Top Banner
Definite purpose contactors
6

Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

Apr 02, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

Definitepurposecontactors

Page 2: Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

Motor Locked Rotor Resistive Maximum Horsepower Incorporated Type of Catalog Number Full Load Load Auxiliary termination Amps (FLA) 1 Phase 3 Phase Contacts 600V 240V 480V 600V 600V 120V 240V 200V 240V 480V 600V (SPST) [A] [A] [A] [A] [A] [HP] [HP] [HP] [HP] [HP] [HP] NO NC THREE POWER POLES. 14 84 84 84 20 3/4 2 3 3 10 10 0 1 Clamp-screw DPBG12 01 A�

1 0 DPBG12 10 A�

20 120 120 100 30 11/2 3 5 5 10 10 0 1 Clamp-screw DPBF09 01 A�

1 0 DPBF09 10 A�

25 150 150 125 30 2 3 5 5 10 15 0 1 Clamp-screw DPBF12 01 A�

1 0 DPBF12 10 A�

30 180 180 150 32 2 5 71/2 71/2 15 20 0 1 Clamp-screw DPBF18 01 A�

1 0 DPBF18 10 A�

40 240 240 200 50 3 71/2 10 10 30 30 0 0 Clamp-screw DPBF26 00 A�

50 300 300 250 55 3 10 15 15 30 40 0 0 Clamp-screw DPBF32 00 A�

70 420 420 420 90 5 15 20 25 50 50 0 0 Double lug-clamp DPBF50 00 A�

80 480 480 480 115 71/2 15 25 30 60 60 0 0 Double lug-clamp DPBF80 00 A�

FOUR POWER POLES �. 14 84 84 84 20 3/4 2 3 3 10 10 0 0 Clamp-screw DPBG12 T4 A�

20 120 120 100 30 11/2 3 5 5 10 10 0 0 Clamp-screw DPBF09 T4 A�

25 150 150 125 30 2 3 5 5 10 15 0 0 Clamp-screw DPBF12 T4 A�

30 180 180 150 32 2 5 71/2 71/2 15 20 0 0 Clamp-screw DPBF18 T4 A�

40 240 240 200 50 3 71/2 10 10 30 30 0 0 Clamp-screw DPBF26 T4 A�

70 420 420 420 90 5 15 20 25 50 50 0 0 Double lug-clamp DPBF50 T4 A�

80 480 480 480 115 71/2 15 25 30 60 60 0 0 Double lug-clamp DPBF80 T4 A�

DPBF26ADPBF32A

DPBF09 - DPBF12 - DPBF18 -DPBF09 T4 - DPBF12 T4 - DPBF18 T4

DPBF50DPBF80

DPBG12 DPBF50 T4DPBF80 T4

� Complete catalog number with coil code in theside table.

� The DPBF26...80 3-pole types can be retrofittedwith fourth pole, catalog number BFX42 or BFX43.See page 2.

General characteristicsIdeal for air conditioning, heating, ventilation, refrigerationof HVACR industry, compressors, food and beverageindustry. Main features:– Motor FLA ratings at 600VAC: 14 to 80A – Finger safe terminals– Positive (force) guided contacts– Up to four front or side mount auxiliary contacts– Highly conductive auxiliary contacts – Quick and simple installation for accessories– Easy coil replacement– Wide coil operating range.Operating characteristics– Average coil consumption at 20°C/70°F:

In rush Holding • DPBG12 25VA 4VA• DPBF09-32 75VA 9VA• DPBF50-80 210VA 15VA

– Built-in auxiliary contact ratings: A600 for all SPST, if any – Screw termination: Torque Wire size

• DPBG12 9lbin AWG8-12• DPBF09-18 13-16lbin AWG8-16• DPBF26-32 22-27lbin AWG6-14• DPBF50-80 35-44lbin AWG18-2

– Operating temperature:• DPBG12: -40...+60°C/-40...+140°F• DPBF: -50...+70°C/-60...+160°F

Certifications and complianceCertifications: UL Listed for USA and Canada (File E93602)under Motor Controllers – Definite purpose contactors.All contactors are CE marked per European Unionrequirements.Compliant with standards: UL 60947-1, UL 60947-4-1, CSA C22.2 n° 60947-1, CSA C22.2 n° 60947-4-1.

DPBF26 T4DPBG12T4

Definite purpose contactorsThree-pole and four-pole non-reversing DP contactors 600VAC

NOTE: All types have undergone ULendurance tests of 250,000 cycles.

