www.baumerprocess.com Data Sheet A 11 D6.181 Design and specifications subject to change without notice Page 1 ED 701 – Hygenic Pressure Transmitter Hygienic process connections Complete range of electrical connections 4 ... 20 mA and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response time < 25 ms (Option 5 ms) High long-term stability Excellent repeatability Active compensation for temperature drifts ATEX II 1G, II 2G, II 1/2G and II 1D Lloyd‘s Register Approval Compatibility with CIP/SIP Description The large choice of pressure and electrical connections makes the ED 701 series suitable for a large variety of applications. The ED 701 pressure transmitters are available in 4 … 20 mA current loop or in voltage output signal versions. This transmitters offer a very high accuracy over a wide temperature range, an excellent repeatability and long time stability as well as a short response time (down to 5 ms). The piezo-resistive silicon sensor is anodic bonded on a very stable glass base, which is attached to a stainless steel construction. This assembly guarantees an excellent thermal isolation. The sensor is isolated from the process by a stainless steel diaphragm (1.4435 / 316L) and a filling liquid. The electronics is located within the hermetically sealed transmitter housing which gives the ED 701 an excellent resistance to humidity, shock and vibration. Protection class, from IP 65 to IP 67 only depends on the choice of the electrical connection. The electronics is a state-of-the-art signal processing unit fitted with a fast micro-controller allowing the compensation of drift effects due to temperature on the sensor signal, over a wide temperature range with a fast response time. The ED 701 is available with a great variety of pressure and electrical connections to meet all requirements. The electrical connection can be replaced easily and gives access to the Autozero adjustment. The hygienic design of the ED 701 series is particularly dedicated to the food and beverage processing industry, the pharma and the biotechnology industry. According to its ATEX approval the ED 701 can be used in potentially explosive atmospheres (gases, vapors and dust). The ED 701 has got the Lloyd‘s Register approval, which makes it the ideal product for environments such as in the marine, offshore and industrial applications. ED701 for general industry applications: refer to datasheet ED701_Industrial (D6.180, ED701 – General Industry Transmitter)
12
Embed
ED 701 – Hygenic Pressure Transmitter - PCN Europe · Data Sheet A 11 D6.181 Design and specifications subject to change without notice Page 1 ED 701 – Hygenic Pressure Transmitter
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.baumerprocess.com Data Sheet A 11 D6.181
Design and specifications subject to change without notice Page 1
ED 701 – Hygenic Pressure Transmitter
Hygienic process connections
Complete range of electrical connections
4 ... 20 mA and Voltage outputs
Accuracy: 0.1%, 0.2% and 0.4% FS
Quick response time < 25 ms (Option 5 ms)
High long-term stability
Excellent repeatability
Active compensation for temperature drifts
ATEX II 1G, II 2G, II 1/2G and II 1D
Lloyd‘s Register Approval
Compatibility with CIP/SIP
Description
The large choice of pressure and electrical connections makesthe ED 701 series suitable for a large variety of applications. TheED 701 pressure transmitters are available in 4… 20 mA currentloop or in voltage output signal versions. This transmitters offer avery high accuracy over a wide temperature range, an excellentrepeatability and long time stability as well as a short responsetime (down to 5 ms).
The piezo-resistive silicon sensor is anodic bonded on avery stable glass base, which is attached to a stainless steelconstruction. This assembly guarantees an excellent thermalisolation.
The sensor is isolated from the process by a stainless steeldiaphragm (1.4435 / 316L) and a filling liquid. The electronics islocated within the hermetically sealed transmitter housing whichgives the ED 701 an excellent resistance to humidity, shock andvibration. Protection class, from IP 65 to IP 67 only depends onthe choice of the electrical connection.
The electronics is a state-of-the-art signal processing unitfitted with a fast micro-controller allowing the compensation ofdrift effects due to temperature on the sensor signal, over a widetemperature range with a fast response time.
The ED 701 is available with a great variety of pressure andelectrical connections to meet all requirements. The electricalconnection can be replaced easily and gives access to theAutozero adjustment.
The hygienic design of the ED 701 series is particularlydedicated to the food and beverage processing industry, thepharma and the biotechnology industry. According to its ATEXapproval the ED 701 can be used in potentially explosiveatmospheres (gases, vapors and dust). The ED 701 has gotthe Lloyd‘s Register approval, which makes it the ideal productfor environments such as in the marine, offshore and industrialapplications.
