McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW 015, 019 Vintage C Last Manufactured: 1999 Replacement Parts List No. 057104800 Revision N 01/2016 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
21

McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

Mar 06, 2018

Download

Documents

buithuan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

McQuay

Concealed Ceiling Water Source Heat Pump

CCH, CCG, CCW

015, 019Vintage C

Last Manufactured: 1999

Replacement Parts List No. 057104800Revision N 01/2016

To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com

Page 2: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 2

***NOTICE***For CCH, CCW, CCG units, the serial number Revision Level is necessary to

properly identify refrigeration circuit components

Contents

Parts List Revision History..............................................................................................3, 4

Nomenclature Serial Number ...............................................................................................................5 Model Number - Until February, 1999 ............................................................................5 Model Number - February, 1999 and later .....................................................................5 Model Number- Complete ..............................................................................................6

Fan Assembly .....................................................................................................................7

Refrigeration Circuit Diagram .........................................................................................................................8 Components for Serial Number Revision Level 00-04 .............................................9, 10 Components for Serial Number Revision Level 05, 06 ..........................................11, 12 Components for Serial Number Revision Level 07 ................................................13, 14

Control Box .................................................................................................................15, 16

Field Installed Accessories ........................................................................................ 17- 20

Critical Parts List..........................................................................................................CPL1

Page 3: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 3

A 10-1-96 Updated RPL layout to be consistant w/ OnLine format. B 9-15-97 Added "L" Control note to Cover, Added "L" Control Code to p.4, Added Compressor Overloads for size 015 and Sleeve for Rev. 06 for "L" Control to p.13, Corrected Rev. Valve P/Ns and added Rev. Valve Solenoid for "L" Control to p.14, Added Rev. Valve Solenoid to p.16, Corrected Mark IV/AC Ckt. Brd. P/N and added Temp. Sensor P/Ns to p.19, Corrected Drain Pan P/N on p.22. C 9-23-97 Converted all part numbers to Mitrol format; Removed "L" Control note from Cover; Updated Serial Number Nomenclature, p 4; Updated Field Thermostats and Subbases, pp 5-6; Updated Controls Section, pp 19-20. D 12-8-98 Page 13 - Corrected Compressor information for size 015, 230/50/1. E 9/99 Page 4- Corrected Model Number Nomenclature, Added new Serial Number Nomenclature; Page 5- Added new page for Complete Model Nomenclature, which resulted in the re-numbering of all subsequent pages. Page 7- Added Locking Cover with Override Button; Page 9- Corrected part number for 3-Unit Control Panel; Page 11- Added Condenser and Compressor Mounting details; Page 13- Changed Coil descriptions, Removed Notes and incorporated them into text; Page 14- Added Capacitor Bracket, Fusible Plug PN changed, Added Compressor Gasket, Nut, Spring, and Terminal Cover for size 019, Capacitor for 015, 265V PN changed, Capacitor for 019, 60 Hz. PN changed; Page 15- Coil descriptions changed, Ref. # 4/Capillary PN's changed, Added MicroTech "L" Solenoid, Added Condenser Water & Liquid Tubes and Fittings; Page 17- Changed Coil descriptions, Added "L" Solenoid, Condenser Water & Liquid Tubes & Fittings; Page 19- Ref. # 17 PN changed; Page 20- Removed CB Aux. Module (not used on 015/019), Added new "L" controller -02, Stand Off PNs changed for EMCP, Mark IV, MicroTech "C", Added ELUPC Terminal Block, MicroTech "C" and "L" Compressor Contactor for size 019 PN changed, Removed Terminal Board references for 019 only, Added "no longer used" note to Circuit Breakers, Corrected quantity columns that incorrectly indicated 230/50 usages for MicroTech, Amended note "#", Added Note 5; Page 21- Removed note indicators for Transformers; Page 23- Ref. # 50 Base Pan used after Rev Level 05 PN changed, Added Caged Nut PN, Added Evap Coil Blockoff, Ref. # 56 PN changed, Added Pleated Filter PN, Hanger Bracket Kit PN changed. F 8/00 Page 13-Ref. #2, p/n 060601702 had incorrect description of Copper. Part number 060601801 had incorrect descripton of Cupro-Nickel. G 8/01 Page 9-Control Relay for Motorized Valve pn was corrected from 059004354 to 859004345. H 7/02 Page 13 - Ref. #2, p/n 060601702 had incorrect description of Copper, p/n 060601801 had incorrect descripton of Cupro-Nickel. (This update was to be Rev. F, but for some reason it didn't save). I 6/03 Added second pg. to Rev. History. Added new art. Renumbered footnotes (all subsequent pgs. renumbered). Pages 7 thru 10- Reformatted to new standards. Removed Mark IV T-Stats for 2 compressor units (do not apply). Added details for RAP, MUC panels. Reformatting removed one page. Page 12- Ref. # 1 added manufacturer's number for compressors and overloads. Page 13- Ref. # 8 description corrected so not in all caps. Page 14- Changed headline to define compressor type by unit size. Added manufacturer's number for compressors. Page 15- Ref. # 11 p/n changed to 802017216. Page 16- Ref. # 1 added manufacturer's number for compressors, and added compressor parts. Page 21- 50 Hz. Terminal Block qty. changed to 3. Page 23- Corrected spelling for Evap blockoff. Ref. # 50 p/n for Rev. 05 Base Pan changed to 057576702. J 11/08 Page 6 - Code #2 change 7,000 BTU to 15,000 BTU and 9,000 BTU to 19,000 BTU. K 4/09 Page 20- Added DC to Mark IV Board p/n 056792401. Added Mark IV Board AC p/n 056792402 and added notes to footnote #7 and #11. L 01/10 Page 20- Change footnote #11 for Mark IV control units p/n 056792404 to 056792402. M 2/15 Rebrand to Daikin. Deleted compressor vendor numbers and updated capacitors. Page 7 Deleted sheetmetal and add footnote for cabinet/chassis components. Page 21- Add drain pan, filters and condenstate overflow components. Pages 22-23 Deleted cabinet sheetmetal.