44(1.73”)

4.4(0.17”)

8.5(0.33”)

9.7(0.38”)

4.4(0.17”)

8.5(0.33”)

8.5(0.33”)

34.9(1.37”)

57(2.24”)

50(1

.97”

)58

(2.2

8”)

4(0

.16”)

DIMENSIONS [mm (in)]DPBG12, 3 and 4 poles

DPBF26-DPBF32, 3 poles DPBF26, 4 poles

DPBF50-DPBF80, 3 poles DPBF50-DPBF80, 4 poles

DPBF09-DPBF12-DPBF18, 3 and 4 poles45

(1.77”)

81(3

.19”

)

4.2(0

.17”)6.2

(0.24”)10.9

(0.43”)80.7

(3.18”)

35(1.38”)

71(2

.79”

)

61(2.40”)

90(3

.54”

)

4.2(0

.17”)14.6

(0.57”)90

(3.54”)

35(1.38”)

80(3

.15”

)

7.9(0.31”)

15.9(0.62”)

45(1.77”)

90(3

.54”

)

4.2(0

.17”)14.6

(0.57”)90

(3.54”)

35(1.38”)

80(3

.15”

)

7.9(0.31”)

55 (2.16”)9

(0.35”)18.5

(0.73”)

146

(5.7

5”)

114.5 (4.51”)

136

(5.3

5”)

125

(4.9

2”)

45 (1.77”)

110

(4.3

3”)

Ø4.5

(0.18

”)9

(0.35”)18

(0.71”)45 (1.77”)

110

(4.3

3”)

114.6 (4.51”)

136

(5.3

5”)

125

(4.9

2”)

Ø4.5

(0.18

”)

Code Voltage range024 60 24VAC 60Hz120 60 120VAC 60Hz230 60 230VAC 60Hz460 60 460VAC 60Hz575 60 575VAC 60Hz

Page 3: Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

Definite purpose contactorsAdd-on blocks - Accessories - Spare parts

Characteristics Max Catalogqty per numbercontactorn°

Auxiliary contacts with front center mounting.Screw terminals.2NC 1 BGX10 021NO + 1NC 1 BGX10 112NO 1 BGX10 204NC 1 BGX10 041NO + 3NC 1 BGX10 132NO + 2NC 1 BGX10 223NO + 1NC 1 BGX10 314NO 1 BGX10 40Mechanical interlock.For DPBG12 side by side 1 BGX50 00Quick connect surge suppressors.≤48VAC/DC (Varistor) BGX77 04848-125VAC/DC (Varistor) BGX77 125125-240VAC/DC (Varistor) BGX77 240≤225VDC (Diode) BGX78 225≤48VAC (Resistor-Capacitor) BGX79 04848-125VAC (Resistor-Capacitor) BGX79 125125-240VAC (Resistor-Capacitor) BGX79 240240-415VAC (Resistor-Capacitor) BGX79 415Modular protection cover.Raises protection to IP40 BGX80 00�

Rigid connecting kits for reversing contactor assembly.For DPBG12 side by side with SMX90 22BGX50 00 interlock Spare partsNO COIL REPLACEMENT FOR DPBG CONTACTORS IS POSSIBLE.

� The protection cover can be used with no auxiliary contacts, surgesuppressor or mechanical interlock mounted.

Certifications and complianceCertifications for DPBG12 accessories:Type cULus CSABGX10… � ––BGX50 00 � ––BGX7… � ––BGX80 00 � ––SMX90 02 � ––For DPBF accessories:BFX42-BFX43 � ––BFX10-BFX12… �

G418-G428… � �

BFX50… � ––BFX7… � ––G269 2 � �

BFX31… � ––

� UL Recognized for USA only (File E197069) as Panel and SwitchboardAccessories – Component.

� UL Recognized for USA only (File E93601) as Auxiliary devices –Component.

cULus – UL Listed for USA and Canada (File E93601) as Auxiliary devices.CSA – CSA certified for Canada only (File 54332) as Auxiliary devices for motorcontrollers.All products are also CE marked per European Union requirements.Comply with standards: UL 508, CSA C22.2 n°14.

