This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Current carrying capacityThe current carrying capacity is limited by maximum temperatu-re of materials for inserts and contacts including terminals . The current capacity-curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum tempe-rature .
Control and test procedures according to DIN IEC 60 5 1 2 - 5 .
Wor
king
cur
rent
Ambient temperature
Wire gauge: 1 mm2
Specifications DIN VDE 0627 DIN VDE 0110 DIN EN 61 984
Approvals , , SEV
InsertsNumber of contacts 6, 14, 20, 40 (2 x 20)
Electrical data acc . to DIN EN 61 984 Working current 10 A Working voltage ~ 25 V / – 60 V
Working voltage acc . to UL/CSA 50 V
Insulation resistance ≥ 1010 ΩMaterial PolyamideLimiting temperatures - 40 OC / +100 OCFlammability acc . to UL 94 HBMechanical working life
In accordance with the appropriate regulation a wire-end sleeve has to be used at clamps without wire protection (s . p . 00 .12) .
Hoods/Housings thermoplastic, Size 3 AMaterial Polycarbonate RAL 7032Locking element Polyamide RAL 7032Flammability acc . to UL 94 V 0Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCDegree of protection acc . to DIN EN 60 529 for coupled connector IP 44
Hoods/Housings metalMaterial Die cast aluminium alloy Material size 3 A Die cast zinc alloyLocking element Han-Easy Lock®
Locking element size 3 A Steel, zinc platedFlammability acc . to UL 94 V 0Hoods/Housings seal NBRLimiting temperatures - 40 OC / +125 OCDegree of protection acc . to DIN EN 60 529 for coupled connector IP 44
Further selection of hoods/housings chapter 30 / chapter 31
AccessoriesCable clamps chapter 40Coding of hoods/housings chapter 40Label acc . to CSA-approval chapter 40Test connectors chapter 20
Staf
09.11
Staf ® 6 ~ 25 / – 60 V 10 A
Number of contacts
6
Screw terminal Staf®
09 70 006 2813 09 70 006 2616
Solder terminal Staf®
09 70 006 2812 09 70 006 2615
Part No .
Identification Series Female insert (M) Male insert (F) Drawing Dimensions in mm
Inserts
Contact arrangement View from termination side
Contact arrangement View from termination side
Mounting example
Stock items in bold type
Size 3 A
Staf
09.12
09 20 003 0801
09 20 003 0301
19 20 003 1250 20
19 20 003 1252 20
19 20 003 1150 20
19 20 003 1750 20
09 20 003 54221)
09 20 003 54212)
09 20 003 54261)
09 20 003 54252)
09 20 003 54281)
09 20 003 54272)
09 20 003 03051)
09 20 003 03062)
19 20 003 1640 20
19 20 003 1440 20
Hoods/Housings metal Size 3 A
Identification Part No . M Drawing Dimensions in mm
1) for mounted male insert 2) for mounted female insert Stock items in bold type
Hoo
dsH
ousi
ngs
Panel cut out 22 x 22 mm
Panel cut out 22 x 22 mm
Housings bulkhead mounting
Housingsurface mounting
1 side-entry
bottom closed
Housingscrew mounting
Hood cable to cable
Protection coversfor hoods
Protection coversfor housings
for hoods cable to cable
with fixed cover without sealing
with sealing
Hoodside-entry
Hoodtop-entry
Staf
09.13
A B
C
A 09 20 003 54071)3)1)
09 20 003 54082)3)4)
B 09 20 003 54452)1)1)
09 20 003 54461)1)1)
09 20 003 54472)3)4)
C 09 20 003 54481)1)1)
Stock items in bold type
Hoods/Housings thermoplastic Size 3 A
Identification Part No . M Drawing Dimensions in mm