Parts List Revision History

Revision Date Description

Continued on next page

Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

Page 4: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 4

Parts List Revision HistoryContinued

Revision Date Description

N 01/16 Rebrand Daikin. Numerous changes. Delete sheet metal. Reorganize Contents and RPL. Page 7- Add sheet metal note for chassis & cabinet components to drawing & components. Add footnote 1. Page 15- Change air & water sensor p/n 4EZS9158 to 106110801. CPL1- Add critical parts list.

Page 5: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 5

CCH 015C E G S

Unit Size / Vintage

CCH = Ceiling Concealed Water Source Heat PumpCCG = Ceiling Concealed Cooling Only CCW = Ceiling Concealed Extended Range Heat Pump

015C = 15,000 Nominal Cooling Btuh019C = 19,000 Nominal Cooling Btuh

Model Number- Nameplate

Control SystemE = Electromechanical Printed Circuit BoardM = Mark IV /AC Control SystemC = MicroTech 120 Unit Controller L = MicroTech 520 LonWorks Unit Controller

Discharge Air ArrangementS = Straight DischargeE = End Discharge

VoltageJ = 230/50/1G = 208-230/60/1N = 265/60/1

Model Type

7 6 A 00000 00

Nomenclature

Plant Identification Number7 = Auburn

Serial Number

Month Manufactured A = January B = February C = March D = April E = May F = June

Engineering Revision

Year ManufacturedY= 1993Z= 19945= 19956 = 19967 = 19978 = 19989 = 1999

Serial Number- Until February, 1999

G = JulyH = August I = September J = OctoberK = NovemberL = December

Serial Number- February, 1999 and later

AUB U 08 05 00386Plant Identification

AUB = Auburn

Year of Manufacture10= 201011= 2011

etc.

U= Unit

Serial Number (build sequence)

Week of Manufacture

Page 6: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 6

NomenclatureModel Number- Complete

1. Model TypeCCH = Ceiling Concealed WSHPCCW = Ceiling Concealed WSHP, Extended Range CCG = Cooling Only

2. Unit Size and Vintage015C = 15,000 BTU Cooling019C = 19,000 BTU Cooling

3. Control SystemE= Electromechanical ControlM= Mark IV ControlC= Microtech 120 ControlL= MicroTech 520 LonWorks Control

4. Unit VoltageG= 208/230/60/1N= 265/60/1J= 230/50/1

5. Discharge Air ArrangementS= StandardE= End

6. Construction Type1= StandardE= Extra Quiet

7. Coaxial Heat Exchanger1= Copper Inner Tube/Steel Outer TubeC= Cupro-Nickel Inner Tube/Steel Outer Tube

8. Water Regulating Valve*W= Water Regulating ValveY= None

9. Starting ControlR= Random Start Relay(only used with Electromechanical control)

10. Overflow ProtectionF= Float Switch(only used with Electromechanical control)

11. ControlsSDR= Shutdown RelayElectromechanical Control OnlyNSR= Night Setback RelayElectromechanical Control OnlyNSD= Night Setback and Demand Control RelayElectromechanical Control OnlySDN= Shutdown and Night Setback RelayElectromechanical Control OnlyMTR= Timed Output RelayMicroTech or MircoTech 520 LonWorks onlyMTV= Motorized ValveMicroTech or MircoTech 520 LonWorks onlyMBS= Boilerless System RelayMicroTech or MircoTech 520 LonWorks onlyMFD= Fresh Air DamperMicroTech or MircoTech 520 LonWorks only

