 1000, 1500, 3000, 5000, 6000, 9000 psi

Overload pressure 150% FS, maximal 13000 psiBurst pressure 300% FSMechanical Connection SAE 6 9/16-18 UNF2A male,

G 1/4 A DIN 3852, SAE 4, 1/4” NPTTightening torque G 1/4, SAE 6 approx. 15 lb-ft (20 Nm)

SAE 4 approx. 11 lb-ft (15 Nm)Parts in contact with media Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ≤ ±0.5 %FS

Temperature compensation ≤ ±0.0085%FS/°Fzero point ≤ ±0.017%FS/°FTemperature compensation ≤ ±0.0085%FS/°Fover range ≤ ±0.017%FS/°FRise time approx. 1 msLong-term drift ≤ ±0.3%FS typ. / yearAmbient ConditionsNominal temperature range -13° to 185°F (-25° to 85°C)Operating temperature range -40° to 185°F (-40° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1, EN 50081-2 EN 50082-1, EN 50082-2

Vibration resistance to ≤ 20g (196.2 m/s2)IEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 67 (w/ ZBE 06 molded cable

or flying lead)Other dataReverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionLife expectancy ≥ 10 million load cycles 0 to 100%FSWeight (with M12 connector) approx. 48 g

Page 13: Electronics

Electronics Catalog 101-877-GO HYDAC

This is an OEM Product:Part number and Model Code are created with an order. A minimum order of 250 pieces will be expected from all OEMs. Thecustomer is to provide electrical connection, mechanical connection, and electrical output requirement. Choices to include butare not limited to:

Electrical Mechanical OutputM12x1 G 1/4 A DIN 3852 0 - 5 VDC

Flying lead SAE 4 - 7/16 4 to 20 mASAE 6 9/16-18 UNF2A male Ratio - metric

1/4” NPT 1 - 6 VDC0.5 - 4.5 VDC

Plug Connection:Circuit Connection:

(18.5mm)ø

0.728" (21mm)

ø 0.8.27"

M12x1

(52mm)2.047"

G 1/4A

hex-SW07486kt-SW19

Pressure connectionDIN3852

(18.5mm)ø

0.728"

(35.5mm)1.398"

0.078"(2mm)

(18.9mm)0.744"

SAE-69/16-18 UNF

hex-SW0748

0.394"(10.0mm)

Dimensions:

HDA 7000 use with ZBE 06 (see page 56)

RL

RL

RL

RL0V

+supplybrown

black

brown

red

black0V

+supply

signal

0V

+supply

0V

+supply

signal

12

34

12

3

4

free

free

free

4 to 20 mA

4 to 20 mA

0 to 5V1 to 6 V0.5 to 4.5 V

0 to 5 V1 to 6 V0.5 to 4.5 V

V

V

Flying Leads:

M12x1:

1 2

34

Page 14: Electronics

Applications:

Approvals:

Electronics Catalog

Specialty Pressure Transducers

11

HDA 3000 - CAN BusAbout HDA 3000 - CAN Bus Pressure Transducers:HYDAC has developed the HDA 3000 CAN-bus sensor to meet the needs ofthe marketplace for a field-bus sensor. There are several field-bus systems onthe market designed for specific industries. One of the most known in thehydraulic industry is the CAN-bus. The purpose of CAN-bus is to eliminate theneed for heavy cabling trees, particularly in the automotive and process industries.The HDA 3000 CAN-Bus sensors are interfaced by a pair of twisted wires whichenables a CAN system to receive, dispatch and monitor information fromhydraulic systems. CAN-bus is a relatively simple and uncomplicated system. Inthe hydraulic field there are applications for many mobile machine manufacturerssuch as excavators and tractors. Each CAN-bus sensor is custom designed forevery OEM to meet their individual system needs.

Technical Details:Input Data

Measuring ranges 0 to 150, 750, 1000, 1500, 3000, 5000, 6000, 9000 psi

Overload pressure 150% FS, maximal 13000 psiBurst pressure 300% FSMechanical Connection SAE 6 9/16-18 UNF2A maleTightening torque approx. 15 ft-lb (20 Nm)Parts in contact with media Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ≤ ±0.5 %FS

Temperature compensation ≤ ±0.0085%FS/°F max.zero pointTemperature compensation ≤ ±0.0085%FS/°F max.over rangeRise time approx. 1 msLong-term drift ≤ ±0.3%FS typ. / yearAmbient ConditionsNominal temperature range 32° to 158°F (0° to 70°C)Operating temperature range -13° to 185°F (-25° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1, EN 50081-2 EN 50082-1, EN 50082-2

Vibration resistance to ≤ 20g (196.2 m/s2)IEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 67 (M12x1 molded connector is used)

Other dataSupply voltage 18 to 32 V DCLife expectancy 10 million load cycles 0 to 100%FSWeight approx. 200 g

Page 15: Electronics

Electronics Catalog 121-877-GO HYDAC

What Are Field-Bus Systems?A field-bus system is a data network with the objective to receive data from a production process, exchange data betweendevices or machines, control steps or processes in production. Data transmission happens serially with digital signals(equivalent to Internet data transmission.)

The most basic design of such a data network is a 2-wire cable with various individual sensors (e.g. Pressure transmitters),actors (e.g. solenoid valves), controllers, periphery units, and control units (e.g. PLC, industrial PCs) connected at any point.BUS participants need a suitable interface, which transfers flow of data. Each individual component gets its own address.

Structure of a Bus System:

Remarks: Communication of process data is performed by means of every individual sensor, component, and so on,being connected via it’s own wiring to high layer control.

Advantages:• Easy wiring with clear reduction of cabling (best case: only two cables)

• Clear structure

• Diagnostic functions, connected units may be checked on functionality

• All system functions are available in high layer control at any time

• High level of transmission safety, information may be checked on validity through multiple transmissions

• Easy to be enlarged, since at any place of network a unit may be added

• Easy implementation into higher leveled systems:- connection to other bus system- distance diagnostic systems- service units

Node 1

Bus master

Node 2 Node 3 Node 30 Node 31

e.g. pressure transmitter

e.g. valve

e.g. PLC

e.g. temperature sensor

Page 16: Electronics

Approvals:

Technical Details:

HDA 3400 & 3700 - Shipbuilding and Offshore

Electronics Catalog

Specialty Pressure Transducers

13

About HDA 3400 Pressure Transducers:This pressure transmitter, which has been specially developed for shipbuilding andoffshore applications, is based on a very robust and accurate sensor cell with a thinfilm strain gauge on a stainless steel membrane.All parts in contact with the fluid are in stainless steel and are welded together.Since no seals are required in the sensor chamber, leakage is eliminated.The 4 to 20 mA output signal in two conductor technic enables connection to therelevant evaluation electronics. Since accuracy varies markedly with the tempera-ture of the fluid being measured, this instrument offers outstanding characteristicsin this respect.Areas of application are pressure monitoring on marine transmissions, dieselengines, pumps and general hydraulic and pneumatic systems.

Applications:

Bureau VeritasNo.: 10342 /A0 BV

American Bureau of ShippingNo.: 00-ES 19976-X

Lloyds Register of ShippingNo.: 00/20049

Det Norske VeritasNo.: A-7711 (892.10)

Germanischer LloydNo.: 15520-00HH

Input Data HDA 3400 HDA 3700Measuring ranges 16, 60, 100, 6, 16, 60, 100,

250, 400, 600 bar 250, 400, 600 barOverload pressure 200% FS, maximal 900 barBurst pressure 400% FSMechanical Connection G 1/4 A DIN 3852Tightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity, ≤ ±0.5%FS ≤ ±0.25%FShysteresis, and repeatabilityTemperature compensation ≤ ±0.0085%FS/°F typ. ≤ ±0.0045%FS/°F typ.zero point ≤ ±0.014%FS/°F max. ≤ ±0.0085%FS/°F max.Temperature compensation ≤ ±0.0085%FS/°F typ. ≤ ±0.0045%FS/°F typ.over range ≤ ±0.014%FS/°F max. ≤ ±0.0085%FS/°F max.Rise time approx. 1 msLong-term drift ≤ ±0.3%FS typ. / yearAmbient ConditionsNominal temperature range 32° to 158°F (0° to 70°C) -13° to 185°F (-25° to 85°C)Operating temperature range -13° to 185°F (-25° to 85°C) -40° to 185°F (-40° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance to 5 to 25 Hz: 3.2 mmIEC 68-2-6 at 10 to 500Hz 25 to 100 Hz: 4 gSafety type to DIN 40050 IP 65Other DataSupply voltage 10 to 30 VResidual ripple supply voltage ≤ 5%Current consumption 3-conductor approx. 25 mAReverse polarity protection of the supply voltage, excess voltage, availableoverride and short circuit protectionLife expectancy > 10 million load cycles 0 to 100%FSWeight approx. 145 g

Page 17: Electronics

Electronics Catalog 141-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

HDA 3 X 4 5 - A - XXX - S00

SeriesHDA3 = 3000 series Pressure Transducer for Shipbuilding & Offshore

Accuracy4 = 0.5% B.F.S.L.7 = 0.25% B.F.S.L.

Mechanical Connection4 = G 1/4 A DIN 3852

Electrical Connection5 = DIN 43650/ISO 4400 plug, 3 pole + ground (connector ZBE 01 included)

Signal TechnologyA = 2-conductor, 4 to 20 mA

Measuring Ranges006 = 6 bar (HDA 3700 only)016 = 16 bar060 = 60 bar100 = 100 bar250 = 250 bar400 = 400 bar600 = 600 bar

Modification NumberS00 = standard

Note: On units with a different modification number, please read the label or the technical amendment details supplied with the unit.All details are subject to technical modifications.

3.23"(82mm)

1.06"(27mm)

1.38"(35mm) 1.34"

(34mm)

1.97"(50mm)

0.47"(12mm)

G 1/4 AHex

SW27 0.74"(18.9mm)

0.08"(2mm)

øø

ø

RL max. = UB - 10 V [Ω]0.02 A

2-conductor 4 to 20 mA

RL

Free

1

2

3

RL

HDA3X45-A

Note: The load resistance RL is pro-duced by the measuring resistanceinside the evaluation unit and the lineresistance of the connection line.

HDA 3X45 use with ZBE 01 (see page 56)

1 23

Page 18: Electronics

Applications:

Approvals:

Electronics Catalog

Specialty Pressure Transducers

15

HDA 3700 - Hazardous LocationsAbout HDA 3700 Pressure Transducers:The pressure transducer series HDA 3700 is available in a version for measuringpressure in hazardous locations. This model is certified for use in Class I, Division 2,groups A, B, C, and D, along with Class II, Division 2, groups F and G hazardouslocations.The HDA 3700 family of transducers is designed to provide exceptional durability andaccuracy in demanding industrial and process applications. They are used to converthydraulic or pneumatic pressure into an electrical output signal linearly proportionalto the input pressure. The signals can be sent to most commonly used processorsand controllers, including PLC’s, computers, recorders, and digital displays.The pressure measured by the sensor is converted to a proportional, analog 4 to 20mA output signal. The signals can be sent to most commonly used processorsand controllers, including PLC's, computers, recorders, and digital displays.

Technical Details:Input DataMeasuring ranges on requestOverload pressure on requestBurst pressure on requestMechanical Connection SAE 6 9/16-18 UNF2A male

1/4”-18 NPT male thread1/4”-18 NPT female thread

Tightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ±0.25 %FS max

Temperature compensation ≤ ±0.0045%FS/°F typ.zero point ≤ ±0.0085%FS/°F max.Temperature compensation ≤ ±0.0045%FS/°F typ.over range ≤ ±0.0085%FS/°F max.Rise time approx. 0.5 msLong-term drift ≤ ±0.1%FS typ. / yearAmbient ConditionsNominal temperature range -13° to 185°F (-25° to 85˚C)Ambient temperature range -40° to 185°F (-40° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance to 196.2 m/s2 (≤ 20g)IEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 65Other DataApproval CL. I, Div. 2, GRPS. A,B,C, & D,

CL. II, Div. 2, GRPS. F & G,CSA Certification, FM approval

Supply voltage 12 to 28 V (max 1 W)Residual ripple supply voltage ≤ 5%Reverse polarity protection ofthe supply voltage, and short standardcircuit protectionLife expectancy > 10 million load cycles 0 to 100%FSWeight 180 g

Page 19: Electronics

HDA 3 7 X 8 - A - XXXX - C 00 (48 inch)Series

HDA3 = 3000 series Pressure Transducer for Hazardous Locations

Accuracy7 = 0.25% BFSL

Mechanical Connection7 = SAE-6 9/16-18 UNF2A male8 = 1/4”-18 NPT male threadF = 1/4”-18 NPT female thread

Electrical Connection8 = 1/2” NPT male conduit (wire leads)

SignalA = 4 to 20mA

Pressure Rangeson request

ApprovalC = CL. I, Div. 2, GRPS. A,B,C, & D, CL. II, Div. 2, GRPS. F & G, CSA Certification, FM approval

Modification Numberused for pin connection, special calibration in pressure range

Wire Length48 inch longer wires on request

Model Codes Containing RED are non-standard items - Minimum quantities may applyContact HYDAC for information and availability

Electronics Catalog 161-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection:

Hex SW1.063 Hex SW0.748

1/2 - 14 NPT

0.09"(2mm)

4.41"(112mm)

1.08"(27mm) 48"

(1219mm)

0.39"(10mm)

9/16-18UNF2A

0.75"ø (19mm)

1.16"ø (29mm)

O-ring 0.468 x 0.078FPM (Viton) - 90 shore

RL+ Supply

0VRL

HDA37X8-A

green

green/yellow

white

Page 20: Electronics

Electronics Catalog

Specialty Pressure Transducers

17

HDA 3700 - Intrinsically SafeAbout HDA 3700 Pressure Transducers:The pressure transducer series HDA 3700 is available in a version for intrinsicallysafe circuits for measuring pressure in hazardous applications. The safety class EEx ia IIC T6 covers nearly all requirements with regard to ignition group, error classand temperature class.Like the industrial version of the HDA 3700, the EX-version also has a very accurate,robust pressure sensor. With a basic accuracy of ≤ 0.25% BFSL and outstandingspecifications regarding the temperature effect, this series is suitable for use in awide range of applications. The pressure measured by the sensor is converted to aproportional, analog 4 to 20 mA signal. The signals can be sent to most common-ly used processors and controllers, including PLC's, computers, recorders, anddigital displays.

