Daikin Air Conditioning Daikin air conditioners for shops, restaurants and offices. CONCEALED CEILING UNIT UK Price List Attached Correct as of 15/04/08 Please check http://global-cooling.co.uk For the latest information For more information about this range of air conditioning systems http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/ If you need any help please call us on 01200 428888 Or use Live Chat UK Price List Attached Please check the here for latest specifications and prices. Global Cooling Air Conditioning UK www.global-cooling.co.uk Upbrooks Industrial Estate Clitheroe, Lancashire BB7 1PL, UK UK Air Conditioning Online Shop - http://global-cooling.com/ Air Conditioning Forum - http://air-conditioning-forum.global-cooling.co.uk/
Concealed ceiling units are built into the false ceiling, leaving only the suction and discharge grilles visible. Because of this the grilles can be placed wherever you want and blend with any interior decor. The grilles allow uniform temperature distribution in large or heavily partitioned areas.
Not only are concealed ceiling units visually unobtrusive, they are also among the quietest types of air conditioning. Brochure & UK Prices
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Daikin Air Conditioning Daikin air conditioners for shops, restaurants and offices. CONCEALED CEILING UNIT UK Price List Attached Correct as of 15/04/08 Please check http://global-cooling.co.uk For the latest information
For more information about this range of air conditioning systems http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/ If you need any help please call us on 01200 428888 Or use Live Chat UK Price List Attached Please check the here for latest specifications and prices. Global Cooling Air Conditioning UK www.global-cooling.co.uk Upbrooks Industrial Estate Clitheroe, Lancashire BB7 1PL, UK UK Air Conditioning Online Shop - http://global-cooling.com/ Air Conditioning Forum - http://air-conditioning-forum.global-cooling.co.uk/
• You have the choice of 2 fan speeds to select: high or low. A high fan speed providesmaximum reach while a low fan speed minimizes draughts.
• The indoor unit is very quiet in operation. The sound levels are as low as 29dB (A),comparable to rustling leaves.
• Daikin’s special dry programme reduces humidity in the room without variations inroom temperature.
• The indoor unit contains an air filter which removes microscopic particles and dust.
COMFORT
Concealed ceiling units are built into the false ceiling, leaving only thesuction and discharge grilles visible. Because of this the grilles can be placedwherever you want and blend with any interior décor. The grilles allow uniformtemperature distribution in large or heavily partitioned areas.Not only are concealed ceiling units visually unobtrusive, they are also among thequietest types of air conditioning.
hayez_EPLE05-21B 14/03/06 10:02 Page 2
mov93585_EPLe05-21b
Cyan Magenta Yellow Black
Wired remotecontrol (Optional)
• The air discharge unit can be separated from the actual air conditioner for use in long,L-shaped or U-shaped rooms by means of flexible duct systems (ESP up to 88Pa).In this way even irregularly shaped rooms can be kept comfortable.
L-shaped room U-shaped room Long room
111
2
2
suction grille
discharge grille (field supply) of the flexible ducts2
1
• The outdoor unit can be installed on a roof or terrace or placed against an outside wall.
• Special anti-corrosion treatment of the outdoor unit’s heat exchanger fin, givesgreater resistance against acid rain and salt corrosion. Additional resistance is providedby a rust proof steel sheet on the underside of the unit.
• Daikin remote controls give you easy control at your fingertips.
• The wired remote control provides you with a schedule timer, enabling to program theair conditioning daily or weekly.
• The optional remote ON/OFF enables you to start/stop the air conditioning from amobile phone via a telephone remote control (field supply). The optional forced OFF enables you to switch off the unit automatically. E.g. when awindow is opened, the unit switches off.
Heat exchanger
An anti-corrosion heatexchanger cutaway view
Aluminium
Hydrophilic film
Corrosion-resistantAcrylic resin
• Since the indoor unit has a low height it fits flush into narrow ceiling voids.The installation of the unit requires a false ceiling of only 350mm (when suction panelis used).
FLEXIBLE INSTALLATION AND EASY TO USE
2
hayez_EPLE05-21B 14/03/06 10:02 Page 3
mov93585_EPLe05-21b
Cyan Magenta Yellow Black
ENERGY EFFICIENT
• This model can be used both in cooling only or heating.
