McQuay
Concealed Ceiling Water Source Heat Pump
CCH, CCG, CCW
015, 019Vintage C
Last Manufactured: 1999
Replacement Parts List No. 057104800Revision N 01/2016
To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.DaikinApplied.com
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 2
***NOTICE***For CCH, CCW, CCG units, the serial number Revision Level is necessary to
Parts List Revision History..............................................................................................3, 4
Nomenclature Serial Number ...............................................................................................................5 Model Number - Until February, 1999 ............................................................................5 Model Number - February, 1999 and later .....................................................................5 Model Number- Complete ..............................................................................................6
Fan Assembly .....................................................................................................................7
Refrigeration Circuit Diagram .........................................................................................................................8 Components for Serial Number Revision Level 00-04 .............................................9, 10 Components for Serial Number Revision Level 05, 06 ..........................................11, 12 Components for Serial Number Revision Level 07 ................................................13, 14
Control Box .................................................................................................................15, 16
Field Installed Accessories ........................................................................................ 17- 20
Critical Parts List..........................................................................................................CPL1
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 3
A 10-1-96 Updated RPL layout to be consistant w/ OnLine format. B 9-15-97 Added "L" Control note to Cover, Added "L" Control Code to p.4, Added Compressor Overloads for size 015 and Sleeve for Rev. 06 for "L" Control to p.13, Corrected Rev. Valve P/Ns and added Rev. Valve Solenoid for "L" Control to p.14, Added Rev. Valve Solenoid to p.16, Corrected Mark IV/AC Ckt. Brd. P/N and added Temp. Sensor P/Ns to p.19, Corrected Drain Pan P/N on p.22. C 9-23-97 Converted all part numbers to Mitrol format; Removed "L" Control note from Cover; Updated Serial Number Nomenclature, p 4; Updated Field Thermostats and Subbases, pp 5-6; Updated Controls Section, pp 19-20. D 12-8-98 Page 13 - Corrected Compressor information for size 015, 230/50/1. E 9/99 Page 4- Corrected Model Number Nomenclature, Added new Serial Number Nomenclature; Page 5- Added new page for Complete Model Nomenclature, which resulted in the re-numbering of all subsequent pages. Page 7- Added Locking Cover with Override Button; Page 9- Corrected part number for 3-Unit Control Panel; Page 11- Added Condenser and Compressor Mounting details; Page 13- Changed Coil descriptions, Removed Notes and incorporated them into text; Page 14- Added Capacitor Bracket, Fusible Plug PN changed, Added Compressor Gasket, Nut, Spring, and Terminal Cover for size 019, Capacitor for 015, 265V PN changed, Capacitor for 019, 60 Hz. PN changed; Page 15- Coil descriptions changed, Ref. # 4/Capillary PN's changed, Added MicroTech "L" Solenoid, Added Condenser Water & Liquid Tubes and Fittings; Page 17- Changed Coil descriptions, Added "L" Solenoid, Condenser Water & Liquid Tubes & Fittings; Page 19- Ref. # 17 PN changed; Page 20- Removed CB Aux. Module (not used on 015/019), Added new "L" controller -02, Stand Off PNs changed for EMCP, Mark IV, MicroTech "C", Added ELUPC Terminal Block, MicroTech "C" and "L" Compressor Contactor for size 019 PN changed, Removed Terminal Board references for 019 only, Added "no longer used" note to Circuit Breakers, Corrected quantity columns that incorrectly indicated 230/50 usages for MicroTech, Amended note "#", Added Note 5; Page 21- Removed note indicators for Transformers; Page 23- Ref. # 50 Base Pan used after Rev Level 05 PN changed, Added