ACTIVE REMEDIATION 2F.A.P. Plus™ 2
Electrical Skimmer 6
PASSIVE REMEDIATION 7Passive Skimmer 7
SoakEase™ 8
SUBMERSIBLE PUMPS 10MVP Series 10
Evacuator™ II 14SEP IV Electric 16
Level Controllers 18
SOLAR REMEDIATION 20SolarNAPL 20
SolarSparge 21
LOW FLOW SAMPLING 22Mini Bladder Pump 22
Sample Plus™ Pump 23Peristaltic Pump 24
GROUND WATER PURGING 24Peristaltic Pump 24
DC Pumps 25Arch™ Pump 26
SUPPORT EQUIPMENT 26
INSTRUMENTATION 28Water Level Indicators 28
Product/Water Probe 29
ANNEX 30Index 35
Groundwater Sampling and Remediation 2006
DURHAM GEO SLOPE INDICATOR
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
ACTIVE REMEDIATION
2
F.A.P. Plus™ Pump SystemDURHAM GEO SLOPE INDICATOR
F.A.P. Plus™ Pump System Active pneumatic skimming system for
product recovery
Application❖ LNAPL Recovery.❖ DNAPL Recovery.
❖ 2 inch or larger wells.❖ Recover a wide range of products from
light-
end hydrocarbons to more viscous products such as #6 heating
oils.
Description
The F.A.P. Plus™ Pump system is comprised of seven main
components: ■ F.A.P. Plus™ Pump ■ Skimmer Assembly ■ Well Clincher
■ Filter/Regulator (not shown) ■ Pneumatic Overfill Protection
Device ■ Electric Air Compressor (not shown) ■ Hoses (not shown)
Options: ■ SolarNAPL Compressor ■ F.A.P. HF
ACTIVE REMEDIATION
■ F.A.P. Plus™™ Pump (TR-516)
The F.A.P. Plus™ Pump consists of a flexible, special inner
bladder and a flexible Buna-N® hose which forms the outer pump
body. The integral controller is housed inside the stainless
chamber and is factory preset for 15 cycles per minute. This
provides the optimum pumping rate.
The pump operates by alternately inflating and deflating the
annular space between the inner bladder and the outer hose. When
compressed air is applied, the inner bladder collapses. When the
air is exhausted, the inner bladder rebounds to its original shape
thereby causing a suction which pulls fluid into the pump and up to
the surface. The pump utilizes two check valves to maintain the
suction and prevent the fluid from flowing back into the well. The
pump is capable of producing a suction of 17 in of mercury for the
recovery of viscous product and operation in deep wells up to 200
feet.
The F.A.P. Plus™ can operate dry or in the coiled position
without damage. It may be installed at the surface in shal-low well
applications.
■ Skimmer Assembly
The skimmer is attached to the bottom of the F.A.P. Plus™ pump
and is used to separate the product from the water in the well.
Depending on your site conditions, three types of skimmers are
available: standard, high viscosity and density skimmers. The
following table will help you select the proper skimmer for your
site.
Viscosity 80 SSU or less Higher than 80 SSU
D from BW to PWI ≥ 24” ≥ 18” ≥ 18” 6"
Water Table Flu < 36” < 24” < 30” < 24"
Well Diameter ≥ 2” ≥ 2” 4" 2"
Part Number TR-517 TR-51711 TR-70410 TR-702
Skimmer Type Standard 36" travel
Standard 24" travel
High Viscosity Density
Tech Tip: The high water shut off can be added to the TR-517,
TR-51711 and the TR-70410 to insure water is not recovered should
the water table change exceed the skimmer travel.
Standard Skimmer (TR-517). The standard skimmer is used to
recover gasoline, jet fuel and most diesel fuels. It combines a
density float, a special hydrophobic element, a product bypass, a
hollow guide rod and a coiled hose. The center guide rod allows the
skimmer to travel freely in
Tech Tip: For recovery of sinkers, the DNAPL skimmer (TR-519)
attaches to the bottom of the F.A.P. Plus™ Pump.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
Section1
3
ACTIVE REMEDIATIONF.A.P. Plus™ Pump System
DURHAM GEO SLOPE INDICATOR
id from the bottom of the well to the water/product interface.
These skimmers have a specific gravity of 0.95 and float in the
water with the top inlet just above the product/water in-terface.
The skimmers have an effective travel of 24 inches. The 2 in and 4
in sizes are for use in well casings with these nominal inside
diameters. The 6 in and 12 in mod-els are self-supporting and may
be used in large diameter wells, open excavations and open water
applications. High Water Shut Off (TR-51710). This option can be
used on all the rod skimmers, TR-517, TR-70410 and TR-51711. It is
used when the water table changes are expected to ex-ceed the
travel of the skimmer. When the skimmer reaches its upper travel
limit and is submerged in water, the pneu-matic logic shuts down
the pump and will restart the pump
response to the water table changes. The skimmer is de-signed to
float with the inlet positioned at the water/product interface
automatically providing 36” of skimmer travel. The density float is
used to position the special hydrophobic ele-ment — the skimmer
inlet — at the product water interface. The hydrophobic element
uses a special micron pore size that is based on surface tension,
allowing only product to pass. A larger pore size is available for
use with higher vis-cosity products such as weathered diesel.
Pumping rates through the hydrophobic element will be approximately
100 gallons per day.
Tech Tip: The larger micron-sized elements may allow a small
percentage of water to pass.
The bypass element is attached to the top of the hydropho-bic
element and allows the product to enter the skimmer directly when
the product layer is greater than 2 inches. Re-covery rates through
the bypass element are approximately 300 gallons per day.
The complete skimmer element is connected to the bottom of the
guide rod by a coiled polyurethane hose. This coiled hose can
accommodate water level changes of up to 36 in automatically
maintaining the skimmer intake at the wa-ter/product interface. A
minimum distance of 24 in from the bottom of the well to the
water/product interface is required when using the TR-517. The
TR-51711 requires a minimum of 18 in and provides 24 in of travel.
The skimmer can also be configured as a passive device by attaching
a quick connect canister on the bottom of the skimmer, providing
greater flexibility for free product recov-ery projects. (see
Passive Skimmer on page 9).
Maintenance: Biofouling may occur because the hydro-phobic
element is positioned at the air/product interface. If fouling
occurs, the element can be cleaned using a soft brush or replaced
by unthreading the bypass element and installing a new hydrophobic
element.
High Viscosity Skimmer (TR-70410). This skimmer is used when the
product has a viscosity higher than 80 SSU, such as oils. The 4 in
high viscosity skimmer uses the same design as the TR-517, less the
hydrophobic and bypass elements. The skimmer has a 30 in travel and
a specific gravity of 0.95, allowing it to float at the water/
product interface. The product collects on the top of the skimmer
inlet and, from there, is pumped to the surface. In normal
applications the skimmer will remove product down to a ¼ in to ½ in
product layer. The skimmer can be adjusted in the field to remove
the product even further and attain a thinner layer.
Density Skimmers (TR-704, TR-706, TR-712). Density skimmers are
used when there is less than 18 inches of flu-
F.A.P. Plus™ Typical Installation
Air In
2 in. Well Clincher
TR-762
FAP Plus™Pump
TR-516
ProductBypass
HydrophobicElement
SkimmerAssembly
TR-517
DensityFloat
Air Compressor inNon-Explosive Atmosphere
TR-901
Product Storage Tank
PneumaticOverfill Device
TR-757
Filter/RegulatorAssembly
TR-748
Air
AirExhaust
DischargeOut
Floating Product
Groundwater
High WaterShut Off
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
ACTIVE REMEDIATION
4
F.A.P. Plus™ Pump SystemDURHAM GEO SLOPE INDICATOR
when the skimmer returns to its normal operating position.
Tech Tip: It is important to ensure that water table level
changes do not exceed the travel of the skimmer, or water could be
collected. The High Water Shut Off, TR-51710, should be con-sidered
in these applications. When installing the system, it is also
important to account for the rise in the water table due to removal
of floating prod-uct. Water tables can rebound over 20% when
product is removed.
■ Well Clincher
The Well Clincher has expandable, pass-through fittings for the
air supply and fluid discharge hose, allowing the pump to be easily
adjusted. The Well Clincher seals the well from debris and is
available for wells with diameters from 2 to 8 in.
■ Filter/Regulator
The regulator allows the pump operating pressure to be set
ac-cording to the depth of the pump. A minimum of 60 psi is
required to operate the F.A.P. Plus™ pump properly. The filter
regulator is included with each F.A.P. Plus™ pump.
■ Pneumatic Overfill Protection Device
This device is installed on the recovery tank or drum to prevent
overfilling the product storage vessel. The overfill de-vice is
installed on the storage vessel and will thread into a standard 2
in bung. The main air is supplied to the inlet side of the overfill
device and the outlet air supply to the F.A.P. Plus™ pump. The
overfill device senses a pressure differential when the storage
vessel is nearly full and shuts off the air supply to the F.A.P.
Plus™ pump. The standard overfill device can be used with three
F.A.P. Plus™ pumps. The TR-75711 is used with more than three
F.A.P. Plus™ pumps.
Electro-Pneumatic Overfill Protection Device
This device uses an intrinsically safe float sensor to shut off
the air supply to the F.A.P. Plus™ pump. It includes a programmable
24 hour timer to allow on/off time settings in 15 minute
increments. A 115 V power supply is required.
■ Air Compressors and Membrane Dryer
An electric, non-explosion-proof 2.5 hp, indoor-use air
compressor producing 4.2 scfm is supplied with the stan-dard F.A.P.
Plus™ Pump System (TR-515). This compres-sor can be used with up to
three F.A.P. Plus™ systems. A 5 hp compressor is available for use
with more than three systems. If other air sources are used, they
should include a 5 micron coalescing air filter. In freezing or
high humidity conditions, an air dryer is required to avoid system
dam-age. The Membrane Dryer (TR-749) is a good choice for use with
the F.A.P.™ System. The F.A.P. Plus™ pump requires relatively dry
air for optimum performance. Refer to line sizing chart on page
33.
■ Hoses
The standard hose size from the outlet side of the filter
regulator to the F.A.P. Plus™ pump is a ¼” Push-Lok™ fitting and a
3/8 in barb fitting on the air inlet side. The standard F.A.P.
Plus™ fluid discharge line has a 3/8 in barb fitting. The hose
sizes may have to be increased depending on the distance between
the system components.
How do I select the most appropriate skimming system? The most
important elements in choosing the F.A.P. Plus™ system will be your
water table fluctuations, prod-uct viscosity, type of product, well
diameter and amount of product present. You can find the complete
design data sheet on our web site to define all of your site
conditions.
Tech Tip: The F.A.P. Plus™ requires a minimum of 60 psi for
optimal performance
Options
■ SolarNAPL — Solar-powered air compressor config-ured to drive
an optional F.A.P. Plus™ pump. See page 6 for details.