12. Auxiliary RelayY= NoneA= Auxiliary Relay*

14. Filter*A= ThrowawayB= Pleated

15. Paint*Y= None

16. Finned Tube Coil*1= Copper Tube/Aluminum Coil

17. Fan Housing/Wheel and Motor Assembly*D= Direct Drive 2 speed

18. Logo and Nameplate*M= McQuay (may also have been labeled SnyderGeneral)

19. Construction Code*Y= NoneC= Chicago

20. Agency Listing*W= ETL, CSA, MEA, ARIY= None

21. WarrantyA= StandardQ= Extended 4-year Compressor Warranty (5 year total)S= Extended 4-year Refrigerant Circuit Warranty (5 year total)

*Codes not listed in price book. These are standard items that will only change in the case of a special, which will be denoted with an "X" in the appropriate code.

CCH 015C L N S E C W Y Y MTV Y A Y 1 D M Y W Q Code: 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21

Page 7: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 7

Fan AssemblyDiagram

15

19 20

18

16

Cabinet/Chassis components

015 019

Ref. Description Part No. Number 15 Motor, 1/8 HP 060704501 1 1 1 1 Motor, 1/8 HP 060704502 1 1 Motor, 1/8 HP 060704503 1 1

N/S Kit, Motor Mount 062200601 1 1 1 1 1 1 1 1

16 Capacitor, Motor 3MFD 370VAC 067291501 1 1 1 1 1 1 1 1 17 Bracket, Capacitor 850010570 1 1 1 1 1 1 1 1

18 Blower Housing 060699603 1 1 1 1 1 1 1 1 19 Inlet Ring 060828601 1 1 1 1 1 1 1 1 20 Blower Wheel 060704801 1 1 1 1 1 1 1 1

N/S Cabinet/Chassis components 1 1 1 1 1 1 1 1 1N/S = Not shown on diagram.1 Contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components.

208/

60/1

230/

60/1

265/

60/1

230/

50/1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

Page 8: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 8

Refrigeration CircuitDiagram

Condenser

Reversing Valve &

Solenoid

High PressureSwitch

Compressor

Low Temp.T-Stat

Accumulator

Evaporator Coil

Strainer

Condenser

Condenser Detail Compressor Mounting Detail

Compressor

Mounting Stud

Mounting Plate

1

8

2

6 7

11

1012

5

4

3

21

20

2122

58

57

61

To Water Regulating Valve

(optional)

Page 9: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 9

015 019

Ref. Description Part No. Number 1 Compressor, 15000 BTUH 060626701 1 1 Compressor, 15000 BTUH 060626702 1 Compressor, 15000 BTUH 060603002 1 Compressor, 19000 BTUH 060603001 1 1 Compressor, 19000 BTUH 060603002 1 Compressor, 19000 BTUH 060603703 1 N/S Crankcase Heater- CCW 061452306 1 1 Crankcase Heater- CCW 061452311 1

N/S Overload, Compressor 060943901 1 1 Overload, Compressor 060943902 1

N/S Capacitor, 25 MFD, 370V 067291512 1 1 1 1 1 N/S Capacitor, 25 MFD, 370V 802007855 1 1 N/S Capacitor, 30 MFD, 370V 802007848 1 N/S Nut 802012035 3 3 3 4 4 4 4 4

N/S Spacer 060687801 3 3 3 4 4 4 4 4 N/S Spacer 060687901 3 3 3 4 4 4 4 4

N/S Spring 060688001 3 3 3 4 4 4 4 4 N/S Sleeve 802003425 3 3 3 4 4 4 4 4 N/S Plug, Threaded 1/2-13 802028117 1 1 1 1 1 1 1 1 N/S Plug, Fusible 802025014 1 1 1 1 1 1 1 1

N/S Valve, Water Regulating- CCH, CCG 802026197 1 1 1 1 1 1 1 1 N/S Valve, Water Regulating- CCW 802026158 1 1 1 1 1 1 1 1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

N/S = Not shown on diagram

Refrigeration CircuitComponents for Serial Number Revision Level 00-04

Page 10: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 10

Ref. Description Part 015 019 No. Number 2 Condenser Coil- Copper 060601701 1 Condenser Coil- Cupro-Nickel 060601702 1 Condenser Coil- Copper 060601801 1 Condenser Coil- Cupro Nickel 060601802 1 3 Evaporator Coil 056916101 1 Evaporator Coil 056916201 1

