Top Banner
COOLING ONLY [50Hz] 220V-240V, 380V-415V PLXSHK1503D Ceiling Concealed FDBR, FDMR Series PLXSHK1503D.indd 1 PLXSHK1503D.indd 1 2/6/2020 5:11 PM 2/6/2020 5:11 PM
8

Ceiling Concealed - daikin.com.hk

May 18, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ceiling Concealed - daikin.com.hk

i

COOLING ONLY [50Hz] 220V-240V, 380V-415V

PLXSHK1503D

Ceiling ConcealedFDBR, FDMR Series

PLXSHK1503D.indd 1PLXSHK1503D.indd 1 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 2: Ceiling Concealed - daikin.com.hk

1

Space Saving & PrestigiousFlexibility in System DesignThe unit comes with 4-speed motor as standard (for class 71 and above), thus providing wide choices of external static range for designing the duct system.

Excellent Air DistributionThe conditioned air can be distribut-ed evenly to every corner of the room through ducting. This helps to create a pleasant environment and maintaining comfort. Furthermore, multiple areas can be conditioned simultaneously by using just one indoor unit.

1

Complies with Hong Kong Fire RegulationThe parts in the indoor unit are all designed based on the Hong Kong Fire Regulation, for example, metal fan motor, insulation material, metal drain pan, etc. which will be suit-able for the usage of public area in Hong Kong.

PLXSHK1503D.indd 1PLXSHK1503D.indd 1 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 3: Ceiling Concealed - daikin.com.hk

2

Serviceability FriendlyThe unit’s design enables access to control box and fi lters from the side panel for easy serviceability.

Double Drain Pan ProtectionThe primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan built into the standard unit offers extra protection against possible water leaking problems.

fi lter cover

primary drain pan polys-terene (PS) with High Impact Polys-terene (HIPS) coversecondary drain pan

with insulation

Self Diagnosis FeatureThe microprocessor provides the possibility to detect and diagnose any faults that occur in the system. Faults are displayed as error codes in the wired controller. This eases trou-bleshooting process.

Wired Remote Controller as StandardCompact and user friendly.

BRC51A

Auto Random Restart with Last-State-MemoryIn the event of a sudden power failure during operation, unit restarts automatically in 64 different recovery timing patterns (within 180 seconds to 244 seconds) and the unit will op-erate based on the previous setting (operat-ing mode, temperature setting and fan speed). This ensures that air conditioners in the same building resume randomly instead of all units resuming at the same time, preventing power surge after a blackout.

Sleep ModePressing the Sleep button activates the Sleep Mode. This function prevents excessive cool-ing for a pleasant sleep.

Time

Cooling

30mins

Sleep mode turns on

+

Set temp. before Sleep mode

begins to operate

++

30mins

60mins

Cooling operation: 1) After 30 minutes, room temperature is raised by 0.5˚C.2) After 60 minutes, room temperature is raised by 0.5˚C.3) After 120 minutes, room temperature is raised by 1˚C.

Time

Heating(heatpump models)

30mins

Sleep mode turns on

Set temp. before Sleep mode

begins to operate

-

30mins

60mins

-

-

Heating operation: 1) After 30 minutes, room temperature is reduced by 1˚C.2) After 60 minutes, room temperature is reduced by 1˚C.3) After 120 minutes, room temperature is reduced by 1˚C.

EE2 2 PROMPROME2 PROM

RestartStopOperation

Power failure Power returns

Settings stored before power failure

PLXSHK1503D.indd 2PLXSHK1503D.indd 2 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 4: Ceiling Concealed - daikin.com.hk

3

> Excellent air distribution > Flexibility in system design> Auto random restart with last-state-memory > Sleep mode> Double protection drainage system > Self diagnosis feature> Wired handset BRC51A62 supplied as standard

Ceiling Concealed C Series (50Hz)

FDBR25/35/50/60AXV1HFDMR71/100/125/140/160AXV1H

RN25/35BV19

GOLD

RR71BV19RR71BY19

RR100/125/140/160BY19

RN50/60BV19

Specifi cation for ceiling concealed - Cooling only (R410A)Indoor model name FDBR25AXV1H FDBR35AXV1H FDBR50AXV1H FDBR60AXV1H FDMR71AXV1HOutdoor model name RN25BV19 RN35BV19 RN50BV19 RN60BV19 RR71BV19Nominal cooling capacity Btu/hr 9500 12500 18000 20800 28000

W 2780 3660 5280 6100 8210Nominal total input power W 961 1297 1760 2080 3000

Nominal running current A 4.30 5.70 7.75 9.24 13.80

Power supply V/Ph/Hz 220-240/1/50Nominal EER W/W 2.89 2.82 3.00 2.93 2.74Refrigerant type - R410A

Indoo

r

Control (air discharge) - DuctedControl (Operation) - BRC51A62 wired controllerAirfl ow (SH/H/M/L) CFM -/250/220/190 -/410/360/320 -/570/540/450 -/690/640/520 760/710/650/