■ F.A.P. HF — To pump at higher flow rates (up to 2.2 gpm) with
a suction of 17 in Hg at the inlet. See page 13 for details.
Well clincher and filter regulator in simple field
installation.
TR-757
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
Section1
5
ACTIVE REMEDIATION
ORDERING INFORMATIONTR-515 2 in F.A.P. Plus™ Pump System.
Includes:
Pump, F.A.P. Plus™ Skimmer, 2.5 hp com-pressor, 2 in Well
Clincher, Pneumatic Overfill Protection Device. 50 ft suspension
kit.
175 lb
TR-51504 4 in F.A.P. Plus™ Pump System. Includes: Pump, F.A.P.
Plus™ Skimmer, 2.5 hp com-pressor, 4 in Well Clincher, Pneumatic
Overfill Protection Device. 50 ft suspension kit.
175 lb
TR-51506 6 in F.A.P. Plus™ Pump System. Includes: Pump, F.A.P.
Plus™ Skimmer, 2.5 hp com-pressor, 6 in Well Clincher, Pneumatic
Overfill Protection Device. 50 ft suspension kit.
175 lb
TR-514 2 in F.A.P. Pump System. Same as TR-515 without
compressor
25 lb
TR-5104 4 in F.A.P. Pump System. Same as TR-51504 without
compressor
25 lb
TR-5106 6 in F.A.P. Pump System. Same as TR-51506 without
compressor
25 lb
Components:TR-516 F.A.P. Plus™ Pump and Filter Regulator 12
lb
TR-517 F.A.P. Plus™ Skimmer, 36 in travel. Minimum depth of 24
in required*
5 lb
TR-51718 F.A.P. Plus™ Skimmer, 18 in travel.Minimum depth of 14
in required*
5 lb
TR-51711 F.A.P. Plus™ Skimmer, 24 in Travel.Minimum depth of 18
in required*
5 lb
TR-51710 High-Water Shut-Off 3 lb
TR-702 F.A.P. Plus™ Density Skimmer (1.65 in dia.) 3 lb
TR-704 F.A.P. Plus™ Density Skimmer (3.5 in dia.) 3 lb
TR-706 F.A.P. Plus™ Density Skimmer (5.5 in dia.) 3 lb
TR-712 F.A.P. Plus™ Density Skimmer (11.5 in dia.) 3 lb
TR-70410 4” High Viscosity Density Rod Skimmer (30 in
Travel)
8 lb
TR-519 DNAPL Skimmer 4 lb
TR-757 Pneumatic Overfill Protection Device 4 lb
TR-75711 Pneumatic Overfill Protection Device for 3 or more
pumps
8 lb
TR-758 Electro-Pneumatic Overfill Protection Device with 24 hr
programmable timer
10 lb
TR-762 2 in Well Clincher 1 lb
TR-764 4 in Well Clincher 1 lb
TR-766 6 in Well Clincher 1 lb
TR-768 8 in Well Clincher 1 lb
TR-748 Filter / Regulator 2 lb
TR-734 3/8 in ID Buna-N® hose .25 lb
TR-735 1/4 in OD polyethylene tubing .25 lb
TR-732 1/2 in Buna-N® hose .25 lb
918702 Suspension Cable .25 lb
TR-749 Membrane Dryer. Reduces dew point to -4°F 9 lb
TR-901 Air Compressor, 2.5 hp 150 lb
903801 Hydrophobic Replacement Element (std.) 3 lb
903801B 250-micron Hydrophobic Element 1 lb
* from bottom of well to product/water interface.
F.A.P. Plus™ Pump SystemDURHAM GEO SLOPE INDICATOR
SPECIFICATIONS
TR-516 F.A.P. Plus™ Pump SystemSize and Weight 1.75 in OD by 59
in long. 6 lb
Air Requirements 0.5 cfm at 100 psig (2.8 dm³ at 690 kPa)
Operating Pressure 60 to 100 psig
Pump Capacity 15 - 20 gal/hr at 10 ft DTH10 - 15 gal/hr at 100
ft TDH Based on gasoline through 3/8 in ID hose.
Max. Viscosity Contact Factory
Suction 17 in Hg
Materials Flexible Buna-N® (outer bladder)Tygon® Special (inner
bladder)Brass, stainless steel
Air Supply to Pump 1/4 in OD polyethylene
Fluid Discharge 3/8 in ID Buna-N® hose
TR-517 F.A.P. Plus™ SkimmerSize 1 ¾ in OD x 67 in long. Fits 2
in and larger wells
Materials UHMW polyethylene, stainless steel, urethane tubing,
hydrophobic material, nitrophyl float, brass fittings and PVC
Float UHMW polyethylene, S.G. 0.95Up to 36 in effective
travel
TR-702/704/706/712 F.A.P.™ Density SkimmersSizes (Diameter)
1.65, 3.5, 5.5, or 11.5 in
Materials
Float UHMW polyethylene, S.G. 0.95
Inlet Screen Stainless Steel Mesh
Coil Polyurethane tubing
Effective Travel up to 24 in
TR-757 All-Pneumatic Overfill Protection DeviceSize 4 x 4 x 20
in
Enclosure Fiberglass
TR-758 Electro-Pneumatic Overfill Protection DeviceEnclosure
NEMA 4 rating; solid state GEM Pak® circuitry.
8 x 6 x 4 in
Pneumatic Valve 23 scfm at 100 psi
Float Switch Intrinsically safe; w/ 100 ft cable
Voltage 110 V (ac)
Power Cord 8 ft
Timer Provides 24 hr time-delay operation
TR-748 Filter RegulatorFilter Coalescing, 5 micron with auto
drain
TR-762/764/766/768 Well ClincherMaterials PVC flat top cap with
plastic fittings
TR-901 Air CompressorSize 2.5 hp, 4.2 cfm oil lubricated. 115 or
230 V.
20 gal, ASME code steel tank
Download datasheets, manuals, and technical notes from
www.durhamgeo.com
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
ACTIVE REMEDIATION
6
ESS Electrical Skimmer SystemDURHAM GEO SLOPE INDICATOR
ESS Electrical Skimmer System Electric skimming system for
product recovery.
Application❖ LNAPL Recovery.❖ DNAPL Recovery.❖ 4 inch or larger
wells.
Tech Tip: For 2 in wells, the pump can be mounted at the well
head.
Description
■ Explosion proof Skimmer Pump ■ Nema 4 Control Panel ■
Skimmer
■ Electric Skimmer Pump (TR-104). The ESS skimmer pump is a
linear dual solenoid reciprocating piston pump that uses an
internal piston and dual check valves to create suction
transferring the product from the skimmer to the surface. The pump
is equipped with a standard 100-foot power cable with NEMA 6P rated
connections. The pump has a maximum depth capacity of 90 feet and
can pro-duce flow rates up to 150 gal/day. The discharge hose
connection is a 3/8 in barb fitting. The pump itself is rated
explosion proof and must be installed to Class 1 Division 1
electrical codes to maintain this rating.
■ Skimming Pump Controller (TR-105 Series). It is used to
control the run times for one to three skimmer pumps. The
controller has three independent 24-hour timers with options for:
Manual Pump Off, Manual Pump On, Auto Off cycle timer and Auto On
cycle timer. To simplify operations, the pump run time is set based
on the recovery rate of each well. When used in the auto cycle
mode, the pump timer must be set allowing a 50% off time compared
to the on or run time to maintain optimum pump life. The controller
is housed in a NEMA-4 enclosure and is not rated explosion proof;
therefore, it must be located outside the explosion rated area. The
controller includes the tank overfill device and will operate on
110 V, 60 Hz or 230 V, 60/50 Hz.
■ Standard Skimmer (TR-517). The standard hydrophobic skimmer
attaches directly to the bottom of the pump via a quick connect
fitting and provides 36 inches of automatic skimmer travel. The
pump uses the same skimmer as the F.A.P. Plus™ system. The standard
TR-517 skimmer is used for product with SSU values smaller than 80
. For values greater than 80 SSU, the TR-70410 must be used.
SPECIFICATIONS
Size and Weight 3.6 in OD x 4 in Long. 4.8 lbOutput Pressure 45
psig max.Pumping Capacity 33 gal/hr max.Max. Fluid Viscosity
Contact FactorySuction 25 in HgSystem Pressure 1400 psig
max.Materials Stainless steel and Flourel,
Neoprene® or EPDMFluid Connections 3/8 in NPTPower 120 V 60
Hz
80 - 130 W continuous duty
ORDERING INFORMATION
TR-104 4 in Electric Skimmer Pump w/ 100 ft Power Cable
14 lb
TR-105 Skimming Pump Controller w/ Timer and Tank Overfill
Protection Device. 1 Pump
12 lb
TR-1052 Skimming Pump Controller w/ Timer and Tank Overfill
Protection Device. 2 Pumps
12 lb
TR-1053 Electric Pump Controller w/ Timer and Tank Overfill
Protection Device. 3 Pumps
12 lb
TR-517 Standard Skimmer, 36 in Travel 6 lbAccessories:TR-70410 4
in High Viscosity Rod Skimmer 8 lbTR-734 3/8 in ID Buna-N® Hose
(Discharge) .25 lbTR-762 2 in Well Clincher 1 lbTR-764 4 in Well
Clincher 1 lbTR-766 6 in Well Clincher 1 lbTR-768 8 in Well
Clincher 1 lb
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
Section1
7
ACTIVE REMEDIATION
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
Section1
7
PASSIVE REMEDIATIONPassive Skimmer
DURHAM GEO SLOPE INDICATOR
Passive SkimmerFloating inlet automatically adjusts to water
table changes.
Application❖ Passive LNAPL recovery❖ Use when minimal product is
present or slow
recovery rates are expected❖ 2 in and larger wells❖ May be
upgraded to an active system by add-
ing the F.A.P. Plus™ Pump.
Description
■ Skimmer ■ Canister ■ Well Clincher with 30 ft cord
■ Skimmer. The Passive Skim-mer utilizes the F.A.P. Plus™
skimmer to provide a 36 in floating intake for the recovery of free
phase products such as gasoline, diesel and jet fuel. It is used
when minimal product is present or slow recovery rates are
expected. For passive recovery of products with higher than 80 SSU,
the 4 in high viscosity skimmer (TR-25410) is used. This system
provides a floating intake of 30 inches. ■ Product Recovery
Canister. The clear PVC collection canis-ter uses a quick connect
fitting to attach it to the skimmer and provides venting through
the skimmer support hollow rod. The bottom of the canister
incorpo-rates a petcock for easy draining. The petcock assembly can
be removed allowing an extension canister to be threaded into the
existing canister to increase the volume of free product that can
be recovered. Additional weights are included with each canister
and must be used for proper installa-tion.
