METRIC 0.76 996.8 0.91 1197.4 1.22 1593.0 1.52 1992.1 1200 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 1600 20.0 20.0 20.0 20.0 20.0 1800 16.4 18.5 1200 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 1800 18.3 18.3 20.0 20.0 20.0 20.0 2000 15.1 17.0 2200 k 1 = 29.1202 1400 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 2 = 145.8115 1600 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 3 = 0.2552 1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 k 4 = -0.1660 2000 18.6 18.6 20.0 20.0 20.0 20.0 20.0 20.0 2200 15.8 15.8 17.8 17.8 20.0 20.0 2400 13.7 15.4 18.0 2600 12.0 2800 1800 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 2000 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 2200 18.9 18.9 20.0 20.0 20.0 20.0 20.0 20.0 2400 16.4 16.4 18.5 18.5 20.0 20.0 20.0 2600 14.5 14.5 16.3 19.1 20.0 2800 12.9 14.5 3000 11.4 Continued on back HI-BOND COMPOSITE FLOOR HB938 Z275 GALVANIZED Note SECTION MODULUS MIDSPAN S m (mm 3 x 10 3 ) SUPPORT S s (mm 3 x 10 3 ) 9.76 MASS WITH ZF75 GALVANIZED (kg/m 2 ) 2.11 0.088 2.45 0.103 Load Tables are based on the design of ONE-WAY composite slabs carrying uniformly distubuted loads on a simple span basis. For complete design criteria see the VICWEST Hi-Bond Composite Floor Designer's Manual. 1. 2. NOMINAL CORE THICKNESS (mm) AREA OF STEEL (mm 2 ) A uniform loading in excess of 10 kPa (200 psf) is often an indication of concentrated or moving loads. Such conditions may require additional reinforcing steel. Contact VICWEST for additional design information 0.76 0.91 Slab Thickness h, is from underside of steel deck to top of concrete. Maximum span is not to exceed 32h. 3. 2 Span 1.22 20.0 Base Steel Nominal Thickness (mm) h(mm) Slab Weight, W 1 (kN/m 2 ) Concrete Volume, (m 3 /m 2 ) 1.52 7228 1 Span 2 Span 3 Span 103.4 22.16 16.21 20.06 8.08 364.0 12.31 1 Span 78.8 78.7 13.7 12.0 15.8 18.9 12.9 20.0 18.6 14.5 20.0 16.4 3 . 8 2 2 9 5 . 9 454.4 9.65 12.83 11.70 15.87 20.0 20.0 Shear Bond Coefficents (PER METRE WIDTH) In accordance with CSA Specification S136-07 Maximum Specified Uniformly Distributed Load in kN/m 2 (kPa) 15.7 22.3 126 10.9 25.8 MIDSPAN I m (mm 4 x 10 3 ) MAXIMUM FACTORED REACTIONS 274.0 Moment of Inertia 266.8 EXTERIOR (kN) 213.9 15.3 38.4 INTERIOR (kN) 454.4 364.0 22.26 22.45 DEPTH FROM NEUTRAL AXIS TO BOTTOM OF DECK Y b (mm) FULL I f (mm 4 x 10 3 ) 22.65 38.9 58.7 14109 113.6 13244 136 2.68 0.113 I C 113.8 (PER METRE WIDTH) Composite Moment of Inertia, I C (mm 4 x 10 3 ) Effective Depth, d (mm) 20.0 17090 15673 113.4 20.0 3 Span 20.0 113.7 20.0 20.0 20.0 103.6 3 Span 13662 88.4 2 Span 12519 Properties and loads are based on Grade 230 steel (Grade 33 steel) with a minimum yield stress of 230 MPa (33,000 psi) and a maximum stress under Factored loads of 207 MPa (29,700 psi). 20.0 20.0 20.0 20.0 20.0 16.4 20.0 20.0 1 Span 2 Span 3 Span 20.0 20.0 18.5 1 Span 20.0 20.0 20.0 1.89 0.078 20.0 20.0 18.3 15.1 9408 18.0 4. Load values are based on Normal Weight Concrete (density of 2300 kg/m 3 ) (145 pcf) with a minimum compressive strength of 20.7 MPa (3,000 psi) and a Modular Ratio n=9 5. 20.0 20.0 20.0 20.0 17.0 20.0 20.0 20.0 20.0 19.1 20.0 20.0 20.0 20.0 20.0 20.0 15.4 20.0 20.0 20.0 17.8 20.0 20.0 20.0 20.0 14.5 18.5 20.0 20.0 20.0 16.3 20.0 20.0 20.0 20.0 19.9 20.0 20.0 20.0 20.0 20.0 I C d d I C d 103.8 88.8 7725 8613 88.7 10548 88.6 11252 103.7 I C 101 20.00 15.96 111 5455 7121 Base Steel Nominal Thickness (mm) Span (mm) 6516 5836 78.6 78.4 d 1.52 0.76 0.91 1.22 PHYSICAL PROPERTIES STEEL PROPERTIES PHYSICAL PROPERTIES COMPOSITE SLAB LOAD TABLE LIMIT STATES DESIGN SLAB THICKNESS VW00147EN10/10 In accordance with ongoing efforts to improve our products and their performance, Vicwest reserves the right to change without notice the specifications contained herein. The contents herein are for general information and illustrative purposes only and are not intended to serve as any type of advice. Every effort is made to ensure the accuracy of the information included in this brochure and it is believed that the information contained herein is accurate and reliable as of the date of publication. Vicwest, however, does not warrant or represent the accuracy or reliability of any information included in this brochure. Any reliance on any information without consultation with Vicwest or a duly authorized representative shall be at the user's own risk. ©2010, Vicwest – All rights reserved