1 August 2003 Predictive Engineering Consulting Davis Energy Group / National Energy Renewal Laboratory (NREL): Structural analysis modeling and optimization of a low-cost, plastic solar panel for the heating of water. FEA results were used to ensure the structural integrity of the panel under high wind loads. Modeling notes: stress-stiffening was incorporated into the model to more accurately predict the polycarbonate glazing’s deflection and stress behavior.
5

Davis Energy Group / National Energy Renewal Laboratory ...

May 13, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Davis Energy Group / National Energy Renewal Laboratory ...

1A

ug

ust

200

3Predictive Engineering Consulting

Davis Energy Group / National Energy Renewal Laboratory (NREL):Structural analysis modeling and optimization of a low-cost, plastic solarpanel for the heating of water. FEA results were used to ensure thestructural integrity of the panel under high wind loads. Modeling notes:stress-stiffening was incorporated into the model to more accuratelypredict the polycarbonate glazing’s deflection and stress behavior.

Page 2: Davis Energy Group / National Energy Renewal Laboratory ...

2A

ug

ust

200

3Predictive Engineering Consulting

Davis Energy Group (DEG) SunCache CAD geometry used for this analysis.

Page 3: Davis Energy Group / National Energy Renewal Laboratory ...

3A

ug

ust

200

3Predictive Engineering Consulting

The von Mises stress is contoured over the structure. The stress legend is capped at30,000 psi. Additional, more detailed structural information is given later in this report.

Page 4: Davis Energy Group / National Energy Renewal Laboratory ...

4A

ug

ust

200

3Predictive Engineering Consulting

Peak deflection in the panel is 3.8 inches.

Page 5: Davis Energy Group / National Energy Renewal Laboratory ...

5A

ug

ust

200

3Predictive Engineering Consulting

The structural steel components all fall within the targeted stress level of 60,000 psi.