SPECIFICATIONS
2" Model 4" ModelLength 93.5 in 93.5 inOutside Dia. 1.75 in 3.5
inEffective Travel 36 in
(30 in for High-Viscosity Skimmer)Canister Volume 0.13 gal 0.45
galCanister Length 24 in 15 inMin. Water Depth 50.5 inWeight 4 lb 6
lbExtension Canister
Length18 in 16.5 in
Extension Canister Volume
0.10 gal(Additional)
0.52 gal(Additional)
Materials UHMW polyethylene, stainless steel hollow rod and
clamps, urethane tubing, polyethylene hydrophobic filter, Nitrophyl
float material, brass fittings, PVC tubing mouldings.
ORDERING INFORMATION
TR-252 2 in Passive Skimmer 4 lbTR-253 2 in Extension Canister 1
lb
TR-254 4 in Passive Skimmer 6 lbTR-25410 4 in Passive Skimmer
(High-Viscosity ) 6 lbTR-255 4 in Extension Canister 2 lbParts
required to convert a Passive Skimmer into an Active Skimming
System:TR-516 F.A.P. Plus™ Pump 6 lbTR-762 2 in Well Clincher 1
lbTR-764 4 in Well Clincher 2 lb
301822 1/4 in Brass Plug .25 lb301139 Push-Lok Fitting .25
lb
■ Well Clincher and Cord. The Well Clincher and 30 ft Nylon®
suspension cord are used to support the passive skimmer in the
recovery well. The clincher incorporates an eye hook to attach the
suspension cord. Correct measure-ment of the product water
interface is necessary to properly position the passive
skimmer.
Tech Tip. The critical measurement for proper recovery is from
the bottom of the well to the product water interface. Custom
canisters are available for shallow well applications.
PASSIVE REMEDIATION
TR-252
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
PASSIVE REMEDIATION
8
SoakEase™ DURHAM GEO SLOPE INDICATOR
SoakEase™ Absorbent material for immediate response or minimal
product.
Application❖ Passive LNAPL Recovery.
Description
■ 36 in Canister ■ Absorbent Socks for 1, 2 and 4 in
Canisters
SoakEase™ is a product-selective absorbent sock housed inside a
stainless steel canister. It is used as a passive collection system
for free phase product such as jet fuel, gasoline or diesel fuel
from 1.25 in and larger recovery wells, monitoring wells and
recovery trenches.
The SoakEase™ can be used as a bailer for periodic product
removal or as a dedicated system for a more continuous method of
recovery. Prior to dedicating the SoakEase™, it is recommended that
excess free product be removed by bailing with the SoakEase™.
To use SoakEase™ as a bailer, an absorbent sock is placed in the
stainless steel canister; a cord is attached to the support loop
and then lowered through the product layer. The full length of the
sock should come into con-tact with the product for greater
recovery. Immediately, the SoakEase™ will begin absorbing product
at a rate of approximately 0.1 gallon per second, depending on the
product viscosity. After some time, the SoakEase™ should be raised
from the well; the sock removed from the canister and disposed of
in accordance with regulations.
To use the SoakEase™ as a dedicated system, deter-mine the
amount of product present and the water table fl uctuation using
the PWI interface meter (TR-921). When these have been determined,
the SoakEase™ may be installed to accommodate level changes up to
36 in.
Tech Tip: The product absorption rate is de-termined by the
viscosity of the product and can vary depending on site conditions.
The SoakEase™ is designed to be used with hydro-carbon-based
products. The user must determine the necessary replacement
schedule by gauging site conditions. The socks can be squeezed out
and reused. Approximately 80% of the original absorption can be
recovered.
SPECIFICATIONS
Size Designation 1 in 2 in 4 inOutside Diameter 1.0 in 1.7 in
3.5 inLength 3 ft 3 inWeight (Net) 1.8 lb 3.0 lb 6.0 lbCanister
Material Stainless Steel Type 304, perforatedAbsorbent Sock
Material
Polypropylene fi brous material contained in a white fabric
sock
Rated Absorption1 in Socks 0.67 US gal per case ( 0.18 qt per 1"
sock)2 in Socks 3 US gal per case (1 qt per 2" sock)4 in Socks 9 US
gal per case (3 qt per 4" sock)
Incompatibility Slight degradation may occur if exposed to
strong oxidizing agents
Warning Not recommended for use with aggressive fl uids,
including strong acids, strong bases, oxidizers and hazardous
materials
Reaction time Immediate
ORDERING INFORMATIONTB1-100 1 in SoakEase™ Kit. Includes:
(1) 1 in Canister w/ Absorbent Sock(15) Absorbent Socks
7 lb
TB1-101 1 in Canister 2 lb
TB1-110 1 in SoakEase™ Refi ll (case of 12) 4 lbTB2-100 2 in
SoakEase™ Kit. Includes:
(1) 2 in Canister w/ Absorbent Sock(15) Absorbent Socks
7 lb
TB2-101 2 in Canister 2 lbTB2-110 2 in SoakEase™ Refi ll (case
of 12) 4 lbTB4-100 4 in SoakEase™ Kit. Includes:
(1) 4 in Canister w/ Absorbent Sock(4) Absorbent Socks
8 lb
TB4-101 4 in Canister 3 lb
TB4-110 4 in SoakEase™ Refi ll (case of 12) 7 lb
Rev
. 01/
08
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
Section1
9
ACTIVE REMEDIATION
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
Section1
9
PASSIVE REMEDIATIONDURHAM GEO SLOPE INDICATOR
Petro-Bailer™ Low-cost passive skimmer with a fixed product
inlet.
Application❖ Passive LNAPL Recovery.❖ 2 in and larger wells
Description
The Petro-Bailer™ comprises: ■ Top cap with a stainless loop ■
Hydrophobic inlet filter element ■ Collection reservoir ■ Weighted
end point
The fixed inlet passive skimmer is made from threaded PVC
components and is designed to collect free phase product from 2 in
and larger wells. The hydrophobic inlet filter element connects
between the body and top cap. The passive skimmer will accommodate
water table fluctuations of up to 12 inches. The device will
collect water if level fluctuations are greater than 12 in.
SPECIFICATIONSSize 61.5 in long x 1.66 in diameterVolume 0.21
galWeight (Net) 3.25 lbDepth 41.5 in water (minimum for
skim)Materials PVC body, end point and top. Porous poly-
propylene fiber element, 12 in stainless steel suspension loop,
Buna-N® "O" Rings
ORDERING INFORMATIONTR-007 2" Petro-Bailer™ (1.66 x 61.5 in) 4
lbTR-008 Petro-Bailer™ Weighted EndTR-009 Petro-Bailer™ Replacement
ReservoirTR-010 Petro-Bailer™ Replacement Hydrophobic ElementTR-011
Petro-Bailer™ Replacement Top
TopCap
Filter
Body
EndPoint
www.DurhamGeo.comAlways up to date.
Because we strive to constantly improve our products, our
offerings may have changed since the publication of this catalog.
Please consult our web site for the latest and most complete
information including data sheets, manuals and miscellaneous
technical notes.
Save time!Download data
sheets, catalogs, forms and software.
Go to www.DurhamGeo.com and select "Down-loads" from the menu
bar on the left, and you should see a page resembling the one shown
below.
Save more time by shopping online!
There is a convenient link on our Home page (www.DurhamGeo.com).
We even have a Quick Order Form for those who know the part number
they wish to order and and a quick get-in-and-get-out solution.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
10
MVP SeriesDURHAM GEO SLOPE INDICATOR
MVP IV Pump
Description
The MVP IV pump kit includes: ■ MVP IV Pump ■ Well Clincher
(well cap) ■ Air Particulate Filter Regulator
■ The MVP IV Pump uses an internal float that responds to the
fluid level within the pump body to cycle the pump automatically,
based on the recharge of the well. As the pump fills with fluid,
the float moves to the upper position, activating the mechanical
arm which opens the air inlet valve. This allows air to enter the
pump chamber, simulta-neously pressurizing the vessel and closing
the upper and lower inlet check valves. As a result, the fluid
moves to the surface. As the fluid is emptied from the vessel, the
float returns to the lower limit — off position — closing the air
inlet and opening the air exhaust valve. During the filling cycle,
air is vented through the exhaust port and the cycle is
automatically repeated. The thread together design provides
complete access to all the internal components. This makes it
possible to change pump loading configura-tions easily. The pump
head can be easily removed should access to the air inlet and
exhaust valves be needed.
Positive Valve ShiftingThe air inlet and air exhaust valves are
incorporated on the same side of the pump to impart a mechanical
advantage which makes the valve shift fully and reliably. This
lever-age is seven times greater than would be available if the
valves were located on opposite sides of the pump head.
MVP IV Series Pneumatic PumpsControllerless air lift pump
ApplicationControllerless ground water pump for use in 4 inch
and larger diameter wells and up to 200 feet depths for:❖ Dissolved
Phase❖ Total Fluids
❖ Plume Control
❖ Dewatering❖ Leachate
SUBMERSIBLE PUMPS
The new free-float-ing actuating arm ensures a positive air
valve shift. The design permits the use of larger and simpler air
exhaust valves to eliminate air quality and stalling concerns. The
poppet design valves provide a larger surface area improving air
efficien-cies. Every MVP IV pump includes the override feature
allowing the pump and discharge line to be emptied from the surface
reducing the pump’s weight during its removal. An additional ¼ in
air line is required.
Tech Tip: Maintenance of the MVP IV pump will vary based on site
conditions. For sites with high mineral concentrations, it may be
necessary to remove the pumps periodically to clean the min-eral
deposits.
The MVP IV features an all-stainless steel linkage system with
Teflon® bushings with a synthetic glass resin float to insure
reliability and chemical compatibility. Stainless steel floats are
optional. For added durability, all MVP IV pumps have a stainless
steel body. The MVP IV pump uses clampless barb fittings for the
3/4 in discharge and 3/8 in air exhaust lines. The air supply uses
a 1/4 in PushLok® fitting. Quick connect fittings (TR-80910) are
available as an op-tion.
Tech Tip: In deeper applications, the size of the air exhaust
and fluid discharge lines may be increased to reduce friction loss
and increase flow rates.
Flow rates range from 8 gpm on top-loading pumps to 13 gpm on
standard pumps. Pump flow rates will be affect-ed by the amount of
head above the pump. Should lower flow rates be required, the flow
control valve TR-698 can be installed on the exhaust line of the
MVP IV pump. This will allow the user to restrict the air exhaust
which regulates the fill time of the pump. It is important to
properly size the air supply and discharge lines to accommodate for
friction loss. Refer to line sizing tables on pages 33 and 34.
Pump top with body removed to show how mechanical advantage is
achieved in the valve actuating design.