Technical Details: Safety Rating:

Applications: Approvals:

Input Data

Measuring ranges 6, 16, 60, 100,250, 400, 600 bar

Overload pressure 200% FS, maximal 900 barBurst pressure 300% FSMechanical Connection G 1/4 A DIN 3852Tightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, FPM sealOutput DataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ≤±0.25% FS max

Temperature compensation ≤ ±0.0045%FS/°Fzero point ≤ ±0.0085%FS/°FTemperature compensation ≤ ±0.0045%FS/°Fover range ≤ ±0.0085%FS/°FRise time approx. 0.5 msLong-term drift ≤ ±0.1%FS typ. / yearAmbient ConditionsNominal temperature range -13° to 140°F (-25° to 60°C)Operating temperature range -40° to 140°F (-40° to 60°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)Approval no. BVS 95.0.2030 EN 50014 and EN 50020Vibration resistance to 196.2 m/s2 (≤ 20g)IEC 68-2-6 at 10 to 500HzSafety type to DIN 40050 IP 65Other Data

Supply voltage 12 to 28 V (max 1W up to 26 V,max 0.8W for 26 - 28 V

Connection capacity ≤ 7 nFInductance 0HResidual ripple supply voltage ≤ 5%Reverse polarity protection of the standardsupply voltage, short circuit protectionLife expectancy > 10 million load cycles 0 to 100%FSWeight 180 g

EEx Component identification for use on applications with an explosion hazard,according to safety class definition.i Intrinsic safety: the circuits are designedso that no spark or thermal effect which canoccur under the test conditions stipulated inthe standard, can cause an ignition of a certainenvironment with an explosion hazard.a Error class “a” signifies that up to two independent errorscan occur on the component without this causing any danger. “a” is the highest possibleerror class. ‘b” is the lower level which allowsno more than 1 error on the component (i.e. if two errors occur) the safety is at risk.“a” specified components can be used in applications which only have “b” requirements.IIC “IIC” is the highest possible flash pointrange in the standard. “II” specifies the areaof application for all environments with anexplosion hazard, except for flame-proof protection. (Flame-proof protection is designatedby 1”)“C” designates the actual flash point range(i.e. the ignitability of the environment.) Class C isthe highest requirement, i.e. the environmentaccepted to be the most critical. The subordinateclasses A and B can be equipped with a “C”registered unit. “C” means, for example, thatgas mixtures with up to 23% of hydrogen willnot ignite.T6 Temperature class“T6” is the highest temperature class speci-fied in the standard which ensures that, at amaximum ambient temperature, the surfacetemperature never exceeds 85°C.Components of temperature class T6 can ofcourse also be used for lower classes T1 - T5.

Page 21: Electronics

Electronics Catalog 181-877-GO HYDAC

Dimensions:

Model Code:HDA 3 7 X X - A - 006 - E00

SeriesHDA 3 = 3000 series Intrinsically Safe Pressure Transducer

Accuracy7 = 0.25% BFSL

Mechanical Connection4 = G 1/4 A DIN 38525 = SAE-4 female thread (7/16”-20)7 = SAE-6 9/16-18 UNF2A male (with adapter)C = Autoclave female port (7/16”-20, for pressure ≥ 10k psi)F = 1/4”-18 NPT female thread

Electrical Connection4 = 4 pole Binder plug 714 M18x1 plug (connector not included)5 = DIN48650/ISO4400 plug, 3 pole + ground (connector ZBE 01 included)8 = 1/2” NPT male conduit

Output SignalA = 2-conductor / 4 to 20mA

Pressure Ranges006, 016, 060, 100, 250, 400, 600 bar (available in psi)

Modification NumberE00 = Safety Class EEx ia IIC T6

Model Codes Containing RED are non-standard items - Minimum quantities may applyContact HYDAC for information and availability

3.33"(84.5 mm)

ø 1.06"(27 mm) 1.34"

(34 mm)

1.61"(41 mm)

1.10"(28 mm)

0.31"(8 mm)0.47"

(12 mm)

G 1/4

1.06" Hexbetween flats

Circuit Connection:

1+ Supply

0V

Free

RL

RL

2

3HDA3745-A

+ Supply

0V

RL

RL

1

4Free

2

3

Free

HDA3744-A

Plug Connection:

1/2” NPT male conduit:consult factory for availability

HDA 37X5 use with ZBE 01 (see page 56)

HDA 37X4 use with ZBE 02 or ZBE 03(see page 56)

1

2 3

4

1 23

Page 22: Electronics

Applications:

Approvals:

Electronics Catalog

Specialty Pressure Transducers

19

HDA 3800 - Steel WorksAbout HDA 3800 Pressure Transducers:This high-precision pressure transducer has been specially developed and adaptedfor the sophisticated measurement demands of steelworks technology. The unit hasa very robust sensor cell with a thin-film DMS which is applied to a stainless steelmembrane. It’s outstanding specifications with reference to temperature effect (temperature drift for zero point and range are at maximum ≤ ± 0.01 FS/°C each) and accuracy(≤ ± 0.15% FS typ.) makes it ideally suited for use in the harsh ambient conditionsfound in steelworks. The excellent EMC characteristics guarantee signal stabilityduring the harshest high-frequency, electro-magnetic interference.

Technical Details:

Note: F.S. (Full Scale) = Relative to the full measuring range * = Other measuring ranges on request

Input DataMeasuring ranges 350 barOverload pressure 900 barBurst pressure 2000 barMechanical Connection G1/4 A DIN 3852, G1/2 A male

SAE 6 9/16-18 UNF2A male

Tightening torque approx. 15 lb-ft (20 Nm) for G1/4 Aapprox. 33 lb-ft (45 Nm) for G1/2 A

Parts in contact with media Stainless steel, FPM seal (G1/4 A) NBR O-ring (G 1/2 A)

Output DataAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ≤ ±0.15 %FS max.

Temperature compensation ≤ ±0.0028%FS/°F typ.zero point ≤ ±0.056%FS/°F max.Temperature compensation ≤ ±0.0028%FS/°F typ.over range ≤ ±0.056%FS/°F max.Rise time ≤ 1.5 msLong-term drift ≤ ±0.1%FS typ. / yearAmbient ConditionsNominal temperature range -13° to 185°F (-25° to 85˚C)Operating temperature range -40° to 185°F (-40° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance toIEC 68-2-6 at 10 to 500Hz ≤ 25 g

Safety type to DIN 40050 IP 68Other DataSupply voltage 2 conductor - 10 to 30 V

3 conductor - 12 to 30 VResidual ripple supply voltage ≤ 5%Current consumption 3-conductor approx. 25 mAReverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionLife expectancy ≥ 10 million load cycles, 0 to 100%FSWeight 210 g

Page 23: Electronics

Electronics Catalog 201-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

0.31"(8mm)

4.13"(105mm)

3.23"(82mm)

6 m(fully extended

cord length)

Hex1.17"

(29.6mm)

ø0.74"(18.9mm)

G1/4 A

0.08"(2mm)

ø1.18"(30mm)

ø1.06"(27mm)cable gland

pg 7

6 m(fully extended

cord length)

G1/2 A

0.31"(8mm)

4.13"(105mm)

3.23"(82mm)

Hex1.17"

(29.6mm

ø1.06"(26.9mm)

0.12"(3mm)

ø1.18"(30mm)

ø1.06"(27mm)cable gland

pg 7

HDA 38 X 0 - X - 350 - 124Series

HDA 38 = Pressure Transducer for Steel Works

Mechanical Connection0 = G 1/2 A male thread4 = G 1/4 A DIN 38527 = SAE 6 9/16-18 UNF2A male

Electrical Connection0 = flying lead 6m (Teflon cable, silicon-free)

Signal TechnologyA = 2 conductor, 4-20 mAE = 3 conductor, 0-20 mA

Pressure Range350 = 350 bar (5075 psi)

Modification Number124 (determined by manufacturer)

Note: PSI pressures on request— Contact HYDAC for availability

brown

blue

RL

RL

UB

0V

HDA38xx-A

brown

black

blue

RL

UB

0V

HDA38xx-ESignal

RLmax. = UB - 7 V

[Ω] 0.02 A

RLmax. = UB - 10 V

[Ω] 0.02 A

3 conductor 0 to 20 mA2 conductor 4 to 20 mA

Note: The load resistance RL is produced by the measuring resistance inside the evaluation unitand the line resistance of the connection line.UB = + supply voltage

A-SignalBrown: + SupplyBlue: 0V

E-SignalBlack: + SupplyBrown: SignalBlue: 0V

Page 24: Electronics

Applications:

Approvals:

Housing Control panel module housing 48 x 96 mmControl panel cut out 45 x91Max. front panel thickness 23 mmDepth max. 200 mm

Supply voltage 115/230 V AC ±10%50 - 60 Hz24 V DC option (20.4 to 31.4)Residual ripple max. 2 Vpp

Power consumption 15 VA at 115/230 VFuse rating 0.32 AM at 115 VFuse rating 0.16 AM at 230 VFuse rating 0.8 AT 24 V DC

Supply sensor 1 and 2 ± 12 V max. ±20 mA per sensorInput sensor 1 and 2 4 to 20 mA input resistance approx. 160 Ω

Overload protection via PTC(positive temperature coefficient) connected in series0 to 10 V input resistance approx. 30 kΩ

Input sensor 3 0 to 10 V input resistance approx. 45 kΩInterrogation rate of sensor 16 ms, 4 ms for peak valuesError recognition Error report if sensor current < 3.5 mA

Error output against 0 V (during standard operation 2 Hz pulse, 12 V pp)

Reset peak value Level for “Reset” = 7.5 to 15 V, 12 V nominalOutput sensor 1 0 to 10 V load resistance ≥ 2 kΩRS 232 C interface Signal according to RS 232 C

adjustable Baud rate 300 - 96001 start bit, 1 stop bit, no parity8 data bits

Relay output Mechanical service life of contact 107 cyclesSwitching capacity: 30 W / 50 VASwitching voltage: 24 V DC / 50 V ACSwitching current: 0.01 mA to 3 A

Connections Power supply via cable (length 1.5 meters)at the back, with main plug to Euro standardSignals via double pin terminal plug at the back,max. cable diameter 1.5mm

Temperature effects Permissible ambient temperature 273 K to 323 K (0 to 50°)Temp. variation of zero point 0.12% / 10 K typ.Temp. variation of sensitivity 0.2% / 10 K typ.

markWeight 800 g

Electronics Catalog

Display Units

21

HDA 6000About HDA 6000 Intelligent Display Unit:The HDA 6000 is a microprocessor controlled display and control unit in standardcontrol panel module housing. A single-chip microprocessor controls all functions.A maximum of 3 analog inputs and 1 analog output is possible. The analog inputsignals are converted by a 10 bit A/D converter and displayed according to themeasuring scale selected by the user. Each of the 4 maximum possible relayscan be allocated to each of the 3 analog sensor inputs or the differentialbetween sensor signals 1 and 2. All operating parameters such as switchingpoints and switch-back (i.e. hysteresis) points can be programmed by means ofthe MODE and SET keys. The relays switch as soon as a pre-set switching pointis reached, or after a programmed delay. This function suppresses the reactionof the relays to short-term and irrelevant variations such as pressure spikes.

Technical Details:

Note: During switching of inductive loads, a protection diode (DC voltage) ora varistor (AC voltage) must be connected parallel to the load.

Page 25: Electronics

Electronics Catalog 221-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

HDA 6000

SET1 2 3 4MODE

ELECTRONIC

0.55"(14mm)

3.78"(96mm)

4.41"(112mm)

1.89"(48mm)

max. front panel thickness 0.91" (23 mm)

mounting frame

0.20"(5mm)

5.75"(146mm)

7.09"(180mm)

1.67"(42.5mm)

min.

