Top Banner

of 8

EcoAID Stormwater Management System

Apr 14, 2018

Download

Documents

Matt Eberle
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 7/30/2019 EcoAID Stormwater Management System

    1/8

    ECOAID CHAMBERSFOR UNDERGROUND STORMWATER MANAGEMENT

    DETENTION / RETENTION /INFILTRATION / HARVESTING

    with sediment +gross-pollutant removal

    100% AUSTRALIAN

    DESIGNEDMADE & OWNED

  • 7/30/2019 EcoAID Stormwater Management System

    2/8

    LOCATION

    Not subject to vehicle loading

    Subject to vehicle loading

    Not in roadway

    In sealed roadway

    Under unsealed roadway

    Manuactured in Australia to ISO Quality

    Management System standards.

    The arch and end cap size and weight are opti-

    mised or sae liting and rapid deployment by

    installation personnel.

    TYPICAL CROSS SECTION

    300mm sub-base material. Compact in 2 lits to 95% Standard

    Proctor density, (eg Class 1 or 2 crushed rock RCC)

    Hmin*

    300mm

    450mm

    600mm

    750mm

    Hmax

    2500mm

    2500mm

    2500mm

    2500mm

    Min/Max cover H

    Nonwoven geotextile

    300mm typically 150mm Min

    150mm Min

    980mm Min

    150mm Min

    1160mm

    20-50mm crushed aggregate (

  • 7/30/2019 EcoAID Stormwater Management System

    3/8

    Size (W H Installed L)

    1160 mm 680 mm 1000 mm

    Chamber Storage

    516 litres / 0.516 m3 per arch

    Example Installed Storage

    Volumes

    953 litres / 0.953 m3/m o

    chamber (stone with 55%

    void space, storage depth

    = 1000mm, 150mm

    chamber spacing)

    1010 litres / 1.010 m3/m o

    chamber (stone with 40% void

    space, storage depth = 1200mm,

    300mm chamber spacing)

    Min. Installed Storage Height

    980 mm

    Weight

    Arch 15.0 kg^

    End Cap - 5.0 kg^

    Shipping

    (Pallets1.16 m 1.14 m)

    32 Arches + 4 End Caps

    per pallet

    Note

    ^ values are typical weights and

    are subject to +/- 3% manuac-

    turing and raw material specic

    gravity variance.

    TECHNICAL DATASHEET

    ecoAID EC-1000 CHAMBER

    600mm MAX O.D.

    1160mm

    1160mm

    270mm

    680mm

    1135mm

    1000mm INSTALLED

    EC-1000 END CAP

    EC-1000 ARCH

    Accepts 100 or 150mm

    equalisation pipes

    Accepts 100 or

    150mm inspection

    port riser or

    downpipe

    03

    EcoAIDs modular approach to stormwater storage,

    along with our superior structural strength enables

    the optimal use o land available or development.

    There is no need to avoid heavily tracked areas, and

    the shape o the installation is completely exible.EcoAIDs articulated joints even allow or placement

    on radii as small as 25m, so the geographical contour

    o a site, or the curves o a road or roundabout can be

    ollowed.

    With ecoAID chambers being completely buried, the

    expected service lie will be typically 10 times that

    o above ground Poly tanks that are exposed to UV

    degradation. Thereore, the carbon ootprint will be

    much smaller over the liespan o the system. EcoAID

    chambers have a much smaller carbon ootprint than

    concrete tanks and galvanised steel due to the energy

    intensive nature o abrication o these materials, and

    with incredibly ecient stacking o arches or trans-

    portation the carbon miles are also minimised.

    (NOT TO SCALE)

    OPTIMISE YOUR LAND USEMINIMISE YOUR CARBON FOOTPRINT!

  • 7/30/2019 EcoAID Stormwater Management System

    4/8

    The shortall o many modular stormwater detention and inltration systems is

    their inability to address the sediment and solids that are transported in the storm-

    water during a rainall event. When stormwater is transported by pipe into a larger

    storage it slows down, and depending on the reduction in velocity or detention

    time within the storage, much o the solid mass being carried by the stormwater

    will be deposited. EcoAID ofers a simple and efective way to manage the solids

    entering the system.

    APPLICATIONSDETENTION, INFILTRATION/RECHARGE

    TREATMENT

    The environmental benets o solids removal are well documented, however the

    more efective a system is at removing contaminants and solids the more oten it

    will need to be cleaned - yes? Well, not necessarily. It also depends on the volume

    available or sedimentation and solids deposition.

    04

    EcoAID enables the

    designer to maximise this

    volume and minimise themaintenance return

    interval, so you spend less

    time and money cleaning

    it out! This is called a win

    / win situation!

  • 7/30/2019 EcoAID Stormwater Management System

    5/8

    EcoAID can be used to harvest rain and stormwater in much

    the same way that natural aquiers or perched groundwater

    can be accessed by bores. One major advantage is that we are

    creating and replenishing that resource rom water captured

    of roos and other hard suraces, such as carparks and roads,as opposed to extracting rom a natural aquier that may have

    taken thousands o years to orm, and cannot be replenished

    as easily.

    In a natural aquier water is puried through slow percolation

    and ltration. Similarly the EcoAID system is able to lter and

    treat captured water using a variety o natural or synthetic

    lter media.

    Best o all, the system is not taking up additional land

    space being below ground, and is secure rom vandalism,

    re and thet, and not exposed to UV degradation or large

    temperature variations.