4 Capillary 802001009 2 Capillary 802001158 2 5 Strainer 802001068 1 Strainer 060628801 1 6 Reversing Valve 066533401 1 1 7 Reversing Valve Solenoid- CCH, CCW 066541901 1 1

8 Switch- High Pressure 802005813 1 1 10 Thermostat, Low Temp. Cut-Out- CCH, CCG 066540601 1 1 Thermostat, Low Temp. Cut-Out- CCW 066540603 1 1

11 Clip, Thermostat 802017214 1 1

12 Accumulator- CCW 060721801 1 1 N/S Valve, Schrader 802026161 3 3

Refrigeration CircuitComponents for Serial Number Revision Level 00-04, Cont'd.

N/S = Not shown on diagram

Page 11: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 11

015 019

Ref. Description Part No. Number 1 Compressor 061043401 1 1 Compressor 061043402 1 1 Compressor 067291402 1 1 Compressor 067291401 1 1 N/S Overload, Compressor 057458801 1 1 Overload, Compressor 067293301 1 1 1 Overload, Compressor 060993105 1 1 Overload, Compressor 060993106 1 N/S Capacitor, 25 MFD, 370V 067291512 1 1 1 N/S Capacitor, 25 MFD, 370V 067291517 1 N/S Capacitor, 35 MFD, 370V 067291515 1 1 1 N/S Capacitor, 50 MFD, 370V 067291519 1 N/S Capacitor Support Bracket 060675201 1 1 1 1 1 1 1 1 58 Nut 032333303 3 3 3 3 3 3 3 3 57 Sleeve 6 060623403 3 3 3 3 3 3 3 3 61 Grommet 060623301 3 3 3 3 3 3 3 3 N/S Washer 040500307 3 3 3 3 3 3 3 3

N/S Compressor Gasket 066536201 1 1 1 1 N/S Compressor Gasket 066536601 1 1 1 1 N/S Compressor Nut 066536501 1 1 1 1 N/S Compressor Spring 066536301 1 1 1 1 N/S Compressor Terminal Cover 067280501 1 1 1 1 N/S Plug, Threaded 1/2-13 802008117 1 1 1 1 1 1 1 1 N/S Plug, Fusible 850008345 1 1 1 1 1 1 1 1 N/S Valve, Water Regulating- CCH, CCG 802026197 1 1 1 1 1 1 1 1 N/S Valve, Water Regulating- CCW 802026158 1 1 1 1 1 1 1 1

Refrigeration CircuitComponents for Serial Number Revision Level 05, 06

Tecumseh Compressors- 015Panasonic Compressors- 019

208/

60/1

230/

60/1

265/

60/1

230/

50/1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

N/S= Not Shown on diagram.6 On units with Serial Number Revision 06, use Sleeve p/n 060623401.

Page 12: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 12

Ref. Description Part 015 019 No. Number 2 Condenser Coil- Copper 067789501 1 Condenser Coil- Cupro Nickel 067789502 1 Condenser Coil- Copper 073399801 1 Condenser Coil- Cupro Nickel 073399802 1 3 Evaporator Coil 056916101 1 Evaporator Coil 056916201 1

4 Capillary 057465001 2 Capillary 057020602 2 5 Strainer 060628801 1 1 6 Reversing Valve 066533401 1 1 7 Reversing Valve Solenoid- CCH, CCW EMCP, Mark IV, MicroTech 120 (C03= C,E,M) 066541901 1 1 MicroTech 520 LonWorks (C03= L) 067010001 1 1

8 High Pressure Switch 802005813 1 1 10 Thermostat, Low Temp. Cut- Out- CCH, CCG 066540601 1 1 Thermostat, Low Temp. Cut- Out- CCW 066540603 1 1

11 Clip, Thermostat 802017216 1 1

12 Accumulator- CCW 060721701 1 Accumulator- CCW 060721801 1

20 Tube- Water Inlet/Outlet 107481901 2 2

21 Adapter, Fitting 041116213 2 2

22 Tube- Liquid 057463201 1 Tube- Liquid 057020501 1 N/S Valve, Schrader 802026161 3 3N/S = Not shown on diagram.

Refrigeration CircuitComponents for Serial Number Revision Level 05, 06- Continued

Tecumseh Compressors- 015Panasonic Compressors- 019

Page 13: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 13

015

Ref. Description Part No. Number 1 Compressor 073320702 1 1 Compressor 073320701 1 1

N/S Overload, Compressor 067299401 1 1 Overload, Compressor 057458901 1 Overload, Compressor 067293201 1

