Our technology. Your success. Pumps n Valves n Service CHTC – Boiler feed pump Applications: Handling of boiler feed water and condensate in power stations and industrial facilities Generation of pressurised water for descaling equipment More information: www.ksb.com/products
2

CHTC – Boiler feed pump - KSB · PDF fileOur technology. Your success. Pumps n Valves n Service CHTC – Boiler feed pump Applications n Handling of boiler feed water and condensate

Mar 16, 2018

Download

Documents

haquynh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CHTC – Boiler feed pump - KSB · PDF fileOur technology. Your success. Pumps n Valves n Service CHTC – Boiler feed pump Applications n Handling of boiler feed water and condensate

Our technology. Your success.Pumps n Valves n Service

CHTC – Boiler feed pump

Applications: ■■ Handling of boiler feed water and condensate

in power stations and industrial facilities ■■ Generation of pressurised water for descaling

equipment

More information: www.ksb.com/products

Page 2: CHTC – Boiler feed pump - KSB · PDF fileOur technology. Your success. Pumps n Valves n Service CHTC – Boiler feed pump Applications n Handling of boiler feed water and condensate

KSB AktiengesellschaftJohann-Klein-Straße 967227 Frankenthal (Germany) www.ksb.com

1860

.021

/02-

EN /

02.

14 /

© K

SB A

kti

eng

esel

lsch

aft

2014

· Su

bje

ct t

o t

ech

nic

al m

od

ific

atio

n w

ith

ou

t p

rio

r n

oti

ce

CHTC – Boiler feed pump

12 3

4

5

2

6

7

7

8

High operating reliability

1 In the case of axial thrust balancing by double drum,

the residual axial thrust is absorbed by a tilting-pad

thrust bearing

2 Optimisation of casing design in terms of line of action

of force

3 Adaptation of pump casing to rotor deflection line

Long service life

4 Transmission of axial forces to the bearing housing by

means of a cardanic ring avoids wear on the thrust bearing

5 Low NPSH value thanks to fitting of suction stage impeller

as a standard

Ease of service

6 Replacement of pump cartridge without having to remove

the pump from the piping

7 Maintenance work on wear parts with no opening of the

pump

Reduced operating costs

8 Efficiency improvement through cellular surface wear rings

Materials

Barrel Carbon steel

Stage casing Chromium steel

Impeller / diffuser Chromium steel

Shaft Quenched andtempered steel

Technical data*

Capacity up to 1,280 m3/h

Head up to 4,200 m

Operating pressure up to 420 bar

Temperature up to 200 °C

Speed up to 6,750 min-1

Frequency 50/60 Hz

*Higher ratings on request