    05

    INFILTRATION /

    RECHARGE

    DETENTION

    HARVESTING

    TREATMENT

    HARVESTING

    HARVESTING

    ENGINEERED

    LINER

  • 7/30/2019 EcoAID Stormwater Management System

    6/8

    ENVIRONMENTAL BENEFITS

    LOW CARBON FOOTPRINT AND CARBON MILES

    The system is 100% recyclable and has been load

    tested with recycled crushed construction waste or

    the embedment media, potentially diverting many

    tonnes away rom landlls.

    State-o-the-art manuacturing eaturing low energyconsumption, servo-hydraulic plant with energy

    savings between 20 and 80%.

    High energy consuming materials such as steel

    or concrete are not required or system strength.

    With EcoAID being manuactured in Australia, the

    carbon miles are lower than imported systems. The

    stacking and transportation eciency makes ecoAID

    chambers a sound environmental choice compared to

    oversize round pipe in detention and inltration appli-

    cations.

    STORMWATER TREATMENT

    Sediment and gross pollutant management and

    removal capability, with longer maintenance intervals

    than stand-alone GPTs due to the large volume avail-

    able or sediment and gross pollutant collection.

    LONG SERVICE LIFE

    UV degradation is not a actor with the EcoAID

    system being buried. In stormwater harvesting

    applications the service lie could be up to 10 times

    longer than above ground Poly tanks that are exposed

    to UV.The storage is serviceable due to unimpeded access

    to the rows or cleaning and maintenance rom the

    ground surace level, so storage volume is not lost

    over time.

    06

    EASY TRANSPORTATION ANDHANDLING

    Rapid installation o the chambers due to optimisa-

    tion o system size / maneuverability (by one person)

    versus storage capacity.

    Conormance to Australian and New Zealand Occu-

    pational Health and Saety recommendations orliting by one person with system components weigh-

    ing 15kg or less. (it has been shown that by keeping

    manual liting weights to less than 16kg risk o injury

    is greatly reduced)

    Stacking eciency on standard pallets ensure

    transportation costs are kept low, and installation is

    not slowed moving product around on site.

    With 30 arches per pallet (32 export) and the unit

    (installed) length 1.0m exactly, it is easy to place stacks

    at the required spacing to minimise manual handling.

    ARCH WEIGHT

    15kg per single unit.

  • 7/30/2019 EcoAID Stormwater Management System

    7/8

    SUPERIOR STRUCTURALPERFORMANCE

    Ecoaids superior structural strength allows end uses

    above the system such as high volume roads, car-

    parks, and specialised sporting suraces. The structural

    integrity o the system has been rigorously assessed

    via ull-scale eld trials and a laboratory testing regimedevised in consultation with Australian and New

    Zealand roads and transportation agencies and

    specialised pavement testing bodies. Australia and

    New Zealand build roads diferently to other countries,

    with a high percentage o pavements having spray

    or chip seal wearing courses, so testing and conor-

    mance to local criteria and standards is essential.

    07

    The EcoAID chamber system meets or exceeds the

    ollowing essential criteria as stipulated by local

    transportation agencies:

    Load bearing capacity under static and dynamic

    design vehicle plate loads. [AS 1597.1-1974, andVicRoads - Road Design Guidelines (Part 7 - Drainage)]

    Short and long-term allowable deections.

    [AS/NZS 2566.1-1998]

    Manuacturing and Quality processes (MQC/MQA)

    to ISO/TS 16949 standards.

    If the system you have been specifying or using is

    not up to this standard please contact our sales or

    technical support department.

  • 7/30/2019 EcoAID Stormwater Management System

    8/8

    AUSTRALIA

    ecoAID Pty Ltd

    T / (61 3) 9940 1551

    F / (61 3) 9381 0700

    technical@

    ecoaid.com.au

    www.ecoaid.com.au

    NEW ZEALAND

    Maccaerri NZ

    T / 0800 60 60 20

    F / (64 9) 634 6492

    technical@

    maccaerri.co.nz

    www.maccaferri.co.nz

    HIGH QUALITY TECHNICALASSISTANCE IS CLOSE AT HAND!

    EcoAID is able to provide technical support to Design

    Engineers, Architects, Developers and Contractors.

    Inormation relating to application suitability, system

    sizing, design specications / CAD, and installation

    training can be provided in DVD, electronic, or printormat. Feel ree to contact us or our distributors

    directly using the details provided below, or visit

    our website, where additional general and technical

    inormation is available. Which ever method you

    preer, its our goal to provide the highest level o

    technical assistance in a timely and proessional

    manner.

    Copyright.

    All rights reserved.

    EcoAID Pty Ltd, 2012.

    AUSTRALIA

    ecoAID Pty Ltd

    T / (61 3) 9940 1551

    F / (61 3) 9381 0700

    technical@

    ecoaid.com.au

    www.ecoaid.com.au

    NEW ZEALAND

    Maccaerri NZ

    T / 0800 60 60 20

    F / (64 9) 634 6492

    technical@

    maccaerri.co.nz

    www.maccaferri.co.nz

    HIGH QUALITY TECHNICALASSISTANCE IS CLOSE AT HAND!

    EcoAID is able to provide technical support to Design

    Engineers, Architects, Developers and Contractors.

    Inormation relating to application suitability, system

    sizing, design specications / CAD, and installation

    training can be provided in DVD, electronic, or printormat. Feel ree to contact us or our distributors

    directly using the details provided below, or visit

    our website, where additional general and technical

    inormation is available. Which ever method you

    preer, its our goal to provide the highest level o

    technical assistance in a timely and proessional

    manner.

    Copyright.

    All rights reserved.

    EcoAID Pty Ltd, 2012.