Air Exhaust
Discharge
Float
Magnet
Actuating Rod
Air Inlet
Lever
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 11
SUBMERSIBLE PUMPSMVP SeriesDURHAM GEO SLOPE INDICATOR
Loading Configurations
Top loading pumps are selected for pumping total fluids (LNAPL
and ground water simultaneously). The top loading pumps will
produce flow rates of up to 8 gpm — depend-ing on the head above
the pump. Water table draw-down will be maintained at a level
corresponding to the top inlet of the pump. Shorter length pumps
are available for lower drawdown require-ments.
Tech Tip: A skim-mer attachment (TR-810) can be threaded onto
the top inlet of the pump allowing the pump to collect product
only.
Bottom loading pumps are selected for dis-solved phase, DNAPL or
leachate applications. When installing the pump, the head is
positioned at the depth of the desired water table depression.
During start-up, the pump fills from both the top and bottom inlet
ports. As the water table de-pression zone stabilizes, the pump
will fill from the bottom only. The bottom loading pump can be
configured with a closed top to reduce the possibility of debris
entering through the inlet. This may be particularly useful in
leachate applications or applications where floating debris is
present.
View animated graphics on our web site. They show how the pumps
function. There are links on the pumps' page.
Tech Tip: Minimum submergence can be re-duced on the bottom
loading pump by install-ing the stop collar on the float actuating
rod (TR-7714). This will reduce the float travel and open the air
valve with less fluid in the pump. The top loading pump submergence
can be reduced with a short pump.
■ The Well Clincher serves as a well seal and pump support. It
simplifies hose connec-tion. A retractable handle provides for easy
instal-lation or removal of the pump system. The 90 degree fittings
on the top of the Clincher reduce the possibility of kinked hoses
in the well vault. Expandable Well Clinch-ers with pass-through
ports are available for installations requiring frequent pump
adjust-ments.
■ The Particulate Filter/Regulator should be installed at the
well head to supply the proper air pressure to the MVP IV Pump.
This will optimize air consumption. A good guideline for setting
the air pressure is 0.5 psi per foot of pump depth.
Tech Tip: Air consumption of the MVP IV pump is based on the
depth and PSI setting. For a simple calculation use 1 cfm per
gallon pumped. This is the maximum the pump will consume.
Accessories:
The Pulse Counter is used to determine the flow rate of the MVP
IV Pump. The newly designed counter is compact and is installed in
the air supply line at the well head. As the pump cycles, the
counter senses the drop in air pressure indicat-ing the pump has
cycled. The number of cycles is mul-tiplied by the volume of the
specific pump you are using to provide the flow rate. The counter
is not resetting.
The standard hose assembly (TR-777) consists of a 3/4 in Buna-N®
discharge line, a 1/4 in Nylon® air supply line and a 3/8 in
Buna-N® air exhaust line. The Buna-N® hose provides a flexible,
chemically compatible discharge line. The main air supply and fluid
discharge hoses should be properly sized to minimize head loss due
to line friction.
MVP IV Pumps. Left: Bottom Loading model Right: Top Loading
model
TR-778
TR-773
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
12
MVP SeriesDURHAM GEO SLOPE INDICATOR
MVP Pneumatic PumpLower cost alternative
The MVP Pump is identical to the MVP IV Pump except that the MVP
Pump head and bottom valve assem-blies are manufactured from
Delrin® instead of stainless steel. All other components are
interchangeable. Delrin® is a rugged, lightweight, high density
plastic that is chemically com-patible with the fluid in most
applica-tions. The MVP Pump provides a cost effective, high
performance system.
MVP LS and MVP LD Leachate and Condensate Pumps
These models are specifically designed for use in landfills
where leachate or gas condensates are recovered. They feature an
air override that allows the pump and discharge lines to be emptied
from the surface prior to pump removal. The MVP LS is a stainless
steel bottom fill pump with a closed top and stainless steel
fittings. The MVP LD is made from stainless steel and Delrin® with
a bottom fill, closed top and PVC fittings. Operation of these
pumps is identi-cal to the standard MVP IV Pumps. They can be
supplied with custom Well Clincher flanges designed to meet your
specific site requirements.
SELECTION TABLE FOR MVP SERIES PUMPS
Part Number
Designation Pump OD (in)
Pump Length (in)
Volume /cycle
(US gal)
Material Min. Sub-mergence
(in)
Pump Weight
(lb)
Max.. Flow Rate
(gpm)
Well Clincher
Air Regulator
Body Pump Head
Top Loading ModelTR-775
MVP IV
3.5
40.5
0.4 Stainless Steel
S.S.*40⅛
278
Optional Optional
TR-770 36 Included IncludedTR-775S MVP IV Shallow 35.5 35⅛ 22 7
Optional Optional
TR-802MVP 40.5
Delrin®40⅛
168
Optional Optional
TR-800 25 Included IncludedTR-802SP MVP Shallow 35.5 35⅛ 15 7
Optional Optional
Bottom Loading ModelsTR-776
MVP IV
3.5
42.5
0.4
Stainless Steel
S.S.*34
2713
Optional Optional
TR-771 36 Included IncludedTR-776S MVP IV Shallow 37.5 29 22 10
Optional Optional
TR-803MVP 40.5
Delrin®
34 1613
Optional Optional
TR-801 34 25 Included IncludedTR-803SP MVP Shallow 35.5 29 15 10
Optional Optional
TR-77714 MVP LD 42.5 11.5 -14 27 5.5 Optional Optional0.18
TR-815MVP LS
42.50.4
S.S.* 34 27 13 Optional Optional
TR-816 40.5 Delrin® 34 16 13 Optional Optional
* Stainless Steel Note: to order any of the above pumps with a
1” discharge use the part number TR-10011 as an extra line
item.
14
12
10
8
6
4
2
00 10 25 50 75 100 150 200
Pump Depth (ft)
Flo
w R
ate
(GP
M)
MVP IV Pump Performance
Flow RateBottom Loading
1.4
1.2
1
0.8
0.6
0.4
0.2
0
Flow RateTop Loading
Air
Con
sum
ptio
nS
tand
ard
Cub
ic F
eet p
er G
allo
n P
umpe
dAirConsumption
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 13
SUBMERSIBLE PUMPSMVP Series
DURHAM GEO SLOPE INDICATOR
ORDERING INFORMATION
TR-773 4 in MVP Well Clincher 2 lbTR-786 4” MVP Well Clincher w/
1” Discharge Fittings
TR-788 6 in MVP Well Clincher 4 lbAccessoriesTR-76018 Adjustable
Well Seal for MVP IV
1 in disch, 3/8 in vent, 1/4 in supply
TR-77311 MVP 4 in Well Clincher with 2 in SVE Adapter
TR-78811 MVP IV 6 in Well Clincher with 2 in SVE Adapter
TR-88810 Landfill 8 in Flange for MVP pumps
600572 Landfill 6 in Flange for MVP pumps
600066 4 in Clincher with Adjustable Fittings
TR-10011 1” Discharge Barb Fitting for MVP Pump
Common PartsTR-774 MVP Filter Regulator
TR-778 MVP Pulse Counter
TR-809 Stainless Steel Float for MVP IV
TR-769 O-Ring Kit for MVP Pump
TR-777 MVP Down Well Tubing (3/4, 3/8, 1/4 in)
TR-794 MVP Down Well Tubing Assembly (1, 3/8, 1/4 in)
TR-759 Stainless Steel Bottom Assembly for Bottom Loading
Pump.
TR-752 Assembly Converter Valve, Top Load.
918702 Nylon®-Coated Stainless Steel Cable. Sold per ft.
F.A.P. Plus™ HFFor horizontal or vertical recovery wells
Application❖ Dissolved Phase❖ Total Fluids
❖ Leachate❖ LNAPL and DNAPL (with optional skimmer)
The F.A.P. Plus™ HF can be used for horizontal or vertical
recovery of gas condensate, total fluids, LNAPL or DNAPL. This
flexible pump can provide flow rates of up to 1.2 gpm and a suction
of 17 in Hg at the inlet. These pumps may be installed in parallel,
increasing flow rates. The pump design isolates the air supply used
to cycle the pump from the liquid being recovered, a benefit in gas
condensate ap-plications. The pump may run dry without damage. For
use in 2 in or larger wells. For details and ordering information,
please consult our web site.
ORDERING INFORMATION
TR-720 F.A.P. Plus™ HF Pump 7 lb
Air E
xhaust
3/4'' Fluid Discharge
AirSupply
SuspensionCable
WellScreen
MVP IVPump
Float Assembly
MVP PUMP TYPICAL INSTALLATION
On/OffValve
FilterRegulator
Left: F.A.P. Plus™ HF, TR-720. Inset: Detail of optional inlet
screen, TR-519.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
14
DURHAM GEO SLOPE INDICATOREvacuator™ II
Loading Configurations Top loading pumps are se-lected for total
fluids applica-tions, the recovery of LNAPL and ground water
simultane-ously. Fluid enters the top inlet and the water table
will be maintained at this point. The top loading pumps will
produce flow rates up to 2.5 gpm, dependent on the head above the
pump. Bottom loading pumps are selected to pump dissolved phase
product, DNAPL or leachate. When installing the pump, the head of
the pump is positioned at the depth of the desired water table
draw- down. Bottom loading pumps will produce flow rates up to 4
gpm.
View animated graphics on our web site. They show how the pumps
function. There are links on the pumps' page. ■ The Well Clincher
is an integral part of the system and serves as a well seal, pump
support and houses the air control valve. The under-side of the
well clincher has color coded, PushLok® fittings for the air logic
line connec-tions and barb fittings for the 1/2 in air supply and
5/8 in fluid discharge hoses. A 12 in chain is provided to attach
the pump support cable. The air supply and fluid discharge lines
are easily connected to 900 fittings on the top of the clincher.
The built-in handle makes it easy to lower or remove the pump.
■ A coalescing air filter and regulator assembly is in-cluded
with each Evacuator™ II Pump system. This must be installed at the
well head
Evacuator™ II Pneumatic PumpHigh Flow Controllerless Groundwater
Pump
ApplicationFor 2 in and larger diameter wells and up to 200 ft
depths for:❖ Dissolved Phase❖ Total Fluids
❖ Plume Control
❖ Dewatering❖ Leachate
Description
The 2 in Evacuator™ II Pump System includes: ■ 2 in. Evacuator™
II Pump ■ Well Clincher for use in vacuum operation ■ 5 micron
Coalescing Air Filter/Regulator with auto- drain
■ The Evacuator™ II Pump uses down-well internal logic combined
with a small diameter float to automatically cycle the pump,
eliminating the need for additional controls at the surface. For
the 2 in diameter pumps, this logic technol-ogy allows the pump to
use a much smaller float and fewer components than those using a
mechanical type of design. Hence, this pump, with just a 33 in
length will produce flow rates up to 4 gpm in the bottom loading
configuration. As the pump fills with fluid, the float moves to the
upper position activating the pneumatic logic. This opens the air
valve located in the well clincher allowing air to pressur-ize the
chamber, closing the check valve and pushing the fluid to the
surface. When the fluid is evacuated, the float falls to the lower
position where it activates the lower logic opening the air exhaust
port. As the pump fills with fluid under static pressure, the air
is exhausted and the cycle is repeated until the water table
reaches the desired draw-down.