Add-on blocks - Accessories for DPBG12 type

Characteristics Max Catalogqty per numbercontactorn°

Fourth pole.For DBBF26-DPBF32 contactors 1 BFX42For DBBF50-DPBF80 contactors 1 BFX43Auxiliary contacts with front center mounting. Screw terminals.2NC 1 BFX10 021NO + 1NC 1 BFX10 112NO 1 BFX10 204NC 1 BFX10 041NO + 3NC 1 BFX10 132NO + 2NC 1 BFX10 223NO + 1NC 1 BFX10 314NO 1 BFX10 40Auxiliary contacts for front lateral mounting. Screw terminals.1NO 2 G418 101EM (Early Make) 2 G418 10A1NC 2 G418 011LB (Late Break) 2 G418 01DAuxiliary contacts for side mounting. Screw terminals.1NO 2 G428 101EM (Early Make) 2 G428 10A1NC 2 G428 011LB (Late Break) 2 G428 01D2 NC for DPBF09-DPBF32 2 BFX12 02contactors1NO+1NC for 2 BFX12 11DPBF09-DPBF32 contactors2NO for DPBF09-DPBF32 2 BFX12 20contactorsMechanical interlocks.Side mount for 1 BFX50 00DPBF09-32 contactorsSide mount with 2NC contacts 1 BFX50 01for DPBF09-32 contactorsFront mount low profile for 1 BFX50 02DPBF09-32 contactorsFront mount for 1 BFX50 03DPBF09-32 contactorsSide mount for 1 BFX53 00DPBF50-80 contactorsSide mount with 2NC contacts 1 BFX53 01for DPBF50-80 contactorsFront mount for 1 BFX53 03DPBF50-80 contactorsSurge suppressors, quick connect to DPBF09-DPBF80.≤48VAC (Varistor) BFX77 04848-125VAC (Varistor) BFX77 125125-240VAC (Varistor) BFX77 240≤48VAC (Resistor-Capacitor) BFX79 04848-125VAC (Resistor-Capacitor) BFX79 125125-240VAC (Resistor-Capacitor) BFX79 240240-415VAC (Resistor-Capacitor) BFX79 415

Characteristics Catalognumber

Rigid connecting kits for three-pole reversing contactorassembly.For DPBF09-18 side by side with BFX31 01BFX50 02 or BFX50 03 interlockFor DPBF09-18 side by side with BFX31 02BFX50 00 or BFX50 01 interlockFor DPBF26-32 w/ BFX50... interlock BFX32 01Protection cover.For DPBF09-32 contactors BFX80Screw fixing adapters.Universal base to screw fix BFX89 01DPBF09-32 contactorsScrew fixing brackets for BFX89 02DPBF09-32 contactorsSpare partsFor DPBF contactors, standard coil voltages and frequency.Four-terminal coil for DPBF09-18 types.60Hz 24VAC BFX91A 024 60

48VAC BFX91A 048 60120VAC BFX91A 120 60220VAC BFX91A 220 60230VAC BFX91A 230 60460VAC BFX91A 460 60575VAC BFX91A 575 60

Four-terminal coil for DPBF26-32 types.60Hz 24VAC BFX92A 024 60

48VAC BFX92A 048 60120VAC BFX92A 120 60220VAC BFX92A 220 60230VAC BFX92A 230 60460VAC BFX92A 460 60575VAC BFX92A 575 60

Two-terminal coil for DPBF50-80 types.60Hz 24VAC BFX93A 024 60

48VAC BFX93A 048 60120VAC BFX93A 120 60220VAC BFX93A 220 60230VAC BFX93A 230 60460VAC BFX93A 460 60575VAC BFX93A 575 60

NOTE:Other coil voltages and frequencies, add-on accessories,contact blocks are available. Contact Customer Service for partnumbers, detailed information and technical data; see contactdetails on back cover.

Add-on blocks - Accessories - Spare parts for DPBF types

Page 4: Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

Definite purpose contactorsDimensions [mm (in)]

ADD-ON BLOCKS ON DPBG12 CONTACTORS

ADD-ON BLOCKS ON DPBF09-32 CONTACTORS

BGX10... auxiliary contacts

44(1.73”)

82(3.23”) 26

(1.02”)

58(2

.28”

)

30(1

.18”

)

BGX80 00 cover

BGX80 00

58(2

.28”

)

44(1.73”) 59

(2.32”)

48.5

(1.9

1”)

BGX50 00 interlock with BGX10... and BGX77 or BGX78 orBGX79 suppressor

BGX10... - BGX77...BGX78... - BGX79...BGX50 00

88(3.46”)

58(2

.28”

)

88(3.46”)

26(1.02”)

30(1

.18”

)

6(0.24”)

BGX77 or BGX78 or BGX79...suppressor only

BGX77... - BGX78... BGX79...