N/S Capacitor, 35 MFD, 370V 067291516 1 1 Capacitor, 35 MFD, 370V 067291515 1 Capacitor, 50 MFD, 370V 067291519 1 N/S Support, Capacitor 060675201 1 1 1 1 58 Nut 032333303 3 3 3 3

57 Sleeve 060623401 3 3 3 3

61 Grommet 060623301 3 3 3 3

N/S Washer 040500307 3 3 3 3

N/S Gasket- Compressor 066536601 1 1 1 1 N/S Gasket- Compressor 066536201 1 1 1 1

N/S Nut- Compressor 066536501 1 1 1 1

N/S Spring- Compressor 066536301 1 1 1 1

N/S Terminal- Compressor 067280501 1 1 1 1 N/S Plug, Threaded 1/2-13 802008117 1 1 1 1

N/S Plug, Fusible 850008345 1 1 1 1 N/S Valve, Water Regulating- CCH, CCG 802026197 1 1 1 1 Valve, Water Regulating- CCW 802026158 1 1 1 1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

N/S = Not shown on diagram.

Refrigeration CircuitComponents for Serial Number Revision Level 07

Panasonic Compressors- Size 015 Only

Page 14: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 14

Ref. Description Part 015 No. Number 2 Condenser Coil- Copper 067789501 1 Condenser Coil- Cupro Nickel 067789502 1

3 Evaporator Coil 056916101 1

4 Capillary 057465001 2 5 Strainer 060628801 1 6 Reversing Valve 066533401 1 7 Solenoid, Reversing Valve CCH,CCW EMCP, Mark IV, MicroTech 120 (C03= C,E,M) 066541901 1 MicroTech 520 LonWorks (C03= L) 067010001 1

8 High Pressure Switch 802005813 1 10 Thermostat, Low Temp. Cut Out CCH, CCG 066540601 1 Thermostat, Low Temp. Cut Out CCW 066540603 1

11 Clip, Thermostat 802017216 1

12 Accumulator- CCW 060721701 1 N/S Valve, Schrader 802026161 3

20 Tube- Water Inlet/Outlet 107481901 2

21 Fitting, Adapter 041116213 2

22 Tube- Liquid 057463201 1

N/S = Not shown on diagram.

Refrigeration CircuitComponents for Serial Number Revision Level 07, Cont'd.

Panasonic Compressors- Size 015 Only

Page 15: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 15

015 019

Description Part Number Circuit Board, Mark IV/DC 11 056792401 7 1 1 1 1 1 1 1 1 Circuit Board, Mark IV/AC 11 056792402 7 1 1 1 1 1 1 1 1 Circuit Board, Electromechanical 12 60679202K 1 1 1 1 1 1 1 1 Circuit Board, MicroTech 120 9 060959401 8 1 1 1 1 1 1 Circuit Board, MicroTech 520 LonWorks 10 until 12/97 073312501 8 1 1 1 1 1 1 Circuit Board, MicroTech 520 LonWorks 10 1/98 & later 073312502 1 1 1 1 1 1 Circuit Board, Lo Volt- 7 Position 10 073315201 1 1 1 1 1 1

Air and Water Temperature Sensor 9 until 12/99 4EZS9158 2 2 2 2 2 2 Air and Water Temperature Sensor 9 12/99 & later 106110801 2 2 2 2 2 2 Air Temperature Sensor 10 073305601 1 1 1 1 1 1 Water Temperature Sensor 10 073305701 1 1 1 1 1 1 Sensor, Clamp 9 802017214 2 2 2 2 2 2

Block, Terminal 9 3 Pole 049759001 1 1 1 1 1 1 Block, Terminal 9 4 Pole 049759002 1 1 1 1 1 1 Block, Terminal 9 5 Pole 049759003 1 1 1 1 1 1 Block, Terminal 10 ELUPC 061365602 1 1 1 1 1 1