The Evacuator II is constructed from stainless steel with a
Nitrophyl float and Viton® seals providing chemical resis-tance for
most applications. Complete access to all internal components is
provided with the three-piece thread-to-gether construction.
Maintenance will vary based on the site conditions. Conditions with
high mineral concentrations may require routine cleaning. The
Evacuator II style pump requires good air quality and an air drier
is recommended. It is important to ensure that all air lines are
purged to remove debris prior to start-up.
Evacuator II Pumps.Left: Top Loading model
Right: Bottom Loading model
◄Top Load
Bottom Load ►
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 15
SUBMERSIBLE PUMPSDURHAM GEO SLOPE INDICATOR
to ensure proper air pressure and filtration is being supplied
to the pump. In freezing or high humidity conditions, an air dryer
may be needed to ensure correct opera-tion. The filter/regulator
attaches directly to the Well Clincher.
Tech Tip: A good guide line for setting the air pressure is 0.5
psi per foot of depth.
Hose Assembly
The standard hose assembly contains five hoses in a PVC jacket
to simplify installation. The assembly, TR-731, contains three 1/8
in Nylon air logic lines, 5/8 in Nylon fluid discharge and 1/2 in
polyethylene air supply and exhaust lines.
Evacuator™ II
SPECIFICATIONSPump Type Positive Air Displacement
Max.. Rated Depth 200 ft
Pump Vol.. per Cycle 0.18 US gal
Operating Pressure 20 - 100 psi
Minimum Fluid Level Bottom Loading: 28.5 inTop Loading: 33.5
in
Max.. Discharge Rateat 3 ft Submergence
Bottom Loading: 4 gpmTop Loading: 2.5 gpm
Max.. Operating Temp.
120ºF
Pump OD 1.75 in
Pump Length Bottom Loading: 33.5 inTop Loading: 42 in
Air Filtration 5 micron filtered, dry
Construction: stainless steel type 303 body, head, bottom,
internal discharge line and check valves. Brass hose barbs and
float stops. Nitrophyl float. Buna-N© bottom inlet valve ball. TFE
ball with stainless steel seat top inlet (top loading only) and
discharge check valves.
ORDERING INFORMATIONTR-121 2 in Evacuator™ II Pump, Bottom
Loading,
with Well Clincher and Filter/Regulator6 lb
TR-12111 2” EVACUATOR II Pump, Bottom Loading,inline control /
frl
7 lb
TR-123 2 in Evacuator™ II Pump, Top Loading, with Well Clincher
and Filter/Regulator
6 lb
TR-12311 2 in Evacuator™ II Pump, Top Loading,inline control /
frl
7 lb
Accessories:TR-731 2 in Evacuator™ II Hose Assembly with PVC
Jacket.
Sold by the foot.
920501 2 in Well Clincher for Evacuator™ II
TR-748 Coalescing Filter/Regulator
TR-778 Pulse Counter
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Pum
p R
ate
(GP
M)
0 10 20 30 40 50 60 70 80 90 100
Pump Depth (ft)
2 in Evacuator™ II Bottom Loading Pump
3
2.5
2
1.5
1
0.5
0
Pump Depth (ft)
P
ump
Rat
e (G
PM
)
0 10 20 30 40 50 60 70 80 90 100
2 in Evacuator™ II Top Loading Pump
TR-121
Air Consumption
The Evacuator II Pump exhausts the air back to the surface after
each cycle using the same air supply/exhaust line. Therefore the
greater the depth, the higher the air con-sumption of the pump will
be. The Evacuator II Pump will use approximately 1 cfm of air per
gallon pumped at depths of up to 50 ft. To determine the air
consumption, use the following guilelines: 40 psi 0.8 scfm 80 psi
1.7 scfm60 psi 1.2 scfm 100 psi 2.1 scfm
Tech Tip: To reduce air consumption the air logic valve can be
installed in the down well hose assembly above the water table.
This is especial-ly beneficial for deep application preventing the
air from being exhausted back to the well head. Please consult
Durham Geo Slope Indicator for ordering information.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
16
SEP IVDURHAM GEO SLOPE INDICATOR
SEP IV Electric Pump SystemsHigher Flows in Ground Water
Recovery
Application❖ Dissolved Phase❖ Leachate❖ Plume control
❖ Dewatering
❖ Flow rates up to 75 gpm❖ Depths up to 400 feet.
Description
The SEP IV Pump System consists of: ■ Stainless steel pump ■
Electric motor ■ Motor lead
The SEP IV is a continuous-duty electric submersible pump
designed for the withdrawal of contaminated groundwa-ter or
leachate in environmental applications. The pumps require a control
mechanism such as the Septek to maintain the desired draw-down
level.
■ Stainless Steel Pump
The SEP IV pump ends are constructed of 304 stainless steel to
provide chemi-cal compatibility for typical environmen-tal
installations. Standard pump ends are supplied with durable PBT
(polybu-tylene terephtalate) seals for chemical resistance in most
cases. PBT seals are not recommended for use with chlorinat-ed
solvants in which case Teflon® seals are recommended. PBT seals
generally provide better wear resistance than Tef-lon®. DGSI
Teflon® seal kits are available for all SEP IV pump ends. Note:
Teflon® seals will reduce flow rates by 10%.The SEP IV standard
pump ends are available in eighteen standard models,
����� ����
Left: Bearings with sand channels. All PBT standard bearings are
water-lubricated and have a square shape enabling sand particles,
if any, to be flushed out of the pump together with the pumped
fluid.
Left: SEP IV Pump System. The pump (top half) is bolted to the
electric motor
(bottom half). The motor leads are not shown.
producing flow rates up to 75 gpm and to depths up to 400 feet.
Other pump ends are available.The SEP IV Pump System consist of
three components: the pump end, the pump motor and the motor lead.
Selecting the most efficient system for your site requires the
following information:
• total head• desired flow rate• well depth• well diameter•
chemical compatibility requirements
Use the pump curves to match your flow rate and total head to
select the pump end that best meets your requirements. The curve
will indicate the motor horsepower required. Se-lect the motor
leads for your well depth.
PUMP END SPECIFICATIONSRotational Speed 3450 rpm
Max. Quantity of Sand 0.25 lb/100 ft³ (40 g/m³)
Min. Recomm. Level of Suction 3.28 ft (1 m)
Maximum Liquid Temperature 86°F (30°C)
Maximum Starts per Hour 15 to 20
■ Electric Motor All motors are manufactured by Franklin
Electric and are available from 0.5 to 7.5 hp. The motors are
available in single phase 230 V, three phase 230 V or three phase
460 V. The three phase motors are used when the pump speed will be
variable. Other motors are available upon request.
Single Phase three-wire pump motors require the use of a control
box containing a starting capacitor and relay. The three-wire
motors provide a soft start and may offer better service life in
deep well or in conditions where the motor requires higher torque
to start. The two-wire motors use an internal bi-metal switch to
start the motor.
■ Motor Lead
Motor leads are supplied separate from the pump end and motor
assemblies. DGSI manufactures standard PVC leads in continuous
lengths with no splices and individually insu-lated. The motor lead
assembly can be supplied in Tefzel®, a material that combines
superior mechanical toughness with an outstanding chemical
inertness.
It is important to confirm chemical compatibility before
choosing your motor lead type.
Motor leads are 12-gauge wire with either two- or three-wire
leads plus the ground.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 17
SUBMERSIBLE PUMPSSEP IV
DURHAM GEO SLOPE INDICATOR
ORDERING INFORMATION FOR PUMP ENDS
Pump Model
Part Number StagesDimensions Weight
RequiredPower
Recommended Motor End(Part Number)
Length O.D. D
lb kg hp kWPBT Seals
(Std)Teflon® Seals in mm in mm NPT
5 gpm
TR-2400 TR-2400T 9 15.543 344
3.976 101
1¼
9.7 4.4 1/2 0.37
TR-2401 TR-2401T 12 16.850 428 11.4 5.2 1/2 0.37 TR-2335,
TR-2336 or TR-2338TR-2402 TR-2402T 15 20.984 533 14.1 6.4 3/4 0.56
TR-2505
10 gpm
TR-2403 TR-2403T 9 15.543 344 9.7 4.4 1/2 0.37 TR-2335, TR-2336
or TR-2338
TR-2404 TR-2404T 13 16.024 407 11.4 5.2 3/4 0.56 TR-2505TR-2405
TR-2405T 18 18.504 470 13.2 6 1 0.75 TR-2345, TR-2346 or
TR-2348
16 gpm
TR-2406 TR-2406T 5 10.236 260 6.6 3 1/2 0.37 TR-2335, TR-2336 or
TR-2338TR-2407 TR-2407T 8 12.716 323 8.8 4 3/4 0.56 TR-2505TR-2408
TR-2408T 10 14.370 365 11.0 5 1 0.75 TR-2345, TR-2346 or
TR-2348
25 gpm
TR-2409 TR-2409T 3 8.622 2191½
5.5 2.5 1/2 0.37 TR-2335, TR-2336 or TR-2338
TR-2410 TR-2410T 7 11.929 303 8.8 4 1 0.75 TR-2345, TR-2346 or
TR-2348TR-2411 TR-2411T 11 15.236 387 9.9 4.5 2 1.49 TR-2314
40 gpm
TR-2412 TR-2412T 5 16.102 409
2
13.2 6 1½ 1.12 TR-2350, TR-2351 or TR2352
TR-2413 TR-2413T 9 22.717 577 15.4 7 3 2.24 TR-2315TR-2414
TR-2414T 15 32.638 829 26.4 12 5 3.73 TR-2316
75 gpm
TR-2415 TR-2415T 5 14.961 380 16.5 7.5 3 2.24 TR-2315TR-2416
TR-2416T 8 20.079 510 23.5 10.7 5 3.73 TR-2316TR-2417 TR-2417T 12
37.992 965 29.0 13.2 7½ 5.59 TR-2317
ORDERING INFORMATION FOR MOTOR ENDSMOTOR END (230 V)
Part Number
PowerWires Phase Length(in)
Weight(lb)(hp) (V)
TR-2335
0.5
230
2 1
9.5 18.0TR-2336 3 1
TR-2338 3 3
TR-2505 0.75 2 1 10.7 21.0
TR-2345
1
2 1
11.8 24.0TR-2346 3 1
TR-2348 3 3
TR-2350
1.5
3 1
13.6 29.0TR-2351 2 1
TR-2352 3 3
TR-2314 2
3 3
13.6 28.0
TR-2315 3 20.6 44.0
TR-2316 5 23.5 50.0
TR-2317 7.5 18.0 66.0
Note: Three-phase 460 V motors are available.
