CBI)1;OIJ;TBO - Peppers Cable Glands€¦ · the standards set forth in GOST 12.2.007.0, DSTU 7113, DSTU 7114, GOST 22782.7, and their explosion-protection marking: Ex d IIC XlEx
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ABCLI BO Aep>KaBH 101 ~
Blo1npo6YBallbHIo1~ CepTlo1cpiKalli~HIo1~
lIeHTp Blo16yxo3axlo1U1eHoro Ta PYAHIo1KOBoro 0611aAHaHH~
2. fany3h 3aCTOCYBaHH5I Ka6enhHMx BBO,lliB Ta Ka6enhHoI apMaTypM 06YMOBneHO IX MapKYBaHH5IM BM6yxo3axMcTY 3ri,llHO 3 ,aCTY 7113:2009 Ex d IIC XlEx e 11 X- ,lln5r Ka6enhHMx BBO,lliB TMrriB CR-*** CR-D** E****F* D****F* , , , , A8*F, A8C**F, D8X*F, E8X*F, CR-C, CR-X, CR-U, CR-S, UL-C, UL-X, UL-U Ex e 11 X - ,lln5I Ka6enhHMX BBO,lliB TMrriB CR-O***, C****E* Ex d IIC XlEx e 11 X a60 Ex e 11 X - ,lln5I Ka6enhHMx BBO,lliB TMrriB A*L**, A*LDS**, A*RDC**, A*RDF** , A*RDM**, A*LC***, A*RC*** Ex d IIC VI Ex d I V/Ex ell V/Ex e I V a60 Ex e 11 V/Ex e I V - ,lln5I a,llarrTepiB TMrriB ARMR,ARFR Ex d IIC V/Ex e 11 U a60 Ex dIU /Ex e I V - ,lln5I a,llarrTepiB TMrry AR, ARMM, ARFF Ta 3arnYlllOK TMrriB SPA, SPB, SPMH, SPHH Ex e 11 V a60 Ex e I V - ,lln5I ,llpeHa)l(HMX rrpMcTpoIB TMrry ACDP
3. Ha Koprrycax Ka6enhHMx BBO,lliB Ta Ka6enhHoI apMaTypM TaKO)l( MaIOTh 6YTM HaHeceHi CMMBon (a60 CKOpOQeHe HaHMeHYBaHH5I) ,aBC.u BO 3 HOMepOM Uhoro CBi,lloUTBa Ta
STCCExE State Testing Certification Center for Explosion Protected and Mining Equipment
DONETSK
CERTIFICATE of Explosion-Protected Electrical Equipment
(Electrical Device)
No. 2937 This certificate, issued to Peppers Cable Glands Limited, Stanhope Roads, Camberley, Surrey GUIS 3BT (Great Britain), hereby attests that the products manufactured by that company, namely: cable glands series CR-***, CR-D**, CR-O***, E****F*, D****F, C****E*, A *L**, A*LDS**, A*RDC**, A*RDF**, A*RDM**, A*LC***, A*RC***, E8X*F, D8X*F, A8*F, A8C**F, CR-C, CR-X, CR-U, CR-S, UL-C, UL-X, UL-U, adapters types AR, ARFF, ARMM, ARMRlARFR, plugs types SPA, SPB, SPMH, SPHH, breather drain type ACDP comply the requirements for explosion protection set forth in the normative legal acts on labor safety with regard to the common electrical safety norms. On the basis of the technical documentation of the expert evaluations conducted at TCCExEE for the purpose of examining and testing the product, and in accordance with the standards set forth in GOST 12.2.007.0, DSTU 7113, DSTU 7114, GOST 22782.7, and their explosion-protection marking:
Ex d IIC XlEx ell X - for cable glands CR-***, CR-D**, E****F* , D****F*, A8*F, A8C**F, D8X*F, E8X*F, CR****, UL Ex e 11 X - for cable glands CR-O***, C****E* Ex d IIC XlEx e 11 X a60 Ex e 11 X - for cable glands A ****, A *L **, A *RC***, A *LC*** Ex d IIC UlEx e 11 U - for adaptors ARMR, ARFR Ex d IIC UlEx e 11 UlEx e I U a60 Ex d I UlEx e I U Ex e 11 U - for breather drain ACDP Ex d IIC XlEx e 11 X - for adaptors AR, ARMM, ARFF and stopping plugs SPA, SPB, SPMH, SPHH
These products must be used in accordance with the section entitled "Conditions of Use", which is an integral part of this certificate.