Stand Off 11, 13, 15 802028115 5 5 5 5 5 5 5 5 Stand Off 12, 13, 15 802028115 4 4 4 4 4 4 4 4 Stand Off 9, 10, 15 802028115 1 1 1 1 1 1 1 1 Nut, Nylon 11, 15 802012415 5 5 5 5 5 5 5 5 Nut, Nylon 12, 15 802012415 4 4 4 4 4 4 4 4 Nut, Nylon 9, 10, 15 802012415 1 1 1 1 1 1 1 1 Contactor, Compressor 11, 12 073322401 1 1 1 1 Contactor, Compressor 11, 12 802005655 1 Contactor, Compressor 11, 12 073322301 1 1 Contactor, Compressor 11, 12 073322201 1 Contactor, Compressor 9, 10 047356506 1 1 1 1 Contactor, Compressor 9, 10, 14 073300101 1 1 1 1 Relay, Fan 047356506 1 1 1 1 1 1 Relay, Fan 803005132 1 1 Board, Terminal 9, 10 802007090 1 1 1 1 1 1 Circuit Breaker (no longer used as of 1/99) 803007113 1 1 1 1 1 1 1 17 When replacing reversing valve and/or coil refer to Service Bulletin WS-SB-20070423.8 Units with Serial Revision level 07 or below use p/n 060959401. Units with serial revision level 08 and above use p/n 073312501 (02).9 MicroTech 120 Control units only. (C03 = C).10 MicroTech 520 LonWorks Control units only. (C03 = L). 11 Units with Serial Revision level 03 or below used p/n 060638806 (N/A use 056792401). Units with Serial Revision level 04 and above use p/n 056792401. Mark IV Control units (C03 = M).12 Electromechanical Control units only. (C03 = E).13 Used after 8/96.14 On units built before 4/98 the contactor was p/n 803005223 and the 019 also used a Terminal Board. p/n 802007090. The 073300101 Relay replaces both parts.15 Prior to 6/95, the PC Board used Stand Off p/n 802028130 and the Nylon Nut was used to attach it. After this date the new stand off (802028115) replaced both parts.

Control BoxComponents

208/

60/1

230/

60/1

265/

60/1

230/

50/1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

Page 16: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 16

015 019

Description Part Number Relay, Random Start 12, 16 802005496 1 1 1 1 1 1 1 1 Relay, Shutdown 12, 17 061019403 1 1 1 1 1 1 1 1 Relay, Night Setback 12, 18 802005728 1 1 1 1 1 1 1 1 Relay, Demand Control 12, 19 802007881 1 1 1 1 1 1 1 1 Relay, Auxiliary 20 803005073 1 1 1 1 1 1 1 1

Relay, Timed Output 9 802005206 1 1 1 1 1 1 Relay, Boilerless System 9 802005206 1 1 1 1 1 1 Relay, Fresh Air Damper 9 802005206 1 1 1 1 1 1 Relay, Motorized Valve 9 802005206 1 1 1 1 1 1

Relay, Timed Output 10 061019403 1 1 1 1 1 1 Relay, Boilerless System 10 061019403 1 1 1 1 1 1 Relay, Fresh Air Damper 10 061019403 1 1 1 1 1 1 Relay, Motorized Valve 10 061019403 1 1 1 1 1 1

Mount, Terminal Block 061131001 3 3

Block, Terminal 802007432 3 3 End, Terminal Block 802007431 1 1 Lug, Terminal 802007744 1 1

Transformer- Control 060614101 1 1 1 1 1 1 Transformer- Control 060630701 1 1 Transformer 9 24 Volt AC 060949301 1 1 1 1 1 1 1 1 Switch, Condensate Overflow 12 803005260 1 1 1 1 1 1 1 1 Wire, Condensate Overflow 21 056794401 1 1 1 1 1 1 1 1

Miscellaneous Components Drain Pan 060637902 1 1 1 1 1 1 1 1 Hanger Bracket Kit 060676301 1 1 1 1 1 1 1 1 9 MicroTech 120 Control units only. (C03 = C).10 MicroTech 520 LonWorks Control units only. (C03 = L).12 Electromechanical Control units only. (C03 = E).16 Only on units with Random Start Relay Option.17 Only on units with Shutdown Relay Option.18 Only on units with Night Setback Option.19 Only on units with Demand Control Option.20 Only on units with Auxiliary Relay Option & without MicroTech Control. 21 Used only on MicroTech 120 and Mark IV controls.

Control BoxComponents

208/

60/1

230/

60/1

265/

60/1

230/

50/1

208/

60/1

230/

60/1

265/

60/1

230/

50/1

Page 17: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 17

Field Installed AccessoriesThermostats for Electromechanical Control Units

Description Thermostat Subbase Standard Manual Changeover Thermostat & Subbase. Honeywell T834C with no LED. Mounts vertically. 073319501 N/A System "Heat-Off-Cool" switch and fan "On-Auto" switch. (includes subbase) Standard Automatic Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319701 System "Off-Auto" switch and fan "On-Auto" switch. Deluxe Auto. Changeover T-stat & Subbase w/ Night Setback. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Req. factory installed NSB relay (Code 11=NSR,NSD or SDN) or 073318801 073320001 Field installed NSB or NSB/demand control relay. Night setback bulb set 8o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Programmable Electronic Thermostat & Subbase. 0671143011 N/A Honeywell Chronotherm III (2 Stage Heat, 2 Stage Cool). N/A= Not Applicable.1 Use this thermostat to eliminate "whooshing" sound during heating cycle.

