This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Current carrying capacityThe current carrying capacity is limited by maximum temperatureof materials for inserts and contacts including terminals. Thecurrent capacity-curve is valid for continuous, not interruptedcurrent-loaded contacts of connectors when simultaneous poweron all contacts is given, without exceeding the maximum tempe-rature.
Control and test procedures according to DIN IEC 60 512-3.
Wor
king
cur
rent
Ambient temperature
Wire gauge: 1 mm2
Staf 6 Staf 14 Staf 20
Specifications DIN VDE 0627DIN VDE 0110
Approvals , , SEV, BVS,CERCHAR, SABS
InsertsNumber of contacts 6, 14, 20, 40 (2 x 20)Working current 10 A max.
(see current carrying capacity)Working voltage 25 V ~ / 60 V –Test voltage Urms 1.5 kVPollution degree 3 (C)Insulation resistance ≥ 1010 ΩMaterial PolyamideTemperature range - 40 OC … +100 OCFlammability acc. to UL 94 HBMechanical working life
- Mating cycles ≥ 500Working voltageacc. to UL/CSA 50 V
Staf 6 additional thermoplastic resinFlammability acc. to UL 94 V 0
Surface powder-coated RAL 7037Locking element Steel, zinc platedHoods/Housings sealing NBRTemperature range - 40 OC … +125 OCDegree of protection acc. to DIN40 050 for coupled connector IP 65 in plastic housings
Staf 6 IP 44 in metal housings
Further selectionof hoods/housings chapter 30
AccessoriesCable clamps chapter 40Coding of hoods/housings chapter 40Label acc. to CSA-approval chapter 40Test connectors chapter 20
Staf
09.11
Number of contacts
6
Staf
Screw terminal Staf
09 70 006 2813 09 70 006 2616
Solder terminal Staf
09 70 006 2812 09 70 006 2615
Staf 6
Part No.
Identification Series Female insert (M) Male insert (F) Drawing Dimensions in mm
Inserts
Contact arrangementView from termination side
Contact arrangementView from termination side
Mounting example
25 V ~ 10 A60 V –
Stock items in bold type
09.12
Staf
Hoods/Housings metal Size 3 A
Part No.
Identification Standard Han M Han U Pg Drawing Dimensions in mm
Hoo
dsH
ousi
ngs
1) for mounted male insert 2) for mounted female insert