HDA 6000 - X - XXX - 000Series

Series = HDA 6000Sensor inputs

0 = 1 sensor (4 to 20 mA), 2 relay outputs1 = 3 sensors (2 x 4 to 20 mA, 1 x 0 to 10 V), 4 relay outputs2 = 3 sensors (3 x 0 to 10 V), 4 relay outputs

Supply voltage115 = 115 V / 50 - 60 Hz230 = 230 V / 50 - 60 Hz024 = 24 V DC

Modification number000 = standard

HDA 3000-D

pressure sensorthree-conductor

A

+sensor 1

HDA 3000-D

pressure sensorthree-conductor

A

+sensor 2

with built-inpower supply

+

sensor 3

0 V

I = 4 to 20 mA

I = 4 to 20 mA

0 to 10 V

0 to 10 Vremote display

of sensor 1

1

2

3

11

4

12

5

6

7

8

9

17

18

19

20

16

15

S1*

load 1

varistorU

load 2

varistorU

load 3

varistorU

load 4

varistorU

auxillary voltagefor load 1 -4

depending on auxillary voltageand load: add external varistor

+12 V

–12 V

sensor 1 signal 4 to 20 mA

sensor 2 signal 4 to 20 mA

HDA 3000-A

pressure sensortwo-conductor

+

sensor 1

HDA 3000-A

pressure sensortwo-conductor

+

sensor 2

I = 4 to 20 mA

I = 4 to 20 mA

1

2

3

11

+12 V

–12 V

sensor 1 signal 4 to 20 mA

sensor 2 signal 4 to 20 mA

sensor 1 analogue output0 to 10 V

sensor 3

0 V analogue

HDA 6000

HDA 6000

programming enable

digital 0V

relay K 1

relay K 2

relay K 3

relay K 4

* S1 closed or bridge connected = programming enable S1 open = programming disable

HDA 3000-B +

sensor 1

HDA 3000-B +

sensor 2

1

2

11

+12 V

sensor 1 signal 4 to 20 mA

sensor 2 signal 0 to 10 V

sensor 3 0 to 10 V

0 V analogue

HDA 6000

sensor 1with built-in

power supply

+4 to 20 mA 1

2

3

+12 V

–12 V

sensor 1 signal 4 to 20 mA

HDA 6000

printer RXD

computer TXD

terminal GND

TXD

RXD

digital 0 V

13

14

15

3

2

1

HDA 6000

+ 12 V

pulse output*reset input

digital 0 V

1

10S2

15

A

HDA 3000-B +

sensor 3

12

5A

A

1

11

10

20 110/220 V AC ± 10%24 V DC

Page 26: Electronics

Applications:

Approvals:

Electronics Catalog

Pressure Switches

23

EDS 300About EDS Pressure Switches:The EDS 300 is a compact unit which combines a pressure transducer, digital display, 2 switches, and analog output for controlling pressure in hydraulic andpneumatic systems. The transducer converts system pressure into an electricalsignal for the display and analog output. External adjustments allow the user toset the pressure switch points and switchback points. The 3 way functionality ofthis device offers a large cost savings to purchasing a gauge, transducer, andswitch individually.

Technical Details:Input Data

Measuring Ranges -14 to 75 psi;0 to 150, 1000, 3000, 6000, 9000 psi

Overload Pressures 150% FSBurst Pressure 300% FSOutput DataAccuracy (display, analog output) ≤ ±1.0% FS max.Repeatability ≤ ±0.5% FS max.

Temperature Drift zero point max:≤ ±0.016% / ˚F (≤ ±0.03% / ˚C)range max: ≤ ±0.016% / ˚F (≤ ±0.03% / ˚C)

Analog Output 4 to 20 mA, ohmic resistance ≤ 400 ΩSwitching OutputsType PNP transistor outputSwitching Current max. 1.2 ASwitching Cycles ≥ 100 millionReaction Time approx. 10 msAmbient ConditionsTemperature Range of Medium -13 to 176 ˚F (-25 to 80 ˚C)Ambient Temperature Range -13 to 176 ˚F (-25 to 80 ˚C)Storage Temperature Range -40 to 176 ˚F (-40 to 80 ˚C)Nominal Temperature Range 14 to 158 ˚F (-10 to 70 ˚C)

mark EN 50081-1 and -2, EN 50082-1 and -2Vibration Resistance approx. 10 g / 0 to 500 HzShock Resistance approx. 50 g / 1msOther DataSupply Voltage: EDS 356-1 12 to 32 VDCEDS 356-2, EDS 356-3 20 to 32 VDCElectrical Connection 4 pole plug M12x1Current Consumption approx. 100 mA (without switching output)

Safety Type IP65Hydraulic Connection SAE 4 femaleParts in Contact with Medium Stainless SteelMaterial of Housing Tube: Stainless SteelGf30 Keypad Housing PA6.6 Display 4-digit, 7-segment LED, redWeight approx. 300 g

Page 27: Electronics

Electronics Catalog 241-877-GO HYDAC

Plug Connection:

Model Code:

Circuit Connection:

Dimensions:

SP 1

+

-

12 to 32 VDC

lmax. 1.2 A

EDS 356-1

1

4

3

Model EDS 356-11 switching output

+

-

20 to 32 VDC

lmax. 1.2 A

RL

SP 1

analogue

l = 4 to 20 mAEDS 356-3

1 4

3 2

Model EDS 356-31 switching output 1 analogue output

SP 1

SP 2

+

-

20 to 32 VDC

lmax. 1.2 A

lmax. 1.2 AEDS 356-2

1 4

3 2

Model EDS 356-22 switching outputs

1 2

34

EDS 3 5 6 - X - XXXX - XXX.Series

EDS 3 = 300 Series Electronic Pressure Switch

Mechanical Connection5 = SAE-4 female thread (7/16-20 UNF2B)

Electrical Connection6 = M12x1 plug, 4 pole (connector not included)

Output1 = 1 Switching output2 = 2 Switching outputs3 = 1 Switching output and 1 analog output

Pressure Ranges0089 = -14 to 75 psi (-1 to 5 bar) (vacuum version see also modification number)0150 = 0 to 150 psi (10.3 bar)1000 = 0 to 1000 psi (69 bar)3000 = 0 to 3000 psi (207 bar)6000 = 0 to 6000 psi (414 bar)9000 = 0 to 9000 psi (620 bar)

Modification Number400 = standard401 = vacuum version

Note: Refer to Standard Stock list for popular model code combinations.

mode

SP1 SP2PSI

EDS

ConnectorM12x1 4 pole male

3.54"(90mm)

1.16"(29.5mm)

1.4"ø (35mm)

HexSW 1.053"

(27mm)

ø 0.787"(20mm)

EDS 300 use with ZBE 06 (see page 56)

Page 28: Electronics

Input DataMeasuring ranges -14 to 75, 150, 1000, 3000, 6000, 9000 psi

-1 to 5, 006, 016, 040, 100, 250, 400, 600 barOverload pressure 200, 300, 3000, 7000, 11000, 13000 psi

15, 15, 32, 80, 200, 500, 800, 900 barBurst pressure 400% FSOutput DataAccuracy (display, analog output) ≤ ±1% FS max.Repeatability ≤ ±0.5% FS max.

Temperature drift ≤ ±0.3% / 10 K zero point max.≤ ±0.3% / 10 K range max.

Analog output 4 to 20 mA, ohmic resistance ≤ 400 ΩSwitching OutputsType 2 relay contacts (N/O)Switching voltage 10 mV to 60 V (AC or DC)Switching current 0.01 mA to 1AMaximum switching output 30 W / 30 VA

(for inductive load, use varistors)

Life expectancy 20 million (min. load)0.5 million (max. load)

Reaction time approx. 10 msAmbient ConditionsTemperature range of medium -13° to 176°F (-25° to 80°C)Ambient temperature range -13° to 176°F (-25° to 80°C)Storage temperature range -40° to 176°F (-40° to 80°C)Nominal temperature range -14° to 158°F (-10° to 70°C)

mark EN 50081-1, EN 50081-2EN 50082-1, EN 50082-2

Vibration resistance 5 to 25 Hz: 3.2 mm25 to 500 Hz: 4 g

Other DataSupply voltage 20 to 32 VDCElectrical connection plug to DIN 43651 (6 pole + earth)

Current consumption approx. 100 mASafety type IP 65

Hydraulic connection G 1/4 A male, (torque rating approx. 15 lb-ft)SAE 4 female thread (torque rating approx. 6 lb-ft)

Parts in contact with fluid stainless steel, FPM seal

Material of housing tube: stainless steelkeypad housing: PA6.6 Gf30

Display 4-digit, 7 segment LED, redWeight approx. 300 g

Applications:

Approvals:

Electronics Catalog

Pressure Switches

25

EDS 300 - ShipbuildingAbout EDS 300 Pressure Switches:The EDS 300 is a compact, electronic pressure switch with digital display. The pressuremeasurement is based on a thin film strain gauge sensor cell in stainless steel. All partsin contact with the fluid are in stainless steel, and are welded together. Since no sealsare required in the sensor chamber, leakage is eliminated.Two relay switching outputs with N/O function and an additional analog output signal (4to 20 mA) enable the pressure switch to be incorporated into the most modern controlconcepts. The switching points and the corresponding hysteresis can easily be adjustedvia the keypad.For optimum adaptation to a particular application, the unit has many additionaladjustment parameters, e.g. switching direction of the relays, switching delay times.Areas of application are pressure or maximum value monitoring on marine transmissions,diesel engines, pumps and general hydraulic and pneumatic systems.

Technical Details:

Bureau VeritasNo.: 10343 /A0 BV

American Bureau of ShippingNo.: 00-ES 19976-X

Lloyds Register of ShippingNo.: 00/20048

Det Norske VeritasNo.: A-7710 (895.10)

Germanischer LloydNo.: 15519-00HH

Page 29: Electronics

EDS 3 X 7 - 4 - XXX - S00 (PSI)

SeriesEDS 3 = 300 Series Electronic Pressure Switch for Shipbuilding

Mechanical Connection4 = G 1/4 A DIN 38525 = SAE-4 7/16-20 UNF2B female7 = SAE-6 9/16-18 UNF2A male

Electrical Connection7 = DIN43651 plug, 6 pole + ground (connector ZBE 10 not included)

Output4 = 2 switching outputs and 1 analog output

Measuring Rangesbar version: only in conjunction with connection thread G 1/4 A:XXX = 006, 016, 040, 100, 250, 400, 600 with modification no. S00

for -1 to 5 bar use “006” and modification no. S13psi version: only in conjunction with connection thread SAE 4:XXXX = 0150, 1000, 3000, 6000 with modification no. S40

for -14 to 75 psi use “0089” and modification no. S41

Modification NumbersS00 = bar version (except for -1 to 5 bar)S13 = vacuum version -1 to 5 barS40 = psi version (except for -14 to 75 psi)S41 = vacuum version -14 to 75 psi

PSI = Additional code for psi version (not required for bar versions)

Electronics Catalog 261-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection: Plug Connection:

3PE

2

6

54

1+

-

20 .. 32 V

RL

Analoguel = 4 .. 20 mA

SP 1

SP 2

mode

SP1 SP2PSI

EDS

hex. -SW27

PlugDIN 436516 pole + earth

0.59"(15mm)

ø 0.79"(20mm)

SAE 4

G 1/4 A

0.47"(12mm)

0.08"2mm

ø 0.74"(18.9mm)

ø1.4"(35mm)

M25

3.54"(90mm)

1.16"(29.5mm)

2.15"(54.5mm)

Pin 1: + SupplyPin 2: SP Common PolePin 3: SP1 ContactPin 4: 0VPin 5: 4 to 20 mA SignalPin 6: SP2 Contact

ZBE 10 (see page 56)

Adapter Available:

0.56"(14mm)

0.27"(7mm)

Adapter SAE-4 (m) to 1/4 NPT (m) StainlessPart Number - 02701426

Page 30: Electronics

Applications:

Approvals:

Electronics Catalog

Pressure Switches

27

EDS 410About EDS 410 Pressure Switches:The electronic pressure switch EDS 410 was specially developed for use inindustrial, mobile, and transit applications.The small, compact unit has a very robust pressure sensor with thin film on astainless steel membrane. The transistor switching output (PNP) is designed sothat switching valves can be controlled directly, up to a current consumption of 1.2 Amps. The switching point and switch-back point of the EDS 410 is set bythe manufacturer according to customer specification.Various pressure ranges are available between 0 to 10 bar and 0 to 600 bar.The EDS 410 offers great flexibility with various options for electrical connections.Standard connections such as the DIN 43650 are available, as well as flyingleads if necessary.A minimum order of 50 pieces is needed.