• It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin,triple, double twin (connecting up to 4 indoors in the same room to a single outdoor)and multi applications (connecting up to 9 units in several rooms to 1 outdoor unit).
APPLICATION OPTIONS
Inverter air conditioning
Non inverterair conditioning
Set point
Large temperaturedifference
Repeats hot and cold cycles
Keeps temperature stable
Startup time reducedby about 1/3
Slow start-up
Improved comfort:The rapid start up time provided by the inverter increases comfort by reducing the leadtime in obtaining the required indoor temperature. As soon as the required temperatureis reached, the inverter unit continuously scans the room for small changes and adjuststhe room temperature in seconds, thereby increasing comfort once again.
• The ‘home leave’ operation button prevents large temperature differences by continuouslyoperating at a minimum (heating mode) or maximum (cooling mode) preset level whileyou’re out or sleeping. It also allows the indoor temperature to return quickly to yourfavourite comfort level.
Smallertemperaturedifference
• Energy label: up to class A
• Inverter technologyImproved energy efficiency:The use of integrated inverter control ensures maximum energy efficiency by supplyingonly the required heating or cooling load where a standard non inverter unit would supplymaximum load in an on/off regime.
When you go out pushthe “Home leave operation”button, and the airconditioner will adjustcapacity to reach the presettemperature for “Homeleave operation”.
When you return, you will bewelcomed by a comfortableair-conditioned room.
Push the “Home leaveoperation” button again,and the air conditioner willadjust capacity to the settemperature for normaloperation.
ONE PUSH PUSH AGAINWhile out of the home
hayez_EPLE05-21B 14/03/06 10:02 Page 4
mov93585_EPLe05-21b
Cyan Magenta Yellow Black
Notes:1) Energy label : scale from A (most efficient) to G (less efficient).2) Annual energy consumption: based on average use of 500 running hours per year at full load (= nominal conditions)
Capacity and power inputCOOLING ONLY - INVERTER CONTROLLED (air cooled)
Cooling capacity min~nom~max kWNominal input nominal kWEEREnergy labelAnnual energy consumption cooling kWhCOOLING ONLY - NON INVERTER (air cooled)
2.54/2.65 2.64/2.78 2.613.21 2.86/2.89 3.21E/D D/C DC D/D C
1,395/1,340 1,885/1,780 2,335
Notes: (1) The indicated cooling, heating capacities and power input are indicative and are those connected to wall mounted D (25,35 class) /E (50, 60 class) series.(2) For more detailed information, please consult our multi model/combination tables catalogue or your local dealer.*At least two indoor units should be connected to these multi outdoor units.
POSSIBLECOMBINATIONSMULTI - COOLING ONLY
Max. n° of indoor unitsFBQ35BFBQ50BFBQ60B
Max. cooling capacity kWMax. PI cooling kW
Cooling only
4MK
S58E
(1)
4MK
S75E
(1)
5MK
S90E
(1)
• • •• • •• •
4 4 5
7.30 9.28 10.502.24 3.54 3.98
POSSIBLECOMBINATIONSMULTI - HEAT PUMP
Max. n° of indoor unitsFBQ35BFBQ50BFBQ60B
Max. cooling capacity kWMax. heating capacity kWMax. PI cooling kWMax PI heating kW
* Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will recover when temperature rises again.- Information is not available.
COOLING ONLY - INVERTER CONTROLLED
Dimensions HxWxD mmWeight kgCasing colourSound pressure level H/L dB(A)Sound power level H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range from ~ to °CDBCOOLING ONLY - NON INVERTER
Dimensions HxWxD mmWeight kgCasing colourSound pressure level H dB(A)Sound power level H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range from ~ to °CDBHEAT PUMP - INVERTER CONTROLLED
Dimensions HxWxD mmWeight kgCasing colourSound pressure level cooling H/L dB(A)(night quiet mode) heating H/L dB(A)Sound power level cooling H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range cooling from ~ to °CDB
heating from ~ to °CWBHEAT PUMP - NON INVERTER
Dimensions HxWxD mmWeight kgCasing colourSound pressure level cooling H dB(A)Sound power level cooling H dB(A)CompressorRefrigerant typeRefrigerant charge kg/mMaximum piping length mMaximum level difference mOperation range cooling from ~ to °CDB
INDOOR UNITS FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B
Wired remote control BRC1D52Centralised remote control DCS302C51Unified ON/OFF control DCS301B51Schedule timer DST301B51Adapter for wiring KRP1B54Adapter for external ON/OFF and monitoring KRP4A51Interface adapter for Sky Air DTA112B51Remote ON/OFF, forced OFF EKROROOption PCB for external electrical heater, humidifier EKRP1B2and/or hour meter*
*Electrical heater, humidifier and hour meter are field supply. These parts should not be installed inside the equipment.