ORDERING INFORMATION FOR MOTOR LEADSMOTOR LEAD (PVC Coated)
Length Type Part # Type Part #25 ft
2 Wire12 gauge
TR-137603
3 Wire12 gauge
TR-137609
50 ft TR-137604 TR-137610
75 ft TR-137605 TR-137393
100 ft TR-137606 TR-137394
150 ft TR-137607 TR-137395
200 ft TR-137608 TR-137396
250 ft TR-137611 TR-138398
300 ft TR-137612 TR-137397
MOTOR LEAD (TEFZEL©)Length Type Part # Type Part #
25 ft
2 Wire12 gauge
TR-38130
3 Wire12 gauge
TR-38106
50 ft TR-38131 TR-38102
100 ft TR-38132 TR-38103
150 ft TR-38133 TR-38104
200 ft TR-38134 TR-38105
300 ft TR-38135 TR-38107
Custom and high-flow pumps are available on request. Please call
to discuss your requirements.
SepTek Pump Control (optional)The SepTek mechanical down-well
controller is an ideal device to use with the SEP IV pumps to
maintain a desired level of water table draw down. See page 24 for
details.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
18
SEP IVDURHAM GEO SLOPE INDICATOR
0
20
40
60
80
100
120
140
160
180
[m]
0
[ft]
Head
100
200
300
400
500
600
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6Q [m³/h]
0 2 3 4 5 6 71
FLOW RATE
��� ��� ����� � �� �� ��
Model: 5 gpm
[US gpm]
TR-2401 (1/2 hp)
TR-2400 (1/2 hp)
TR-2402 (3/4 hp)
FLOW RANGE: 1.2 – 7 gpm
Performance Curves
Performance @ 2 ft min. submergence
Factory-assembled motors and motor leads.We make our own motor
leads to provide the specified full cable lengths with no splices.
We use potted plugs for greater life and reliability of the
connection. For every order, we test the motor leads and motors as
complete assem-blies, with a high-voltage megohmmeter, for quality
and compliance.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 19
SUBMERSIBLE PUMPSSEP IV
DURHAM GEO SLOPE INDICATOR
0
40
80
120
160
[m]
0
[ft]
-1
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2Q [m³/h]
Head
0 2 4 6 8 10 12 14
200
400
FLOW RATE
[US gpm]
TR-2404 (3/4 hp)
TR-2405 (1hp)
TR-2403 (1/2 hp)
Model: 10 gpmFLOW RANGE: 5 – 14 gpm
0
40
80
120
[m]
0
[ft]
-
400
200Hea
d
FLOW RATE
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4 Q [m³/h]
0 4 8 12 16 20 [US gpm]
TR-2408 (1 hp)
TR-2407 (3/4 hp)
TR-2406 (1/2 hp)
Model: 16 gpmFLOW RANGE: 10 – 20 gpm
0
40
80
120
[m]
0
[ft]
400
200
Hea
d
0.0 0.8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 7.2 Q [m³/h]
0 4 8 12 16 20 24 28 32
FLOW RATE
[US gpm]
TR-2409 (1/2 hp)
TR-2410 (1hp)
TR-2411 (2 hp)
Model: 25 gpmFLOW RANGE: 18 – 32 gpm
Performance @ 2 ft min. submergence
Performance @ 2 ft min. submergence
Performance @ 2 ft min. submergence
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
20
SEP IV DURHAM GEO SLOPE INDICATOR
0
40
80
120
160
[m]
0
[ft]600
400
200
Hea
d
0 1 2 3 4 5 6 7 8 9 10 11 12 Q [m³/h]
0 5 10 15 20 25 30 35 40 45 50 55
FLOW RATE
[US gpm]
TR-2413 (3 hp)
TR-2414 (5 hp)
TR-2412 (1.5 hp)
Model: 40 gpmFLOW RANGE: 24 – 55 gpm
0
10
20
30
40
50
60
70
80
90
100
110
120
[m]
0
[ft]
50
100
150
200
250
300
350
400
Hea
d
�
0 2 4 6 8 10 12 14 16 18 20 Q [m³/h]
FLOW RATE
0 20 40 60 80 100
22
[US gpm]
TR-2415 (3 hp)
TR-2416 (5 hp)
TR-2417 (7.5 hp)
Model: 75 gpmFLOW RANGE: 45 – 95 gpm
Performance @ 2 ft min. submergence
Performance @ 2 ft min. submergence
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 21
SUBMERSIBLE PUMPSSEP IVDURHAM GEO SLOPE INDICATOR
Fluid Level Control SystemsIncrease pump life by reducing the
number of motor starts and stops
Application and benefits❖ Maintain a precise drawdown level in a
well for
extended periods.
SEPTEK™ Precise drawdown without above-grade con-trollers
The SepTek is a mechanical down-well device used with electrical
pumps to maintain a desired water table draw-down for extended
periods.Installation is easy. Simply place the SepTek in line above
the SEP IV or other electric pump exactly where the de-sired water
level is to be maintained and walk away! The SeptTek/SEP IV Combo
will do the rest. No need for cycling submersible motors on and
off. No expensive relays, no VFD’S, no throttling valves. It’s
simple and maintenance is low. When the pump is activated, the
internal float will respond by directing the liquid to the surface
or recirculating it in the well to match the fluid output to the
recharge rate of the well which maintains the desired level. The
pump will operate continuously, increasing the motor life. The
SepTek system provides for full fluid discharge with no head loss
or restrictions. It is constructed of a PVC body, brass bypass
valve, cast bronze and stainless steel linkage.
ORDERING INFORMATION
TR-586 SepTek with 1-in Inlet and Discharge 22 lb
TR-586
(R) Typical assembly showing the SepTek (above) connected to an
SEP IV pump (bottom).
Internal workings
SEP IV Control PanelsElectrical level control system
DGSI can supply UL-approved control panels for your spe-cific
requirements. All of our panels meet or exceed NEMA standards.
The panels may be configured using variable speed drives
allowing the pump speed to match the recharge rate of the well.
Multiple pumps may be controlled by a single panel.
Simple ON/OFF control panels may be provided using float sensors
or pressure transducers to activate or deactivate the pump.
Please call for specific details.
Controller shown with optional SEP IV pump
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
22
Fluid Level ControlDURHAM GEO SLOPE INDICATOR
■ Three-phase PumpSavers
Three-phase PumpSavers combine a voltage relay, an underpower
relay and an electronic overload relay into one device to provide
optimal protection. The underload trip is based on power which is
desirable when the current vs. load characteristic in non-linear or
has little change—which is the case with these relatively small
motors.
PumpSaver®Submersible pump protector
PumpSavers are optional pump monitors designed to protect
single- or three-phase submersible electric pumps from dry wells,
dead head, jammed impellers, rapid cycling, over/under voltage,
and, depending on the model, other conditions. They protect 2- or
3-wire pumps from 1/3 hp to 3 hp.
■ Single-phase PumpSavers
Single-phase PumpSavers measure the power factor, volt-age and
current. These measurements are collected and analyzed by a
microcontroller which, under precise condi-tions, trips a built-in
relay to shut off the pump motor to prevent damage.
A calibration adjustment allows models TR-2601 and TR-2602 to be
calibrated to specific pumping applications, thereby reducing the
possibility of false or nuisance trip-ping. When an abnormality
(such as would occur in a loss of suction) in power fluctuations,
overcurrent, or undercur-rent is detected, The PumpSaver
deactivates its output re-lay and directly disconnects the pump
motor. The unit then begins its user-selectable re-start delay
(dry-well recovery) timer. When the timer counts to zero or power
is removed and reapplied, the PumpSaver reactivates its output
relay and turns the pump back on. An infrared LED can commu-nicated
directly with the Informer (sold separately).
The Informer is an optional diagnostic tool for use with TR-2601
and TR-2602. This hand-held device reads val-ues from the LED on
the PumpSaver and displays 15 pa-rameters including real-time
voltage, current, and power; dry-well and overload trip points;
calibration voltage; volt-age, current, power at last fault;
highest/lowest voltage and current since last calibration; model
number.Note: The use of restrictors or unusually high head
pressures at the time of calibration may interfere with the
detection of dead head conditions.
PumpSaver, TR- 2601
PumpSaver, TR-2604
Informer, TR- 2606
Typical wiring diagram for TR-2604
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 23
SUBMERSIBLE PUMPSFluid Level ControlDURHAM GEO SLOPE
INDICATOR
■ Motor Monitoring Device
The Remote Motor-Monitoring Device improves safety for service
and operations personnel by allowing them to con-trol and monitor
the PumpSaver (TR-2603, TR-2604, and TR-2604 only) without opening
the control panel. It requires a Communication Module on each
PumpSaver to enable the Modbus communications function. One Remote
Motor-Monitoring Device can monitor up to 16 PumpSavers
In addition to monitoring functions, the Motor-Monitoring Device
can reset a tripped PumpSaver.
The enclosure is NEMA 3R outdoor rated and is easily mounted on
the front of a panel. One device can control up to 16 PumpSaver
units through an RS-485 network using Modbus TRU protocol. A second
communication port allows monitoring and control from a computer,
PLC, or SCADA system.
The Motor-Monitoring Device displays:• Individual line currents
and average current• Current unbalance• Individual phase voltages
and average voltage• Voltage unbalance• Present fault trip reason
and restart timer status• Last four faults• PumpSaver setpoints•
Run-hours on each motor• Warning of pending (imminent) faults
The Motor-Monitoring Device controls:• Reset run-hour metre•
Reset PumpSaver• Clear last fault in PumpSaver• Change set point
for the Motor-Monitoring Device
PUMPSAVER® SELECTION TABLEPart Nr TR-
2601TR-
2602TR-
2603TR-
2604TR-
2605Load Range (hp) 1/3 - 1 1/3 - 1.5 1/3 - 3 1/3 - 3 3 -
7.5
Phase 1 1 3
Line Voltage [V (ac)] 115 230 95-240 190 - 480
Frequency 50*/60 Hz
Low Voltage ● ●High Voltage ● ●Contact Failure ●Linear Trip
Delay ●Low Kilowatt Trip Point ●Low Horsepower Trip Pt.
●Underload/Undercurrent ● ●UL Listed Overload ●Overload/Overcurrent
● ●Current Unbalance ●Rapid Cycling ● ●Diagnostic Display (3 digit)
●Diagnostic LEDs ●Manual Reset ● ●Informer Compatible
●Motor-Monitoring Device (sold separately)
●
* 50 Hz will increase all dealy timers by 20%.