Technical Details:Input DataMeasuring ranges 232 to 8700 PSI (16 to 600 bar)Overload pressure 150% FSBurst pressure 300% FSMechanical Connection SAE 6 9/16-18 UNF2A maleTightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media stainless steel, FPM sealOutput DataType 1 PNP transistor outputMaximum output load 1.2 ASwitch point to defineSwitch-back point to defineAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ±0.5 %FS

Temperature compensation ≤ ±0.03%FS/°Czero point ≤ ±0.017%FS/°FTemperature compensation ≤ ±0.03%FS/°Cover range ≤ ±0.017%FS/°FLong-term drift ≤ ±0.3%FS typ. / yearAmbient ConditionsNominal temperature range -13° to 185°F (-25° to 85°C)Operating temperature range -13° to 185°F (-25° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark, EMC EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance to < 20g (196.2m/s2)IEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 65Other DataSupply voltage: 12 to 32 VDC

fuse: 5 A normal blow or5 A slow blow

Residual ripple supply voltage ≤ 5%Electrical connection Connector DIN 43650 Reverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionLife expectancy >10 mil load cycles 0 to 100% FSWeight 145 g

Page 31: Electronics

Electronics Catalog 281-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

1.378"(35 mm)

3.642"(92.5 mm)

SAE 6

Hex SW 1.063"(27mm)

2.244"(57mm)

0.091"(2.3mm)

0.748"(18.9mm)

ø 1.378"(35 mm)

ø

SP1 Imax. 1.2 AFuse 5A

12 to 32 VDCEDS 410-X

13

2

+

_

EDS 410 - XXX - X - XXX -(XXX/XXX bar or psi)

SeriesEDS 410 = 410 Series Electronic Pressure Switch

Pressure RangeXXX = 232, 580, 1450, 3625, 5800, 8700 psi

= 016, 040, 100, 250, 400, 600 bar

Switch Function0 = normally open1 = normally closed

Modification NumbersXXX = defined by manufacturer

Switch PointXXX = XXX

Switchback PointXXX = XXX

EDS 410 use with ZBE 01 (see page 56)

1 23

Page 32: Electronics

Approvals:

Electronics Catalog

Pressure Switches

29

EDS 505 Adjustable Pressure SwitchAbout EDS 505 Adjustable Pressure Switches:The EDS 505 is robust and simple to operate. Essentially, it consists of a pressuremeasuring cell and evaluation electronics which convert the measuring cell signalinto a switching signal.Long life and vibration resistance are guaranteed because the unit is constructedwithout moving parts. The EDS 505 is used in hydraulic systems, process engineeringand mobile applications as a pressure monitor and two-position controller.Accumulator charging, pressure control in chucks and compressor controls are afew examples where the mechanical pressure switch has a limited use and canbe replaced by the EDS 505. An LED light on the end of the switch gives animmediate visual indication when the switches been activated.

Technical Details: Applications:Input DataMeasuring ranges 16, 40, 100, 250, 400, 600 barOverload pressure 32, 80, 200, 500, 800, 900 barBurst pressure 200, 200, 500, 1000, 2000, 2000 barMechanical Connection G 1/4 A maleTightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media stainless steel, FPM sealOutput DataAccuracy including linearity, hysteresis ≤ ±0.5%FS BFSLTemp. comp. zero point ≤ ±0.017%FS/°FTemp. comp. over range ≤ ±0.017%FS/°FRise time approx. 1 msLong-term drift ≤ ±0.3%FS typ. / yearSwitching OutputType 1 PNP transistor outputMaximum output load 1.2 ARepeatability ≤ ±0.5%FS max.Switching cycles > 100 millionReaction time 20 ms

16 bar: 1 to 16 bar40 bar: 3 to 40 bar

Field adjustable setting 100 bar: 8 to 100 barranges of the switch point 250 bar: 15 to 250 bar

400 bar: 30 to 400 bar600 bar: 40 to 600 bar

Setting range of the hysteresis 1.5 to 20% FSAmbient ConditionsNominal temperature range 14° to 158°F (-10° to 70°C)Operating temperature range -13° to 185°F (-25° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1 and EN 50081-2EN 50082-1 and EN 61000-6-2

Vibration resistance to 20 gIEC 68-2-6 at 10 to 500Hz Shock resistance 50 g/msSafety type to DIN 40050 IP 65Other DataSupply voltage: 12 to 32 VDCCurrent consumption approx. 50 mAElectrical connection DIN 43650 (3 pole + ground)Reverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionWeight 260 g

Page 33: Electronics

Electronics Catalog 301-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

EDS 505 - XXX - 4 X - 000

Series

Pressure Range016 = 16 bar (232 psi)040 = 40 bar (580 psi)100 = 100 bar (1450 psi)250 = 250 bar (3625 psi)400 = 400 bar (5800 psi)600 = 600 bar (8700 psi)

Mechanical Connection4 = G 1/4 A male

Switch Function0 = normally open1 = normally closed

Modification Numbers000 = standard

SW 27

~2.38" (60.5mm)

ø 1.38"(35mm)

2.36"(60mm)

~1.38"(35mm)

3.34"(84.9mm)

Sleeve with transparent lid

LED Light

1.02"(26mm)

G 1/4

0.74"(18.9mm)

31

2PE1 = 12V - 32 V DC2 = 0V3 = output (PNP)Imax = 1.2 APE = ground

+

12-32 V

2

1 3

EDS 5051.2 AImax

Page 34: Electronics

Approvals:

Electronics Catalog

Pressure Switches

31

EDS 601About EDS 601 Pressure Switches:The EDS 601 is an electronic two-channel pressure switch with display and analogoutput. Its digitally adjustable switching points and switching hysteresis make itparticularly suitable for applications requiring frequent change-overs or accurateswitching point settings.The variety of setting parameters ensures versatility for use in all control andmonitoring tasks in hydraulics, pneumatics, process controls and in general testand control engineering applications.

Technical Details: Applications:Input DataMeasuring ranges 16, 40, 100, 250, 400, 600 barOverload pressure 24, 60, 150, 375, 600, 900 barBurst pressure 300% FSMechanical Connection G 1/4 B femaleTightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media stainless steelOutput DataAccuracy including linearity, hysteresis ≤ 0.5% FS B.F.S.LTemp. comp. zero point ≤ ±0.014%FS/°F max.Temp. comp. over range ≤ ±0.014%FS/°F max.Long-term drift ≤ ±0.3%FS typ. / year

Signal signal 0 to 10 V ohmic resistance: min 2 kΩ4 to 20 mA ohmic resistance: max. 400Ω

Max. frequency signal output 20 HzRelay OutputsNumber / function 2 relays with change-over contactsRepeatability ≤ 0.5% FS max.Switching voltage 0.1 to 250 VSwitching current 0.025 to 2 ASwitching capacity 50 W / 400 VALife expectancy 10 million without load / 1 million at nominal loadReaction time approx. 10 ms incl. electronicsAmbient ConditionsNominal temperature range -13° to 158°F (-25° to 70°C)Operating temperature range -13° to 158°F (-25° to 70°C)Storage temperature range -40° to 185°F (-40° to 85°C)Fluid temperature range -40° to 185°F (-40° to 85°C)

mark EN 50081-1 and -2, EN 50082-1 -2Vibration resistance 25 g / 0 to 500 HzShock resistance 50 g/msSafety type to DIN 40050 IP 65Other DataDisplay 7 segment LED display, 4 digits, 13 mm highHousing material aluminum, anodizedDimensions approx. 72 x 72 x 110 mm (WxHxD)Connection supply voltage plug to DIN 43650 / ISO 4400 (3 pole + ground)Connection relay plug to DIN 43651 (6 pole + ground)Supply voltage 18 to 32 VDCCurrent consumption approx. 120 mASwitch on Current approx. 1.5 A (0.1 sec)Reverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionWeight 200 g

Page 35: Electronics

Electronics Catalog 321-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

EDS 601

PROG

SP 1 SP 2

bar

ELECTRONIC

2.83"(72mm) 0.35"

(9mm)

3.68"(93.5mm)

6.44"(163.5mm)

G 1/4 (DIN3852)

2.64"(67mm)

4.13"(105mm)

3.19"(81mm)

4.13"(105mm)

Without cable plug 7 pole

2.83"(72mm)

31 2

PE

1 = supply2 = 0V3 = analog outputPE = ground

1 = relay 1 N/C contact2 = relay 1 N/O contact3 = relay 1 common supply4 = relay 2 N/C contact5 = relay 2 N/O contact6 = relay common supply

1PE

2

63

54

EDS 601 - XXX - 000

Series

Pressure Range016 = 16 bar (232 psi)040 = 40 bar (580 psi)100 = 100 bar (1450 psi)250 = 250 bar (3625 psi)400 = 400 bar (5800 psi)600 = 600 bar (8700 psi)

Modification Numbers000 = standard

Accessories Included:Mating plug to DIN 43650 (supply voltage)Mating plug to DIN 43651 (relay contacts)

Other Accessories:Assembly set for front panel mounting

Page 36: Electronics

Applications:

Approvals:

Electronics Catalog

Pressure Switches

33

EDS 710About EDS 710 Pressure Switches:Specifically for OEM applications in mobile industry, the EDS 710 was developedas one of the smallest electronic pressure switches in the world. Switch andswitch-back points are factory set as NO or NC according to customer requirements. Output load capacity of 400 mA enables connection to controlunits (e.g. PLC) as well as small electronic devices (e.g. relays). Featuring anM12x1 connector or flying leads alternatively as electric connection, enablesflexibility regarding various wiring systems. Class of protection is IP 67 standard.In order to protect in more harsh applications, a special protective rubber coverwas invented. When used, the protection class is extended to IP 69K.A minimum order of 250 pieces per model is usually required.

Technical Details:Input DataMeasuring ranges 232 to 8700 PSI (16 to 600 bar)Overload pressure 150% FSBurst pressure 300% FSMechanical Connection SAE 6 9/16-18 UNF2A maleTightening torque approx. 15 lb-ft (20 Nm)Parts in contact with media stainless steel, FPM sealOutput DataType 1 PNP transistor outputMaximum output load 400 mASwitch point to defineSwitch-back point to defineAccuracy (B.F.S.L) including linearity,hysteresis, and repeatability ±0.5 %FS

Temp. comp. zero point ≤ ±0.017%FS/°FTemp. comp. over range ≤ ±0.017%FS/°FLong-term drift ≤ ±0.3%FS typ. / yearAmbient ConditionsNominal temperature range -13° to 185°F (-25° to 85°C)Operating temperature range -13° to 185°F (-25° to 85°C)Storage temperature range -40° to 212°F (-40° to 100°C)Fluid temperature range -40° to 212°F (-40° to 100°C)

mark, EMC EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance to <20g (196.2 m/s2) gIEC 68-2-6 at 10 to 500Hz Safety type to DIN 40050 IP 67 (w/ ZBE 06 molded cable

or flying lead)Other DataSupply Voltage 12 to 32 D VCResidual ripple supply voltage ≤ 5%Electrical connection flying leads or

M12x1 Reverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionLife expectancy >10 mil. load cycles, 0 to 100%FSWeight 145 g

Page 37: Electronics

Electronics Catalog 341-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

EDS 710 - XXX - X - XXX -(XXX/XXX bar or psi)

SeriesEDS 710 = 710 Series Electronic Pressure Switch

Pressure RangeXXX = 232, 580, 1450, 3625, 5800, 8700 psi

= 016, 040, 100, 250, 400, 600 bar

Switch Function0 = normally open1 = normally closed

Modification NumbersXXX = defined by manufacturer

Switch PointXXX = XXX

Switchback PointXXX = XXX

SP1 Imax. 400 mA

EDS 710-X+

(18.5mm)ø

0.73"

(35.5mm)1.40"

0.08"(2mm)

(18.9mm)0.74"

SAE-69/16-18 UNF

hex-SW0748 0.39"(10.0mm)

EDS 710 use with ZBE 06 (see page 56)

1 2

34

Page 38: Electronics

Approvals:

Electronics Catalog

Pressure Switches

35

EDS 1700About EDS 1700 Pressure Switches :The EDS 1700, with its built-in pressure measuring cell, a 4-digit display andthe 4 switching outputs, offers the user all the advantages of a modern electronicpressure switch.4 switching points and switch-back points can be adjusted very simply and independently of each other via a membrane keypad. For optimum incorporationinto monitoring systems (eg with PLC) an analog output is also available (4 to 20 mA or 0 to10 V.)The main applications of the EDS 1700 are in hydraulics and pneumatics. Theinstrument is ideal for use where frequent switching cycles (several million)require permanent switching point accuracy or simple and precise adjustment.

Technical Details:

Applications:

Input DataMeasuring Ranges 232, 580, 1450, 3625, 5800, 8700 psiOverload Pressures 200%, max. 1300 psiBurst Pressure 300% FSHydraulic Connection G 1/4 B femaleTorque rating 15 lb-ft (20 Nm)Parts in contact with media Stainless SteelOutput DataAccuracy P = 0.5% / N = 1.0% or(display, analog output) max. P = 0.25%FS / N = 0.5%FS both as B.F.S.L.Temperature Drift EDS 1700...P zero point max. ≤ ±0.2% / 10 K

range max. ≤ ±0.2% / 10 KEDS 1700...N zero point max. ≤ ±0.3% / 10 K

range max. ≤ ±0.3% / 10 KAnalog Output 4 to 20 mA, ohmic resistance ≤ 400 Ω

0 to 10 V ohmic resistance ≥ 2 kΩSwitching OutputsType 4 relays with change-over contacts in 2 groups

(common supply of each group connected)

Repeatability EDS 1700...P ≤ ±0.25% FS max.EDS 1700...N ≤ ±0.5% FS max.