44(1.73”)

58(2

.28”

)

7.75(0.30”)

56(2.20”)

26(1.02”)

23.8

(0.9

4”)

88(3.46”)

6(0.24”)

34.9(1.37”)

50(1

.97”

)

Ø4(0

.16”)80

(3.15”)7 (0.28”)

7 (0.28”)

BGX50 00

SMX90 22

SMX90 22 rigid connectors with BGX50 00 interlock for reversing contactors

84.8(3.34”)

16(0.63”)

90(3

.54”

)

15.9(0.62”)

Fourth pole BFX42

ADD-ON BLOCKS ON DPBF50-80 CONTACTORS

10(0.39”)

BFX5300 - BFX5301 interlock for reversing contactors

31.9(1.15”)

41(1

.61”

)

15(0.59”)

BFX5303 interlock for reversing contactors

21.4(0.84”)

29(1.14”)

41.4

(1.6

3”)

Auxiliary contacts BFX10... w/2 contacts42.8

(1.68”)

36.5(1.44”)

41.4

(1.6

3”)

BFX10... w/4 contacts8

(0.31”)

28(1.10”)

46(1

.81”

)

G418... w/1 contact

10(0.39”)

75.4 (2.97”)

61.5

(2.4

2”)

9.9

(0.3

5”)

BFX12... w/2 contacts9.5

(0.37”)57

(2.24”)

51(2

.01”

)

12.3(0.48”)

G428... w/1 contact10

(0.39”)

BFX50 00, BFX50 01 interlock15

(0.59”)

31.9(1.15”)

41(1

.61”

)

BFX50 03 interlock

90(3.54”)

90(3.54”)

35(1.38”)

Ø4.2

(0.16

”)

83 (3

.27”

)

71 (2

.79”

)

BFX31 01BFX50 02

BFX31 01 rigid connectors with BFX50 02 interlock for reversing contactors

45(1.77”)

31.8(1.25”)

11.6(0.46”)

35(1.38”)

14.5(0.57”)

45 (1

.77”

)75

(2.9

5”)

86(3

.38”

)

Ø4.3(0.17”)

Ø4.3(0.17”)

Ø3.5(0.14”)

BFX89 01 fixing base

10(0.39”)Ø4.3

(0.17”)

16 (0

.63”

)

9.7(0.38”)

21(0

.83”

)

BFX89 02 fixing bracket

45(1.77”) 4.5

(0.18”)

39.2

(1.5

4”)

BFX80 cover

Page 5: Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

Definite purpose contactorsMounting combinations of add-on blocks and accessories

DPBG12

BGX10 40BGX10 31BGX10 22BGX10 13BGX10 04

BGX10 20BGX10 11BGX10 02

BGX77…BGX78 225BGX79…

BGX80 00

BGX77…BGX78 225BGX79…

BGX10 40BGX10 31BGX10 22BGX10 13BGX10 04

BGX10 20BGX10 11BGX10 02

BGX10 40BGX10 31BGX10 22BGX10 13BGX10 04

BGX50 00

BGX10 20BGX10 11BGX10 02

BGX77…BGX78 225BGX79…

DPBG12

SMX90 22

SMX90 22

DPBG12

DPBF09-18

DPBF26-32

BFX80

BFX31 01BFX31 02BFX32 01

BFX50 02

BFX50 03

BFX31 01BFX31 02BFX32 01

BF...A

BFX50 00BFX50 01

BFX50 02BFX50 03

� Mounting not possible if front lateral contacts or mechanical interlocks BFX50.../G269 2 are mounted.� Only for DPBF09-32 types.

BFX50 00BFX50 01(only for DPBF09-32contactors)BFX53 00BFX53 01(only for DPBF50-80contactors)

BFX77…BFX79…(only forDPBF09-32contactors)

DPBF…

BFX10…

G418…

G318...G319 225G322...

BFX50 02(only for DPBF09-32contactors)

BFX50 03(only for DPBF09-32contactors)

BFX53 03(only for DPBF50-80contactors)

G428…�

BFX10…

BFX12...