Caged Nut PN, Added Evap Coil Blockoff, Ref. # 56 PN changed, Added Pleated Filter PN, Hanger Bracket Kit PN changed. F 8/00 Page 13-Ref. #2, p/n 060601702 had incorrect description of Copper. Part number 060601801 had incorrect descripton of Cupro-Nickel. G 8/01 Page 9-Control Relay for Motorized Valve pn was corrected from 059004354 to 859004345. H 7/02 Page 13 - Ref. #2, p/n 060601702 had incorrect description of Copper, p/n 060601801 had incorrect descripton of Cupro-Nickel. (This update was to be Rev. F, but for some reason it didn't save). I 6/03 Added second pg. to Rev. History. Added new art. Renumbered footnotes (all subsequent pgs. renumbered). Pages 7 thru 10- Reformatted to new standards. Removed Mark IV T-Stats for 2 compressor units (do not apply). Added details for RAP, MUC panels. Reformatting removed one page. Page 12- Ref. # 1 added manufacturer's number for compressors and overloads. Page 13- Ref. # 8 description corrected so not in all caps. Page 14- Changed headline to define compressor type by unit size. Added manufacturer's number for compressors. Page 15- Ref. # 11 p/n changed to 802017216. Page 16- Ref. # 1 added manufacturer's number for compressors, and added compressor parts. Page 21- 50 Hz. Terminal Block qty. changed to 3. Page 23- Corrected spelling for Evap blockoff. Ref. # 50 p/n for Rev. 05 Base Pan changed to 057576702. J 11/08 Page 6 - Code #2 change 7,000 BTU to 15,000 BTU and 9,000 BTU to 19,000 BTU. K 4/09 Page 20- Added DC to Mark IV Board p/n 056792401. Added Mark IV Board AC p/n 056792402 and added notes to footnote #7 and #11. L 01/10 Page 20- Change footnote #11 for Mark IV control units p/n 056792404 to 056792402. M 2/15 Rebrand to Daikin. Deleted compressor vendor numbers and updated capacitors. Page 7 Deleted sheetmetal and add footnote for cabinet/chassis components. Page 21- Add drain pan, filters and condenstate overflow components. Pages 22-23 Deleted cabinet sheetmetal.
Control SystemE = Electromechanical Printed Circuit BoardM = Mark IV /AC Control SystemC = MicroTech 120 Unit Controller L = MicroTech 520 LonWorks Unit Controller
Discharge Air ArrangementS = Straight DischargeE = End Discharge
VoltageJ = 230/50/1G = 208-230/60/1N = 265/60/1
Model Type
7 6 A 00000 00
Nomenclature
Plant Identification Number7 = Auburn
Serial Number
Month Manufactured A = January B = February C = March D = April E = May F = June
8. Water Regulating Valve*W= Water Regulating ValveY= None
9. Starting ControlR= Random Start Relay(only used with Electromechanical control)
10. Overflow ProtectionF= Float Switch(only used with Electromechanical control)
11. ControlsSDR= Shutdown RelayElectromechanical Control OnlyNSR= Night Setback RelayElectromechanical Control OnlyNSD= Night Setback and Demand Control RelayElectromechanical Control OnlySDN= Shutdown and Night Setback RelayElectromechanical Control OnlyMTR= Timed Output RelayMicroTech or MircoTech 520 LonWorks onlyMTV= Motorized ValveMicroTech or MircoTech 520 LonWorks onlyMBS= Boilerless System RelayMicroTech or MircoTech 520 LonWorks onlyMFD= Fresh Air DamperMicroTech or MircoTech 520 LonWorks only
12. Auxiliary RelayY= NoneA= Auxiliary Relay*
14. Filter*A= ThrowawayB= Pleated
15. Paint*Y= None
16. Finned Tube Coil*1= Copper Tube/Aluminum Coil
17. Fan Housing/Wheel and Motor Assembly*D= Direct Drive 2 speed
18. Logo and Nameplate*M= McQuay (may also have been labeled SnyderGeneral)
19. Construction Code*Y= NoneC= Chicago
20. Agency Listing*W= ETL, CSA, MEA, ARIY= None
21. WarrantyA= StandardQ= Extended 4-year Compressor Warranty (5 year total)S= Extended 4-year Refrigerant Circuit Warranty (5 year total)
*Codes not listed in price book. These are standard items that will only change in the case of a special, which will be denoted with an "X" in the appropriate code.
CCH 015C L N S E C W Y Y MTV Y A Y 1 D M Y W Q Code: 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 7
Fan AssemblyDiagram
15
19 20
18
16
Cabinet/Chassis components
015 019
Ref. Description Part No. Number 15 Motor, 1/8 HP 060704501 1 1 1 1 Motor, 1/8 HP 060704502 1 1 Motor, 1/8 HP 060704503 1 1
N/S Cabinet/Chassis components 1 1 1 1 1 1 1 1 1N/S = Not shown on diagram.1 Contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components.