ED701 for general industry applications: refer to datasheet ED701_Industrial (D6.180, ED701 – General Industry Transmitter)
Process connectionMalethreadG1”flushdiaphragmcone J MalethreadG1”flushdiaphragmO’ring K MalethreadG1⁄2”flushdia.DIN3852(CombiConnect)1) L MalethreadG1⁄2”flushdiaphragmO’ring1)2) ZMalethreadG1⁄2”flushdiaphragmcone3) WAsepticClampDIN11864-3(Additionalcodeneeded) FClampDIN32676(Additionalcodeneeded) HNeumoBioConnect®asepticconnection(Additionalcodeneeded) I ClampISO2852(Additionalcodeneeded)1) NTri-Clamp®,sanitaryclampconnection(Additionalcodeneeded)1)2) YMalethreadG1⁄2”EN837-1forassemblywithpressureseal2)4) 8 MalethreadG1⁄4”EN837-1forassemblywithpressureseal2)4) 9Specificprocessconnection(Additionalcodeneeded) 0
AccuracyMedium temperature up to 125°C0.4%FS,compensatedtemperaturerange–10°…+125°C 10.2%FS,compensatedtemperaturerange–10°…+125°C 20.1%FS,compensatedtemperaturerange–10°…+80°C 35 ms response time0.4%FS,5ms,compensatedtemperaturerange–10°…+80°C 60.2%FS,5ms,compensatedtemperaturerange0°…+60°C 7High medium temperature0.4%FS,integratedcoolingneck(uptomax.300°C)7)8) A0.2%FS,integratedcoolingneck(uptomax.200°C)7) B
Pressure unit Gaugepressure(100mbarupto40bar) 3Absolutepressure(400mbarupto40bar) 4Negativegaugepressure(0…-100mbar,-1…40bar) 5
Pressure range 100mbarupto40bar:gaugepressure 400mbarupto40bar:absolutepressure
Process connection Code F (Ordering code Position 1) – Aseptic clamp DIN 11864-3Thefollowingadditionalcodesareavailable.Othersonrequest: /9390 Clampconnectionwithexternaldiameter50.5mm,BKS,SeriesA,FormA,NominaldiameterDN25DIN. PipeaccordingtoDIN11866-A. /9391 Clampconnectionwithexternaldiameter50.5mm,BKS,SeriesB,FormA,NominaldiameterDN33.7ISO. PipeaccordingtoDIN11866-B Example:ED701Fxx.xxx.xxx.xx/9391
Process connection Code H (Ordering code Position 1) – Clamp DIN 32676 Thefollowingadditionalcodesareavailable.Othersonrequest: /9533 Clampconnection,externaldiameter50.5mm,,NominaldiameterDN25,DN32andDN40. PipeaccordingtoDIN11850 Example:ED701Hxx.xxx.xxx.xx/9533
Process connection Code I (Ordering code Position 1) – Neumo BioConnect® aseptic connectionThefollowingadditionalcodesareavailable.Othersonrequest: /9402 FlangeformV,NominalDimension48.3.Flangeexternaldiameter100mm.PipeaccordingtoDIN11866-B, DINENISO1127 Example:ED701Ixx.xxx.xxx.xx/9402
Process connection Code N (Ordering code Position 1) – Clamp ISO 2852 Thefollowingadditionalcodesareavailable.Othersonrequest: /9412 Clampconnection,externaldiameter34mm,NominalDimensionDN21.3.PipeaccordingtoISO2037 /9413 Clampconnection,externaldiameter50.5mm,NominalDimensionDN25.PipeaccordingtoISO2037 /9414 Clampconnection,externaldiameter50.5mm,NominalDimensionDN33.7andDN38. PipeaccordingtoISO2037 /9416 Clampconnection,externaldiameter64mm,NominalDimensionDN40andDN51.PipeaccordingtoISO2037 /9418 Clampconnection,externaldiameter77.5mm,NominalDimensionDN63.5.PipeaccordingtoISO2037 Example:ED701Nxx.xxx.xxx.xx/9414
Process connection Code Y (Ordering code Position 1) – Tri-Clamp®, sanitary clamp connection Thefollowingadditionalcodesareavailable.Othersonrequest: /9451 Tri-Clamp®3/4“connection,externaldiameter24.9mm. /9452 Tri-Clamp®1“connection,externaldiameter50.4mm. /9453 Tri-Clamp®11/2“connection,externaldiameter50.4mm. /9454 Tri-Clamp®2“connection,externaldiameter63.9mm. Example:ED701Yxx.xxx.xxx.xx/9451