BFX42 (only forDPBF26 and DPBF32)BFX43 (only forDPBF50 and DPBF80)

DPBG12 TYPE

DPBF TYPES

DPBF09-32 assembled as reversing contactors

Assembled as reversing contactors

Page 6: Definite purpose contactors · 2017-04-05 · Definite purpose contactors Add-on blocks - Accessories - Spare parts Characteristics Max Catalog qty per number contactor n° Auxiliary

PD85

CND

USA

02

17

The

prod

ucts

des

crib

ed in

this

pub

licat

ion

are

subj

ect t

o be

revi

sed

or im

prov

ed a

t any

mom

ent.

Cata

log

desc

riptio

ns a

ndde

tails

, suc

h as

tech

nica

l and

ope

ratio

nal d

ata,

dra

win

gs, d

iagr

ams

and

inst

ruct

ions

, etc

., do

not

hav

e an

y co

ntra

ctua

l val

ue.

In a

dditi

on, p

rodu

cts

shou

ld b

e in

stal

led

and

used

by

qual

ified

per

sonn

el a

nd in

com

plia

nce

with

the

regu

latio

ns in

forc

e fo

rel

ectri

cal s

yste

ms

in o

rder

to a

void

dam

ages

and

saf

ety

haza

rds

LOVATO ELECTRIC CORP.3200 Avenue Jacques BureauLAVAL QC H7P OA9 CanadaTel. (450) 681-9200Fax (450) 681-9884Email: [email protected]

www.Lovato.ca

Definite purpose contactorsThermal overloads - Electrical and Mechanical Life Data

Thermal overloads for DPBF typesSingle phase sensitive, three pole types

Electrical life Mechanical life

DIMENSIONS [mm (in)]DPBF09-32 contactors with RF38 overload

DPBF50-80 contactors with RF82 overload

DPBG12 and DPBF09-32: 20 million cyclesDPBF50-80: 15 million cycles.

NOTE: Other adjustment ranges, non-single phase sensitive or 2-pole types and accessories are available, ContactCustomer Service for part numbers and technical information; see contact details below.

Notes for installation For single or two-wire supply configurations with DPcontactors, directly connect respectively to one or twocontactor poles, leaving the others unwired.If a three-pole overload is installed with single-phase motors,the overload terminal L2 needs to be jumpered with terminalT3; the line is connected to L1-L3 terminals while the load(motor) to terminals T1 and T2.

For DPBF09-32 types Adjustment Catalog range number [A] MANUAL OR AUTOMATIC RESETTING. Direct mount on DPBF09-32� types. Independent mounting with RFX38 04 base. 4-6.5 RF38 0650 6.3-10 RF38 1000 9-14 RF38 1400 13-18 RF38 1800 17-23 RF38 2300 20-25 RF38 2500 24-32 RF38 3200 32-38 RF38 3800� If a range higher than 32-38A is required, the

RF95 type needs to be considered; the links mustbe changed. Contact Customer Service forassistance and details; contact details are given atthe bottom of the page.

For DPBF50-80 types Adjustment Catalog range number [A] MANUAL RESETTING. Direct mount on DPBF50-80 types. Independent mounting with G270 base. 28 - 42 RF82 4200 35 - 50 RF82 5000 46 - 65 RF82 6500 60 - 82 RF82 8200 AUTOMATIC RESETTING. Direct mount on DPBF50-80 types. Independent mounting with G270 base. 28 - 42 RFA82 4200 35 - 50 RFA82 5000 46 - 65 RFA82 6500 60 - 82 RFA82 8200

RF...38RF...38

45(1.77”)

81.2(3.20”)

7.9(0.31”)

81(3

.19”

)

4.2(0

.17”)

126

(4.9

6”)

6.2(0.24”)

10.9(0.43”)

14.6(0.57”)

80.7(3.18”)

35(1.38”)

71(2

.79”

)

55 (2.16”)9

(0.35”)18.5

(0.73”)

194

(7.6

4”)

114.5 (4.51”)

136

(5.3

5”)

125

(4.9

2”)

45 (1.77”)

110

(4.3

3”)

Ø4.5

(0.18

”)

LOVATO ELECTRIC INC.2017 Georgetown Blvd.CHESAPEAKE, VA 23325 USATel. (757) 545-4700Fax (757) 545-2900Email: [email protected]

www.LovatoUsa.com

DPBG

12

DPBF

09A

DPBF

18A

DPBF

26A

DPBF

12A

DPBF

32A

DPBF

50

DPBF

80

14 20 25 30 40 50 70 80 100 [A]1010.1

0.5

1

10

MIL

LION