208/
60/1
230/
60/1
265/
60/1
230/
50/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 8
Refrigeration CircuitDiagram
Condenser
Reversing Valve &
Solenoid
High PressureSwitch
Compressor
Low Temp.T-Stat
Accumulator
Evaporator Coil
Strainer
Condenser
Condenser Detail Compressor Mounting Detail
Compressor
Mounting Stud
Mounting Plate
1
8
2
6 7
11
1012
5
4
3
21
20
2122
58
57
61
To Water Regulating Valve
(optional)
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 9
Air and Water Temperature Sensor 9 until 12/99 4EZS9158 2 2 2 2 2 2 Air and Water Temperature Sensor 9 12/99 & later 106110801 2 2 2 2 2 2 Air Temperature Sensor 10 073305601 1 1 1 1 1 1 Water Temperature Sensor 10 073305701 1 1 1 1 1 1 Sensor, Clamp 9 802017214 2 2 2 2 2 2
Stand Off 11, 13, 15 802028115 5 5 5 5 5 5 5 5 Stand Off 12, 13, 15 802028115 4 4 4 4 4 4 4 4 Stand Off 9, 10, 15 802028115 1 1 1 1 1 1 1 1 Nut, Nylon 11, 15 802012415 5 5 5 5 5 5 5 5 Nut, Nylon 12, 15 802012415 4 4 4 4 4 4 4 4 Nut, Nylon 9, 10, 15 802012415 1 1 1 1 1 1 1 1 Contactor, Compressor 11, 12 073322401 1 1 1 1 Contactor, Compressor 11, 12 802005655 1 Contactor, Compressor 11, 12 073322301 1 1 Contactor, Compressor 11, 12 073322201 1 Contactor, Compressor 9, 10 047356506 1 1 1 1 Contactor, Compressor 9, 10, 14 073300101 1 1 1 1 Relay, Fan 047356506 1 1 1 1 1 1 Relay, Fan 803005132 1 1 Board, Terminal 9, 10 802007090 1 1 1 1 1 1 Circuit Breaker (no longer used as of 1/99) 803007113 1 1 1 1 1 1 1 17 When replacing reversing valve and/or coil refer to Service Bulletin WS-SB-20070423.8 Units with Serial Revision level 07 or below use p/n 060959401. Units with serial revision level 08 and above use p/n 073312501 (02).9 MicroTech 120 Control units only. (C03 = C).10 MicroTech 520 LonWorks Control units only. (C03 = L). 11 Units with Serial Revision level 03 or below used p/n 060638806 (N/A use 056792401). Units with Serial Revision level 04 and above use p/n 056792401. Mark IV Control units (C03 = M).12 Electromechanical Control units only. (C03 = E).13 Used after 8/96.14 On units built before 4/98 the contactor was p/n 803005223 and the 019 also used a Terminal Board. p/n 802007090. The 073300101 Relay replaces both parts.15 Prior to 6/95, the PC Board used Stand Off p/n 802028130 and the Nylon Nut was used to attach it. After this date the new stand off (802028115) replaced both parts.
Control BoxComponents
208/
60/1
230/
60/1
265/
60/1
230/
50/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 16
Miscellaneous Components Drain Pan 060637902 1 1 1 1 1 1 1 1 Hanger Bracket Kit 060676301 1 1 1 1 1 1 1 1 9 MicroTech 120 Control units only. (C03 = C).10 MicroTech 520 LonWorks Control units only. (C03 = L).12 Electromechanical Control units only. (C03 = E).16 Only on units with Random Start Relay Option.17 Only on units with Shutdown Relay Option.18 Only on units with Night Setback Option.19 Only on units with Demand Control Option.20 Only on units with Auxiliary Relay Option & without MicroTech Control. 21 Used only on MicroTech 120 and Mark IV controls.
