Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc. Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc. THE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: Joseph A. Silvaggio, Jr. & Carolyn B. Smith Siemens Demag Delaval Turbomachinery, Inc. .
15

Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed.....

Feb 14, 2018

Download

Documents

ngomien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

THE “REPAIR OR REPLACE” DECISION OF BOILER FEED

PUMP IMPELLERSBy:Joseph A. Silvaggio, Jr. & Carolyn B. Smith

Siemens Demag Delaval Turbomachinery, Inc..

Page 2: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Problem Statement

• Current boiler feed pumps are reliably running 5 to as many as 20 years before being overhauled.

• When an overhaul is required, the inner assembly of a high pressure pump can be removed and replaced by a refurbished inner assembly.

• The removed inner assembly should be disassembled, inspected and refurbished.

• The inner assembly contains impellers that, depending on the inspection data, will either need repair or replacement (if not reusable “as is”).

• The decision of whether to repair or replace an impeller is a difficult decision and is the subject of this case study.

Page 3: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Pump Type

• The type of pump for this case study is a high pressure double case type pump. It is usually a high speed, turbine driven boiler feed pump in power plants of 500 to 800 megawatts.

Page 4: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Case Study Outline

• Pump Description• Background• Impeller description• Examples of impeller inspection data• Making the decision to “repair or replace”• Conclusions

Page 5: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Background - Pump Assembly(high speed, multistage, turbine driven)

Page 6: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Pump Stage Component Terminology

Page 7: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Recommended Impeller Inspection

• Visual• Dimensional• Magnetic Particle or Dye Penetrant

Page 8: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Impeller Materials

• 17-4PH• CA6NM• Both materials can be welded, but require

pre-heat and post-heat treatment during the welding process.

• Because the post-heat treatment is at a high temperature, all critical dimensions will require welding.

Page 9: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Impeller With Shroud and Hub Seal Wear

WEAR

WEAR

Page 10: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Impeller With Shroud and Hub Seal Wear

WEAR WEAR

Page 11: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Impeller With Vane Cavitation Damage

Page 12: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Impeller With Cracks

Page 13: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Failed Impeller With Catastrophic Damage

Page 14: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

The Repair or Replace DecisionCost Equation Components

Cost of Casting

Cost of NDE

Cost of Machining

Cost of Welding

Cost of Pre-

Machining

Cost of Skimming Seal Areas

Cost of Rough

Machining

Cost of Final

Machining

Cost of NDE

Probability of Porosity in Casting

Probability of Casting

Dimensional Problems if the Impeller Geometry is Recreated

Probability of

Machining Error

Vintage of Impeller

Probability Past 3rd

Party Repairs

Interfering with

Current Repairs

Probability of Porosity in Casting

Probability of

Inclusions or Lack of Fusion in

Welds

Experience of Involved Personnel

Experience of Involved Personnel

REPLACE WITH NEW IMPELLER

REPAIR EXISTING IMPELLER

Probability of

Machining Error

Cost of Balancing

Cost of Balancing

Profit

Overhead

<>or=

Page 15: Case Study P3: The 'Repair or Replace' Decision of Boiler ... · PDF fileTHE “REPAIR OR REPLACE” DECISION OF BOILER FEED PUMP IMPELLERS By: ... turbine driven boiler feed pump

Copyright © 2014 by Siemens Demag Delaval Turbomachinery, Inc.

Conclusions• There are many factors that influence whether and impeller is

repaired or replaced:

– Extent of damage

– Impeller history

– Impeller vintage

– Material costs

– Machining costs

– In-process inspection costs

– Experience of personnel

• The probability and cost of non-conformance must be evaluated before a proper decision can be made.