Top Banner
High-efficiency, modular steam boiler 10-60 HP H CLEARFIRE ®
8

CLEARFIRE - Tundra€¦ · cULus, ASME CSD-1, XL-GAP and FM. • Low gas pressure manual reset • High gas pressure manual reset • CSD-1 test cocks • Manual test valve • Dual

Feb 09, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • High-efficiency, modular steam boiler10-60 HP

    HCLEARFIRE®

  • The ClearFire®-H compact, gas-fired horizontal boiler is designed specifically for the requirements of the light industrial and commercial markets and is available in sizes ranging from 10-60 horsepower for 15# or 150# psig steam pressure.

    Maximum fuel savings with ALUFER® firetubes, full burner modulation and high turndown via variable speed blower

    High efficiency, guaranteed up to 85% reducing greenhouse gas emissions

    Easily tuned, self-regulating, premix burner

    Reliable operation, no dampers or linkages

    Advanced combustion design eliminates need for flue gas recirculation and provides low emissions (

  • The ClearFire®-H Advantage Boilers

    Single-point connection for electrical and controls

    Surface blowoff: automatic conductivity control available

    Modulating low-NOx burner assembly for maximum operating efficiency

    Single-pass firetube design, thermal shock-resistant

    Fiber mesh burner designed to premix air and fuel for optimal combustion

    CSD-1, XL GAP gas train

    Small stack outlet

    Steam outlet, sized for the application

    Large steam volume, better steam quality

    Patented ALUFER® tubes for increased

    heat transfer

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    8

    1 2

    3

    4

    5

    6

    8

    9

    10

    3

    7

  • Patented ALUFER® Heat Transfer Technology

    The internationally patented ALUFER firetube is the technology behind the advanced heat transfer design. The tube is constructed from an inner (fireside) aluminum alloy finned surface, die-fitted within an outer steel tube, providing exceptional heat exchange characteristics.

    • Thermal conductivity of the ALUFER insert is significantly greater than that of carbon steel.

    • Internal finned surface of the ALUFER tube enlarges the heat exchange surface area three-fold.

    • Inner surface of the tube is divided into 10 flow channels to enhance turbulence and maximize heat transfer.

    Heat Exchanger And Burner

    The ClearFire®-H boiler has a high-quality, steel combustion chamber with ALUFER firetubes. The single-pass horizontal arrangement ensures maximum heat exchanger effectiveness and superior steam quality. The high-turndown modulating burner minimizes short cycling and allows the boiler to operate at peak efficiency.

    Thermal Shock Resistance

    The single-pass arrangement is designed to inherently minimize thermal stress in the heat exchanger.

    Premix Modulating Burner Operation

    The premix burner controls automatically adjust the air and gas mixture to the correct proportions before it enters the burner. A symmetrical, 360° even-temperature heat output is achieved from the burner, providing clean combustion with low NOx emissions. Turndown is up to 5:1 with emissions of less than 20 ppm.

    Burner Gas Train

    Standard components meet the requirements of cULus, ASME CSD-1, XL-GAP and FM.

    • Low gas pressure manual reset

    • High gas pressure manual reset

    • CSD-1 test cocks

    • Manual test valve

    • Dual safety shutoff valve

    • Gas pressure regulator

    Gas train is factory piped and wired on the burner.

    Boiler Trim and ControlsBoiler trim is in accordance with cULus and ASME CSD-1.

    • High limit pressure control — manual reset

    • Operating limit pressure control• Combustion air proving switch• Primary LWCO and pump control• Manual reset ALWCO • ASME safety relief valve set (15 psig or 150 psig)

    Reliable Steam• Greater than 99% steam quality down to as low as 6 psig• Guaranteed up to 85% fuel to steam efficiencies

    ClearFire®-H Options

    Optimize Your Steam System

    • Blowdown and feedwater valve assemblies

    • Surface blow-off controls

    • Chemical feed tank

    • Packaged feedwater system

    • Feedwater economizer

    • High-pressure regulator

    • Lead-lag header pressure

    • Reusable air filter

    • Direct vent combustion provision for reduced make-up air requirement

    • Building EMS communication interface solutions

    • Pre-fabricated exhaust solutions

    Patented ALUFER Tubes

  • User-friendly Controls

    • Touch screen graphics

    • PID set point control (single boiler and lead lag)

    • Configurable lead lag control up to eight boilers

    • Comprehensive diagnostics/fault history

    • Combustion air/draft control interlock

    • Night setback

    • Hot standby

    • ModBus (RS485) Communications

    – multiple protocol gateway solutions available

    The Cleaver-Brooks Falcon steam controller is a proven boiler/burner management control that provides an intuitive operator interface featuring integrated burner sequencing, trending, flame safety, modulation, alarms, lockout and much more, ensuring your boiler system operates at peak efficiency, while providing necessary safety and reliability.

    The Cleaver-Brooks Falcon control with integrated lead/lag optimizes the boiler room’s operational efficiency while delivering precise steam load control to meet heating and process demands. The Cleaver-Brooks Falcon can communicate with your building’s Energy Management System (EMS), which helps maximize overall system efficiency.

