Top Banner
Principle of operation Configuration Air entry Capacity www.BaltimoreAircoil.eu Maximum entering fluid temperature Dry and adiabatic cooling products Operational safety (hygiene) Low sound Energy efficiency Easy maintenance Water saving Best G A counterflow axial fan induced draft DFCV-AD cooler 220 - 1620 kW 60°C C A A D B counterflow axial fan induced draft DCV-AD condenser 340 - 1030 kW / C A A D B counterflow axial fan induced draft SP cooler 340 - 1560 kW 60°C C A A D B counterflow axial fan induced draft DFCV cooler 220 - 1500 kW 60°C D D A A A counterflow axial fan induced draft 250 - 2000 kW 60°C A A B D E TVFC cooler Tab v06 EN © 2018 Baltimore Aircoil International nv
2

Dry and adiabatic cooling products - BAC Europe...Dry and adiabatic cooling products Dry and adiabatic cooling products Tab_DAC_ENv06 Dry or air cooled products Dry or air-cooled products

Jul 06, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Dry and adiabatic cooling products - BAC Europe...Dry and adiabatic cooling products Dry and adiabatic cooling products Tab_DAC_ENv06 Dry or air cooled products Dry or air-cooled products

Principle ofoperation

Configuration

Air entry

Capacity

www.BaltimoreAircoil.eu

Maximum entering fluid temperature

Dry and adiabatic cooling products

Operational safety (hygiene)

Low sound

Energy efficiency

Easy maintenance

Water saving

BestG A

counterflow

axial fan induced draft

DFCV-AD cooler

220 - 1620 kW

60°C

C

A

A

D

B

counterflow

axial fan induced draft

DCV-AD condenser

340 - 1030 kW

/

C

A

A

D

B

counterflow

axial fan induced draft

SP cooler

340 - 1560 kW

60°C

C

A

A

D

B

counterflow

axial fan induced draft

DFCV cooler

220 - 1500 kW

60°C

D

D

A

A

A

counterflow

axial fan induced draft

250 - 2000 kW

60°C

A

A

B

D

E

TVFC cooler

Tab v

06 E

N ©

2018

Balt

imor

e Airc

oil In

terna

tiona

l nv

Page 2: Dry and adiabatic cooling products - BAC Europe...Dry and adiabatic cooling products Dry and adiabatic cooling products Tab_DAC_ENv06 Dry or air cooled products Dry or air-cooled products

Dry and adiabatic cooling productsDr

y an

d ad

iaba

tic co

olin

g pr

oduc

ts

Tab_DAC_ENv06

Dry or air cooled products Dry or air-cooled products cool liquids or condensate gases in closed circuits via sensible heat transfer from high-density finned coil to air at ambient dry bulb temperature.

Key benefits• Eliminates water treatment and reduces water usage • Eliminates plumes • Reduced maintenance • Eliminates Legionella risks

Why go for evaporative rather than dry cooling?• When you need a fluid outlet temperature close to the design ambient dry bulb temperature • To save on energy costs • If the cooling unit plan area is compact or restricted

Adiabatic products Adiabatic products are air-cooled coolers or condensers with adiabatic pre-coolers. Before the fan draws the ambient air through the finned coil, the air is pre-cooled adiabatically when traversing an humidification pad. This evaporates the water in the air, thus boosting the cooling capacity.

Key benefits• low process temperatures • saves more than 80% on annual water compared to cooling towers • up to 40% increased capacity compared to dry cooling (air temperatures approaching wet bulb

temperature) • reduced energy consumption • operational safety: no water recirculation, no stagnant water, no aerosol generation, no water carry-over