Thermostats for Mark IV/AC Control Units

Description Thermostat Subbase Standard Manual Changeover Thermostat & Subbase. Honeywell T834C with no LED. Mounts vertically. 073319501 N/A System "Heat-Off-Cool" switch and fan "On-Auto" switch. (includes subbase) Standard Automatic Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319701 System "Off-Auto" switch and fan "On-Auto" switch. Std. Manual & Auto. Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319801 System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Deluxe Auto. Changeover T-stat & Subbase w/Night Setback. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Req. factory installed NSB relay (Code 11=NSR,NSD or SDN) or 073318801 073320001 Field installed NSB or NSB/demand control relay. Night setback bulb set 8o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Standard Auto. Changeover Thermostat & Subbase. For Operating Two Units. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319101 073319601 System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Programmable Electronic Thermostat & Subbase. 067114201 N/A Honeywell Chronotherm III (1 Stage Heat, 1 Stage Cool). N/A= Not Applicable.

1 Heat- 1Cool Thermostats for Single Compressor

Page 18: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 18

Field Installed AccessoriesThermostat Accessories

Description Part Number Night Setback Thermostat Honeywell T822. Mounts vertically. No LED. No Switches. 803005180 For Applications requiring a separate NSB Stat. Universal Thermostat Guard- Honeywell TG512A. 066406601 Clear plastic with ring base, lock and keys. Programmable Thermostat Guard- Honeywell TG511A. 066406702 Clear plastic with ring base, lock and keys. Deluxe Locking Cover for T874/Q674 Thermostats.- Honeywell TG504A. Applies only to T874/Q674 stats. Replaces standard cover. Includes cover, lock & keys. 0733185012

Clear plastic with ring base, lock and keys. Adapter Plate for T874/Q674 Thermostats. 802007673 Allows for horizontal thermostat to be mounted on a vertical junction box. 7- Day Time Clock (not available for 50 cycle power). Includes spring carryover. 802005716 Override Timer- 1 Hour 802005717 Override Timer- 6 Hour 802005718N/A= Not Applicable.2 Do not use with Deluxe ACO Thermostat with override and Subbase 073318801, 073318901, 073320001.

Description Specification Part No. Standard Rubber Supply/Return Hoses. 2 ft. long, 1/2" I.D. 061268801 Hose with one MPT and one MPT swivel fitting. 2 per unit. 3 ft. long, 1/2" I.D. 061268802 Fire- Rated Rubber Supply/Return Hoses . Steel Braided 2 ft. long, 1/2" I.D. 061269001 hose with one MPT and one MPT swivel fitting. 2 per unit. 3 ft. long, 1/2" I.D. 061269002 Condensate Hose Assy. Requires trap by others. Clear plastic, 30" long 060687701 1 per unit. (Includes fitting to be soldered on unit.) Fire rated, 24" long 061300001 Fire rated, 36" long 061300002 Ball Valve. Combination shutoff and balancing valve with 1/2" FPT 802026097 memory stop. 2 per unit. Water Regulating Valve. Dual acting type. Includes Standard Range Units 802026197 flair end for connection to Schrader fitting. Check pressure Model CCH drop across valve above 12 GPM. Maximum working pressure Extended Range Units is 150 psig. 1/2" I.D. Model CCW 802026158

Hoses & Valves

Description Part No. 1 Inch Thick Throwaway Filter. Replacement for standard filter. 060604802 1 Inch Thick Pleated Filter. 35% efficient. 060759813 Full Perimeter Return Air Duct Collar & 2" Filter Rack. Four sheet metal pieces to hold 2" thick filter and allow for easy connection of return air duct onto its 1" collar. 062554501 Replaces standard brackets. 2" thick filter is recommended. 2 Inch Thick Throwaway Filter. Fits into 2" thick filter rack. 060687102 2 Inch Thick Pleated Filter. 35% efficient. 060759802 Roll Filter Section Kit. Completely assembled kit with all necessary mounting holes to 056732201 attach to entering air side of unit. No media is included. Order from below. Roll Filter Duct Collar Kit. All parts included in package for field assembly. Once 056732801 assembled it mounts to roll filter section. Duct attaches directly to duct collar. Roll Filter Media. 50 foot continuous roll of fiberglass media. 056733401 Filter Advancement Crank. 48" length for manually advancing filter media. 056733501

