Top Banner
altona Diagnostics GmbH Mörkenstr. 12 22767 Hamburg Germany phone +49 40 548 06 76 - 0 fax +49 40 548 06 76 - 10 e-mail [email protected] February 25 th 2015 Laboratory Diagnostics of Filovirus Infections
56

e-mail [email protected] Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

Feb 09, 2019

Download

Documents

haliem
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

altona Diagnostics GmbH Mörkenstr. 12 22767 Hamburg Germany phone +49 40 548 06 76 - 0 fax +49 40 548 06 76 - 10 e-mail [email protected]

February 25th 2015

Laboratory Diagnostics of Filovirus Infections

Page 2: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Introduction

Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013) Emerging and tropical diseases (MERS-CoV, Filovirus, RVFV, Dengue

Type, Zika virus, …) At altona we currently only work with real-time PCR technology!

Page 3: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

What is your role in your institution?

Who is responsible for laboratory diagnostics? Who is responsible for treatment? Who will advice public health measures?

Page 4: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

How does the ideal diagnostic tool look like? Sensitivity high Specificity 100% Easy-to-use Fast < 30 min. Cheap Internal control Quantitative No cool chain required No power supply needed

RELIABLE!

Page 5: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Basic Considerations on the Workflow

1) Biosafety Protect yourself and others!

2) Reliability

Use the correct method! Prevent contamination and wrong results!

3) Efficiency

Deliver results quickly!

Importance

Page 6: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Equipment and Methods

Nucleic acid extraction: Manual extraction

More “hands-on” time The reference methods are usually very good! Flexible up to a certain extend (input and output volumes, sample

material) Validate in combination with PCR assay!

Automation

Good and bad systems out there! Closed systems

Is it possible to include internal controls? Expensive Laboratory footprint Needs to be validated for every assay!

Page 7: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Sample Inactivation

Trizol LS Agent AVL

Buffer : Sample 4 : 1

3:1 Buffer : sample

AT LEAST!

Page 8: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Equipment and Methods

First-pick real-time Cycler:

Mx 3005P™ QPCR System (Stratagene) VERSANT™ kPCR Molecular System AD (Siemens)

ABI Prism® 7500 SDS and 7500 Fast SDS (Lifetechnologies)

LightCycler® 480 Instrument II (Roche)

Rotor-Gene™ 3000/6000 (Corbett) Rotor-Gene™ Q 5/6 plex Platform (QIAGEN)

CFX96™/Dx Real-Time System (BioRad) CFX96 Deep Well™ Real-Time System (BioRad)

Page 9: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Equipment and Methods

2nd choice real-time Cycler:

PikoReal Real-Time PCR System StepOne™

SmartCycler® II

LightCycler® 2.0 Instrument

Inter-module variation - Glass capillaries

- Discontinued

Optical systems / multiplexing

Page 10: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Organisation of the Laboratories

Kitchen Office Office Office

Sample Prep

PCR Set-up II

PCR Set-up I Amplification

Negative Room

Oligo production

Oligo production

Storage

Entrance Color code: Red: infectious AND/OR highly positive Green: no DNA/RNA Orange: low positive

Example – altona Diagnostics Access

restricted

Prevention of contamination!

Page 11: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Diagnostic Scenarios

Preparedness for imported cases (initial testing) Unknown agent, broad differential diagnostics (several VHF, Malaria,

Leptospira spp., sepsis, ?) Well equipped Laboratory Few samples Not routinely performed

Old reagents (?) Reliability do you trust unfrequently used methods?

Constant training required workshops (ENIVD), participation in EQAs

Page 12: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Diagnostic Scenarios

Epidemic (follow-up testing) Known etiology Specialized assays Differential diagnostics less important Bad Infrastructure High throughput Logistics

Page 13: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Diagnostic Scenarios

Screening Contact screening Screening of healthy individuals (e.g. point of entry: airports, boarders)

Page 14: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Diagnostic Scenarios

Preparedness Outbreak

Aetiology Unknown known

Differential diagnosis

Broad Less important

Infrastructure Good Bad/difficult

Situation Sudden Timed

Routine Method used unfrequently – reliable?