Switching Voltage 0.1 to 250 VAC / VDCSwitching Current 0.009 to 2 ASwitching Capacity 400 VA, 50 W (for inductive load use varistors)

Life Expectancy of Contacts ≥ 20 million (minimum load)≥ 1 million (maximum load)

Reaction Time approx. 20 msSwitching Point Setting Range 1.5 to 100% FSSetting Range of Switch-back 1 to 99% FSHysteresis / Switch-back PointsAmbient ConditionsTemperature Range of Medium -13 to 176 ˚F (-25 to 80˚C)Ambient Temperature Range -13 to 140 ˚F (-25 to 60˚C)Storage Temperature Range -40 to 176 ˚F (-40 to 80˚C)Nominal Temperature Range 50 to 158 ˚F (10 to 70˚C)

mark EN 50081-1 and -2, EN 50082-1 and -2Vibration Resistance approx. 5 gShock Resistance approx. 10 gSafety Type IP65Other DataSupply Voltage 22 to 32 VDC (residual ripple ≤ 10%)Electrical Connection 14 pole terminal block

(cross-section of connection max. 1.5 mm2)

Current Consumption approx. 200 mADisplay 4-digit, 7-segment LED, red (digits 13mm high)Weight approx. 800 g

Page 39: Electronics

Electronics Catalog 361-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Mechanical Connection:

TestPoint with Hose Connection:

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Relay 4= Switching Point 4

Relay 3= Switching Point 3

Relay 2= Switching Point 2

Relay 1= Switching Point 1

GroundAnalogue Output (0 V)

Analogue Output (signal +)

Supply (0 V)

Supply (+ input voltage)

EDS 17 9 X - X - XXX - 000Series

EDS 17 = 1700 Series Electronic Pressure Switch

Mechanical Connection9 = G 1/4 B female

Display (units of pressure)1 = 4 digit bar2 = 4 digit psi

AccuracyP = 0.25% BFSLN = 0.50% BFSL

Pressure Ranges016 = 16 bar (232 psi)040 = 40 bar (580 psi)100 = 100 bar (1450 psi)250 = 250 bar (3625 psi)400 = 400 bar (5800 psi)600 = 600 bar (8700 psi)note: vacuum version on request

Modification Number000 = standard

portcenterline

portcenterline

countersunkto DIN 74-Km5(4 places)

PG 11 Cable gland(2 places)

5.9"(150mm)

3.76"(95.5mm)

4.49"(114mm)

3.15"(80mm)

1.5"(38.5mm)

4.96"(126mm)

3.3"(84mm)

ON

OFF

mo

de

SP1

ON

OFF

SP2

ON

OFF

rese

t

SP3

ON

OFF

max

SP4

+

-

bar

EDS1700

ma

x

For other mechanical connections, refer to our 1620 seriestestpoint and hose accessories.

Page 40: Electronics

Approvals:

Electronics Catalog

Pressure Switches

EDS 3000About EDS 3000 Pressure Switches:The EDS 3000 electronic pressure switch is the result of joint development andinnovation in the field of adjustable pressure switches with display. It is a compactunit which combines a pressure switch, digital display, and transducer for controllingpressure in hydraulic and pneumatic applications. The most noticeable innovationis the alignment of the serial four-digit display. After mounting, the switch may beturned as a whole. Additionally, the front panel with push buttons may be turned.This eliminates the need for mechanical adapters. Display units can be shown inbar, psi, or mpa. Pressure ranges from vacuum to 9000 psi are available.Switching outputs in one or two switch versions with or without analog outputare available when choosing model code.

270˚

350˚

Technical Details: Applications:Input DataMeasuring ranges (type 1) 0 to 15, 50 psi

(type 3) 0 to 15, 30, 50, 150, 250, 500 psi-14 to 75 psi

(type 4) 0 to 1000, 3000, 6000, 9000 psiOverload pressure 200%FS max. 900 bar (13000 psi)Burst pressure 300%FS max. 2000 bar (29000 psi)

Mechanical Connection G 1/4 A male, 1/4”-18 NPT maleSAE 6 9/16-18 UNF2A male

Tightening torque approx. 15 lb-ft (20 Nm)

Parts in contact with media Stainless steel, FPM seal (type 4)brass, ceramic, FPM seal (types 2 & 3)

Output DataAccuracy (B.F.S.L)including linearity & hysteresis ≤ ±0.5 %FS

Temp. comp. zero point ≤ ±0.017%FS/°F max.Temp. comp. over range ≤ ±0.017%FS/°F max.

Analog output signal, adjustable 4 to 20 mA, ohmic resistance ≤ 500Ω0 to 10 V, ohmic resistance ≥ 1k Ω

Switching OutputsType PNP transistor outputRepeatability ≤ ±0.5%FS max.Switching current max. 1.2 ASwitching cycles ≥ 100 millionReaction time < 10 msAmbient ConditionsNominal temperature range -13° to 185°F (-25° to 85°C)Ambient Temperature range -13° to 176°F (-25° to 80°C)Storage temperature range -40° to 176°F (-40° to 80°C)Fluid temperature range -13° to 176°F (-25° to 80°C)

mark EN 50081-1, EN 50081-2 EN 50082-1, EN 61000-6-2

Vibration resistance to ca. 10 gIEC 68-2-6 at 10 to 500HzShock resistance 50 g/msSafety type to DIN 40050 IP 67 (molded M12x1 connector is used)

Other dataSupply voltage 18 to 32 VDCElectrical connection M12x1 (4 pin or 5 pin)

Current consumption approx. 100 mA (without switching output)

Reverse polarity protection of the supply voltage, excess voltage, standardoverride and short circuit protectionDisplay 4 digit, 7 segment LED redWeight approx. 300 g

37

Page 41: Electronics

EDS 3X46-3

1

3

4

2

Imax 1.2 A

SP 118 to 32 V

+

–I = 4 to 20 mA

Analog

RL

EDS 3X46-2

1

3

4

2

Imax 1.2 A

Imax 1.2 A

SP 1

SP 2

18 to 32 V

+

I = 4 to 20 mA

Analog

RL

EDS 3X48-5

1

3

4

2

5

Imax 1.2 A

Imax 1.2 ASP 1

SP 218 to 32 V

+

EDS 3X46-1

1

3

4Imax 1.2 A

SP 118 to 32 V

+

EDS 3 X X X - X - XXXX - 400Series

EDS 3 = 3000 Series Electronic Sensor

Sensor Type1 = Ceramic absolute3 = Ceramic relative4 = Thin-film relative

Mechanical Connection6 = 1/4” - 18 NPT male thread (brass types 1 and 3)7 = SAE-6 male thread (9/16-18 UNF2A stainless steel type 4)

Electrical Connection6 = M12x1 plug, 4 pole for output codes 1, 2, and 3 (connector not included)8 = M12x1 plug, 5 pole for output code 5 (connector not included)

Output1 = 1 Switch output (only with electrical connection 6)2 = 2 Switch outputs (only with electrical connection 6)3 = 1 Switch with analog output (only with electrical connection 6)5 = 2 Switch with analog output (only with electrical connection 8)

Pressure Ranges Type 1 (ceramic - absolute) Type 3 (ceramic - relative) Type 4 (thin-film, relative)0015 = 0 to 15 psi 0015 = 0 to 15 psi 1000 = 0 to 1000 psi0050 = 0 to 50 psi 0030 = 0 to 30 psi 3000 = 0 to 3000 psi

0050 = 0 to 50 psi 6000 = 0 to 6000 psi0150 = 0 to 150 psi 9000 = 0 to 9000 psi0250 = 0 to 250 psi0500 = 0 to 500 psi0089 = -14 to 75 psi

Modification Number400 = standard in psi

Note: G 1/4 port sizes are available upon request

Electronics Catalog 381-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

mode

SAE 6ø 0.74"

(18.9mm)

6kt-SW27

0.08"(2mm)

0.47"(12mm)

ø 1.65"(42mm) M12x1

2.95"(75mm)

3.68"(93.5mm)

ø 2.15" (54.5mm)

0.63"(16mm)

ø 1.16"(29.5mm)

EDS 3XX6 EDS 3XX8 use with ZBE 06 (4-pole) & ZBE 08 (5-pole)(4-pole) (5-pole) (see page 56)

1 2

34

1 2

34

5

Model with 1 switch output Plug 4-pol. M12x1

Model with 1 switch output and signal outputPlug 4-pol. M12x1

Model with 2 switch outputsPlug 4-pol. M12x1

Model with 2 switch outputs and signal outputPlug 5-pol. M12x1

Page 42: Electronics

Applications:

Approvals:

Electronics Catalog

Temperature Transducers

39

ETS 4000About ETS 4000 Temperature Transducers:The temperature transducer series ETS 4000 was designed to be fitted directly tothe hydraulic system to ensure direct contact with the media for the most accurateand up to date temperature reading. This unit converts the fluid temperature measurement into a usable, 4 to 20mA output signal.The ETS 4000 has solid construction with all stainless steel wetted parts and tubehousing. The transducer hydraulic connection is rated to 8700 psi. All units are individually calibrated on a computer-controlled test rig and subjectedto a final test. The quality system is ISO 9001 certified.

Technical Details:Input DataMeasuring range -25° to 100°C (-13° to 212°F)Pressure resistance 600 bar (8700 psi)Pressure overload 900 bar (13050 psi)Mechanical connection G 1/4 A maleTorque rating approx. 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, FPM sealOutput DataOutput signal 2-conductor, 4 to 20 mAAccuracy ≤ ±1°C (1.8°F) max.Temperature drift 0.006%FS / °FAmbient ConditionsAmbient temperature -30°C to 80°C (-22°F to 176°F)Media temperature -25° to 100°C (-13° to 212°F )

EN50081-1, EN50081-2,mark EN50082-1, EN50082-2

Vibration resistance to ≤ 20 g (196.2m/s2)IEC 68-2-6 at 10 to 500 HzSafety type IP 65Other DataSupply voltage 10 to 30 V DCElectrical connection 4 pole Binder plug 714 M18x1Residual ripple max. 5%Maximum load resistance RL max. = (UB-10V) / 0.02 A [Ω]

Safety measures Reverse polarity and excess voltage protection, electronic current limit

Page 43: Electronics

Electronics Catalog 401-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

+ Supply

0V

RL

RL

1

4Free

2

3

Free

ETS 4144-A

Hex 6kt-SW27

0.74"(18.9mm)

0.18"(4.5mm)

0.31"(8mm)

0.24"(6mm)(Stem)

0.08"(2mm)

G 1/4 A

1.18"ø (30mm)

1.06"ø (27mm)

3.23"(82mm)

0.69"(17.5mm)

0.47"(12mm)

ETS 4 1 4 4 - A - 000Series

ETS 4 = 4000 series temperature transducer

Accuracy1 = 1°C (1.8°F)

Mechanical Connection4 = G1/4 A male

Electrical Connection4 = 4 pole Binder plug 714 M18x1 (connector not included)

Output SignalA = 2 conductor, 4 to 20mA

Modification Number000 = standard

ETS 4144 use with ZBE 02 or ZBE 03(see page 56)

1

2 3

4

Page 44: Electronics

Applications:

Approvals:

Electronics Catalog

Temperature Transducers

41

ETS 7000About ETS 7000 Temperature Transducers:The ETS 7000 joins the lineup of of our smallest series of transmitters. Due toit’s pressure resistance the small partner of ETS 4000 also is applicable tohydraulic systems up to 600 bar. Temperatures in the range of -25° to 100°Care transformed into output signal of 4 to 20 mA. As with the complete 7000series electric connection, M12x1, or flying leads are available alternatively.Type of protection is IP 67. While using a special protective rubber cover, thetype of protection is extended to IP 69K.

Technical Details:Input dataMeasuring principle Silicon semiconductor elementMeasuring range -13° to 212°F (-25° to 100°C)Pressure resistance 8700 psi (600 bar)Pressure overload 13000 psi (900 bar)Mechanical connection G 1/4 A maleTorque rating approx. 15 lb-ft (20 Nm)Parts in contact with media Stainless steel, Seal: FPMOutput dataOutput signal 4 to 20 mAAccuracy ≤ ±1.5%FS typ.Rise time ≤ 15 sAmbient conditionsFluid temperature range -13° to 212°F (-25° to 100°C)Operating temperature range -13° to 176°F (-25° to 80°C)Storage temperature range -40° to 212°F (-40° to 100°C)

mark EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance to ≤ 196.2m/s2 (20g)Safety type to DIN 40050 IP 67 (w/ ZBE 06 molded cable

or flying lead)Other dataSupply voltage 8 to 32 V DCElectrical connection M12x1Housing material Stainless steelWeight approx. 145 g

Page 45: Electronics

Electronics Catalog 421-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

ETS 7 2 4 X - A - 000Series

ETS 7 = 7000 series temperature transducer

Accuracy2 = 1.5%FS

Mechanical Connection4 = G1/4 A male

Electrical Connection6 = M12x1 plug, 4 pole (connector not included)0 = flying lead

Output SignalA = 2 conductor, 4 to 20mA

Modification Number000 = standard

Model Codes Containing RED are non-standard items - Minimum quantities may applyContact HYDAC for information and availability

+ Supply

0V

RL

RL

1

4Free

2

3

Free

ETS 7246-A

1 2

34

ETS 7246 use with ZBE 06 (see page 56)

M12x1 (18.65mm)ø

0.73"

(37.53mm)1.48"

G 1/4

0.38"(11.86mm)

0.47"(9.53mm)

0.27"(6.87mm)

Page 46: Electronics

Applications:

Approvals:

Electronics Catalog

Temperature Switches

43

ETS 300About ETS 300 Temperature Switches:The ETS 300 is a compact, electronic temperature switch with digital display. Itis used with the TFP 100 temperature sensor, which was especially developedfor tank mounting, or with its own integral sensor.The ETS 300 has a 2 temperature ranges allowing for use in a wide range ofindustrial applications: -13° to 212°F (-25° to 100° C) and -22° to 302°F (-30° to 150°C).The ETS 300 is offered with one or two switching outputs with an optional 4 to20 mA analog output signal for remote temperature monitoring.The switching points and hysteresis are easily adjustable via the membranekeypad. Other parameters are accessible and displayed on the digital readout,then adjustable via the keypad.