Filters and Filter Components

Page 19: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 19

Description Part No. Shutdown Relay Kit for Electromechanical (EMCP) Control Units. For shutdown of the unit from an external 24 volt AC power source. 061019403 Relay mounts at control box. Code 03 must be "E". Relay is SPDT. Night Setback Relay Kit for Electromechanical Control Units. Relay puts unit into NSB mode from an external 24 volt AC power source. 802005728 Relay mounts at control box. Requires ACO stat with built-in NSB or a separate NSB stat. Code 03 must be "E". Night Setback/Demand Control Relay Kit for EMCP Control Units. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source. Relay mounts at control box, 802007881 operation requires ACO stat with built-in NSB or separate NSB stat. Code 03 must be "E". Auxiliary Relay. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty 803005073 contacts to operate miscellaneous devices when the fan or compressor operate. Contact rating is 3 amp at 24 volts. Boilerless System Kit for Mark IV Control Units.3

Includes electronics and sensor to lock out compressor operation at 50o F to 60o F EWT 062522201 and provide SPNO contacts to a field supplied electric heater control system. Code 03 must be "M". Multiple Unit Control Panel.3 Master & 1 Slave 803005159 Allows master unit to be controlled by any t-stat. Slave units "follow" with paralleled operation. Not recommended with Boilerless System.4 Control of 3 units 056794201 Motorized Valve. Includes prewired valve operator, conduit assembly with leads and 1/2" FPT 060977401 quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum oppressure. Requires control relay below. Control Relay for Motorized Valve 859004354 Auxiliary Relay Kit for DC Mark IV Circuit Board Controller Interface.5 3 Relays 062522203 4 Relays 0625222023 Kit components listed on page following Field Installed Components.4 Do not use when Mark IV night setback, override load shed or emergency shutdown logic is being used.5 Kit components listed below.

Field Installed AccessoriesThermostat Accessories

Description Part No. 3 Relay Kit 4 Relay Kit Relay 802005691 3 3 Relay 802005206 N/A 1 Terminal Board 802007694 1 1 RC Filter Assembly 061048001 3 3 Resistor 060813301 1 1 Capacitor 061048101 1 1 Supressor Assembly 061073401 N/A 1 Supressor 803007214 N/A 1 Diode 803007215 N/A 1N/A= Not Applicable.

Auxiliary Relay Kit for DC Mark IV Components

Page 20: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 20

Description Part No. Qty. Control Box 056388301 1 Cover- Control Box 062521101 1 P.C. Board 803005127 1 Sensor- Temperature 802007871 1 Harness Assembly 060844501 1 Inverter Relay 803005073 1 Resistor 060813301 1

Boilerless System Kit

Field Installed Accessories-Kit Components

Ref. Description Part Qty. No. Number 300 Electrical Box 065812601 1 301 Switch- Silence 065812501 1 302 LED- Red 065810801 1 303 Horn- Alarm 065810901 1 304 LED- Yellow 065810803 1

Remote Alarm Panel (RAP)300

301

302

303304

Ref. Description Part Qty. No. Number 310 Cover- Control Box 106436101 1 311 Circuit Board 056794001 1 312 Stand Off- Circuit Board 802028090 6 313 Box 850007827 1

Multiple Unit Control Panel

310311

313

312

Page 21: McQuay Concealed Ceiling Water Source Heat Pumpsalesportal.daikinapplied.com/bizlit/DocumentStorage/WaterSource... · McQuay Concealed Ceiling Water Source Heat Pump CCH, CCG, CCW

Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS

Critical Daikin Applied OEM PartsAre What Your HVAC Unit Needs!

571048 Rev. N 01/2016 CPL Page 1 of 1

McQuay WSHP, Concealed CeilingCCH, CCG, CCW

015, 019Vintage C

Critical Components Unit Sizes Voltage Part Number

Control Control Board, Mark IV- DC ALL N/A 056792401 Control Board, Mark IV- AC ALL N/A 056792402 Control Board, MicroTech 120 ALL N/A 060959401 Control Board, MicroTech 520 LonWorks ALL N/A 073312502 Control Board, Electromechanical ALL N/A 060679202Fan MotorMotor, 1/8 HP 015 - 019 208-230/60/1 060704501Motor, 1/8 HP 015 - 019 265/60/1 060704502Motor, 1/8 HP 015 - 019 230/50/1 060704503

Fan and Housing Assembly Fan Housing Assy 015 - 019 N/A 060699603Wheel, Blower 015 - 019 N/A 060704801

SensorAir Temperature Sensor for MicroTech 520 LonWorks 015 - 019 N/A 073305601Water Temperature Sensor for MicroTech 520 LonWorks 015 - 019 N/A 073305701Air & Water Temperature Sensor for MicroTech 120 015 - 019 N/A 106110801