Control BoxComponents
208/
60/1
230/
60/1
265/
60/1
230/
50/1
208/
60/1
230/
60/1
265/
60/1
230/
50/1
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 17
Field Installed AccessoriesThermostats for Electromechanical Control Units
Description Thermostat Subbase Standard Manual Changeover Thermostat & Subbase. Honeywell T834C with no LED. Mounts vertically. 073319501 N/A System "Heat-Off-Cool" switch and fan "On-Auto" switch. (includes subbase) Standard Automatic Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319701 System "Off-Auto" switch and fan "On-Auto" switch. Deluxe Auto. Changeover T-stat & Subbase w/ Night Setback. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Req. factory installed NSB relay (Code 11=NSR,NSD or SDN) or 073318801 073320001 Field installed NSB or NSB/demand control relay. Night setback bulb set 8o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Programmable Electronic Thermostat & Subbase. 0671143011 N/A Honeywell Chronotherm III (2 Stage Heat, 2 Stage Cool). N/A= Not Applicable.1 Use this thermostat to eliminate "whooshing" sound during heating cycle.
Thermostats for Mark IV/AC Control Units
Description Thermostat Subbase Standard Manual Changeover Thermostat & Subbase. Honeywell T834C with no LED. Mounts vertically. 073319501 N/A System "Heat-Off-Cool" switch and fan "On-Auto" switch. (includes subbase) Standard Automatic Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319701 System "Off-Auto" switch and fan "On-Auto" switch. Std. Manual & Auto. Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319801 System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Deluxe Auto. Changeover T-stat & Subbase w/Night Setback. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Req. factory installed NSB relay (Code 11=NSR,NSD or SDN) or 073318801 073320001 Field installed NSB or NSB/demand control relay. Night setback bulb set 8o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Standard Auto. Changeover Thermostat & Subbase. For Operating Two Units. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319101 073319601 System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Programmable Electronic Thermostat & Subbase. 067114201 N/A Honeywell Chronotherm III (1 Stage Heat, 1 Stage Cool). N/A= Not Applicable.
1 Heat- 1Cool Thermostats for Single Compressor
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 18
Field Installed AccessoriesThermostat Accessories
Description Part Number Night Setback Thermostat Honeywell T822. Mounts vertically. No LED. No Switches. 803005180 For Applications requiring a separate NSB Stat. Universal Thermostat Guard- Honeywell TG512A. 066406601 Clear plastic with ring base, lock and keys. Programmable Thermostat Guard- Honeywell TG511A. 066406702 Clear plastic with ring base, lock and keys. Deluxe Locking Cover for T874/Q674 Thermostats.- Honeywell TG504A. Applies only to T874/Q674 stats. Replaces standard cover. Includes cover, lock & keys. 0733185012
Clear plastic with ring base, lock and keys. Adapter Plate for T874/Q674 Thermostats. 802007673 Allows for horizontal thermostat to be mounted on a vertical junction box. 7- Day Time Clock (not available for 50 cycle power). Includes spring carryover. 802005716 Override Timer- 1 Hour 802005717 Override Timer- 6 Hour 802005718N/A= Not Applicable.2 Do not use with Deluxe ACO Thermostat with override and Subbase 073318801, 073318901, 073320001.
Description Specification Part No. Standard Rubber Supply/Return Hoses. 2 ft. long, 1/2" I.D. 061268801 Hose with one MPT and one MPT swivel fitting. 2 per unit. 3 ft. long, 1/2" I.D. 061268802 Fire- Rated Rubber Supply/Return Hoses . Steel Braided 2 ft. long, 1/2" I.D. 061269001 hose with one MPT and one MPT swivel fitting. 2 per unit. 3 ft. long, 1/2" I.D. 061269002 Condensate Hose Assy. Requires trap by others. Clear plastic, 30" long 060687701 1 per unit. (Includes fitting to be soldered on unit.) Fire rated, 24" long 061300001 Fire rated, 36" long 061300002 Ball Valve. Combination shutoff and balancing valve with 1/2" FPT 802026097 memory stop. 2 per unit. Water Regulating Valve. Dual acting type. Includes Standard Range Units 802026197 flair end for connection to Schrader fitting. Check pressure Model CCH drop across valve above 12 GPM. Maximum working pressure Extended Range Units is 150 psig. 1/2" I.D. Model CCW 802026158
