Top Banner
FEATURES  AP PL IC ATIONS Fuller Road - Industrial Estate Harleston - Norfolk - IP20 9EA Tel. 01379 853666 Fax. 01379 854414 E-Mail. [email protected]  Web. www.jenel ec.com INDUSTRIAL POWER SOLUTIONS DS-381/6 UniCharge 50 Automatic Battery Charger  COST EFFECTIVE HIGH RELIABILITY FULLY AUTOMATIC OPERATION 100% CONTINUOUS OPERATION COMPACT SIZE SOFT-STAR T CIRCUI T , LIMI TING AC SURGE CURRENT SHORT CIRCUIT PROTECTED OVERLOAD PROTECTED OVER VOLTAGE PROTECTED REVERSE BATTERY PROTECTED OVER TEMP. PROTECTED WORLDWIDE AC INPUT RANGE LOW RIPPLE OUTPUT SEALED ELECTRONIC CONSTRUCTION NATURALL Y COOLED  A VA ILABLE WITH 12 OR 24 VOL T NOMIN AL OUTPUTS OPTIONAL CHARGER FAIL ALARM & LED UL CERTIFIED - UL1236 7 th Ed. BBGQ2 cUL CERTIFIED - UL1236 7 th Ed. BBGQ8 STANDBY GENERATORS  AUTOMOTIVE  ALARM SYSTE MS MARINE INDUSTRIAL CONTROL SYSTEMS ROBUST PSU ELECTRIC VEHICLES UniCharge 50  Automatic battery charg ers provide a cost ef fective solution to most industrial battery charging requirements. Utilising the latest high efciency switch-mode technology the UniCharge 50 is suitable for continuous oat charging of sealed or vented batteries, for example sealed lead acid VRLA / AGM, Gel, ooded lead acid, Ni-Cad etc. The two stage constant current - constant voltage characteristic ensures accurate and efcient battery charging and is designed for permanent connection to the batteries maintaining them in a fully charged condition without overcharging. UniCharge 50 is fully protected against overload, reverse battery connection, over voltage and over temperature as standard.  Input Specication Voltage Range, V IN 85 - 264V AC Frequency 47 - 63Hz Input Current 1.5A@1 15V 0.75A@230V Inrush Current 30A @ 115V 60A @ 230V (Cold Start) Leakage Current <1.0mA @ 240V AC  Output Specication Voltage / Current 12V Types: 13.6V / 4.0A pk. (3.5A continu ous) 24V Types: 27.2V / 2.5A pk. (2.0A continu ous)  Other Voltages Available on Request Ripple & Noise <0.5% Line Regulation ±1% Load Regulation ±1% Efciency 77% - 80% Overload Protection Constant Current Limit Over Voltage Protecti on 115% - 135% Shutdown Over T emp. Protecti on Tj 135 O C - Shutdown Reversed Battery Internal diode with external 'automotive type' mini- Protection blade fuse. Setup, Rise, Hold Up 800ms, 60ms, 50ms (at 230V AC) Isolation Withstand Voltage Input – Output 1.5kV AC Input – Earth 1.5kV AC Output – Earth 500V DC Isolation Resistance 500V DC / 100M Ohms (Output-Earth)
3

DS-381_6 UniCharge 50

Apr 03, 2018

Download

Documents

Sajjad Hussain
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: DS-381_6 UniCharge 50

7/28/2019 DS-381_6 UniCharge 50

http://slidepdf.com/reader/full/ds-3816-unicharge-50 1/2

FEATURES 

 APPLICATIONS 

Fuller Road - Industrial Estate

Harleston - Norfolk - IP20 9EA 

Tel. 01379 853666

Fax. 01379 854414

E-Mail. [email protected] 

