Image Client Address Contact 20.58% THC Max 0.60% CBD Max Name Test Client ID 915 Matrix Sampling Test Complete 1/22/2016 Received Lab Sample ID Inspection Test Result Cannabinoids % by weight Δ9-THCa 21.39% 213.9 mg/g Δ9-THC 1.82% 18.2 mg/g Δ9-THCa 21.4% CBDa 0.11% 1.1 mg/g Δ9-THC 1.8% CBD 0.50% 5.0 mg/g CBDa 0.1% CBC 0.12% 1.2 mg/g CBD 0.5% CBN 0.33% 3.3 mg/g CBC 0.1% CBG 0.18% 1.8 mg/g CBN 0.3% Microbiology CFU/g CBG 0.2% 8,400 Conforming (<10^4 CFU/g)** Pesticides PPM Organochlorines ND Conforming (<0.1 PPM)** ND Conforming (<0.1 PPM)** Carbamates ND Conforming (<0.1 PPM)** Pyrethroids ND Conforming (<0.1 PPM)** Others Not Tested Not Tested (<0.1 PPM)** Page 1 of 2 Kenevir Research Laboratories 1290 Antelope Road White City, OR 97503 [email protected] www.kenevirresearch.com Taking the guesswork out of cannabis Tel: (541) 668-7444 Powered by Confident Cannabis Certificate of Analysis Client Information Green Source Gardens Wolf Creek, OR 97497 [email protected] (541) 866-2728 THC Max = (THCa x 0.877) + THC CBD Max = (CBDa x 0.877) + CBD Sample Information Blue Shiva Oregon Compliance Panel Plant, Flower - Cured, Outdoor Provided 1/14/2016 1601KR0026.0067 Micro: Clean sample with no visible signs of pests, chemicals, mold or mildew Macro: Bright green, dense, aromatic, trimmed tops Analytical Disposition Method Cannabinoid Profile Method: Swift, et al., 2013, modified Instrument: Shimadzu LC2030 Yeast & Mold Count AOAC Method 997.02 Petrifilm Method: CEN EN15662 w/ SPE Organophosphates Instruments: Agilent GC- MS/MS and LC-MS/MS Anthony Smith, Ph.D I hereby certify that the above information is authentic and accurate. The sample and batch (where applicable) has been handled and tested in full compliance with our ISO 17025-ready Quality System and FDA cGLP requirements. **Oregon HB3460, OAR 333-008 Executive Scientist Medical cannabis pesticide residue validation and analysis carried out in partnership with Synergistic Pesticide Laboratory, LLC (Portland, OR). TNC = too numerous to count. ND = not detected. AC-Result is above callibration range. This report shall not be reproduced, unless in its entirety, without written approval from Smith Scientific Industries, Inc., d.b.a. Kenevir Research Labs. This report is a Smith Scientific Industries, Inc. certification. The results relate only to the material or product analyzed. Test results are confidential unless otherwise noted. Void after 90 days from test end date. Cannabinoid content of batch material may vary depending on sampling error. Certificate of Analysis 1601KR0026.0067