Top Banner
CPA Micarta Based Rahul Sharma / Bill Sands
21

CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Jan 20, 2016

Download

Documents

Peter Greene
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

CPA Micarta Based

Rahul Sharma / Bill Sands

Page 2: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

The present design shown in this document is based on the use of Micarta as the base material this will likely change the design will work with G-10 or other materials with minor changes due to material strengths.

Page 3: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

24 Panel 3 section Micarta CPA Weight ~ 1400 lbs.12 parallel plate sections

Page 4: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

CPA Overall Dimensions

Page 5: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Main Hanger G-106 Pcs. Required

Page 6: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Main Hanger Dimensions

Page 7: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Main hanger internal stainless steel reinforcement

Page 8: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Tubes are fitted inside one and other and fastened with FH screws the horizontal tubes have stainless steel reinforcement tubes at the joints as they are subjected to loading

Page 9: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Each vertical section consists of 2 tubes and 3 stainless steel hangers to support a column of 4 parallel plate sections

Page 10: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Parallel plates are connected to 3” wide strips with tapped holes to connect the panels

Page 11: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Example of a 2 plane middle section weight ~100 lbs.

Page 12: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Center joint connecting middle section to the end sections

Page 13: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Center joint has the vertical connector dropped in after the tube is slide as do the other vertical joints this joint also brings HV from one section to the other

Page 14: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

½” tapped pins connect the vertical sections

Page 15: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Shear pin connection pin and oversized head screws

Page 16: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.
Page 17: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Cryo testing of the Micarta and G-10 demonstrate that the tensile strengths in both materials do rather well in a cryo state

Page 18: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Stainless steel elbow to vertical tube connection

Horizontal tube to elbow connection with column pin connector

Page 19: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Swivel tee for HV connection

Page 20: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Slots cut into top and bottom panels to allow liquid argon flow between panels

Page 21: CPA Micarta Based Rahul Sharma / Bill Sands. The present design shown in this document is based on the use of Micarta as the base material this will likely.

Conclusion

• This document demonstrates that this is a viable design for construction of the CPA the design will likely need to be tweaked with a change in material.