Process connection Code 0 (Ordering code Position 1) – Specific pressure connection Thefollowingadditionalcodesareavailable.Othersonrequest: /9483 BBS-Systems®,Quick-Connectasepticclampwithnotch,ISODN25,Externalclampdiameter50.5mm /9486 Malethread1“-11.5NPT,flushdiaphragm Example:ED7010xx.xxx.xxx.xx/9483
Specific pressure range: /SETRAnapplicationspecificpressurerangecanbedefinedhere.Therangemustbegiveninplaintext.Thesmallestavailablepressurerangesare100mbar(gaugeandnegativegaugepressure)and400mbar(absolutepressure).Example:/SETR500mbar…2500mbarSpecific calibration temperature (temperature of the medium): /9007/TTTTExample:/9007/0100.TheED701willbecalibratedforamediumtemperatureof100°C(exfactory).Thisoptionisreducingthecompensatedtemperaturerangeto±25°Caroundthespecifiedcalibrationtemperature.Ferrite content according to customer specifications /9330Ferritecontentofthepiecesincontactwiththefluidaccordingtocustomerspecifications.Example:/9330/Pressureconnection<1%,weld<3%.Free of oil and grease /9331Freeofoilandgrease(piecesincontactwiththefluid).TheED701iscleanedandpackedaccordingly.Pressure connection electropolished according to customer specifications /9344Thepressureconnectioniselectropolishedaccordingtocustomerspecifications.Onlyavailablewithcode8attheposition10oftheorderingcode.Example:/9344/Ra0.4.Language of the Test Certificate and Operating Manual:BothdocumentsareavailableinGerman,FrenchandEnglish.Thedesiredlanguagemustbespecifiedinplaintextwiththeorderingcode.StandardwillbeGerman.
ED701 without integrated cooling neck (Ordering code Position 5: Code 1, 2, 3, 6 or 7): ED701withFDAwhiteoil: -10°C…+125°C ED701withsiliconorhalocarbonoil: -30°C…+125°C
ED701 with integrated cooling neck (Ordering code Position 5: Code A or B): Forhighmediumtemperature(120°Candhigher)theED701hastohaveanintegratedcoolingneck. ED701withcoolingneckwith FDAwhiteoil: -10°C…+200°C ED701withcoolingneckwithsiliconor halocarbonoil: -30°C…+300°C
4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDCa 1 1 Red Red 3 3 1 1b 2 2 Black Black 1 1 2 2c - 3 - Green - 4 - 3d Case Case Case Case 4 4
Viewsolderingside,cablesocket
Welding sleeves
Code D a H Material Ordering code J G1” 55 23 Stainlesssteel1.4435 D 11737.0002 J G1” 55 23 HastelloyC D 11737.0022 W G1⁄2” 35 20 Stainlesssteel1.4435 D 11737.0000 W G1⁄2” 35 20 HastelloyC D 11737.0020
Code D a H Material Ordering code
K G1” 60 20.5 Stainlesssteel1.4435 D 12403.1 Z G1⁄2” 60 20.5 Stainlesssteel1.4435 D 12403.0
Front piece with thread
Code D a b sw Material Ordering code J G1” 18 27 41 Stainlesssteel1.4435 D 11870.0002 J G1” 18 27 41 HastelloyC D 11870.0022 W G1⁄2” 12 23 27 Stainlesssteel1.4435 D 11870.0000 W G1⁄2” 12 23 27 HastelloyC D 11870.0020
aD
H
Pin assignment
Contact DIN 43650 plug Bendix 6 poles plug Cable 3 conductors DIN 41524 Binder plug
4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDC 4...20mA 0...5/10VDCa 1 1 B B Blue Blue 3 3b 2 2 E E Brown Brown 1 1c - 3 - D - Black - 4d GND GND Case Case Shield Shield Case Case