Certificate valid until July 01, 2018
Certificate validity extended until
Director of STCCExE (signed) K. V. Mezhenkov
[Round seal: UKRAINE, DONETSK, ISOLATED DIVISION DVSC YE, IDENT. CODE 36559482, STATE TESTING CERTIFICATION CENTER OF EXPLOSION PROTECTED AND MINING EQUIPMENT]
Place Seal Here
This document is numbered and affIXed with a seal in 2 pages
Conditions of Use
Page 2 STCCExE Certificate No. 2937
1. Explosion-protected cable glands types CR-***, CR-D**, CR-O***, E* ***F*, D****F, C****E*, A*L* *, A*LDS** , A*RDC** , A*RDF**, A*RDM** , A*LC*** , A*RC***, E8X*F, D8X*F, A8*F, A8C* *F, CR-C, CR-X, CR-U, CR-S, UL-C, UL-X, UL-U, adapters types AR, ARFF, ARMM, ARMRlARFR, plugs types SPA, SPB, SPMH, SPHH, breather drain types ACDP (hereafter referred to as cable glands and cable accessories) may be used in explosion hazard zones in indoor and outdoor facilities, in accordance with the requirements set forth in Chapter 4 of State Normative Act on Labor Protection 0.00-1.32-01 , "Rules for Electrical Facility Construction. Electrical Equipment for Special Devices".
2. The scope of application of cable glands and cable accessories is determined by their Exmarking according to the DSTU 7113:2009
Ex d IIC XlEx e 11 X - for cable glands CR-*** , CR-D**, E****F*, D****F*, A8*F, A8C**F, D8X*F, E8X*F, CR**** , UL Ex e 11 X - for cable glands CR-O*** , C*** *E* Ex d IIC XlEx ell X a60 Ex e 11 X - for cable glands A ****, A *L **, A *RC***, A *LC*** Ex d lIe UlEx e 11 U - for adaptors ARMR, ARFR Ex d lIe UlEx e 11 UlEx e I U a60 Ex d I UlEx e I U Ex ell U - for breather drain ACDP Ex d lIe XlEx e 11 X - for adaptors AR, ARMM, ARFF and stopping plugs SPA, SPB, SPMH, SPHH
3. The cable glands and cable accessories should bear the logo (or the short title) of STCEExE with the number of this certificate and national conformity mark with number ofSTCEExE as authorized conformity assessment body:
UA.TR047
4. The cable glands and cable accessories should bear the temperature range of the environment for use of the cable glands and cable accessories.
5. Peppers Cable Glands Limited (Great Britain) shall bear liability for the compliance of the design of the technical devices produced to that of the certified samples
6. Any amendments or additions to the design of the technical devices and affecting their explosion protection must be approved by STCCExE.
7. Special Conditions of use: 7.1 Cable glands types CR-*** , CR-D**, CR-O** *, A8*F, A8C**F, D8X*F Ta E8X*F shall not be used in enclosures where the temperature, at the point of entry/mounting, is outside of the range -60QC to + 180 QC.
7.2 The CR-*** , CR-D**, CR-O* **, A8*F, A8C**F, D8X*F and E8X*F range of cable glands shall only be used for fixed installations, in addition, the cables must be effectively clamped to prevent pulling or twisting.
Page 2 STCCExE Certificate No. 2937
7.3 The CR-*** , CR-D**, CR-O* **, C* ** *E*, E****F* , D*** *F, A*L* *, A*LDS* *, A*RDC** , A*RDF** , A*RDM**, A*LC*** , A*RC*** cable glands shall not be used in enclosures where the temperature, at the point of entry/mounting is outside of the range
- 35°C to +90°C for neoprene seal variants - 60°C to + 180°C for the silicone seal variants
7.4 The CR-C, CR-X, CR-U, CR-S, UL-C, UL-X, UL-U range of cable glands shall not be used in enclosures where the temperature, at the point of entry/mounting, is outside of the range - 60 °C.no + 135 °C
7.5 When no seal is fitted and the stopping plug or the breather drain is installed in an increased safety (Ex e) enclosure, the user shall ensure that a minimum degree of protection IP54 is maintained.
7.6 The SPA, SPB, SPMH, SPHH plugs, breather drains ACDP, angle adapters types ARMR, ARFR shall not be used in enclosures where the temperature, at the point of entry/mounting, is outside of the temperature range determined by the material of the sealing ring used.
7.7 The Stopping Plugs shall not be used in conjunction with an adaptor or reducer when installed in a flameproof enclosure.
7.8 Adaptors and Reducers shall not to be used for the direct inter-connection of enclosures.
7.9 Only one adaptor or reducer is to be used with any single cable entry on the associated equipment.
7.10 The breather drains are only suitable for bottom entry applications within associated enclosures.
Chief Executive of STCCExE (signed) K. V. Mezhenkov
[seal: TCCExEE State Testing Certification Center for Explosion Protected and Mining Electrical Equipment