Technical Details:

Temperature Sensor TFP 100Temperature range of medium -40° to 257°F (-40° to 125°C)Electrical connection 4 pole Binder plug 714 M18x1Safety Sleeve for Tank-Mounting the TFP 100Parts in contact with medium All materials compatible with nickel

Input data for integral sensorMeasuring range -13° to 212°F (-25° to 100°C)Pressure resistance 13000 psi (600 bar)Hydraulic connection G 1/2 A maleTorque rating approx. 33 lb-ft (45 Nm)Parts in contact with media Stainless steel, Seal: FPMInput data for separate sensorDisplay range -22 to 302°F (-30° to 150°C)Sensor connection M 12x1, 4 poleOutput dataAccuracy (display, analog output) ≤ ± 2.0°F (≤ ± 1.0°C)Temperature drift (zero point and range) ≤ ± 0.0085% / °FReaction time (T09) approx. 20 sAnalog output 4 to 20 mA, ohmic resistance ≤ 400 ΩSwitching outputsType PNP transistor outputSwitching current max. 1.2 AAmbient conditionsTemperature range of medium -13° to 212°F (integral sensor)Ambient temperature range -13° to 176°FStorage temperature range -40° to 176°FNominal temperature range -14° to 158°F

mark EN 50081-1 and EN 50081-2EN 50082-1 and EN 50082-2

Vibration resistance approx. 10 g / 0 to 500 HzShock resistance approx. 50 g / 1msOther dataSupply voltage 20 to 32 VDCCurrent consumption approx. 100 mA (without switching output)Safety type IP 65

Material of housing tube: stainless steelkeypad housing: PA6.6 Gf30

Display 3 digit, 7 segment LED, red, height of digits 9.2 mm

Weight approx. 300 g

Note: Depending on the temperature range of the temperature sensor fitted, this canreduce the display range of the ETS 300 with separate sensor input.

Page 47: Electronics

Electronics Catalog 441-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

EDS 3 X X - X - XXX - XXX.Series

ETS 3 = 300 series electronic temperature Switch

Mechanical Connection2 = G 1/2 A male thread with integral sensor8 = electrical connection for separate sensor (TFP 100)

Electrical Connection6 = M12x1 plug, 4 pole for output codes 2 & 3 (connector not included)8 = M12x1 plug, 5 pole for output codes 5 (connector not included)

Output2 = 2 switching outputs (only in conjunction with electrical connection type “6”)3 = 1 switching output and 1 analog output (only in conjunction with electrical connection type “6”)5 = 2 switching output and 1 analog output (only in conjunction with electrical connection type “8”)

Measuring Ranges100 = -25° to 100°C (-13° to 212°F) only for version with integral sensor150 = -30° to 150°C (-22° to 302°F) only for version with separate sensor

Modification Number000 = display in °C400 = display in °F

+

-

20 to 32 VDC

lmax. 1.2 A

RL

SP 1

SP 1

SP 2

analogue

l = 4 to 20 mAETS 3X6-3

1 4

3 2

+

-

20 to 32 VDC

lmax. 1.2 A

RL

SP 1

analogue

l = 4 to 20 mA

ETS 3X8-5

lmax. 1.2 A

SP 11 4

3 2

+

-

20 to 32 VDC

lmax. 1.2 A

lmax. 1.2 AETS 3X6-2

1 4

3 2

Model ETS 3X6-22 switching outputs

Model ETS 3X8-52 switching outputs 1 analogue ouput

Model ETS 3X6-31 switching output 1 analogue output

mode

SP1 SP2PSI

ETS

3.44"(87.5mm)

1.16"(29.5mm)

HexSW27

2.97"(75.5mm)

0.67"(17mm)

~2.05"(52mm)

1.16"(29.5mm)

ø 0.87"(22mm)

mode

SP1 SP2PSI

ETS

ConnectorM12x1

4 pole male

ConnectorM12x1

4 pole male

G 1/2A

0.12"(3mm)

0.71"(18mm)

0.55"(14mm)

1.4" (35mm

1.4"(35mm)

ø 0.24" (6mm)

connection cable LIYCY(3m length)

M 12x1connector

ø ø

ZBE 03 plug

0.65"(16.5mm)

0.55"(14mm)

TFP 100 (temp. sensor)

ø 0.24"(6mm)

ø 0.76"(9.3mm)

ø 1.06"(27mm)

ø 0.31"(8mm)

0.12"(3mm)

hex SW27

0.73"(18.5mm)

0.55"(14mm)

G 1/2

26mm

3.94"(100mm)

Safety Sleeve

4.96"(126mm)

ETS 3X6 ETS 3X8 ZBE 06 (4-pole) & ZBE 08 (5-pole)(4-pole) (5-pole) (see page 56)

1 2

34

1 2

34

5

Page 48: Electronics

Applications:

Approvals:

Electronics Catalog

Temperature Switches

45

ETS 1700About ETS 1700 Temperature Switches:The electronic temperature switch ETS 1700 is used together with the temperature sensorTFP 100, which was specifically developed for tank mounting.

The 4 digit display can indicate either the actual temperature, one of the switching points,or the maximum temperature. The maximum temperature indicates the highest temperaturewhich has occurred since the unit was switched on or last reset.

The 4 switching outputs can be used to control heating and cooling processes inhydraulic systems, as an example. All switching and switch-back points, which are independent of each other, can be adjusted very simply via a membrane keypad. Forincorporation into monitoring systems (e.g. with PLC), an analog output(4 to 20 mA or 0 to 10 V) is also available.

Technical Details:Input DataMeasuring Range 32° to 212°F (0° to 100°C)Output Data

Output Signal 4 to 20 mA, ohmic resistance ≤ 400 Ω0 to 10 V, ohmic resistance ≤ 2k Ω

Accuracy (display, analog output) ≤ ± 1.0% of the measuring rangeRepeatability ≤ ± 0.25% of the measuring rangeTemperature Drift in the zero point: ≤ ± 0.054%/°F (≤ ± 0.03%/°C)ambient temperature range range: ≤ ± 0.054%/°F (≤ ± 0.03%/°C)

Switching Output Type 4 relays with change-over contacts in 2 groups(common supply of each group connected)

Switching Voltage 0.1 to 250 VAC / VDCSwitching Current 0.009 to 2 ASwitching Capacity 400 VA, 50 W (for inductive load use varistors)

Life Expectancy of Contacts ≥ 20 million (minimum load)≥ 1 million (maximum load)

Reaction Time (without switching delay) approx. 20 msSwitching Point Setting Range 1.5 to 100% FSSetting Range of Hysteresis / 1 to 99% FSSwitch-back PointsAmbient ConditionsAmbient Temperature Range -13 to 140 ˚F (-25 to 60 ˚C)Storage Temperature Range -40 to 176 ˚F (-40 to 80 ˚C)

mark EN 50081-1 and -2, EN 50082-1 and -2Vibration Resistance approx. 5 gShock Resistance approx. 10 gSensor Connection 5 pole Binder connector, series 681Other DataSupply Voltage 22 to 32 VDC (residual ripple ≤ 10%)

Electrical Connection 14 pole terminal strip(cross-section of connection max. 1.5 mm2)

Current Consumption approx. 200 mADisplay 4-digit, 7-segment LED, red (digits 13mm high)Safety Type IP 65Weight approx. 800 g

Page 49: Electronics

Electronics Catalog 461-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

ETS 17 XX- 100 - 000 .Type of Sensor

ETS 17 = Temperature Switch for use with TFP 100 sensor(Temperature sensor TFP 100 must be ordered separately - see page 55)

Display (temperature unit of measure)

01 = 4 digit °C02 = 4 digit °F

Measuring Range100 = 32° to 212°F (0° to 100°C)

Modification Number000 = standard

14

13

12

11

10

9

8

7

6

5

4

3

2

1

Relay 4= Switching Point 4

Relay 3= Switching Point 3

Relay 2= Switching Point 2

Relay 1= Switching Point 1

GroundAnalogue Output (0 V)

Analogue Output (signal +)

Supply (0 V)

Supply (+ input voltage)

sensorresistance

TFP 100

4 pole Binderconnectorseries 7141 2 3 4

1 2 3 4 5

ETS 1700

5 pole Binderconnectorseries 723

15

2

3

4

Pin 1 = + supplyPin 2 = + signalPin 3 = reservedPin 4 = - signalPin 5 = - supply

= plug housing for screen

1

2 3

4

Pin 1 = + supplyPin 2 = + signalPin 3 = - signalPin 4 = - supply

Internal view of pin connections (on the ETS 1700)5-pole Binder connector, series 723

Internal view of pin connections (on the TFP 100)4-pole Binder connector, series 714

connection portcenterlinecountersunk

to DIN 74-Km5(4 places)

PG 11 Cable gland(2 places)

5.9"(150mm)

3.76"(95.5mm)

4.49"(114mm)

3.15"(80mm)

1.5"(38.5mm)

4.96"(126mm)

3.3"(84mm)

ON

OFF

mo

de

SP1

ON

OFF

SP2

ON

OFF

rese

t

SP3

ON

OFF

max

SP4

+

-

¡C

ETS1700

ma

x

1.46"(37mm)

connection line LIYCY(3m long)

5 pole BinderSeries 723

ZBE 03 plug

0.65"16.5mm

0.55"14mm

ø 0.76" 19.3mm

ø 1.06" 27mm

TFP 100 (temp. sensor)

ø 0.24" 6mm ø 0.31"

8mm

0.12"3mm

hex SW270.73"18.5mm

0.65"14mm G 1/2

1.02"26mm

3.94"100mm

Safety Sleeve

4.96"126mm

Page 50: Electronics

Applications:

Approvals:

Supply Voltage 10 to 32 V DCSignal Output 4 to 20 mA, 2 conductor

mark EN 50081-1, EN 50081-2,EN 50082-1,EN 50082-2

Temperature of Media -4° to 194°F (-20° to 90°C)Ambient Temperature -4° to 158°F (-20° to 70°C)Media - EVS 3100 hydraulic oil

EVS 3110 waterPermissible Viscosity Range 1 to 100 cStCalibrated at - EVS 3100 30 cSt

EVS 3110 5 cStAccuracy Class ≤ 2% of the instantaneous valueMeasuring Ranges/Operating Pressure

EVS 3100-1 6 to 60 l/min / 400 bar (1.6 to 15.9 gpm / 5800 psi)EVS 3100-2 40 to 600 l/min / 315 bar (10.6 to 159 gpm / 4567 psi)EVS 3100-3 15 to 300 l/min / 400 bar (4 to 79.3 gpm / 5800 psi)EVS 3100-5 1.2 to 20 l/min / 400 bar (0.26 to 5.28 gpm / 5800psi)

Electrical Connection 4 pole Binder plug 714 M18x1Mechanical Connection/Torque Rating

EVS 3100-1 G 1/2 female thread / approx. 130 NmEVS 3100-2 G 1 1/2 female thread / approx. 600 NmEVS 3100-3 G 1 1/4 female thread / approx. 500 NmEVS 3100-5 G 1 1/4 female thread / approx. 60 NmEVS 3100-1-SAE 37 Available with SAE thread using adapters.EVS 3100-2-SAE 37 Thread is 37° flare.

Additional Connections 2 x G 1/4 female ports for pressureon Housing or temperature sensors

Electronics Catalog

Flow Rate Sensors

47

EVS 3100 Flow Rate SensorAbout EVS 3100 Flow Rate Sensors:The EVS 3100 series flow rate sensors are designed to accurately measure theflow-through volume of fluids in hydraulic systems. The unit uses a stainlesssteel turbine wheel internal to the construction, which converts the media flowinto a 4 to 20mA output signal. The in-line mounting design allows for most accurate and up to date flowmeasurements. The EVS 3100 also offers two additional hydraulic ports toaccommodate additional sensors, ex. temperature and pressure transducers.The design of the flow meter incorporates a lightweight aluminum housing withaccurate and stable measuring elements.The unit uses the Woltmann Turbine principle to measure flow. The fluid entersthe housing and passes through straightening blades, which assist in stabilizingthe media into a laminar flow. The stainless steel turbine wheel is rotated by themedia flow, which then influences the magnetic field of the inductive receiverwith the passing of each turbine fin. The inductive receiver is the sensing elementof this flow meter. This influence produces a voltage pulse in the receiver, whichit then converts into a 4 to 20mA output signal.This design provides precise data within the entire measurement range of theunit, and is relatively tolerant against minimal, gritty contamination. The meteralso allows for exceeding flow of up to 50% of the maximum range for shortperiods of time.