Accessories: control systems
INDOOR UNITS FBQ35B FBQ50B FBQ60B FBQ71B FBQ100B FBQ125B
Notes: 1) V1 = 1~,230V,50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz; V3 = 1~, 230V, 50Hz2) Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.3) Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.5) Units should be selected on nominal capacity. Max. capacity is limited to peak periods.6) The sound pressure level is measured at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. 7) The sound power level is an absolute value indicating the "power" which a sound source generates.
OUTDOOR UNITS
Air direction adjustment grilleCentral drain plugOUTDOOR UNITS
Central drain plugRefrigerant for twinbranch piping for triple
for double twinDemand adapter kit remote control of sound reduction and power input
EPLE
05-2
1B /
2,175
/ 03
/06
/ La
Mov
ida
Prin
ted
on
no
n-c
hlo
rin
ated
pap
er /
Pri
nte
d i
n B
elg
ium
Daikin products are distributed by:
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikineurope.com
Daikin’s unique position as a manufacturerof air conditioning equipment, compressorsand refrigerants has led to its closeinvolvement in environmental issues. Forseveral years Daikin has had the intention tobecome a leader in the provision ofenvironmental friendly products. Thischallenge demands the eco design anddevelopment of a wide range of productsand an energy management system; whichinvolves energy conservation and reductionof waste.
“The present leaflet is drawn up by way of information only anddoes not constitute an offer binding upon Daikin Europe N.V..Daikin Europe N.V. has compiled the content of this leaflet tothe best of its knowledge. No express or implied warranty isgiven for the completeness, accuracy, reliability or fitness forparticular purpose of its content and the products and servicespresented therein. Specifications are subject to change withoutprior notice. Daikin Europe N.V. explicitly rejects any liability forany direct or indirect damage, in the broadest sense, arisingfrom or related to the use and/or interpretation of this leaflet.All content is copyrighted by Daikin Europe N.V.”
Daikin Europe N.V. is approved by LRQA for itsQuality Management System in accordance withthe ISO9001 standard.ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as toservices related to the product.
ISO14001 assures an effective environmentalmanagement system in order to help protect humanhealth and the environment from the potentialimpact of our activities, products and services andto assist in maintaining and improving the qualityof the environment.
Daikin units comply with the European regulationsthat guarantee the safety of the product.
Daikin Europe N.V. participates in the EuroventCertification Programme for Air Conditioners (AC),Liquid Chilling Packages (LCP) and Fan Coil Units(FC); the certified data of certified models are listedin the Eurovent Directory. Multi units are Euroventcertified for combinations up to 2 indoor units.
hayez_EPLE05-21B 14/03/06 10:02 Page 8
mov93585_EPLe05-21b
Cyan Magenta Yellow Black
Global Cooling Air Conditioning UK Prices*
Daikin Concealed Ceiling Unit – COOLING ONLY TYPES
Features Nom cooling Nom heating Uk cool
UK Cool
Uk heat - - Inter wires - - Max pipe - - - - Price
Daikin Inverter Models Cooling Only types below Min~norm~max Min~norm~max T/C
kw S/C kw kw Run
amps Fuse connecting Liquid Suction separation Max level
*Please check the following page for latest specifications. http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/
Please see the next page for heat pump type prices.
Global Cooling Air Conditioning UK Prices*
Daikin Concealed Ceiling Unit – HEAT PUMP TYPES
Features Nom cooling Nom heating Uk cool
UK Cool
Uk heat - - Inter wires - - Max pipe - - - - Price
*Please check the following page for latest specifications. http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/concealed-ceiling-airconditioning/
If you need any help please call us on 01200 428888