Method used more often – confident

Work load Low Throughput High Throughput (?)

Training Continuous, low level

Regularly, maneuvers

Page 15: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

In-house or Commercial Kit Assays?

Page 16: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

• Performance Evaluation

• Stability

• Controls

• Quality Control

• Post Market Surveillance

Page 17: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

in house Solutions

?

Page 18: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

• Performance Evaluation

• Stability

• Controls

• Quality Control

• Post Market Surveillance

Analytical Sensitivity

Analytical Specificity

Cross-Reactivity

Interfering Substances

Total Failture Rate / Robustness

Accuracy of Measurement

Linearity

Equivalence Diagnostic Evaluation Studies

Page 19: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

• Performance Evaluation

• Stability

• Controls

• Quality Control

• Post Market Surveillance

in use

Room temperature

+4°C

Freeze & Thaw

Transport

Long term / shelf life

Page 20: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

• Performance Evaluation

• Stability

• Controls

• Quality Control

• Post Market Surveillance

Positive Controls

Quantification Standards

Negative Controls

High Positive Controls

Low Positive Controls

Sensitivity Controls

Reference Standards

Calibration Standards

Working Standards

Page 21: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

• Performance Evaluation

• Stability

• Controls

• Quality Control

• Post Market Surveillance

Reagents

Kits

Page 22: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control - Specificity

Pos. Control / QS

NTC Neg. Matrix Eluate

Page 23: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control – Standard Curve

Pos. Control / QS

NTC Neg. Matrix Eluate

Page 24: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control - Slope

Pos. Control / QS

NTC Neg. Matrix Eluate

Page 25: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control – Ct-values

Pos. Control / QS

NTC Neg. Matrix Eluate

Page 26: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control - Fluorescence

Pos. Control / QS

NTC Neg. Matrix Eluate

Page 27: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control - Sensitivity

Pos. Control / QS

NTC Neg. Matrix Eluate

Sensitivity Control

Page 28: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control - Trueness

Pos. Control / QS

NTC Neg. Matrix Eluate

Sensitivity Control High Pos. Control

Low Pos. Control

Page 29: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control – Internal Control

Pos. Control / QS

NTC Neg. Matrix Eluate

Sensitivity Control High Pos. Control

Low Pos. Control

Page 30: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Reliability

Quality Control – Reagents / Enzyme

Enzyme lot A: pos. Control - sensitivity control - NTC Enzyme lot B: pos. Control - sensitivity control - NTC

Page 31: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Diagnostic Markers in Filovirus Infections

Page 32: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Filovirus Infections – Diagnostic Markers

Marburg virus patients

BEBOV

Page 33: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

When does testing make sense and how do you interpret the results?

Page 34: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Diagnostic Technologies

Page 35: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Isothermal amplification

High and low temperature methods: NASBA, RPA, LAMP, SDA, … Advantages

No cycler needed Fast Cheap

Disadvantages

Unspecific detection and unreliable (LAMP) If used for real-time detection, more sophisticated instrumentation/software

needed. Multiplexing? Internal Control? More complicated assay design – higher conservation of sequences

Page 36: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

RPA for Ebola and Marburg Detection

Sensitivity similar to real-time RT-PCR Target gene for RPA: NP Parallel assays for EBOV, SUDV, MARV 1 and MARV 2 “Lab in a suitcase”

http://www.dpz.eu/de/startseite/einzelansicht/news/labor-im-koffer-zu-ebola-entwickelt.html

Page 37: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Polymerase Chain Reaction (PCR)

Agarose gel PCR Risk of contamination Integration of Internal control difficult No multiplexing No quantitation …

Real-Time PCR Instrument requirements Less prone to contamination Multiplexing Quantitation …

Page 38: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Real-Time RT-PCR

Observation of reaction kinetics allows quantification.