Technical Details:

Page 51: Electronics

Electronics Catalog 481-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Plug Connection:

Meas. PmaxModel Range Material L H D / SW* G DN in bar (1 Tmax (2

(gpm)

EVS 31X0-1 1.6-15.9 Alumin. 144 135 48.5 / 46 G 1/2” 11 400 -20 to 90°C

EVS 31X0-3 10.6-159 Alumin. 155 150 63.5 / 60 G 1 1/4” 22 400 -20 to 90°C

EVS 31X0-2 4-79.3 Alumin. 181 150 63.5 / 60 G 1 1/2” 30 315(A) 400(S) -20 to 90°C

EVS 31X0-5 0.3-5.3 Alumin. 117 135 47.0 / 46 G 1 1/4” 7 400 -20 to 90°C

Two-Conductor 4 to 20 mA

RL max = (UB-10V)/0.02A [Ω]UB = + supply voltage

G 1/4" G 1/4"

SW

L

H

D DNG

free

free

3

4

EVS 3100

+ supply

0V

1

2

EVS 31 X 0 - XSeries

EVS 31= Flow Rate SensorSeries

0 = Aluminum1 = Stainless Steel

Flow Rating1 = 1.6 - 15.9 gpm (6 - 60 l/min)2 = 10.6 - 159 gpm (40 - 600 l/min)3 = 4 - 79.3 gpm (15 - 300 l/min)5 = 0.3 - 5.3 gpm (1.2 - 20 l/min)

EVS 3100 use with ZBE 02 or ZBE 03(see page 56)

1

2 3

4

Page 52: Electronics

Electronics Catalog

Diagnostics

49

HMG 2020

The HMG 2020 generally distinguishesbetween three measurement options:

1. Normal measurementPurely a display function wherethe measured values are displayedimmediately. Ex: When HMG is measuringwith pressure sensors to act as a digital gauge.

2. Curve measurementThe measured values are displayedand simultaneously stored continuously in the internal memory. The courses of thecurves can be printed out on theprinter as soon as measuring hasstopped, or transferred to a PCand viewed with the software.

3. Log measurementThe measured values are dis-played and can be stored as logentries in the internal memory.This method of measurement isused primarily for long-termmeasurements (e.g. one week, onemonth, one year etc.). The log entriescan be printed out on a printeras soon as measuring has stopped,or transferred to a PC.

The internal memory can store upto 50 different curves and logs with250,000 measured values in total.

To optimize your measurements theunit has a wide variety of additionalfunctions:

• Choice of languageThe user may define which lan-guage the unit will display thedata and parameters.

The HMG 2020 is a portable data recorder for recording pressure, temperature, flow rate, rpm etc. in industrial machinery and systems(e.g. hydraulics, pneumatics). The HMG 2020 can record the measured valuesfrom up to five sensors simultaneously.

• 2 inputs for 4 to 20 mA sensors

• 2 inputs for either 4 to 20 mA or 0 to 10 V sensors

• 1 frequency input for digital signals in the range 0.3 to 30,000 Hz

• The measurement range and the unit for each sensor can be set asrequired (e.g. 0 to 250 bar, -25° to 100°C, 0 to 217 KN). Therefore, the majorityof commercially available sensors with standard output signals can beconnected and evaluated.

• As well as the current measured values, the unit also records the mini-mum and maximum values, in addition to the differential between twosensors of the same type.

Measurement inputs 4 analog inputs / 1digital inputChannel A and B 4 to 20mA,Ri approx. 100 ΩChannel C and D 4 to 20mA, Ri approx. 100 Ω or0 to 10V,

Ri approx. 80 K ΩChannel E 0.3 Hz to 30 KHz,0 to 24V,

switching threshold approx. 4 VAccuracyMeasuring channels 0.25% of the measuring rangeA, B, C, DMeasuring channel E 0.02% of the instantaneous valueMeasuring RateNormal operation 100 msFast measurement can be reduced right down to approx. 1 ms

(depending on the sensors connected)

Resolution 10 bitDisplay LCD display, 2 lines, each with 16 charactersAnalog output 0.2 to 4 V(Channel A and B)InterfacesSerial (RS 232) 300 to 38400 baud, 8 data bits, 1 stop bit, 1 start bit,

no parity check, handshake with CTS on pin 5 (only for printer version)Note: The plug connection on the HMG does not correspond

to the RS 232 standard.

Parallel standard connection, compatible with CentronicsPlug connectionsSensor connection D-sub 9-pole, socketInterfaces D-sub 25-pole, socketVoltage supplyExternal voltage 12...30 V DC, charging current max. 500 mA constant

supply possible charging time approx. 3 hours whenbatteries flat

Internal voltage 4 x NiMH batteries 1.2 V, MignonBattery life depending on the type of sensors connected e.g.: (with NiMH 1 AH with 2 HYDAC pressure transmitters (4 to 20 mA signal)batteries) approx. 10 hours operation possible

markOperating 10° to 40°CtemperatureAir humidity 0 to 70% relative, non-condensingWeight approx. 500g

General:

Technical Details:

Page 53: Electronics

HMG 2020 - 004 - ESeries

Series = HMG 2020Modification number

004 = standard American unitUser manual and documentation

E = English

Electronics Catalog 501-877-GO HYDAC

• Two trigger possibilitiesDefinition of events which start a curve measurementor which, on a log measurement, transfer the currentmeasured values to memory.Ex: A curve is to be recorded when the temperatureexceeds 50°C or the system pressure falls below 25bar. The two triggers can in addition be linked togeth-er logically (and/or following one another chronologically), sothat data is recorded exactly at the required moment.

• Definable displaysDefine which measured variables should appear onthe unit display.Ex: User display 1 of 5: current temperature value,peak value of the flow rate, minimum pressure valueand current rpm value.

• Identification of recorded curves or logsThe user can program in a specific ‘company name’and assign a specific station number to the systembeing presently worked on. This specifies which sys-tem each measurement was recorded from.

• Printer OptionsThese options enable print outs (black & white or color)to be done on commercially available printers.Additional details can be obtained from the technicalinformation in this brochure, or simply by contacting one of our distributors.

4x NiMH rechargeable batteries, 1x power adapter for 110 VAC,1x 2 meter A/B sensor cable (A/B cables with Binder M714 typeelectrical connections), 1x operating manual, 2x ZBE-04 BinderM714 to DIN 43650 adapters.Accessories must be ordered with full details:• Pressure Transducers

HDA 3700 & 3800 series (available from -1 to 9 to 0 to 600 bar)HDA 4400 & 4700 series (available from 0 to 150 to 0 to 9000 psi)

• Temperature sensorETS 4144-A-000 -25° to +100°C (-13° to 212°F)

• Flow rate sensor• Turbine Style

EVS 3100-1 (6 to 60 l/min, 1.6 to 15.9 gpm) @ 400 barEVS 3100-2 (40 to 600 l/min, 10.6 to 159 gpm) @ 315 barEVS 3100-3 (15 to 300 l/min, 4 to 79.3 gpm) @ 400 barEVS 3100-5 (1.2 to 20 l/min, 0.3 to 5.3 gpm) @ 400 bar

• Measuring orifice (determines flow rate via differential pressure)EVS 1000-020 ( 5 to 20 l/min)EVS 1000-080 (20 to 80 l/min)EVS 1000-350 (80 to 350 l/min)

• Revolutions per minute frequency sensorHDS 1000

• Current sensor simulator SSS 1000

• Hydraulic adapter set (Minimess series) consisting of:2 off adapter hoses DN 2 / 400 mm 1620/16202 off adapter hose DN 2 / 1000 mm 1620/16202 off pressure gauge direct connections 1620/G 1/42 off adapters 1615/16202 off bulkhead couplings 1620/1620

• Universal adapter setUVM 2000

• HMGWIN PC softwareWith PC connection cable (for serial interface) and 9-pole to 25-pole adapter

• Analog output cableFor channels A and B

• Connection cables(A/B cable or C/D cable) with 2 Binder plugs for pressure, tem-perature or flow rate sensors in the following lengths: 2m; 5m;10m; 20m.

• ZBE 04(Binder plug adapter, series M714, to Hirschmann DIN 43650)Enables connection of pressure transmitters HDA 3XX5-A (2-conductor 4...20mA signal with Hirschmann plug) via the A/B orC/D connection cable

• Aluminum or plastic carrying case with foam rubber insert

Note: Older series, HMG 2010, can be converted to an HMG 2020.

Model Code:

The following are supplied:

Deluxe HMG Diagnostic KitsSee the inside back cover for details

Page 54: Electronics

Screen showing multiple graphsand whole measurement curve

Electronics Catalog

Diagnostics

51

HMGWINThe HMGWIN PC program expands themeasurement options of the portable HMG2020 data recorder. HMGWIN is compatiblewith Windows 95/98/NT, user friendly, aninteractive software package that allows theuser to download the stored data and studyit in greater detail.

For the user who wishes to store or furtherevaluate the recorded measurement curvesand measurement logs, this HMGWIN providesa range of useful functions.

Features:

• Transfer and Storage of curves and logsfrom the HMG 2020 to a PC.

• Viewing of up to 4 different recordedcurve or log measurement simultaneouslyon the monitor.

• Superimposition of curves Parts of different curves can be superimposed in a new graph, for example to show the wear and tear of amachine (new condition/current condition).

• Straight edge functionAs with a straight edge, you can measurethe curves using the mouse (exact timeand amplitude value). Absolute measuredvalues and also relative measured values(measurement in relation to a set marker) canbe displayed.

• Zoom function Using the mouse, part of a graph can beframed. The framed area appears as anew graph, enlarged accordingly.

• Online functionThe portable data recorder measuresand transfers the current measured valuesstraight onto the PC. These are thenimmediately displayed as a graph in realtime (comparable with the function of anoscilloscope). The graph displayed canbe stored if there are any interesting results.

• Portable data recorder Settings can be transferred to the PCand may be stored. The reverse is alsopossible, so, for example, settings fortaking measurements on a particularmachine can be fed into the HMG 2020again and again.

• Data conversionHMGDESK can convert the HMG 2020data into some other data formats. Thismeans, for example, that the recordedcurves can be transferred to many otherPC programs (spreadsheets, database,word processing etc.) and further processed.

HMG 2020 connected to a PC

Zoomed section from overlayOverlay of two measurement curves

Page 55: Electronics

Electronics Catalog 521-877-GO HYDAC

ACCESSORIESThe following are accessories availablefor use with the HMG 2020 RecordableData Recorder:

1 Portable Data Recorder HMG 2020Measurement unit for recording allsensor signals. Base unit of the com-plete measurement unit set includingmain supply units.

2 HMGWIN softwareWindows based PC software pro-gram designed to extend the meas-urement possibilities of the HMG2020. Compatible with Windows 95,98, and NT.

3 Pressure transmitterFor pressure measurement we supplypressure transmitters in the accuracyclasses 0.3%, 0.5% and 1%, withmany different measuring rangesfrom 0 to 150 psi up to 9000 psi.Required output signals: 4...20 mA or0...10 V.

4 Temperature sensorThe temperature sensor ETS 4000has a measuring range of -25...100°Cwith current output 4...20 mA. It ispressure resistant up to 8700 psi.

5 Flow rate sensorFor accurate flow rate measurement(< ± 2% of the instantaneous value) wesupply aluminum turbines as stan-dard in the measuring ranges 1.2 to 20 l/min; 6...60 l/min; 15...300 l/min and 40...600 l/min.Each supplies an output signal of4...20 mA, and have two G 1/4” BSPthreaded connections for connectingadditional sensors, ex: pressuretransmitters and temperature sen-sors. Our flow rate meters are alsoavailable in stainless steel with variousmeasuring ranges.

6 HDS 1000The rpm probe HDS 1000 is suitablefor measuring the speed of rotatingbodies. The principle is based on areflecting light barrier with adhesivefoil strips.

7 Flow rate orificeThe measuring orifice EVS 1000 enablescost-effective flow rate recording viadifferential pressure measurement.The following measuring ranges areavailable as standard 5...20 1/min,20...80 1/min and 80...350 1/min.The measuring points of the measur-ing orifice are in each case Minimessconnections, series 1620.

8 Universal adapter setThe universal adapter set, UVM 2000,is needed to connect more than twosensors for simultaneous measure-ment (distributor function) or if externalsensors are used. These can be con-nected by means of screw terminals.