 Web. www.jenelec.com

INDUSTRIAL POWER SOLUTIONS

DS-381/6

UniCharge 50Automatic Battery Charger 

COST EFFECTIVE

HIGH RELIABILITY

FULLY AUTOMATIC OPERATION

100% CONTINUOUS OPERATION

COMPACT SIZE

SOFT-START CIRCUIT, LIMITING ACSURGE CURRENT

SHORT CIRCUIT PROTECTED

OVERLOAD PROTECTED

OVER VOLTAGE PROTECTED

REVERSE BATTERY PROTECTED

OVER TEMP. PROTECTED

WORLDWIDE AC INPUT RANGE

LOW RIPPLE OUTPUT

SEALED ELECTRONIC CONSTRUCTION

NATURALLY COOLED

 AVAILABLE WITH 12 OR 24 VOLT NOMINAL

OUTPUTS

OPTIONAL CHARGER FAIL ALARM & LED

UL CERTIFIED - UL1236 7th Ed. BBGQ2

cUL CERTIFIED - UL1236 7th Ed. BBGQ8

STANDBY GENERATORS

 AUTOMOTIVE

 ALARM SYSTEMS

MARINE

INDUSTRIAL CONTROL SYSTEMS

ROBUST PSU

ELECTRIC VEHICLES

UniCharge 50  Automatic battery chargers provide a cost effective

solution to most industrial battery charging requirements. Utilising thelatest high efficiency switch-mode technology the UniCharge 50 is suitable for 

continuous float charging of sealed or vented batteries, for example sealed lead

acid VRLA / AGM, Gel, flooded lead acid, Ni-Cad etc. The two stage constant

current - constant voltage characteristic ensures accurate and efficient battery

charging and is designed for permanent connection to the batteries maintainingthem in a fully charged condition without overcharging.

UniCharge 50 is fully protected against overload, reverse battery connection,

over voltage and over temperature as standard.

 Input Specification

Voltage Range, VIN

85 - 264V AC

Frequency 47 - 63Hz

Input Current 1.5A@115V 0.75A@230V

Inrush Current 30A @ 115V 60A @ 230V (Cold Start)

Leakage Current <1.0mA @ 240V AC

 Output Specification

Voltage / Current 12V Types: 13.6V / 4.0A pk. (3.5A continuous)

24V Types: 27.2V / 2.5A pk. (2.0A continuous)

  Other Voltages Available on Request 

Ripple & Noise <0.5%

Line Regulation ±1%

Load Regulation ±1%

Efficiency 77% - 80%

Overload Protection Constant Current Limit

Over Voltage Protection 115% - 135% Shutdown

Over Temp. Protection Tj 135OC - Shutdown

Reversed Battery Internal diode with external 'automotive type' mini-

Protection blade fuse.

Setup, Rise, Hold Up 800ms, 60ms, 50ms (at 230V AC)

Isolation

Withstand Voltage Input – Output 1.5kV AC Input – Earth 1.5kV AC

Output – Earth 500V DC

Isolation Resistance 500V DC / 100M Ohms (Output-Earth)

Page 2: DS-381_6 UniCharge 50

7/28/2019 DS-381_6 UniCharge 50

http://slidepdf.com/reader/full/ds-3816-unicharge-50 2/2Jenelec reserves the right to make changes in product specification without notice or liability. All data is considered accurate at time of going to print.

Finish

Black ABS plastic case - Fine Spark Erode

Termination

  AC input and DC output connections terminate

to rising clamp screw terminals and will accept amaximum 4.0mm2 stranded cable.

Optional alarm connections terminate to a 2-part

plug / socket connector and will accept a maximum

2.5mm2

stranded cable.

Charger Fail (Optional)

1 set of volt-free form C contacts for charger failsignalling. The contacts will de-energise if the

charger's input or output fails, the output fuse

blows or the battery polarity is incorrect.

A green "O/P OK" LED is also fitted for visual

status of the charger's output.

Environmental Specification

Working Temperature -10ºC to +50ºC

Working Humidity 20% - 90% RH

Storage Temperature -20ºC - +80ºC

Storage Humidity 10% - 95% RH

Unpacked Weight 1 Kg.

Ordering Information

Rating Part No. Charger Fail Alarm

12V Nominal (13.6V float) 4.0A pk JE/UC50-12-FD No

12V Nominal (13.6V float) 4.0A pk JE/UC50-12-FDC Yes24V Nominal (27.2V float) 2.5A pk JE/UC50-24-FD No

24V Nominal (27.2V float) 2.5A pk JE/UC50-24-FDC Yes

Note: Standard output voltages shown. For other output voltages and 

customised products please contact us.

General Arrangement External Connection