Hoses & Valves
Description Part No. 1 Inch Thick Throwaway Filter. Replacement for standard filter. 060604802 1 Inch Thick Pleated Filter. 35% efficient. 060759813 Full Perimeter Return Air Duct Collar & 2" Filter Rack. Four sheet metal pieces to hold 2" thick filter and allow for easy connection of return air duct onto its 1" collar. 062554501 Replaces standard brackets. 2" thick filter is recommended. 2 Inch Thick Throwaway Filter. Fits into 2" thick filter rack. 060687102 2 Inch Thick Pleated Filter. 35% efficient. 060759802 Roll Filter Section Kit. Completely assembled kit with all necessary mounting holes to 056732201 attach to entering air side of unit. No media is included. Order from below. Roll Filter Duct Collar Kit. All parts included in package for field assembly. Once 056732801 assembled it mounts to roll filter section. Duct attaches directly to duct collar. Roll Filter Media. 50 foot continuous roll of fiberglass media. 056733401 Filter Advancement Crank. 48" length for manually advancing filter media. 056733501
Filters and Filter Components
WSHP; CCH, CCG, CCW Sizes 015, 019 Vintage C Rev. M 2/15 RPL 0571048 / Page 19
Description Part No. Shutdown Relay Kit for Electromechanical (EMCP) Control Units. For shutdown of the unit from an external 24 volt AC power source. 061019403 Relay mounts at control box. Code 03 must be "E". Relay is SPDT. Night Setback Relay Kit for Electromechanical Control Units. Relay puts unit into NSB mode from an external 24 volt AC power source. 802005728 Relay mounts at control box. Requires ACO stat with built-in NSB or a separate NSB stat. Code 03 must be "E". Night Setback/Demand Control Relay Kit for EMCP Control Units. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source. Relay mounts at control box, 802007881 operation requires ACO stat with built-in NSB or separate NSB stat. Code 03 must be "E". Auxiliary Relay. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty 803005073 contacts to operate miscellaneous devices when the fan or compressor operate. Contact rating is 3 amp at 24 volts. Boilerless System Kit for Mark IV Control Units.3
Includes electronics and sensor to lock out compressor operation at 50o F to 60o F EWT 062522201 and provide SPNO contacts to a field supplied electric heater control system. Code 03 must be "M". Multiple Unit Control Panel.3 Master & 1 Slave 803005159 Allows master unit to be controlled by any t-stat. Slave units "follow" with paralleled operation. Not recommended with Boilerless System.4 Control of 3 units 056794201 Motorized Valve. Includes prewired valve operator, conduit assembly with leads and 1/2" FPT 060977401 quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum oppressure. Requires control relay below. Control Relay for Motorized Valve 859004354 Auxiliary Relay Kit for DC Mark IV Circuit Board Controller Interface.5 3 Relays 062522203 4 Relays 0625222023 Kit components listed on page following Field Installed Components.4 Do not use when Mark IV night setback, override load shed or emergency shutdown logic is being used.5 Kit components listed below.
Ref. Description Part Qty. No. Number 310 Cover- Control Box 106436101 1 311 Circuit Board 056794001 1 312 Stand Off- Circuit Board 802028090 6 313 Box 850007827 1
Multiple Unit Control Panel
310311
313
312
Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs.To Locate A Distributor, Go To www.DaikinApplied.com or Call 1-800-37PARTS
Critical Daikin Applied OEM PartsAre What Your HVAC Unit Needs!
571048 Rev. N 01/2016 CPL Page 1 of 1
McQuay WSHP, Concealed CeilingCCH, CCG, CCW
015, 019Vintage C
Critical Components Unit Sizes Voltage Part Number
Control Control Board, Mark IV- DC ALL N/A 056792401 Control Board, Mark IV- AC ALL N/A 056792402 Control Board, MicroTech 120 ALL N/A 060959401 Control Board, MicroTech 520 LonWorks ALL N/A 073312502 Control Board, Electromechanical ALL N/A 060679202Fan MotorMotor, 1/8 HP 015 - 019 208-230/60/1 060704501Motor, 1/8 HP 015 - 019 265/60/1 060704502Motor, 1/8 HP 015 - 019 230/50/1 060704503
Fan and Housing Assembly Fan Housing Assy 015 - 019 N/A 060699603Wheel, Blower 015 - 019 N/A 060704801
SensorAir Temperature Sensor for MicroTech 520 LonWorks 015 - 019 N/A 073305601Water Temperature Sensor for MicroTech 520 LonWorks 015 - 019 N/A 073305701Air & Water Temperature Sensor for MicroTech 120 015 - 019 N/A 106110801