9 SSS 1000The current sensor simulator SSS1000 was designed for teaching pur-poses. It can be used to simulate twocurrent sensors (4...20 mA) via rotarypotentiometers. Personnel can learnhow to use the HMG, or consolidatetheir knowledge of the unit, in theoffice. The current sensor simulator isparticularly suitable for staff training.

10 Hydraulic adapter setThe hydraulic adapter kit allowspressure transmitters with G 1/4” Aexternal thread to be connected toexisting Minimess pressure connec-tions, series 1620 or 1615.

11 Analog output cableThe analog output cable can beused to transfer the current meas-ured values of channels A and B asa voltage signal to an oscilloscopeor a recorder.

12 PC CableConnects HMG to computer

13 Sensor ConnectionCables A-B and C-D

6

7 5

9

3

13

8

1

10

12

11

2

4

13

Page 56: Electronics

Electronics Catalog

Diagnostics

53

SMZ 1000About SMZ 1000 Current Probes:The PR300/SP2 current probe is based on Hall Effect technology for non intrusive,true RMS measurement of DC, AC, & complex waveform current. This probewas designed to be used in conjunction with the HMG 2020 diagnostic unit.

Technical Details:General CharacteristicsMaximum Conductor Size - SMZ 1000-1 19 mm diameter

SMZ 1000-2 50 mm diameterOutput connection 2 m cable terminated with

9 pole sub-D plugOperating temperature range 32° to 122°F (0° to 50°C)Storage temperature range (with battery removed) 14° to 185°F (-10° to 85°C)Operating humidity 15% to 85% (non condensing)Weight - SMZ 1000-1 290 g

SMZ 1000-2 540 gElectrical CharacteristicsMeasuring range - SMZ 1000-1 2 A ACRMS or DC

SMZ 1000-2 300 A ACRMS or DCAnalog output - SMZ 1000-1 1 V per 1 A

SMZ 1000-2 0.5 to 9.5 V = 0 to 300 AAccuracy - SMZ 1000-1 < 1% of reading ±5 mA

SMZ 1000-2 ± 2% of reading ± 0.5 ALoad impedance ≥ 10kΩFrequency range3) (small signal) DC and 15Hz - 20kHz (-3b)Temperature coefficient ± 0.1% of reading / °CMaximum offset drift (0° to 70°C) ± 200 mVPower supply ± 12V ± 5%

Page 57: Electronics

Electronics Catalog 541-877-GO HYDAC

Dimensions:

Model Code:

Circuit Connection: Safety Standards:

ON

OFF

1.36"(34.5mm)

9.84"(250.0mm)

2.52"(64.0mm)

0.937"(2.38mm)

7.25"(184.4mm)

0.75"(19.0mm)

2.13"(53.9mm)

CU

RR

ENT PR

OB

E

MO

DEL

SERIAL N

o.

OU

TPUT

LEM

HE

ME

Pin Number Function9 + 12 V3 + Output7 0 V

BSEN61010-1: 1993 and Amendment A2: July 1995BSEN61010-2-032: 1995BSEN61010-2-031: 1995

SMZ 1000-1

SMZ 1000-2

SMZ 1000 - X - 000Series

SMZ 1000 = SMZ 1000 current probeCurrent Range

1 = 0 to 2 A2 = 0 to 300 A

Modification Number000 = standard

Page 58: Electronics

Electronics Catalog

Accessories

55

About TestPoints and Hoses:HYDAC series 1620, guided piston design, TestPoints are compact, selfsealing couplings that provide access to hydraulic and pneumatic systemsfor pressure measurement to 9000 psi. Mating adapters or hose connectionscan be connected without loss of fluid while the system is operating.TestPoints can also be used to take oil samples or to bleed air from hydraulicsystems. They are available in 1620 (M16x2.0) connection threads with avariety of screw-in port configurations.

Series 1620 TestPoints

TechnicalMaximum Working Pressure• 9000 psi (630 bar)Fluid Compatibility• Suitable for petroleum based fluids

and gaseous mediaMaterials• Zinc plated steel body are standard

• Zinc plated metal cap standardSeals• Buna-N standard

• Viton optionalTemperature Range• With metal cap and Buna-N seals:

-22°F to 248°F (-30°C to 120°C)Options• Anti-vibration seal for metal cap

ZBE 03 plug

0.65"16.5mm

0.55"14mm

ø 0.76" 19.3mm

ø 1.06" 27mm

TFP 100 (temp. sensor)

ø 0.24" 6mm ø 0.31"

8mm

0.12"3mm

hex SW270.73"18.5mm

0.65"14mm G 1/2

1.02"26mm

3.94"100mm

Safety Sleeve

4.96"126mm

TFP 100Part # 00904696

Safety Sleeve TFP 100Part # 00906170

Technical Details:

L(in) L (mm) Part No.

7.87 200 02700233

39.37 1000 02058783

ø5 mm

L

Micro Bore Flexible Hoses• Maximum working pressure 9000 psi

(630 bar)• Suitable for petroleum based fluids• Temperature range -4°F to 212°F

(-20°C to 100°C)• Polyamid core with polyester braid

reinforcement and polyamid cover• Plastic dust cap• 1620 female connection at both ends• Bending radius: min. 20mm• Hose ID ø 2mm

Temperature Sensor TFP 100Temperature range of medium -40° to 257°F (-40° to 125°C)Electrical connection 4 pole Binder plug 714 M18x1Safety Sleeve for Tank-Mounting the TFP 100Parts in contact with medium All materials compatible with nickel

TestPoint Size Part No.

1/4NPTM 02700146

SAE 4-7/16-20 UNF 02700536SAE 6-9/16-18 UNF 02058786G1/4 ISO 228 02700571

More hose and testpoint sizes available from VCA catalog #02070729

Page 59: Electronics

ZBE 06 Connector4 Pole M12x1 90°

ZBE 01 Connector Part # 00905701DIN 43650 / ISO 4400 (IP65)

Electronics Catalog

Connectors

561-877-GO HYDAC

ZBE 06 = connector only (IP65)Part # 06006788

ZBE 06-02-4 = with 2 meter Cable (IP67)Part # 02701196ZBE 06-05-4 = with 5 meter Cable (IP67)Part # 02701197

ZBE 02 Connector Part # 00609479M18x1 (IP65)

ZBE 03 Connector Part # 0060948090° M18x1 (IP65)

ZBE 04 Connector Part # 00258011DIN 43650/ISO4400 to M18x1 (IP65)

ZBE 10 Connector Part # 0065452790° DIN 43651 (IP65)

ZBE 08 Connector5 Pole M12x1 90°

ZBE 08 = connector only (IP65)Part # 06006786

ZBE 08-02-5 = with 2 meter Cable (IP67)Part # 06006792ZBE 08-05-5 = with 5 meter Cable (IP67)Part # 06006791

Page 60: Electronics

ZBM 14 Part # 00907818G 1/4 Alignment Adapter for EDS 300

ZBM 15 Part # 00907750SAE-6 (f) to SAE-6 (m) w/ 0.5mm Snubber

Adapter Part # 02067166G 1/4 (f) to SAE-6 (m) w/ 0.5mm Snubber

ZBM 13 Part # 00906968G 1/4 (f) to G 1/4 (m) w/ 0.5mm Snubber

ZBM 11 Part #00258055G 1/4 Alignment Adapter for EDS 300

ZBM 09 Part # 00907367G 1/4 (f) to G 1/4 (m) w/ 0.8mm Snubber

ZBM 03 Part # 00257163G 1/4 (m) to G 1/4 (m)

0.75"(19mm)

0.62"(16mm)

0.09"(2mm)

0.75"(19mm)

0.62"(16mm)

0.09"(2mm)

0.75"(19mm)

0.62"(16mm)

0.12"(3mm)

0.27"(7mm)

1.06"27mm

0.62"(16mm)

0.09"(2mm)

0.75"(19mm)

0.55"(14mm)

0.12"(3mm)

0.56"(14mm)

0.27"(7mm)

0.75"(19mm)

0.85"(22mm)

Electronics Catalog

Adapters

57

Adapter Part # 027011881/8” NPT (f) to G 1/8” (m)

Adapter Part # 02075267SAE-6 (f) to 1/4” Schrader

Adapter Part # 02066754SAE-6 Alignment Adapter forEDS 300 Shipbuilding

Adapter Part #02055566G 1/4 (f) to SAE-6 (m)

0.86"(22mm)

0.55"(14mm)

0.75"(19mm)

1.49"(38mm)

0.64"(16mm)

0.62"(16mm)

0.75"(19mm)

0.71"(18mm)

0.75"(19mm)

0.97"(25mm)

0.75"(19mm)

0.96"(24mm)

Adapter Part # 02701426SAE-4 (m) to 1/4” NPT (m) Stainless

Adapter Part # 02055899G 1/4 (f) to 1/4” NPT (m) Stainless

Page 61: Electronics

Electronics Catalog

Mounting Kits

581-877-GO HYDAC

EDS 1600/1700 and ETS 1600/1700 Mounting KitPart # 00257492

ZBM 300 Wall Mounting ClampPart # 00906385

ZBM 310 Wall Mounting ClampPart # 06011511

EDS 601 Mounting KitPart #00905404

Clamping KitPart #435812

Page 62: Electronics

Electronics Catalog

Demonstration Kits

59

Pressure Switch Part Number3000 psi (switch / analog) 020718043000 psi (single switch) 020701036000 psi (single switch) 02071443-14 to 75 psi (single switch) 02071444Kit Includes:

1 - Pressure Switch1 - 4 Pole M12 Connector with Plug1 - Power Supply1 - Carrying Case

Part # 02076985with integral probeKit Includes:

1 - ETS 326-3-100-4001 - 4 Pole M12 Connector with Plug1 - Power Supply1 - Carrying Case

Part # 02076986with separate temperature sensorKit Includes:

1 - ETS 386-3-150-4001 - TFP 100 Probe with Safety Sleeve1 - 4 Pole M12 Connector with Plug1 - Power Supply1 - Carrying Case

EDS Pressure Switch Kits

ETS Temperature Switch Kits

Page 63: Electronics

Electronics Catalog 601-877-GO HYDAC

HMG Deluxe Diagnostic KitPart # 02070911HYDAC has packaged these components to be the perfect start-upkit for performing diagnostics on mobile & industrial applications.You can add HYDAC flow sensors, different pressure & temperaturetransducers at any time. Also included is an extra ZBE 04 connectorfor connecting to existing transducers & indicators already installedon your equipment.

Kit Includes:A - HMG 2020-004-E

(rechargeable batteries included)B - Power Supply CordC - UVM 2000 Connector HubD - C & D Sensor CableE - A & B Sensor Cable

Entire kit comes neatly packaged in a durable carrying case.(see photo on page 50.) Complete operation manual is included.

F - PC CableG - HMG WIN softwareH - HDA 4475 Pressure Transducers (3)

(1000, 3000, and 6000 psi)I - ETS 4144 Temperature TransducerJ - ZBE 04 Connectors (4)

A

B

H I J

C D EF

G

Page 64: Electronics

Bladder, Piston, & Diaphragm Types; Pulsation Dampeners & Shock Absorbers;Safety & Shut-off Blocks; Charging & Gauging Units; Mounting Components & Accessories

Hydraulic Oil; Lube Oil; Fuel & Fuel Oil; Water; Process;High Pressure; Return Line; Suction; Strainers; Inline; Manifold-mount; Modular Stacking;In-tank; Inside Tank; Circuit Protectors; Spin-on; Backflush; Selectable Duplex; Clogging Indicators;Wide Variety of Elements Including Interchanges for All Major Brands; Private Labeling for OEM’s

Offline & Portable Filters; Online & Portable Realtime Particle Counters; Water Sensors;Fluid Sampling Kits; Fluid Analysis Kits; Vacuum Dehydration Water Removal Units

High & Low Pressure Ball Valves; Flow, Needle, & Check Valves;Hydraulic/Pneumatic Actuators; Custom Valve Design

Hose, Tube, & Pipe Clamps; Cushion Clamps; Band Straps;U-bolts; Fixed Cylinder Clamps; Custom Clamping Solutions

TestPoints & Flexible Test Hoses; Fluid Level Indicators; Gauge Isolators;Suction Strainers; Breathers; Filler/Breathers; Desiccant Breathers

Pressure & Temperature Transducers & Switches; Flow Rate Meters;Current Probes; Digital Displays; Portable Data Recorders

Air-Cooled & Water-Cooled Models; Cooler, Pump/Filter, & Pump/Filter/Cooler Units;AC Industrial Models; DC & Hydraulic Drive Mobile Models

High Pressure & Compact Power Units;Standard & Custom Integrated Control Units

Pressure Controls — Reducing & Relieving Valves; Proportional Pressure & Flow Control Valves;Check Valves; Flow Controls; Load Controls — Counterbalance & Pilot-Op. Check Valves;Custom Manifold Design & Manufacturing; Solenoid Directional Valves — Poppet & Spool Types;5000 psi, up to 40 GPM; Inline Mounting Bodies

Central Valve Blocks; Suspension Control; Steering Control;Power Attachment Controls; Design & Application Assistance

© Copyright 2002 HYDAC TECHNOLOGY CORPORATIONBrochure - Electronics Catalog #02075078 / 9.02

The Single Source for Hydraulic Components