ORDERING INFORMATIONTR-2601 PumpSaver® 1/3 - 1.0 hp
115 V (ac), single phase, *1.6 lb
TR-2602 PumpSaver® 1/3 to 1.5 hp230 V (ac), single phase,*
1.6 lb
TR-2603 PumpSaver®, 1 - 9 A 240 V (ac), single phase
2.0 lb
TR-2604 PumpSaver®, 1 - 9 A190 - 480 V (ac), three phase
2.0 lb
TR-2605 PumpSaver®, up to 7.5 hp190 - 480 V (ac), three
phase
2.0 lb
Options:TR-2606 INFORMER diagnostic tool for single-
phase PumpSavers. Batteries not included.
0.5 lb
TR-2607 Remote Motor-Monitoring Device (for TR-2603, TR-2604,
and TR-2604). Requires communications module, TR-2608
0.5 lb
TR-2608 Communications Module (for TR-2607 ) — * in NEMA 3R case
with lens.
Communications Module, TR- 2608
Motor-Monitoring Device, TR- 2607
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SUBMERSIBLE PUMPS
24
Fluid Level ControlDURHAM GEO SLOPE INDICATOR
Pump CentralizersPrevent pump hang-ups and improve cooling.
The upper and lower centralizers are mounted at both pump
extremities to guide the assembly past internal pipe irregularities
such as those encoun-tered on butt-fused PVC pipe. The centralizers
improve laminar flow around the pump and allow the motor to operate
at a cooler temperature.
In addition to the centralizers, the set includes a nipple, a
coupling with cable hook, and connecting rods.
For 6-in dia. and larger wells.
SPECIFICATIONS
Dimensions 5” diameter x 4.25” longMaterials Centralizers:
HMW
Connecting rods: 304 stainless steel and HDPECoupling and
nipple: 304 stainless steel.
ORDERING INFORMATION
TR-2495 Pump Centralizer Set 3 lb
Orifice for lead wires
Electric Pump
Upper Centralizer
Lower Centralizer
Water Level Monitoring
■ Titanium Pressure Transducers
Designed for compatibility with industrial data loggers, the
titanium pressure trans-ducer is used to monitor pore-water
pressure and water levels. Typical ap-plications include
monitor-ing water levels in pumping tests or pore-water pressures
in corrosive environments such as salt water and landfills. The
titanium pressure transducer can be read continuously.All metal
parts, including the diaphragm, are made from titanium for high
resistance to corrosion.See page 36 for vented pressure transducers
to monitor water level in wells and standpipes, and stilling basins
installed in reservoirs and streams.
SPECIFICATIONS
Dimensions 0.625” diameter x 5.75” longSensor Type Diaphram
pressure transducer with Micron
Technology semi-conductor strain gauges with a 4-20mA output.
The built-in temper-ature device is a 3K ohm thermistor.
Resolution 0.02% FS with a Campbell R10X and a 120 ohm
resistor.
Linearity ± 0.5 % FS BFSLCompensated Temp Range
30 to 130°F
Over-Range 2 x rated rangeLong Term Stability ± 2% FS/year or
betterSupply Voltage 12-24 V nominal supply, 8 V min at the
transducer.Materials Wetted metal parts are made from tita-
nium. The filter is polyethylene.
■ Signal CableShielded cable with four 22-gauge tinned-copper
conductors and polyurethane jacket. Two wires are used for the
4-20mA loop circuit. The other two wires are used for the
thermistor.
■ ReadoutsDataMate MP. See separate datasheet.Also: Industrial
data loggers and readouts capable of supplying 12-24 volts to the
transducer.
ORDERING INFORMATION
56410020 Electro-Piezo, 4-20mA 20 PSI 1 lb56410050
Electro-Piezo, 4-20mA 50 PSI 1 lb56410100 Electro-Piezo, 4-20mA 100
PSI 1 lb56410250 Electro-Piezo, 4-20mA 250 PSI 1 lb50613524 Signal
cable, 4-22g PU Alum Shld (sold per ft)
SEP IV pump assembly with optional pump c entralizer set
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 25
DURHAM GEO SLOPE INDICATOR
DGSI supplies an extensive range of tubing and hose for use with
our remediation, ground water sampling and well devel-opment pumps.
Tubing and hose are used for the fluid discharge and air supply
lines. It is very important to insure chemi-cal compatibility with
the fluids that will be pumped. When distinguishing between tubing
and hose, it is important to note the following: When selecting
tubing or hose, it is important to accommodate for the friction
losses that will occur based on the lengths being used.
Tech Tip: Tubing is measured by the O.D.; Hose is measured by
the I.
SELECTION TABLE FOR TUBING, HOSE AND SUSPENSION CABLEPart Nr.
Description Used With Following Pumps Application Max.. Pressure
TUBINGTR-737 1/2 in ID X 5/8 in OD Polyethylene Tubing D-16/SS16,
D-25 Inertia Air Supply
200 psi
TR-736 3/8 in ID X 1/2 in OD Polyethylene Tubing Arch PumpD-13
Inertia
Air SupplyFluid Discharge
TR-735 0.17 in ID x 1/4 in OD Polyethylene Tubing F.A.P. Plus™,
MVP, Evacuator Logic
Down Well Air Supply
601614 1/8” O.D. x .095 I.D. Nylon® 1/2 in. Mini Bladder Air
Supply
601615 3/16” x .125 I.D. Teflon® 1/2 in. Mini Bladder
Discharge
TR-031 0.17 in ID x 1/4 in OD Teflon®-lined Poly Tubing Mini
Bladder (> 1/2 in) Fluid Discharge
TR-033 0.17 in ID x 1/4 in OD Teflon®-lined Poly Tubing x 1/4 in
OD Poly Bonded
Mini Bladder (> 1/2 in) Air SupplyFluid Discharge
TR-034 1/4 in Poly x 3/8 in Teflon®-Lined Bonded Tubing Mini
Bladder Air SupplyFluid Discharge
TR-023 3/8” OD Teflon®-lined Poly Tubing Mini Bladder Drop
Tube
TR-025 0.17 in ID x 1/4 in OD Dual Bonded Poly Tubing Mini
Bladder Air Supply, Fluid Discharge
TR-030 3/8 in ID x 1/2 in OD Teflon®-lined Poly Bonded to 0.17
in ID x 1/4 in OD Poly Tubing
Standard Bladder Air Supply, Fluid Discharge
TR-0300 3/8 in ID x 1/2 OD Teflon®-lined Poly Tubing Standard
Bladder Discharge
HOSETR-743 1 in ID Buna-N® Hose MVP Fluid Discharge 300 psi
TR-733 3/4 in ID Buna-N® Hose MVP Fluid Discharge 250 psi
TR-734 3/8 in ID Buna-N® Hose F.A.P. Plus™MVP
Fluid Discharge and/or Air Supply; Air Exhaust
250 psi
TR-732 1/2 in ID Buna-N® Hose F.A.P. Plus™ Fluid Discharge
and/or Air Supply
200 psi
TR-38901 1/2 in ID x 3/4 in OD PVC Hose Sample Plus™ Fluid
Discharge and/orAir Supply
200 psi
TR-390 1/2 in ID x 5/8 in OD Teflon®-lined Hose with Tefzel
Power Cable (all encased in PVC sleeve)
Sample Plus™ Fluid Discharge and Power Cable
200 psi
TR-389 1/2 in ID x 5/8 in OD PVC Hose with Tefzel® Power Cable
(all encased in PVC sleeve)
Sample Plus™ Fluid Discharge and Power Cable
200 psi
TR-777 (1) 3/4 in ID, (1) 3/8 in ID Buna-N® Hoses with 1/4 in OD
Nylon Tubing
MVP Down Well Hose As-sembly
250 psi
TR-731 (1) 5/8 in OD Nylon®, (1) 1/2 in OD Nylon®, (3) 1/8 in OD
Nylon® Hoses (all encased in PVC sleeve)
Evacuator II Down Well Hose As-sembly
250 psi
SUSPENSION CABLE918702 Nylon®-Covered Stainless Steel Stranded
Cable Safety Suspension Cable for Pumps in Down Well
Applications
TUBING, HOSE AND CABLE
Download datasheets, manuals, and technical notes from
www.durhamgeo.com
TUBING, HOSE, CABLE
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
SOLAR-POWERED REMEDIATION
26
SolarNAPLDURHAM GEO SLOPE INDICATOR
SolarRem™ is a registered trademark of the SolarRem
Corporation
SolarRem™ Solar-Powered Remediation System
ApplicationThe SolarRem system can be configured for the
fol-lowing applications:❖ LNAPL recovery❖ DNAPL recovery
❖ Gas condensate recovery
❖ Groundwater pumping❖ Air sparging
Description ■ NEMA 4 control panel with PLC ■ 7.5 gallon
receiver tank ■ One 100 W solar panel ■ 105 Ah AGM battery ■ Tank
full shut-off SolarRem™ is a patented solar-powered air compressor
which can be configured to run various pneumatic pumps or used for
air sparging. These pump as-semblies are optional. Because it uses
the sun’s energy — a renewable resource — as the only power source
necessary to operate recovery pumps, the SolarRem™ system is
particu-larly friendly to the environment.
Installation Advantage
SolarRem™ systems are pre-designed, compact, easy to install and
operate. They can be installed and operated at remote sites quickly
without the need for an exter-nal power source. This minimizes
construction costs and saves time and coordination efforts while
avoiding costly delays. These advantages are particularly
meaningful dur-ing installation on tank farms where costly
trenching and the process of identifying underground lines are
avoided.
SolarNAPL System (TR-51600)
The SolarNAPL System is configured to provide an air source to
power the optional F.A.P. Plus™ pump skimming system for product
recovery. The system uses a solar panel to charge the special AGM
deep cycle battery specially de-signed for use in solar
applications. The battery powers the internal DC compressor. The
control panel includes a PLC allowing the operator to set system
On/Off times consistent with the air requirements of the pump. The
On/Off times are user defined and based on the amount of product to
re-cover, the well’s recovery rate, and the F.A.P. Plus’ pumping
rate of approximately 0.18 gpm.
The standard SolarNAPL will recover between 15 to 25 gal-lons of
product per day depending on its location. Systems are designed
based on hours of sunlight. Additional solar panels and batteries
may be required to achieve optimum performance for your specific
site. Contact Durham Geo Slope Indicator for recommendations on
solar panels and battery ampere-hour capabilities for your
site.
Tech Tip: The SolarNAPL control panel is not rated for use in XP
areas. For application such as inside tank farm berms, the units
can be pole mounted above the XP area.
The standard SolarNAPL System includes the NEMA 4 control panel,
a 7.5 gallon air receiver tank, one 100 W solar panel, a 105 A•h
Advanced Glass Matte (AGM) battery and the Tank Full shut-off. The
Tank Full shut-off turns the air supply to the pumping system off
when the prod-uct tank is full. The F.A.P. Plus™ Pump (TR-516),
skimmer (TR-517), solar panel mounting pole (TR-51613) and the
bracket (TR-51615) must be purchased separately.