Gel detection will show different band intensity

Cycles

96 replicates

real-time PCR-detection

Page 39: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Assays with FDA Emergency Use Authorization

Page 40: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Roche and TibMolbiol

LightMix® Ebola Zaire rRT-PCR Test Zaire ebolavirus specific Internal control FDA Emergency Use Authorization Inactivated virus used Discussion: PCR indeterminate or negative?

Page 41: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Roche and TibMolbiol

LightMix® Ebola Zaire rRT-PCR Test Zaire ebolavirus specific Internal control FDA Emergency Use Authorization Inactivated virus used Discussion: PCR indeterminate or negative?

Page 42: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

BioFire

Specific for Zaire ebolavirus Two versions both with FDA EUA FilmArray NGDS BT-E Assay FilmArray Biothreat-E test “The EUA for the FilmArray Biothreat-E test enables hospitals with laboratories that fit these characteristics to conduct a PCR test for Ebola in-house, without having to send the sample to an outside lab” Analytical sensitivity: 10e+4 PFU/ml (inactivated virus) Live virus is at least 10 x better:

Page 43: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Department of Defense and CDC Assays

DOD: Zaire ebolavirus specific CDC: Zaire ebolavirus specific

100 µl sample in 90 µl eluate ~ 650 TCID50/ml

Page 44: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Department of Defense and CDC Assays

DOD: Zaire ebolavirus specific CDC: Zaire ebolavirus specific

100 µl sample in 90 µl eluate ~ 650 TCID50/ml

External inhibition controls

Page 45: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

altona Diagnostics

RealStar Ebolavirus RT-PCR Kit 1.0 (derivative of the Filovirus Screen kit) internal control

Page 46: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

EUA Sensitivity Data

Assay PFU/ml (TCID50/ml) Geq/ml

DOD 1,000 ?

CDC NP (6,500)

CDC VP40 (650)

Biofire 1 10,000* 436,000

Biofire 2 600,000* ?

LightMix 4,781* ?

RealStar 1 3,500

* Inactivated gamma irradiated virus

Forget these data and wait for international standard…

Page 47: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Other PCR Kits

Fast-Track Zaire specific (CE-IVD) No access to validation files

Genesig / Primerdesign Zaire specific (RUO) No validation data available

Bioneer AccuPower® EBOV Real-Time RT-PCR Kit (RUO) Zaire specific ~46 copies/rxn (LoD 95%)

altona Diagnostics GmbH RealStar Filovirus Screen RT-PCR Kit (CE-IVD, WHO prequal.) pan-filovirus sensitivity species dependent (~10-70 copies/rxn)

Page 48: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Other PCR Kits

Lipsdiag Zaire and Sudan Kits (RUO) No validation data

Liferiver Zaire specific (CE-IVD) LOD 1,000 copies/ml (“depending on extraction”)

Sacace Ebola Zaire (RUO?) No validation data

Page 49: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Rapid Tests

Page 50: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Why Rapid Tests

Models show diminished infection rates

Page 51: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

Bell et al. Nature Reviews Microbiology 4, S7–S20 (September 2006) | doi:10.1038/nrmicro1525

Page 52: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Rapid Tests

Find and WHO defined a “wish list” for rapid simple tests Clinical sensitivity >95% Clinical specificity >99% Corgenix ReBOV is prequalified by WHO What will you do with a result like this?

Page 53: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Rapid lateral Flow Systems

?

?

?

? ? More?

Page 54: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Cepheid gene Xpert

Expensive Equipment Powersupply

Similar to BioFire

Page 55: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)

always a drop ahead.

Future Diagnostics

Several systems (pouches, cartridges, chips) are currently under development…

Page 56: e-mail info@altona-diagnostics.com Laboratory Diagnostics ... · always a drop ahead. Introduction . Stephan Ölschläger altona Diagnostics GmbH, Hamburg, Germany (since April 2013)