    The ClearFire®-H is the ideal boiler for both heating and process steam applications. The Falcon lead/lag control is uniquely capable of optimizing the ClearFire-H’s combustion and thermal performance characteristics to sequence and modulate ClearFire-H boilers to maximize steam plant efficiency. The Cleaver-Brooks Falcon lead/lag control uses the common base load firing rate method to sequence and modulate a multiple-boiler system. This approach optimizes the boilers’ operating efficiency while minimizing energy-wasting short cycling. The elimination of short cycling minimizes purge and standby losses, while extending the life and reliability of your boiler system.

    Intelligent Integrated Controls

    Boilers

    5

  • Looking for a engineered steam solution? Cleaver-Brooks offers standard and complete steam boiler system skid mounted packages in gas and propane fuels. The package includes the steam boiler, feed system and blowdown separator with optional chemical feed system and water softener. This complete package saves you time installing the system as all that is required is a single-power, gas, steam and water connection.

    Features

    • Single-source responsibility

    • Plug and Play, reduced installation cost

    • Standard and customized skid solutions to meet your needs

    • Eliminate field piping and wiring errors

    The ECF ClearFire® economizer is a stainless steel coil tube arrangement using extended heating surface fins to maximize heat transfer. Flue gas from the boiler passes over the coiled tube, which conveys incoming feedwater. Feedwater preheated in this fashion reduces the need for a steam feedwater heater, resulting in efficiencies of up to 87% in non-condensing applications.

    Single Source Skid Package Solutions

    Maximize Efficiency to 87% with an Economizer

    Integral CFH Economizer

    External Economizer

    6

  • Notes:*For altitudes above 1,500 ft., contact local Cleaver-Brooks authorized representative for verification of boiler and blower motor size. **ASME ratings from 0 psig and at 212º - for safety relief valve sizing

    Boiler Horsepower 10 15 20 25 30 40 50 60

    Dimensions – inchesOverall Length (A) 86 86 87 87 91.5 104 110 110

    Overall Width (B) 43.5 43.5 47 47 56 56 60 60

    Width (BB) minus water column and blowdown 38 38 41.5 41.5 49 49 55 55

    Overall Height (C) 54 54 57 57 65.5 65.5 69 69

    Connections - inchesStack Nominal OD (D) 6 6 6 6 8 8 10 10

    Gas Connection (E) 1 1 1 1 1 1/4 1 1/4 1 1/2 1 1/2

    Feedwater (F) 1 1 1 1 1 1 1 1/4 1 1/4

    Bottom Blowdown (G) 1 1 1 1 1 1 1 1/4 1 1/4

    Steam Outlet (H) 15# ST. 4 4 4 4 4 6 6 6

    Steam Outlet (H) 150# ST. 1 1/2 1 1/2 2 2 2 2 3 3

    Surface Blowoff (I) 1 1 1 1 1 1 1 1

    Chemical Feed (J) 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2

    Overflow (K) 1 1 1 1 1 1 1 1

    Steam Boiler Weights in lbsNormal Water Weight - 15# 920 920 1,150 1,150 1,710 1,980 2,510 2,510

    Normal Water Weight - 150# 1,010 1,010 1,250 1,250 1,850 2,150 2,700 2,700

    Approx Shipping Weight 2,450 2,450 2,750 2,750 3,400 3,700 5,200 5,200

    Power Requirements (115VAC, 60 Hz, single phase)Blower Motor Size (Watts)* 335 335 335 335 335 750 1,200 1,200

    RatingsASME Rated Capacity - Steam (lbs-steam/hr from & at 212˚F) - Steam Safety Relief Valve Sizing**

    345 518 690 863 1,035 1,380 1,725 2,070

    ASME Rated Capacity - Steam (kg-steam/hr from & at 100˚C) - Steam Safety Relief Valve Sizing**

    156 235 313 391 469 626 782 939

    Rated Capacity - Steam (lbs-steam/hr at 6# operating pressre)

    338 507 676 845 1,014 1,352 1,690 2,028

    Rated Capacity - Steam (kg-steam/hr at 41.4 kPa) 153 230 307 383 460 613 767 920

    Fireside Heating Surface (sq.ft.) 122 122 191 191 310 381 573 573

    Turndown/Modulating Firing Range 4:1 4:1 4:1 4:1 4:1 5:1 5:1 5:1

    ClearFire®-H Boiler Dimensions and Ratings

    Boilers

  • Printed in the USA©2016 Cleaver-Brooks, Inc

    CB-808401/16Boiler system icons are copyrights of Cleaver-Brooks, Inc.

    Packaged Boiler Systems 221 Law Street • Thomasville, GA 31792 USA

    800-250-5883 • [email protected]

    Total Integration goes far beyond boilers.For more than 80 years, Cleaver-Brooks has built a reputation for

    innovation in the boiler solutions industry. We remain committed to

    introducing technology and products that enable a more energy-efficient

    and environmentally friendly generation of steam and hot water.

    When you come to us for a boiler solution, you can know that each

    element is created to the highest standards and all will work together

    seamlessly to give you a highly efficient and reliable solution for protecting

    your boiler system. To learn more, please call or visit us online.