Top Banner
Earth’s Changing Environment Lecture 23 Fred’s Utility Bill
15

Earth’s Changing Environment Lecture 23

Jan 22, 2016

Download

Documents

nowles

Earth’s Changing Environment Lecture 23. Fred’s Utility Bill. Energy Efficiency. Utility is promoting energy efficiency in two ways. Space Heating with Natural Gas. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Earth’s Changing Environment Lecture 23

Earth’s Changing EnvironmentLecture 23

Fred’s Utility Bill

Page 2: Earth’s Changing Environment Lecture 23

Energy Efficiency

Utility is promoting energy efficiency in two ways.

Page 3: Earth’s Changing Environment Lecture 23

Space Heating with Natural Gas

Advisory claims that heating with an electric resistance furnace cost $1,400 and heating with natural gas cost $555. This is about 40%.

Page 4: Earth’s Changing Environment Lecture 23

Energy Use

Energy use shifts with season.

Page 5: Earth’s Changing Environment Lecture 23

Cost of Energy

Bill is complicated, but

Electricity costs $0.057/kWh

Gas costs $0.71/ccf

Page 6: Earth’s Changing Environment Lecture 23

Furnace Efficiency

80% for gas furnace.

Page 7: Earth’s Changing Environment Lecture 23

Air-Conditioner Efficiency - SEER

10% for AC

Page 8: Earth’s Changing Environment Lecture 23

Problem and Solution

During February, a San Antonio homeowner used 100 ccf of natural gas for space heating.

Complete combustion of 1 ccf of natural gas releases 1 therm of heat

1 therm = 100,000 Btu of heat. AFUE of the Fred’s furnace = 80. Electric resistance heating releases 3413 Btu

per kWh Natural cost $0.71 per ccf. Electricity costs $0.057 per kWh.

Page 9: Earth’s Changing Environment Lecture 23

How much heat did the gas heater supply?

100 ccf 100 therm 100 therm x 0.80 = 80 therm = = 8,000,000 Btu

Page 10: Earth’s Changing Environment Lecture 23

What was the cost of the natural gas used?

= 100 ccf x $0.71/ccf = $71

Page 11: Earth’s Changing Environment Lecture 23

How much heat would have to be supplied if an electric heater were used? 80 therms = 8,000,000 Btu

Page 12: Earth’s Changing Environment Lecture 23

How much electricity would the electric heater use? 8,000,000 Btu / 3413 Btu/kWh = 2,343 kWh

Page 13: Earth’s Changing Environment Lecture 23

How much would this electricity cost?

2,343 kWh x $.057 = $134

So the ratio of the cost of the electricity to the cost of natural gas would be $134 / $71 = 1.9

It would cost almost twice as much to heat with electricity!

Page 14: Earth’s Changing Environment Lecture 23

How much energy must be supplied at the utility to supply the heater’s electric energy?

2,343 / 0.30 = 7813 kWh 7813 kWh x 3413 Btu/kWh =

26,700,00 Btu = 267 therm So the ratio of the energy

needed to supply electric heating to the energy to supply the gas heat = 267 therm / 100 therm = 2.67

Almost three times as much primary energy is needed to supply electric heat as to supply gas heat.

Page 15: Earth’s Changing Environment Lecture 23

Compare the CO2 emission for electric and gas heating

Coal releases 26 tons / QBtu Gas releases 14 tons / QBtu Ratio of CO2 emission coefficients =

26/14 = 1.87 Ratio of CO2 emission =

(Coeff. x Energy)E / (Coeff. x Energy)G = CoeffE / CoeffG x EnergyE / EnergyG = 1.87 x 2.67 = 5.0

Five times as much CO2 is emitted to supply electric heat as to supply gas heat.