600External Static Pressure (SH/H/M/L) Pa -/29/20/10 -/29/20/10 -/29/20/10 -/29/20/10 70/61/51/44Sound pressure level (SH/H/M/L) dBA -/36/33/30 -/31/24/21 -/41/40/36 -/42/41/37 42/41/38/34Unit dimensions (HxWxD) mm 261x797x411 261x905x411 261x1065x411 261x1200x411 285x1001x600Net weight kg 18 22 24 26 40

Outdo

or

Airfl ow (SH/H/M/L) CFM 927 827 1300 1460 1450Sound pressure level (SH/H/M/L) dBA 46 48 52 52 58Unit dimensions (HxWxD) mm 543x700x250 651x855x328 753x855x328Net weight kg 34 34 43 47 57

Maximum Piping Length m 12 12 30 30 45Maximum Piping Elevation m 5 5 15 15 25

PLXSHK1503D.indd 3PLXSHK1503D.indd 3 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 5: Ceiling Concealed - daikin.com.hk

4

Ceiling Concealed C Series (50Hz)

Specifi cation for ceiling concealed - Cooling only (R410A)Indoor model name FDMR71AXV1H FDMR100AXV1H FDMR125AXV1H FDMR140AXV1H FDMR160AXV1HOutdoor model name RR71BY19 RR100BY19 RR125BY19 RR140BY19 RR160BY19Nominal cooling capacity Btu/hr 28000 36000 42000 46000 55000

W 8210 10550 12310 13480 16120Nominal total input power W 2955 3800 4500 5100 5758

Nominal running current A 5.30 6.20 7.13 8.68 9.40

Power supply V/Ph/Hz 380-415/3/50Nominal EER W/W 2.78 2.78 2.74 2.64 2.80Refrigerant type - R410A

Indoo

r

Control (air discharge) - DuctedControl (Operation) - BRC51A62 wired controllerAirfl ow (SH/H/M/L) CFM 760/710/650/

6001280/11601020/920 1280/11601020/920 1430/1300/1200/1150 1720/1530/1340/1200

External Static Pressure (SH/H/M/L) Pa 70/61/51/44 70/57/33/36 70/57/33/36 70/58/49/45 70/55/42/34Sound pressure level (SH/H/M/L) dBA 42/41/38/34 52/49/47/45 52/49/47/45 50/48/46/44 51/49/47/45Unit dimensions (HxWxD) mm 285x1001x600 305x1306x638 305x1306x638 378x1369x541 378x1569x541Net weight kg 40 49 49 50 56

Outdo

or

Airfl ow (SH/H/M/L) CFM 1712 3000 3400 4000 4600Sound pressure level (SH/H/M/L) dBA 58 58 58 60 65Unit dimensions (HxWxD) mm 753x855x328 852x1030x428Net weight kg 56 71 95 98 105

Maximum Piping Length m 50 50 50 50 35Maximum Piping Elevation m 30 30 30 30 15

> Excellent air distribution > Flexibility in system design> Auto random restart with last-state-memory > Sleep mode> Double protection drainage system > Self diagnosis feature> Wired handset BRC51A62 supplied as standard

FDBR25/35/50/60AXV1HFDMR71/100/125/140/160AXV1H

RN25/35BV19

GOLD

RR71BV19RR71BY19

RR100/125/140/160BY19

RN50/60BV19

PLXSHK1503D.indd 4PLXSHK1503D.indd 4 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 6: Ceiling Concealed - daikin.com.hk

5

Selectable Fan Speed - Different fan speed is available for comfort selection

GOLD

Washable Saranet Filter - Removal of air-borne dust particles through saranet fi lter en-sures cleaner air supply

Dry Mode - Keeping the room dehumidifi ed, while maintaining room temperature

Sleep Mode

Anti Corrosion Hydrophilic Gold Fin

Comes with wired controller

Power from outdoor

Comfort

Airfl ow

Indoor Air Quality

Condenser fi n type

Controller

Power supply

BRC51A Wired Remote Controller (LCD)

BRC51A62 - Cooling only

Features:• Cool/Fan/Dry mode• Auto/High/Med/Low fan speed• Temperature operate in ºC and ºF• Sleep function• Air swing function• Real time clock and day display• 7-days programmable timer• Error indicator• Keylock and fan-lock features• Batteries backup and retain setting during power failure• Last state memory (memory backup setting from main board)• Delay timer (1 or 2 hours)• Interaction with wireless handset (BRC52A62)

BRC52A Wireless Remote Controller (optional)

BRC52A62 - Cooling only

Features:• “Glow in the dark” on/off button• Cool/Fan/Dry mode• Auto/High/Med/Low fan speed• Sleep function• Air swing function• Real time clock• On/off timer setting in real time

Standard Features

PLXSHK1503D.indd 5PLXSHK1503D.indd 5 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 7: Ceiling Concealed - daikin.com.hk

6

Notes

PLXSHK1503D.indd 6PLXSHK1503D.indd 6 2/6/2020 5:11 PM2/6/2020 5:11 PM

Page 8: Ceiling Concealed - daikin.com.hk

7

Specifi cations, designs and other content appearing in this brochure are current as of March 2017 but subject to change without notice. © All rights reserved

PLXSHK1503D.indd 7PLXSHK1503D.indd 7 2/6/2020 5:11 PM2/6/2020 5:11 PM