Tech Tip: The SolarNAPL System can be configured to operate
multiple F.A.P. Plus™ Skimming Pumps and can be trailer mounted for
greater on-site mobility.
SolarNAPL, TR-51600, in field application. Recovery drum and
accessories not included.
Download data sheets, manuals and technical notes from
www.SolarRem.com
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 27
SOLAR-POWERED REMEDIATIONDURHAM GEO SLOPE
INDICATORSolarSparge
SPECIFICATIONS for SolarRem™ SolarNAPL Compressor Pump Type
Piston Pump
Max.. Rated Pressure 100 psi
Operating Flow Rate 0.79 scfm at 0 psi 0.24 scfm at 100 psi
Oper. Pressure Range 25 - 100 psi
Hysteresis (Dead Band) 20%
Air Connection Line PushLock© fittings.
Housing Type NEMA 4 metal box
Air Receiver Tank Capacity 7.5 gal
Battery CapacityType
105 A•hAdvanced Glass Matte (AGM)
Solar Panel Capacity 110-120 W
Dimensions (W x H x D)
Compressor Assembly 28 x 36 x 15 in
Solar Panel 59 x 29 x 2 in
Battery w/ case 14.5 x 17 x 14 in
Weight Total 210 lb
Compressor Assembly 105 lb
Solar Panel 30 lb
Battery w/ case 75 lb
Ship. Volume 9 ft³
ORDERING INFORMATIONTR-51600 SolarNAPL Control System. 210
lb
Supplemental Items (if required):TR-51610 Solar Panel, 100
Watt
TR-51611 Solar System Battery, 12 V, 105 Ah, AGM type
TR-51612 Solar System Battery, 12 V, 200 Ah, AGM type
TR-51613 Solar Panel Mounting Pole, Single
TR-51615 Solar Panel Bracket
Options:TR-51660 Dual axle trailer
Related Items:TR-516 F.A.P. Plus™ Pump
TR-517 F.A.P. Plus™ 36" Travel Skimmer
TR-70410 4” High Viscosity Density Rod Skimmer (30” travel)
SolarNAPL, custom mounted on dual axle trailer (TR-51660).
SolarSPARGE System (TR-51680)
This system can also be configured with a high flow, low
pressure air compressor for air sparging applications. The standard
SolarSPARGE system will produce 0.79 cfm at 25 psi. In a typical
application, the system will produce 160 ft³/day of air flow for a
20 ft water column (20 psi). The solar panel and batteries will be
sized according to your location and air flow requirements. At a
minimum, we use the 100 W solar panel and 105 A•h battery. The 1/6
hp air compressor produces 0.20 cfm at 20 psi. The NEMA 4 control
panel allows to select air flow and times.
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
LOW FLOW SAMPLING
28
DURHAM GEO SLOPE INDICATORMini Bladder Pumps
pump. The annular space is pressurized using the control-ler and
the liquid is gently lifted to surface. All pumps can be supplied
contaminant free.
Tech Tip: In portable applications, the pump is easily
decontaminated by submersing it in a clean-ing solution such as
Alconox®. Then the pump is cycled to circulate the solution through
the internal components. This method avoids the need to
replace bladders after each use. Dedicated assemblies can be
supplied to reduce cross contamination, well dis-turbance and
facilitate installation. The pump, tubing and well cap assemblies
are plastic bagged and each assembly is identified with your well
ID number and the well depth.
Mini Bladder Pumps (MBP)Specifically Designed for Low Flow
Sampling
Application
❖ Low-flow ground water purging and sampling❖ 1/2 in and
larger-diameter schedule 40 wells
Description
The MBP pumps consist of: ■ PVC or SS outer body ■ Teflon
bladder ■ ½, ¾, 1, 1.3 and 1.66 in dia.
The pneumatic Mini Bladder Pumps are designed to obtain a
representative ground water sample with the assistance of a
controller to provide variable flow rates. The controller allows
the user to match the pumping rate to the well recharge rate,
limiting the stress on the formation. With the small volume per
cycle, the fluid velocity at the pump inlet is substantially
reduced, making the pumps ideal for low flow sampling. The high
efficiency design enables pump rates from 5 mL to nearly 2 L/min
when used with one of our Precision Dual Range Controllers. The
1.66 in diameter pump will produce flow rates up to 2 gpm.
Tech Tip: The amount of pump submergence will affect the pump
flow rate. Pump curves were de-veloped with 10 ft submergence.
The bottom inlet of the pump is positioned at the desired
sampling point, generally at the mid sec-tion of the well screen.
The inner Teflon® bladder will fill with fluid based on the
submergence of the
LOW FLOW SAMPLING
Selection Table Flow Rates on Page 34 * Depths over 250 ft
require the use of a drop tube (TR-041)Type Stainless Steel PVC
Reference Diameter 1/2 in 3/4 in 1 in 11.3 in 1.66 in
Body Length (nom.) 118 in 18 in 18 in 1414 in 20 in
Stroke Volume 20 mℓ 51 mℓ 95 mℓ 135 mℓn 175 mℓn
Max.. Lift 100 ft 150 ft 150 ft 150 ft 200 ft*
Tubing Size 1/4 x 1/4 in 1/4 x 1/4 in 1/4 x 1/4 in 1/4 x 1/4 in
1/4 x 3/8 in
Weight 12 oz 12 oz 18 oz 14 oz 2 lb
Materials Body: 304 Stainless Steel. Bladder: flexible Teflon®
Body: PVC. Bladder: Teflon®
Part Number TR-042 TR-037 TR-035 TR-070 TR-071
Models for wells down to ½ in and depths to 400 ft. Stainless
Steel or PVC.
Contaminant-Free CertificationUpon request, ground water
sampling pumps may be supplied as certified to be contaminant free.
The rinse water from the equipment is analyzed by one or all of the
following methods by an independent and accredited laboratory.
EPA Method 624 (Purgeable Aromatics)EPA Method 625 (Base/Neutral
Extractables)
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557 29
LOW FLOW SAMPLINGDURHAM GEO SLOPE INDICATORSample Plus™
Precision Dual Range Controllers
Precision Dual Range Controllers allow precise control of the
cycle time and the air pressure sup-plied to the bladder pump. This
degree of control makes it easy to obtain a repeatable sample. Two
independent air pressure regulators with gauges are provided to
allow pre-cise control of the applied
pressure in ranges of 2-50 psig and 5-100 psig. The
encapsu-lated timer module provides accurate, independent timing of
the pressure and exhaust cycles from 0.1 to 10 seconds.The standard
controller has no compressor and requires an external air source.
Alternatively and for convenience, we offer a compressor/controller
with a built-in, DC powered compres-sor. This unit is designed for
use in wells with depths of 50 ft or less. An external air source
can be used for deeper applica-tions.Both Controllers are powered
by an internal lead acid gel cell battery. The standard controller
(without compressor) will oper-ate continuously for approximately
2-3 days. The controller with built-in compressor will operate
continuously for approximately 1½ hours on a fully charged battery.
The use of an external 12 V marine battery is recommended for
longer operating peri-ods. Includes 110 V (ac) charger and 12 V
auto adapter.
ORDERING INFORMATIONTR-032 Precision Dual Range
ControllerTR-03210 Precision Dual Range Controller w/ Built-in
Compressor
Sample Plus™ DC Pump Systems
Application
❖ Low-flow purging and ground water sampling❖ 2 in and
larger-diameter schedule 40 wells
Description
■ Variable speed electrical submersible pump ■ DC up to 125 ft
depths ■ AC for 250 ft depths ■ Stainless steel and Teflon®
construction ■ Tefzel® round motor cable
The Sample Plus™ Pumps are used with a power inverter (which
must be purchased separately) to provide variable flow rates from 5
mL up to 5 gpm. The inverter is shown above with an additional
Six-Stage pump. The pump produces a laminar flow making it ideal
for low flow sampling. The six stage pump can be powered by a
battery or 115 V AC power. The single stage AC pump uses 115 V and
requires a 1200 W (minimum) generator. The Sample Plus Pump is
constructed of chemi-cally inert stainless steel and virgin
Teflon®. It is specifically designed for use in wells relatively
free of silts and sands and should not be used for well
development. Pump main-tenance is simple. The Sample Plus™ is
designed for the replacement of individual components rather then
purchas-ing a complete new pump. The inverter’s digital display of
the speed makes it easier to produce repeatable flow rates.
Tech Tip: For decontamination, the pump end can be unthreaded to
access the impeller system or Alconox can be circulated through the
pump.
SIX-STAGE PUMP SINGLE-STAGE PUMPMin Well Dia. 2 in 2 in
Max.. Depth 125 ft 250 ft
Flow Rate 75 ml up to 2.2 gpm 100 ml to 5.5 gpmPower
Inverter
12 V DC or 115 V single phase AC power. Feature allows the pump
to operate from a battery or a small portable generator capable of
producing 290 watts.
115 V or 230 V Sample Plus™ Single Stage Pump Inverter. Requires
1250 W generator .
These pumps may be incorporated on the Real Plus™ System. The
power inverters must be ordered separately.
TR-03210 Compressor/Controller
Tubing, Cable For a comprehensive selection table, see page
19.
ORDERING INFORMATIONTR-033 1/4 in Teflon-Lined Poly x 1/4 in
Poly Bonded TubingTR-034 1/4 in Poly x 3/8 in Teflon®-Lined Bonded
TubingTR-030 Poly Tubing, 1/4 in Bonded to 1/2 in Teflon®
LinedTR-025 1/4 in Poly x 1/4 in Poly Bonded TubingTR-031 1/4 in
Teflon-Lined Polyethylene TubingTR-023 3/8 in Teflon-Lined
Polyethylene TubingTR-027 2 in Well Head Ass'y for Bladder
PumpsTR-028 4 in Well Head Ass'y for Bladder PumpsTR-029 6 in Well
Head Ass'y for Bladder Pumps918702 Nylon®-Coated Stainless Steel
CableTR-038 Freeze Protection Kit for Mini Bladder PumpTR-041 Drop
Tube Kit
-
www.durhamgeo.com ❖ [email protected] ❖ Tel:
1-800-837-0864 ● 770-465-7557
GROUND WATER PURGING
30
Peristaltic Sampling PumpIdeal for sampling and purging to 25
ft
Application
❖ Ground water purging and sampling to 25 ft❖ Sampling
direct-push wells❖ Sampling streams, ponds, lakes
❖ Sampling tanks and drums, manholes, culverts❖ Sampling waste
water
The TR-200 Peristaltic Sampling Pump is a lightweight,
compact, battery powered pump providing a fast, dependable and
economical means of sampling fluids in the field. Model TR-200 is
self contained and does not require an external controller.
The high-precision digital control and display provides precise
flow control and reference settings when purging or sampling —
which is important for repeatability. Warning lamps show battery
condition. Variable flows from 0 to 500 m